1.O-arm navigation versus C-arm navigation for guiding percutaneous long sacroiliac screws placement in treatment of Denis type Ⅱ sacral fractures.
Wei ZHOU ; Guodong WANG ; Xuan PEI ; Zhixun FANG ; Yu CHEN ; Suyaolatu BAO ; Jianan CHEN ; Ximing LIU
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):28-34
OBJECTIVE:
To compare the effectiveness of O-arm navigation and C-arm navigation for guiding percutaneous long sacroiliac screws in treatment of Denis type Ⅱ sacral fractures.
METHODS:
A retrospective study was conducted on clinical data of the 46 patients with Denis type Ⅱ sacral fractures between April 2021 and October 2022. Among them, 19 patients underwent O-arm navigation assisted percutaneous long sacroiliac screw fixation (O-arm navigation group), and 27 patients underwent C-arm navigation assisted percutaneous long sacroiliac screw fixation (C-arm navigation group). There was no significant difference in gender, age, causes of injuries, Tile classification of pelvic fractures, combined injury, the interval from injury to operation between the two groups ( P>0.05). The intraoperative preparation time, the placement time of each screw, the fluoroscopy time of each screw during placement, screw position accuracy, the quality of fracture reduction, and fracture healing time were recorded and compared, postoperative complications were observed. Pelvic function was evaluated by Majeed score at last follow-up.
RESULTS:
All operations were completed successfully, and all incisions healed by first intention. Compared to the C-arm navigation group, the O-arm navigation group had shorter intraoperative preparation time, placement time of each screw, and fluoroscopy time, with significant differences ( P<0.05). There was no significant difference in screw position accuracy and the quality of fracture reduction ( P>0.05). There was no nerve or vascular injury during screw placed in the two groups. All patients in both groups were followed up, with the follow-up time of 6-21 months (mean, 12.0 months). Imaging re-examination showed that both groups achieved bony healing, and there was no significant difference in fracture healing time between the two groups ( P>0.05). During follow-up, there was no postoperative complications, such as screw loosening and breaking or loss of fracture reduction. At last follow-up, there was no significant difference in pelvic function between the two groups ( P>0.05).
CONCLUSION
Compared with the C-arm navigation, the O-arm navigation assisted percutaneous long sacroiliac screws for the treatment of Denis typeⅡsacral fractures can significantly shorten the intraoperative preparation time, screw placement time, and fluoroscopy time, improve the accuracy of screw placement, and obtain clearer navigation images.
Humans
;
Fracture Fixation, Internal/methods*
;
Retrospective Studies
;
Imaging, Three-Dimensional
;
Bone Screws
;
Surgery, Computer-Assisted
;
Tomography, X-Ray Computed
;
Spinal Fractures/surgery*
;
Fractures, Bone/surgery*
;
Pelvic Bones/injuries*
;
Postoperative Complications
;
Neck Injuries
2.Robotic urologic surgery using the KangDuo-Surgical Robot-01 system: A single-center prospective analysis.
Shengwei XIONG ; Shubo FAN ; Silu CHEN ; Xiang WANG ; Guanpeng HAN ; Zhihua LI ; Wei ZUO ; Zhenyu LI ; Kunlin YANG ; Zhongyuan ZHANG ; Cheng SHEN ; Liqun ZHOU ; Xuesong LI
Chinese Medical Journal 2023;136(24):2960-2966
BACKGROUND:
The KangDuo-Surgical Robot-01 (KD-SR-01) system is a new surgical robot recently developed in China. The aim of this study was to present our single-center experience and mid-term outcomes of urological procedures using the KD-SR-01 system.
METHODS:
From August 2020 to April 2023, consecutive urologic procedures were performed at Peking University First Hospital using the KD-SR-01 system. The clinical features, perioperative data, and follow-up outcomes were prospectively collected and analyzed.
RESULTS:
A total of 110 consecutive patients were recruited. Among these patients, 28 underwent partial nephrectomy (PN), 41 underwent urinary tract reconstruction (26 underwent pyeloplasty, 3 underwent ureteral reconstruction and 12 underwent ureterovesical reimplantation [UR]), and 41 underwent radical prostatectomy (RP). The median operative time for PN was 112.5 min, 157.0 min for pyeloplasty, 151.0 min for ureteral reconstruction, 142.5 min for UR, and 138.0 min for RP. The median intraoperative blood loss was 10 mL for PN, 10 mL for pyeloplasty, 30 mL for ureteral reconstruction, 20 mL for UR, and 50 mL for RP. All procedures were successfully completed without conversion, and there were no major complications in any patient. The median warm ischemia time of PN was 17.3 min, and positive surgical margin was not noted in any patient. The overall positive surgical margin rate of RP was 39% (16/41), and no biochemical recurrence was observed in any RP patient during the median follow-up of 11.0 months. The surgical success rates of pyeloplasty and UR were 96% (25/26) and 92% (11/12) during the median follow-up of 29.5 months and 11.5 months, respectively.
CONCLUSION
The KD-SR-01 system appears feasible, safe, and effective for most urological procedures, based on our single-center experience.
Male
;
Humans
;
Robotic Surgical Procedures/methods*
;
Robotics
;
Treatment Outcome
;
Retrospective Studies
;
Ureter/surgery*
;
Urologic Surgical Procedures/methods*
;
Laparoscopy/methods*
3.Simultaneous implantation and tooth preparation technology guided by 3D-printed guide.
Nan HU ; Chunxu LIU ; Jing GAO ; Chenyang XIE ; Jiayi YU ; Luming JIA ; Haiyang YU
West China Journal of Stomatology 2023;41(4):483-490
Using digital technologies in concurrently performing missing tooth implantation and preparation of remaining teeth is a solution to reduce the number of visits and improve efficiency. This paper proposes a digital process for simultaneously implanting and preparing teeth. It integrates implant surgical guide and 3D-printed tooth preparation guide into a single guide and completes guided implant placement and precise tooth preparation. Based on "repair-oriented" virtual implant planning, the implant surgical guide can improve the efficiency and predictability of implant placement, and its linear accuracy is about 1 mm. The tooth preparation guide precisely guides tooth preparation and restoration space visualization, ensuring the quality of the tooth preparation. The two guides have different design accuracy requirements, and thus their combination improves the overall guiding accuracy requirements. The concurrent application of the two guides minimizes the clinical operation time, number of visits, and economic burden of patients.
Humans
;
Surgery, Computer-Assisted
;
Dental Implantation, Endosseous
;
Printing, Three-Dimensional
;
Technology
;
Tooth Preparation
;
Computer-Aided Design
;
Dental Implants
;
Imaging, Three-Dimensional
;
Cone-Beam Computed Tomography
4.From "Empirical Surgery" to "Precision Surgery": establishment and clinical application of precision orthognathic surgery system.
Xudong WANG ; Hongpu WEI ; Biao LI
West China Journal of Stomatology 2023;41(5):491-501
Orthognathic surgery, which involve osteotomy and repositioning of the maxillomandibular complex, has recently emerged as a crucial method of correcting dentofacial deformities. The optimal placement of the maxillomandibular complex holds utmost significance during orthognathic surgery because it directly affects the surgical outcome. To accurately achieve the ideal position of the maxillomandibular complex, with the rapid advancements in digital surgery and 3D-printing technology, orthognathic surgery has entered an era of "Precision Surgery" from the pervious "Empirical Surgery." This article provides comprehensive insights into our extensive research and exploration of the treatment modality known as "precision orthognathic surgery" over the years. We also present the technical system and application in"Ortho+X" treatment modality to offer valuable references and assistance to our colleagues in the field.
Orthognathic Surgery
;
Orthognathic Surgical Procedures
;
Printing, Three-Dimensional
;
Surgery, Computer-Assisted
5.Clinical application of percutaneous pedicle screw placement guided by ultrasound volume navigation combined with X-ray fluoroscopy: a prospective randomized controlled study.
Xuxin LIN ; Lijie SHANG ; Suhong SHEN ; Qingfeng WANG ; Xiaoyan FU ; Gang ZHAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1253-1258
OBJECTIVE:
To explore the feasibility and accuracy of ultrasound volume navigation (UVN) combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation through a prospective randomized controlled study.
METHODS:
Patients with thoracic and lumbar vertebral fractures scheduled for percutaneous pedicle screw fixation between January 2022 and January 2023 were enrolled. Among them, 60 patients met the selection criteria and were included in the study. There were 28 males and 32 females, with an average age of 49.5 years (range, 29-60 years). The cause of injury included 20 cases of traffic accidents, 21 cases of falls, 17 cases of slips, and 2 cases of heavy object impact. The interval from injury to hospital admission ranged from 1 to 5 days (mean, 1.57 days). The fracture located at T 12 in 15 cases, L 1 in 20 cases, L 2 in 19 cases, and L 3 in 6 cases. The study used each patient as their own control, randomly guiding pedicle screw implantation using UVN combined with X-ray fluoroscopy on one side of the vertebral body and the adjacent segment (trial group), while the other side was implanted under X-ray fluoroscopy (control group). A total of 4 screws and 2 rods were implanted in each patient. The implantation time and fluoroscopy frequency during implantation of each screw, angle deviation and distance deviation between actual and preoperative planned trajectory by imaging examination, and the occurrence of zygapophysial joint invasion were recorded.
RESULTS:
In terms of screw implantation time, fluoroscopy frequency, angle deviation, distance deviation, and incidence of zygapophysial joint invasion, the trial group showed superior results compared to the control group, and the differences were significant ( P<0.05).
CONCLUSION
UVN combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation can yreduce screw implantation time, adjust dynamically, reduce operational difficulty, and reduce radiation damage.
Male
;
Female
;
Humans
;
Middle Aged
;
Pedicle Screws
;
Prospective Studies
;
X-Rays
;
Surgery, Computer-Assisted/methods*
;
Spinal Fusion/methods*
;
Fluoroscopy/methods*
;
Lumbar Vertebrae/injuries*
6.Comparison of screw placement guided by O-arm navigation and ultrasound volume navigation in minimally invasive transforaminal lumbar interbody fusion.
Xuxin LIN ; Qing CHANG ; Lijie SHANG ; Suhong SHEN ; Zhuo FU ; Yifan WANG ; Lufan ZHOU ; Hao FU ; Gang ZHAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(11):1403-1409
OBJECTIVE:
To compare the effectiveness of O-arm navigation and ultrasound volume navigation (UVN) in guiding screw placement during minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) surgery.
METHODS:
Sixty patients who underwent MIS-TLIF surgery for lumbar disc herniation between June 2022 and June 2023 and met the selection criteria were included in the study. They were randomly assigned to group A (screw placement guided by UVN during MIS-TLIF) or group B (screw placement guided by O-arm navigation during MIS-TLIF), with 30 cases in each group. There was no significant difference in baseline data, including gender, age, body mass index, and surgical segment, between the two groups ( P>0.05). Intraoperative data, including average single screw placement time, total radiation dose, and average single screw effective radiation dose, were recorded and calculated. Postoperatively, X-ray film and CT scans were performed at 10 days to evaluate screw placement accuracy and assess facet joint violation. Pearson correlation and Spearman correlation analyses were used to observe the relationship between the studied parameters (average single screw placement time and screw placement accuracy grading) and BMI.
RESULTS:
The average single screw placement time in group B was significantly shorter than that in group A, and the total radiation dose of single segment and multi-segment and the average single screw effective radiation dose in group B were significantly higher than those in group A ( P<0.05). There was no significant difference in the total radiation dose between single segment and multiple segments in group B ( P>0.05), while the total radiation dose of multiple segments was significantly higher than that of single segment in group A ( P<0.05). No significant difference was found in the accuracy of screw implantation between the two groups ( P>0.05). In both groups, the grade 1 and grade 2 screws broke through the outer wall of the pedicle, and no screw broke through the inner wall of the pedicle. There was no significant difference in the rate of facet joint violation between the two groups ( P>0.05). In group A, both the average single screw placement time and screw placement accuracy grading were positively correlated with BMI ( r=0.677, P<0.001; r=0.222, P=0.012), while in group B, neither of them was correlated with BMI ( r=0.224, P=0.233; r=0.034, P=0.697).
CONCLUSION
UVN-guided screw placement in MIS-TLIF surgery demonstrates comparable efficiency, visualization, and accuracy to O-arm navigation, while significantly reducing radiation exposure. However, it may be influenced by factors such as obesity, which poses certain limitations.
Humans
;
Imaging, Three-Dimensional
;
Lumbar Vertebrae/surgery*
;
Minimally Invasive Surgical Procedures
;
Pedicle Screws
;
Retrospective Studies
;
Spinal Fusion
;
Surgery, Computer-Assisted
;
Tomography, X-Ray Computed
;
Treatment Outcome
7.Application and research progress of artificial intelligence technology in trauma treatment.
Heng ZHANG ; Xiaodong MA ; Jiaqin WANG ; Jianzhong GUAN ; Kuanxin LI ; Jianning ZHAO ; Jiansheng ZHOU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(11):1431-1437
OBJECTIVE:
To review the application and research progress of artificial intelligence (AI) technology in trauma treatment.
METHODS:
The recent research literature on the application of AI and related technologies in trauma treatment was reviewed and summarized in terms of prehospital assistance, in-hospital emergency care, and post-traumatic stress disorder risk regression prediction, meanwhile, the development trend of AI technology in trauma treatment were outlooked.
RESULTS:
The AI technology can rapidly analyze and manage large amount of clinical data to help doctors identify patients' situation of trauma and predict the risk of possible complications more accurately. The application of AI technology in surgical assistance and robotic operations can achieve precise surgical plan and treatment, reduce surgical risks, and shorten the operation time, so as to improve the efficiency and long-term effectiveness of the trauma treatment.
CONCLUSION
There is a promising future for the application of AI technology in the trauma treatment. However, it is still in the stage of exploration and development, and there are many difficulties of historical data bias, application condition limitations, as well as ethical and moral issues need to be solved.
Humans
;
Artificial Intelligence
;
Operative Time
;
Robotic Surgical Procedures
;
Technology
8.Uncalibrated Positioning Method for Puncture Robots Based on Optical Navigation.
Qiwan WANG ; Ting FENG ; Rongqian YANG ; Yinwei ZHAN
Chinese Journal of Medical Instrumentation 2023;47(6):591-597
Robotic puncture system has been widely used in modern minimally invasive surgery, which usually uses hand-eye calibration to calculate the spatial relationship between the robot and the optical tracking system. However, the hand-eye calibration process is time-consuming and sensitive to environmental changes, which makes it difficult to guarantee the puncture accuracy of the robot. This study proposes an uncalibrated positioning method for puncture robot based on optical navigation. The method divides the target path positioning into two stages, angle positioning and position positioning, and designs angle image features and position image features respectively. The corresponding image Jacobian matrix is constructed based on the image features and updated by online estimation with a cubature Kalman filter to drive the robot to perform target path localization. The target path positioning results show that the method is more accurate than the traditional hand-eye calibration method and saves significant preoperative preparation time by eliminating the need for calibration.
Robotics
;
Robotic Surgical Procedures
;
Calibration
;
Minimally Invasive Surgical Procedures
;
Optical Devices
9.New progress in the surgical treatment of laryngeal cyst in infants and children.
Huiying LV ; Yihua NI ; Chao CHEN ; Wenxia CHEN ; Zhengmin XU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(12):968-971
Laryngeal cyst is a cystic lesion occurring in the laryngeal cavity. Large laryngeal cyst in infants and young children can cause laryngeal wheezing and other upper airway obstruction symptoms. In severe cases, it can be even life-threatening and requires timely surgical treatment. Currently, there is a lack of unified clinical treatment strategy for this disease.This article summarizes the surgical methods, the advantages and disadvantages of various surgical methods for laryngeal cysts in recent years. It is recommended that needle aspiration, partial cyst wall resection, radical cyst dissection, transoral robotic surgery or external approach cyst resection should be selected through full communication and evaluation to clarify the extent of the lesion scope and the advantages and disadvantages of surgery.
Infant
;
Child
;
Humans
;
Child, Preschool
;
Cysts/diagnosis*
;
Laryngeal Diseases/diagnosis*
;
Larynx/surgery*
;
Robotic Surgical Procedures
;
Biopsy, Needle
10.Robot-assisted single lung transplantation.
Wenjie JIAO ; Ronghua YANG ; Yandong ZHAO ; Nan GE ; Tong QIU ; Xiao SUN ; Yingzhi LIU ; Kun LI ; Zhiqiang LI ; Wencheng YU ; Yi QIN ; Ao LIU
Chinese Medical Journal 2023;136(3):362-364

Result Analysis
Print
Save
E-mail