1.Incidence of surgical site infections after transcervical thyroidectomy in patients given antibiotics versus those without antibiotics in a government hospital in the Philippines
Arsenio Claro A. Cabungcal ; Jeric L. Arbizo ; Ana Melissa F. Hilvano-Cabungcal
Acta Medica Philippina 2024;58(6):24-29
Background and Objectives:
Surgical site infection (SSI) makes up the largest single group of postoperative infective complications. For surgeries classified as clean surgeries of the head and neck, such as a thyroidectomy, the routine administration of antimicrobial prophylaxis is not recommended. Despite this, extended usage of antibiotics is common in developing countries. This study evaluated the need for antibiotics in elective transcervical thyroidectomy for the prevention of SSI in a tertiary government hospital in a developing country.
Methods:
This is a retrospective cohort study that included patients who have undergone elective transcervical
thyroidectomy at the Department of Otolaryngology - Head and Neck Surgery (ORL-HNS) of the University of the Philippines - Philippine General (UP-PGH) Hospital from August 1, 2020 to June 30, 2022. Data collection was conducted through review of both in-patient and out-patient records.
Results:
The data of 58 patients were analyzed. The mean (±SD) age was 42.5±14.5 years, with approximately
2:27 male to female ratio. Of the 58 patients, 26 were given postoperative antibiotics while 32 did not receive
postoperative antibiotics. None of the 58 were noted to have SSI on the 3rd postoperative day. Only 54 patients
completed the 7-day follow-up of the study and their data were further analyzed. One patient had SSI. There was no significant difference between the presence and absence of postoperative antibiotics in relation to SSI (p-value>0.05).
Conclusion
This study shows that in patients undergoing transcervical thyroidectomies, there is no significant
difference in the occurrence of SSI among patients who received and did not receive postoperative antibiotics. Therefore, there is no need to administer postoperative antibiotics, as long as a sterile surgical technique is ensured.
Surgical Wound Infection
;
Thyroidectomy
2.Knowledge, attitudes and practices of surgical trainees and trainers on recommended Surgical Site Infection prevention protocols
Esther A. Saguil ; Jose Modesto B. Abellera III ; Daniel Ernest L. Florendo ; George Robert L. Uyquienco
Philippine Journal of Surgical Specialties 2024;79(2):59-74
RATIONALE/OBJECTIVE
This study aimed to determine the knowledge, attitudes and practices of surgeons and surgical trainees regarding published SSI prevention guidelines. Specifically, the study described knowledge and attitudes towards SSI prevention guidelines among members of surgical training programs, described preoperative, intraoperative, and postoperative practices in SSI prevention and identified the presence of surgical site infection surveillance programs among various institutions.
METHODSThis was a retrospective cross-sectional study that evaluated the knowledge, attitudes, and practices of surgeons and surgical trainees to published SSI prevention guidelines in the Philippines. It utilized existing data from an October 2022 online survey done by the Philippine College of Surgeons distributed to various surgical training institutions in the country.
RESULTSThere were a total of 213 respondents. The different attitudes and knowledge gaps towards present SSI prevention guidelines are described.
CONCLUSIONDespite the existence of local and international guidelines there still appears to be a significant lack of awareness and variability in practice among the different institutions as well as with surgeons of different levels of expertise or training. Varying preoperative, intraoperative and postoperative practices have also been described, including evident deviations from SSI guidelines. Lastly, there is a lack of standardized SSI surveillance programs among institutions and these are not aligned towards improved patient safety and quality improvement.
Human ; Surgical Wound Infection
3.Prevalence of and risk factors associated with Methicillin-Resistant Staphylococcus aureus(MRSA) carriage among cutting specialties at the Ospital ng Maynila Medical Center
Michael Robert Q. Monteverde ; Ramon Carmelo V. Alcira
Philippine Journal of Otolaryngology Head and Neck Surgery 2024;39(1):12-18
Objective:
To determine the point prevalence of, and risk factors associated with MRSA carriage among resident physicians of surgical departments at the Ospital ng Maynila Medical Center.
Methods:
Design: Cross-sectional Study. Setting: Tertiary Government Training Hospital. Participants:51 resident physicians from different surgical departments (general surgery, obstetrics and gynecology, ophthalmology, otorhinolaryngology – head and neck surgery and dermatology) underwent nasal and pharyngeal swabs with microbial culture and sensitivity testing to identify MRSA carriers. Fisher Exact Test and logistic regression were utilized to determine associations between MRSA carriage and various risk factors including frequency of hand washing and departmental affiliation.
Results:
Overall prevalence rate of MRSA carriage was 9.8%. Otorhinolaryngology residents had the highest combined prevalence of MRSA of 42.9%, significantly higher compared to other departments and were used as a reference in logistic regression analyses. Notably, handwashing only once daily was associated with a 20-fold increase in the risk of MRSA carriage (OR 20.5, 95% CI: 1.82 to 230, p = .014). Other departments did not demonstrate statistically significant differences in MRSA carriage rates.
Conclusions
Otorhinolaryngology resident physicians had the highest combined prevalence of MRSA and nasal MRSA was found only in otorhinolaryngology residents. The surgical subspecialty and frequency of handwashing of the healthcare worker were identified as important risk factors to develop MRSA carriage. Targeted interventions (including enhanced infection control protocols and regular screening) are needed especially in high-risk departments.
Methicillin-Resistant Staphylococcus aureus
;
Surgical Wound Infection
4.Research Progress in Adjacent Anatomical Structure and Location of Cricothyroid Membrane.
Xu-Min ZHAO ; Qian-Yu WANG ; Quan-le LIU ; Dong YANG
Acta Academiae Medicinae Sinicae 2023;45(4):677-682
Cricothyroid membrane puncture and incision,the key techniques to save the lives of the patients in the Can't Intubate,Can't Oxygenate (CICO) emergency,need to be mastered by all the airway management staff.However,the decision to carry out cricothyroid membrane puncture or incision is often delayed due to the unfamiliarity with the adjacent anatomical structure of the cricothyroid membrane and the inability to accurately locate the cricothyroid membrane.As a result,serious complications and rescue failure occur.Therefore,airway management staff should be familiar with the adjacent structure and positioning methods of the cricothyroid membrane,so as to improve the success rate of emergency airway rescue,reduce complications,and protect the airway and life safety of the patients.
Humans
;
Punctures
;
Surgical Wound
5.Early effectiveness of computer navigation system-assisted transiliac-transsacral screws placement for posterior pelvic ring injuries.
Wenhao CAO ; Zhengguo ZHU ; Hongzhe QI ; Junjun TANG ; Wei ZHANG ; Jiaqi LI ; Shuangcheng LI ; Zhonghe WANG ; Changda LI ; Feng ZHOU ; Haoyang LIU ; Hua CHEN ; Peifu TANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1049-1054
OBJECTIVE:
To investigate the early effectiveness of transiliac-transsacral screws internal fixation assisted by augmented reality navigation system HoloSight (hereinafter referred to as "computer navigation system") in the treatment of posterior pelvic ring injuries.
METHODS:
A retrospective analysis was made in the 41 patients with posterior pelvic ring injuries who had been treated surgically with transiliac-transsacral screws between June 2022 and June 2023. The patients were divided into navigation group (18 cases, using computer navigation system to assist screw implantation) and freehand group (23 cases, using C-arm X-ray fluoroscopy to guide screw implantation) according to the different methods of transiliac-transsacral screws placement. There was no significant difference in gender, age, body mass index, causes of injuries, Tile classification of pelvic fracture, days from injury to operation, usage of unlocking closed reduction technique between the two groups ( P>0.05). The time of screw implantation, the fluoroscopy times, the guide wire adjustment times of each screw, and the incidence of complications were recorded and compared between the two groups. The position of the transiliac-transsacral screw was scanned by CT within 2 days after operation, and the position of the screw was classified according to Gras standard.
RESULTS:
The operation was successfully completed in both groups. The time of screw implantation, the fluoroscopy times, and the guide wire adjustment times of each screw in the navigation group were significantly less than those in the freehand group ( P<0.05). There were 2 cases of incision infection in the freehand group, and the incision healed by first intention after active dressing change; there was no screw-related complication in the navigation group during operation and early period after operation; the difference in incidence of complications between the two groups (8.7% vs. 0) was not significant ( P=0.495). According to the Gras standard, the screw position of the navigation group was significantly better than that of the freehand group ( P<0.05).
CONCLUSION
Compared with the traditional freehand method, the computer navigation system assisted transiliac-transsacral screws internal fixation in the treatment of posterior pelvic ring injuries has advantages of improving the accuracy of screw implantation and reducing radiation damage and the time of screw implantation.
Humans
;
Retrospective Studies
;
Surgical Wound Infection
;
Replantation
;
Body Mass Index
6.Clinical study on a novel minimally invasive Achilles tendon suture instrument for treating fresh closed Achilles tendon rupture.
Shengzhu LU ; Meijuan TAN ; Qiang SUN ; Yanshun KUANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1062-1067
OBJECTIVE:
To assess the effectiveness of a novel minimally invasive Achilles tendon suture instrument in the treatment of fresh closed Achilles tendon rupture.
METHODS:
A retrospective study was conducted on 150 patients who underwent surgical intervention for fresh closed Achilles tendon rupture. Eighty patients were treated with the novel minimally invasive Achilles tendon suture instrument (minimally invasive group) and 70 patients with traditional open surgery (traditional group). The two groups were comparable in terms of gender, age, injured side, cause of injury, the interval between injury and operation, and the distance from the fracture end to the calcaneal tuberosity ( P>0.05). The operation time, intraoperative blood loss, incision length, hospital stays, hospitalization expenses, and complications were recorded and compared. At 1 year after operation, the ankle joint function was evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score.
RESULTS:
The minimally invasive group demonstrated significantly shorter operation time, smaller incision length, and lower intraoperative blood loss when compared with the traditional group ( P<0.05). However, there was no significant difference in terms of hospital stays and hospitalization expenses between the two groups ( P>0.05). All patients were followed up 12-24 months after operation (mean, 15.5 months). In the traditional group, 6 cases of incision necrosis and 7 cases of Achilles tendon adhesion occurred, while in the minimally invasive group, all incisions healed at first intention and no Achilles tendon adhesion occurred. The differences in the incidences of the two complications between the two groups were significant ( P<0.05). At 1 year after operation, the AOFAS ankle-hindfoot score in the minimally invasive group was superior to that of the traditional group ( P<0.05).
CONCLUSION
In comparison with traditional open surgery, the use of self-designed novel minimally invasive Achilles tendon suture instrument proves to be an ideal technique for treating fresh closed Achilles tendon ruptures. This approach offers the benefits of smaller incisions, fewer complications, and better postoperative functional recovery, without increasing hospital costs.
Humans
;
Blood Loss, Surgical
;
Retrospective Studies
;
Neurosurgical Procedures
;
Achilles Tendon/surgery*
;
Tendon Injuries/surgery*
;
Ankle Injuries
;
Surgical Wound
;
Sutures
7.Effectiveness of robot-guided percutaneous fixation and decompression via small incision for advanced thoracolumbar metastases.
Jiahong LI ; Shu LIN ; Liuyi TANG ; Jiang HU ; Lun WAN ; Kun ZHANG ; Weimin LIANG ; Shan WANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1113-1118
OBJECTIVE:
To evaluate the effectiveness of robot-guided percutaneous fixation and decompression via small incision in treatment of advanced thoracolumbar metastases.
METHODS:
A clinical data of 57 patients with advanced thoracolumbar metastases admitted between June 2017 and January 2021 and met the selection criteria was retrospectively analyzed. Among them, 26 cases were treated with robot-guided percutaneous fixation and decompression via small incision (robot-guided group) and 31 cases with traditional open surgery (traditional group). There was no significant difference in gender, age, body mass index, lesion segment, primary tumor site, and preoperative Tokuhashi score, Tomita score, Spinal Instability Neoplastic Score (SINS), visual analogue scale (VAS) score, Oswestry disability index (ODI), Karnofsky score, and Frankel grading between groups ( P>0.05). The operation time, hospital stays, hospital expenses, intraoperative blood loss, postoperative drainage volume, duration of intensive care unit (ICU) stay, blood transfusion, complications, and survival time were compared. The pedicle screw placement accuracy was evaluated according to the Gertzbein-Robbins grading by CT within 4 days after operation. The pain, function, and quality of life were evaluated by VAS score, ODI, Karnofsky score, and Frankel grading.
RESULTS:
During operation, 257 and 316 screws were implanted in the robot-guided group and the traditional group, respectively; and there was no significant difference in pedicle screw placement accuracy between groups ( P>0.05). Compared with the traditional group, the operation time, hospital stays, duration of ICU stay were significantly shorter, and intraoperative blood loss and postoperative drainage volume were significantly lesser in the robot-guided group ( P<0.05). There was no significant difference in hospital expenses, blood transfusion rate, and complications between groups ( P>0.05). All patients were followed up 8-32 months (mean, 14 months). There was no significant difference in VAS scores between groups at 7 days after operation ( P>0.05), but the robot-guided group was superior to the traditional group at 1 and 3 months after operation ( P<0.05). The postoperative ODI change was significantly better in the robot-guided group than in the traditional group ( P<0.05), and there was no significant difference in the postoperative Karnofsky score change and Frankel grading change when compared to the traditional group ( P>0.05). Median overall survival time was 13 months [95% CI (10.858, 15.142) months] in the robot-guided group and 15 months [95% CI (13.349, 16.651) months] in the traditional group, with no significant difference between groups ( χ 2=0.561, P=0.454) .
CONCLUSION
Compared with traditional open surgery, the robot-guided percutaneous fixation and decompression via small incision can reduce operation time, hospital stays, intraoperative blood loss, blood transfusion, and complications in treatment of advanced thoracolumbar metastases.
Humans
;
Blood Loss, Surgical
;
Quality of Life
;
Retrospective Studies
;
Robotics
;
Surgical Wound
;
Decompression
8.Application of hairpin shaped incision combined with cover-lifting flap in plastic surgery of huge fat pad on nape and back.
Mingyue ZHANG ; Wanghaonan CHEN ; Feihong SHU ; Ye LIU ; Kerong TAO ; Chi ZHANG ; Xing YOU ; Guangfeng SUN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1133-1137
OBJECTIVE:
To explore the effectiveness of hairpin shaped incision combined with cover-lifting flap in plastic surgery of huge fat pad on nape and back.
METHODS:
Between March 2019 and March 2023, 10 patients with huge fat pad on the nape and back were treated. There was 1 male and 9 females with an average age of 52 years (range, 39-57 years). All patients had soft tissue bulge on the nape and back. Preoperative MRI showed the subcutaneous fat thickening. The length of the longitudinal axis of the fat pad ranged from 10.0 to 25.0 cm (mean, 14.1 cm), the length of the transverse axis ranged from 6.0 to 15.0 cm (mean, 10.8 cm); the thickness of the fat pad ranged from 2.5 to 5.1 cm (mean, 3.9 cm). Under general anesthesia, the patient was placed in a prone position and a hairpin shaped incision was made. The flap was lifted to remove the fat pad according to the marked area. The dressing was changed every 2 days after operation.
RESULTS:
The operation time was 35-110 minutes (mean, 72 minutes). The intraoperative blood loss was 35-80 mL (mean, 49.5 mL). The drainage tube was removed at 2-5 days after operation (mean, 3.4 days). All incisions healed by first intention without incision dehiscence, infection, subcutaneous bruising, hematoma, or other related complications. All patients were followed up 2-24 months (mean, 12 months). All patients had a good shape of the nape and back and no noticeable scar on the incision. According to the Vancouver Scar Scale evaluation criteria, the incision scar score was 3-5 (mean, 3.7) at 2 months after operation. Patients had good neck movement with no recurrence.
CONCLUSION
For the huge fat pad on the nape and back, the plastic surgery using hairpin shaped incision and cover-lifting flap has the advantages of fully exposing the fat pad, concealed incision, simple operation, and natural shape of the nape and back after operation.
Female
;
Humans
;
Male
;
Middle Aged
;
Surgery, Plastic
;
Cicatrix
;
Lifting
;
Plastic Surgery Procedures
;
Surgical Wound
;
Adipose Tissue
9.Comparison of effectiveness of lower extremity axial distractor and traction table assisted closed reduction and intramedullary nail fixation in femoral subtrochanteric fracture.
Xingkai ZHANG ; Nan ZHOU ; Mingliang MA ; Gangqiang DU ; Zeyue GENG ; Ruifeng QI ; Zhigang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(12):1465-1470
OBJECTIVE:
To compare the effectiveness of lower extremity axial distractor (LEAD) and traction table assisted closed reduction and intramedullary nail fixation in treatment of femoral subtrochanteric fracture.
METHODS:
The clinical data of 117 patients with subtrochanteric fracture of femur treated by closed reduction and intramedullary nail fixation between May 2012 and May 2022 who met the selection criteria were retrospectively analyzed. According to the auxiliary reduction tools used during operation, the patients were divided into LEAD group (62 cases with LEAD reduction) and traction table group (55 cases with traction table reduction). There was no significant difference in baseline data, such as gender, age, injured side, cause of injury, fracture Seinsheimer classification, time from injury to operation, and preoperative visual analogue scale (VAS) score, between the two groups ( P>0.05). Total incision length, operation time, intraoperative blood loss, fluoroscopy frequency, closed reduction rate, fracture reduction quality, fracture healing time, weight-bearing activity time, and incidence of complications, as well as hip flexion and extension range of motion (ROM), Harris score, and VAS score at 1 month and 6 months after operation and last follow-up were recorded and compared between the two groups.
RESULTS:
There were 14 cases in the LEAD group from closed reduction to limited open reduction, and 43 cases in the traction table group. The incisions in the LEAD group healed by first intention, and no complication such as nerve and vascular injury occurred during operation. In the traction table group, 3 cases had perineal crush injury, which recovered spontaneously in 1 week. The total incision length, operation time, intraoperative blood loss, fluoroscopy frequency, and closed reduction rate in the LEAD group were significantly better than those in the traction table group ( P<0.05). There was no significant difference in the quality of fracture reduction between the two groups ( P>0.05). Patients in both groups were followed up 12-44 months, with an average of 15.8 months. In the LEAD group, 1 patient had delayed fracture union at 6 months after operation, 1 patient had nonunion at 3 years after operation, and 1 patient had incision sinus pus flow at 10 months after operation. In the traction table group, there was 1 patient with fracture nonunion at 15 months after operation. X-ray films of the other patients in the two groups showed that the internal fixator was fixed firmly without loosening and the fractures healed. There was no significant difference in fracture healing time, weight bearing activity time, incidence of complications, and postoperative hip flexion and extension ROM, Harris score, and VAS score at different time points between the two groups ( P>0.05).
CONCLUSION
For femoral subtrochanteric fracture treated by close reduction and intramedullary nail fixation, compared with traction table, LEAD assisted fracture reduction can significantly shorten the operation time, reduce intraoperative blood loss and fluoroscopy frequency, reduce incision length, effectively improve the success rate of closed reduction, and avoid complications related to traction table reduction. It provides a new method for good reduction of femoral subtrochanteric fracture.
Humans
;
Fracture Fixation, Intramedullary
;
Bone Nails
;
Traction
;
Blood Loss, Surgical/prevention & control*
;
Retrospective Studies
;
Treatment Outcome
;
Femoral Fractures
;
Hip Fractures/surgery*
;
Lower Extremity
;
Surgical Wound
;
Fracture Fixation, Internal
10.Early effectiveness of Ti-Robot assisted femoral neck system for minimally invasive treatment of elderly Garden type Ⅱ and Ⅲ femoral neck fractures.
Yajun LIU ; Zhaodong WANG ; Chen XU ; Zhonglian ZHU ; Keyou DUAN ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(12):1471-1476
OBJECTIVE:
To investigate the early effectiveness of the Ti-Robot assisted femoral neck system (FNS) in the treatment of elderly Garden type Ⅱ and Ⅲ femoral neck fractures.
METHODS:
A retrospective analysis was conducted on the clinical data of 41 elderly patients with Garden type Ⅱ and Ⅲ femoral neck fractures who were admitted between December 2019 and August 2022 and met the selection criteria. Among them, 21 cases were treated with Ti-Robot assisted FNS internal fixation (study group), and 20 cases were treated solely with FNS internal fixation (control group). There was no significant difference in baseline data, including gender, age, side, cause of injury, time from injury to surgery, fracture Garden classification, and fracture line classification, between the two groups ( P>0.05). Surgical effectiveness was evaluated based on parameters such as operation time (including incision time and total operation time), reduction level, number of dominant pin insertions, intraoperative fluoroscopy frequency, incision length, whether to extend the incision, need for assisted reduction, postoperative hospital stay, fracture healing time, incidence of osteonecrosis of the femoral head, postoperative visual analogue scale (VAS) score at 1 day, and Harris hip score at last follow-up.
RESULTS:
The study group showed significantly shorter incision time, fewer dominant pin insertions, fewer instances of extended incisions, fewer intraoperative fluoroscopy frequency, and smaller incisions than the control group ( P<0.05). There was no significant difference in total operation time, reduction level, and assisted reduction frequency between the two groups ( P>0.05). Both groups achieved primary wound healing postoperatively, with no complications such as incision leakage or skin infection. All patients were followed up 12-24 months with an average of 14.6 months. Fractures healed in both groups, with no significant difference in healing time ( P>0.05). There was no significant difference in postoperative hospital stay between the two groups ( P>0.05). The study group showed significantly better VAS score at 1 day after operation and Harris hip score at last follow-up when compared to the control group ( P<0.05). No complication such as internal fixation failure, fracture displacement, or hip joint varus occurred in both groups during the follow-up. Osteonecrosis of the femoral head occurred in 1 patient of the control group, while no was observed in the study group, and the difference in the incidence of osteonecrosis of the femoral head between the two groups was not significant ( P=0.488).
CONCLUSION
Compared to sole FNS internal fixation treatment, Ti-Robot assisted FNS internal fixation for elderly Garden typeⅡ and Ⅲ femoral neck fractures can reduce incision time, achieve minimally invasive and accurate nail implantation, and decrease intraoperative fluoroscopy frequency, leading to improved postoperative hip joint function recovery.
Humans
;
Aged
;
Femur Neck
;
Robotics
;
Retrospective Studies
;
Treatment Outcome
;
Titanium
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal
;
Osteonecrosis
;
Surgical Wound


Result Analysis
Print
Save
E-mail