1.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
2.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
3.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
4.Efficacy of Oral Sulfate Tablet and 2 L-Polyethylene Glycol With Ascorbic Acid for Bowel Preparation: A Prospective Randomized KASID Multicenter Trial
Yunho JUNG ; Hyun Gun KIM ; Dong-Hoon YANG ; Hyoun Woo KANG ; Jae Jun PARK ; Dong Hoon BAEK ; Jaeyoung CHUN ; Tae-Geun GWEON ; Hyeon Jeong GOONG ; Min Seob KWAK ; Hyun Jung LEE ; Soo-Kyung PARK ; Jong Hoon LEE
Journal of Korean Medical Science 2024;39(48):e301-
Background:
Oral sulfate tablets (OSTs) are bowel preparation agents that combine oral sulfate solution and simethicone. This study compared the efficacy, tolerability, and safety of OST compared to 2 L-polyethylene glycol plus ascorbic acid (2 L-PEG/ASC).
Methods:
This prospective, randomized, controlled, single-blinded, multicenter, noninferiority trial enrolled 211 healthy adults who underwent colonoscopy between May 2020 and September 2022 at 13 university hospitals. The bowel cleansing rate was assessed using the Boston Bowel Preparation Scale (BBPS) and Harefield Cleansing Scale (HCS), and the preparation agents were administered in split regimens.
Results:
The total BBPS score (8.2 ± 1.5 vs. 7.8 ± 1.4, p = 0.040) and the high-quality bowel cleansing rates in the right colon (73.2% vs. 50.5), transverse colon (80.6% vs. 68.0%), and left colon (81.5% vs. 67.0%) on the BBPS were significantly higher in the OST group than in the 2 L-PEG/ASC group. However, the rates of successful cleansing according to BBPS (90.7% vs. 91.2%) and HCS (96.3% vs. 94.2%) did not significantly differ between the two groups.The taste, ease, and amount of consumption of the preparation agent; and willingness to repeat colonoscopy with the same agent (89.8% vs. 78.6%, P = 0.026) were significantly better in the OST group compared to the 2 L-PEG/ASC group. Adverse events and clinically significant laboratory changes were not significantly different between the two groups.
Conclusion
The OST was not inferior to 2 L-PEG/ASC in terms of bowel cleansing efficacy and showed better tolerability when used for bowel preparation for colonoscopy.
5.Efficacy of Oral Sulfate Tablet and 2 L-Polyethylene Glycol With Ascorbic Acid for Bowel Preparation: A Prospective Randomized KASID Multicenter Trial
Yunho JUNG ; Hyun Gun KIM ; Dong-Hoon YANG ; Hyoun Woo KANG ; Jae Jun PARK ; Dong Hoon BAEK ; Jaeyoung CHUN ; Tae-Geun GWEON ; Hyeon Jeong GOONG ; Min Seob KWAK ; Hyun Jung LEE ; Soo-Kyung PARK ; Jong Hoon LEE
Journal of Korean Medical Science 2024;39(48):e301-
Background:
Oral sulfate tablets (OSTs) are bowel preparation agents that combine oral sulfate solution and simethicone. This study compared the efficacy, tolerability, and safety of OST compared to 2 L-polyethylene glycol plus ascorbic acid (2 L-PEG/ASC).
Methods:
This prospective, randomized, controlled, single-blinded, multicenter, noninferiority trial enrolled 211 healthy adults who underwent colonoscopy between May 2020 and September 2022 at 13 university hospitals. The bowel cleansing rate was assessed using the Boston Bowel Preparation Scale (BBPS) and Harefield Cleansing Scale (HCS), and the preparation agents were administered in split regimens.
Results:
The total BBPS score (8.2 ± 1.5 vs. 7.8 ± 1.4, p = 0.040) and the high-quality bowel cleansing rates in the right colon (73.2% vs. 50.5), transverse colon (80.6% vs. 68.0%), and left colon (81.5% vs. 67.0%) on the BBPS were significantly higher in the OST group than in the 2 L-PEG/ASC group. However, the rates of successful cleansing according to BBPS (90.7% vs. 91.2%) and HCS (96.3% vs. 94.2%) did not significantly differ between the two groups.The taste, ease, and amount of consumption of the preparation agent; and willingness to repeat colonoscopy with the same agent (89.8% vs. 78.6%, P = 0.026) were significantly better in the OST group compared to the 2 L-PEG/ASC group. Adverse events and clinically significant laboratory changes were not significantly different between the two groups.
Conclusion
The OST was not inferior to 2 L-PEG/ASC in terms of bowel cleansing efficacy and showed better tolerability when used for bowel preparation for colonoscopy.
6.Efficacy of Oral Sulfate Tablet and 2 L-Polyethylene Glycol With Ascorbic Acid for Bowel Preparation: A Prospective Randomized KASID Multicenter Trial
Yunho JUNG ; Hyun Gun KIM ; Dong-Hoon YANG ; Hyoun Woo KANG ; Jae Jun PARK ; Dong Hoon BAEK ; Jaeyoung CHUN ; Tae-Geun GWEON ; Hyeon Jeong GOONG ; Min Seob KWAK ; Hyun Jung LEE ; Soo-Kyung PARK ; Jong Hoon LEE
Journal of Korean Medical Science 2024;39(48):e301-
Background:
Oral sulfate tablets (OSTs) are bowel preparation agents that combine oral sulfate solution and simethicone. This study compared the efficacy, tolerability, and safety of OST compared to 2 L-polyethylene glycol plus ascorbic acid (2 L-PEG/ASC).
Methods:
This prospective, randomized, controlled, single-blinded, multicenter, noninferiority trial enrolled 211 healthy adults who underwent colonoscopy between May 2020 and September 2022 at 13 university hospitals. The bowel cleansing rate was assessed using the Boston Bowel Preparation Scale (BBPS) and Harefield Cleansing Scale (HCS), and the preparation agents were administered in split regimens.
Results:
The total BBPS score (8.2 ± 1.5 vs. 7.8 ± 1.4, p = 0.040) and the high-quality bowel cleansing rates in the right colon (73.2% vs. 50.5), transverse colon (80.6% vs. 68.0%), and left colon (81.5% vs. 67.0%) on the BBPS were significantly higher in the OST group than in the 2 L-PEG/ASC group. However, the rates of successful cleansing according to BBPS (90.7% vs. 91.2%) and HCS (96.3% vs. 94.2%) did not significantly differ between the two groups.The taste, ease, and amount of consumption of the preparation agent; and willingness to repeat colonoscopy with the same agent (89.8% vs. 78.6%, P = 0.026) were significantly better in the OST group compared to the 2 L-PEG/ASC group. Adverse events and clinically significant laboratory changes were not significantly different between the two groups.
Conclusion
The OST was not inferior to 2 L-PEG/ASC in terms of bowel cleansing efficacy and showed better tolerability when used for bowel preparation for colonoscopy.
7.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
8.Efficacy of Oral Sulfate Tablet and 2 L-Polyethylene Glycol With Ascorbic Acid for Bowel Preparation: A Prospective Randomized KASID Multicenter Trial
Yunho JUNG ; Hyun Gun KIM ; Dong-Hoon YANG ; Hyoun Woo KANG ; Jae Jun PARK ; Dong Hoon BAEK ; Jaeyoung CHUN ; Tae-Geun GWEON ; Hyeon Jeong GOONG ; Min Seob KWAK ; Hyun Jung LEE ; Soo-Kyung PARK ; Jong Hoon LEE
Journal of Korean Medical Science 2024;39(48):e301-
Background:
Oral sulfate tablets (OSTs) are bowel preparation agents that combine oral sulfate solution and simethicone. This study compared the efficacy, tolerability, and safety of OST compared to 2 L-polyethylene glycol plus ascorbic acid (2 L-PEG/ASC).
Methods:
This prospective, randomized, controlled, single-blinded, multicenter, noninferiority trial enrolled 211 healthy adults who underwent colonoscopy between May 2020 and September 2022 at 13 university hospitals. The bowel cleansing rate was assessed using the Boston Bowel Preparation Scale (BBPS) and Harefield Cleansing Scale (HCS), and the preparation agents were administered in split regimens.
Results:
The total BBPS score (8.2 ± 1.5 vs. 7.8 ± 1.4, p = 0.040) and the high-quality bowel cleansing rates in the right colon (73.2% vs. 50.5), transverse colon (80.6% vs. 68.0%), and left colon (81.5% vs. 67.0%) on the BBPS were significantly higher in the OST group than in the 2 L-PEG/ASC group. However, the rates of successful cleansing according to BBPS (90.7% vs. 91.2%) and HCS (96.3% vs. 94.2%) did not significantly differ between the two groups.The taste, ease, and amount of consumption of the preparation agent; and willingness to repeat colonoscopy with the same agent (89.8% vs. 78.6%, P = 0.026) were significantly better in the OST group compared to the 2 L-PEG/ASC group. Adverse events and clinically significant laboratory changes were not significantly different between the two groups.
Conclusion
The OST was not inferior to 2 L-PEG/ASC in terms of bowel cleansing efficacy and showed better tolerability when used for bowel preparation for colonoscopy.
9.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
10.The effectiveness of tumor necrosis factor-α blockertherapy in patients with axial spondyloarthritis who failed conventional treatment: a comparative study focused on improvement in ASAS Health Index
Ah-Ra CHOI ; Ki-Jeong PARK ; Ji-Hyoun KANG ; Yu Jeong LEE ; Hyun Hee JANG ; Moon-Ju KIM ; Tae-Jong KIM
Journal of Rheumatic Diseases 2024;31(3):171-177
Objective:
The purpose of this study is to evaluate the impact of tumor necrosis factor (TNF)-α blocker therapy on the Assessment of SpondyloArthritis international Society Health Index (ASAS-HI) among patients who have failed conventional nonsteroidal anti-inflammatory drugs.
Methods:
A comparative study was conducted involving axial spondyloarthritis (axSpA) patients treated with either TNF-α blocker or conventional therapy. Patient data, including demographics, disease characteristics, and ASAS-HI scores, were collected before and after treatment. Statistical analysis was performed to compare changes in ASAS-HI scores between the TNF-α blocker and the conventional therapy group.
Results:
The study population consisted of patients with axSpA, with a mean age of 38.3 years in conventional treatment group and 29.3 years in TNF-α blocker group. Most variables, including C-reactive protein levels, other comorbidities, and disease assessment scores showed no significant difference between groups. Longitudinal analysis within each treatment group from Week 0 to 12 showed no significant change in the conventional treatment group, whereas the TNF-α blocker group experienced a significant reduction in ASAS-HI scores, demonstrating the effectiveness of the treatment. The TNF-α blocker group exhibited a significantly greater improvement in ASAS-HI scores compared to the conventional therapy group. The Bath Ankylosing Spondylitis Functional Index and the Bath Ankylosing Spondylitis Disease Activity Index demonstrated strong positive correlations with ASAS-HI scores, indicating higher disease activity and functional limitation are associated with worse health outcomes in patients.
Conclusion
The research demonstrates that ASAS-HI scores significantly improve with TNF-α blocker therapy in axSpA patients, underscoring ASAS-HI's effectiveness as a tool for evaluating drug responses.

Result Analysis
Print
Save
E-mail