1.Clinical Outcomes of Arthroscopic Rotator Cuff Repair Using Poly Lactic-co-glycolic Acid Plus β-tricalcium Phosphate Biocomposite Suture Anchors
Seok Won CHUNG ; Kyung Soo OH ; Sung Jin KANG ; Jong Pil YOON ; Joon Yub KIM
Clinics in Shoulder and Elbow 2018;21(1):22-29
BACKGROUND: This study is performed to evaluate anchor-related outcomes and complications after arthroscopic rotator cuff repair using 30% β-tricalcium phosphate (β-TCP) with 70% poly lactic-co-glycolic acid (PLGA) biocomposite suture anchors. METHODS: A total of 78 patients (mean age, 61.3 ± 6.9 years) who underwent arthroscopic medium-to-large full-thickness rotator cuff tear repair were enrolled. The technique employed 30% β-TCP with 70% PLGA biocomposite suture anchors at the medial row (38 patients, Healix BRTM anchor [Healix group]; 40 patients, Fixone anchor B [Fixone group]). The radiologic outcomes (including perianchor cyst formation or bone substitution) and anatomical outcomes of the healing failure rate were evaluated using magnetic resonance imaging at least 6 months after surgery, the pain visual analogue scale at 3, 6 months, and final follow-up visit, and American Shoulder and Elbow Surgeons scores at least 1 year postoperatively. Anchor-related complications were also evaluated. RESULTS: The perianchor cyst formation incidence was similar for both groups (60.5%, Healix group; 60.0%, Fixone group; p=0.967), although severe perianchor cyst incidence was slightly lower in the Fixone group (15.0%) than in the Healix group (21.1%). There was no occurrence of anchor absorption and bone substitution. No differences were observed in the healing failure rate (13.2%, Healix group; 15.0%, Fixone group; p=0.815) and functional outcome between groups (all p>0.05). Anchor breakage occurred in 5 patients (2 Healix anchors and 3 Fixone anchors); however, there were no major anchor-related complications in either group. CONCLUSIONS: No differences were observed in the clinical outcomes of the Healix and Fixone groups, neither were there any accompanying major anchor-related complications.
Absorption
;
Elbow
;
Follow-Up Studies
;
Humans
;
Incidence
;
Magnetic Resonance Imaging
;
Rotator Cuff
;
Shoulder
;
Surgeons
;
Suture Anchors
;
Sutures
;
Tears
2.Single-incision laparoscopic cholecystectomy using instrumental alignment in robotic single-site cholecystectomy.
Sung Yub JEONG ; Jin Woo LEE ; Sung Hoon CHOI ; Sung Won KWON
Annals of Surgical Treatment and Research 2018;94(6):291-297
PURPOSE: There is no standardized single-incision laparoscopic cholecystectomy (SILC) technique in contrast to robot single-site cholecystectomy (RSSC). We tried to implement the array of instruments used in RSSC to SILC. METHODS: A series of 108 consecutive patients underwent SILC between September 2014 and July 2017 by 2 surgeons. The indication was benign disease of the gallbladder. The perioperative outcomes were reviewed. We used the 4-channel Glove port and conventional laparoscopic instruments. RESULTS: The study subjects consisted of 29 males and 79 females, and the mean age was 44.4 years (range, 16–70 years). Mean body mass index was 24.1 kg/m2. The mean working time was 25.0 ± 10.7 minutes and total operation time was 44.4 ± 12.4 minutes. There were 7 cases of conversion (additional 1 port in 4 patients, additional 2 ports in 2, and conventional 4 port technique in 1). Bile spillage from the gallbladder during the procedure occurred in 17 (15.7%). There were no postoperative complications. Postoperative hospital stay was 2.0 ± 0.6 days. CONCLUSION: The alignment of the instruments in a RSSC was successfully implemented into a SILC, so that an equally effective operation was possible.
Bile
;
Body Mass Index
;
Cholecystectomy*
;
Cholecystectomy, Laparoscopic*
;
Female
;
Gallbladder
;
Humans
;
Laparoscopy
;
Length of Stay
;
Male
;
Minimally Invasive Surgical Procedures
;
Postoperative Complications
;
Robotics
;
Surgeons
3.Effectiveness and Safety of Biolimus A9™-Eluting stEnt in Patients with AcUTe Coronary sYndrome; A Multicenter, Observational Study (BEAUTY Study)
Keun Ho PARK ; Myung Ho JEONG ; Young Joon HONG ; Youngkeun AHN ; Hyun Kuk KIM ; Young Yub KOH ; Doo Il KIM ; Sang Wook KIM ; Weon KIM ; Seung Woon RHA ; Jay Young RHEW ; Jong Seon PARK ; Hun Sik PARK ; Jang Ho BAE ; Jang Whan BAE ; Seok Kyu OH ; Sung Yun LEE ; Seung Wook LEE ; Jae Hwan LEE ; Sang Yeob LIM ; Jang Hyun CHO ; Kwang Soo CHA ; Jai Keon CHAE ; Seung Ho HUR ; Sun Ho HWANG ; Jin Yong HWANG
Yonsei Medical Journal 2018;59(1):72-79
PURPOSE: This study sought to determine the 1-year clinical effectiveness and safety of a biodegradable, polymer-containing Biolimus A9™-eluting stent (BES) in Korean patients with acute coronary syndrome (ACS). MATERIALS AND METHODS: A total of 1000 ACS patients with 1251 lesions who underwent implantation of BESs at 22 centers in Korea were enrolled between May 2011 and July 2013. We assessed major adverse cardiac events (MACE) defined as the composite of cardiac death, non-fatal myocardial infarction (MI), and clinical-driven target vessel revascularization at 12 months. RESULTS: Patient mean age was 62.6±11.4 years. 72.8% of the patients were male, 28.5% had diabetes, 32.8% had multi-vessel disease (MVD), and 47.9% presented with acute MI (AMI). The mean global registry of acute coronary events risk score of all patients was 103.0±27.6. The number of stents per patient was 1.3±0.6. The incidences of MACE and definite stent thrombosis at 12 months were 3.9% and 0.2%, respectively. On multivariate Cox-regression analysis, age ≥65 years was identified as an independent predictors of 1-year MACE (hazard ratio=2.474; 95% confidence interval=1.202−5.091). Subgroup analyses revealed no significant differences in the incidence of MACE between patients with and without diabetes (4.3% vs. 3.7%, p=0.667), between those who presented with and without AMI (4.4% vs. 3.4%, p=0.403), and between those with and without MVD (4.6% vs. 3.5%, p=0.387). CONCLUSION: Our study demonstrated excellent 1-year clinical outcomes of BES implantation in patients at low-risk for ACS.
Acute Coronary Syndrome/drug therapy
;
Aged
;
Drug-Eluting Stents/adverse effects
;
Female
;
Humans
;
Incidence
;
Kaplan-Meier Estimate
;
Male
;
Middle Aged
;
Multivariate Analysis
;
Proportional Hazards Models
;
Republic of Korea
;
Sirolimus/adverse effects
;
Sirolimus/analogs & derivatives
;
Sirolimus/therapeutic use
;
Time Factors
;
Treatment Outcome
4.Poloxamer 407 Hydrogels for Intravesical Instillation to Mouse Bladder: Gel-Forming Capacity and Retention Performance.
Sang Hyun KIM ; Sung Rae KIM ; Ho Yub YOON ; In Ho CHANG ; Young Mi WHANG ; Min Ji CHO ; Myeong Joo KIM ; Soo Yeon KIM ; Sang Jin LEE ; Young Wook CHOI
Korean Journal of Urological Oncology 2017;15(3):178-186
PURPOSE: Poloxamer 407 (P407) thermo-sensitive hydrogel formulations were developed to enhance the retention time in the urinary bladder after intravesical instillation. MATERIALS AND METHODS: P407 hydrogels (P407Gels) containing 0.2 w/w% fluorescein isothiocyanate dextran (FD, MW 4 kDa) as a fluorescent probe were prepared by the cold method with different concentrations of the polymer (20, 25, and 30 w/w%). The gel-forming capacities were characterized in terms of gelation temperature (G-Temp), gelation time (G-Time), and gel duration (G-Dur). Homogenous dispersion of the probe throughout the hydrogel was observed by using fluorescence microscopy. The in vitro bladder simulation model was established to evaluate the retention and drug release properties. P407Gels in the solution state were administered to nude mice via urinary instillation, and the in vivo retention behavior of P407Gels was visualized by using an in vivo imaging system (IVIS). RESULTS: P407Gels showed a thermo-reversible phase transition at 4℃ (refrigerated; sol) and 37℃ (body temperature; gel). The G-Temp, G-Time, and G-Dur of FD-free P407Gels were approximately 10℃–20℃, 12–30 seconds, and 12–35 hours, respectively, and were not altered by the addition of FD. Fluorescence imaging showed that FD was spread homogenously in the gelled P407 solution. In a bladder simulation model, even after repeated periodic filling-emptying cycles, the hydrogel formulation displayed excellent retention with continuous release of the probe over 8 hours. The FD release from P407Gels and the erosion of the gel, both of which followed zero-order kinetics, had a linear relationship (r²=0.988). IVIS demonstrated that the intravesical retention time of P407Gels was over 4 hours, which was longer than that of the FD solution ( < 1 hour), even though periodic urination occurred in the mice. CONCLUSIONS: FD release from P407Gels was erosion-controlled. P407Gels represent a promising system to enhance intravesical retention with extended drug delivery.
Administration, Intravesical*
;
Animals
;
Dextrans
;
Drug Liberation
;
Fluorescein
;
Hydrogel*
;
Hydrogels*
;
In Vitro Techniques
;
Kinetics
;
Methods
;
Mice*
;
Mice, Nude
;
Microscopy, Fluorescence
;
Optical Imaging
;
Phase Transition
;
Poloxamer*
;
Polymers
;
Urinary Bladder*
;
Urination
5.Surgical Treatment Guidelines for Patients with Differentiated Thyroid Cancer: The Korean Association of Thyroid and Endocrine Surgeons (KATES) Guidelines Taskforce.
Jin Woo PARK ; Ki Wook CHUNG ; Ji Sup YUN ; Hyungju KWON ; Hoon Yub KIM ; Kee Hyun NAM ; Kyoung Sik PARK ; Min Ho PARK ; Ja Sung BAE ; Hyun Jo YOUN ; Kyu Eun LEE ; Chi Young LIM ; Jin Hyang JUNG ; Jun Ho CHOE ; Lee Su KIM ; Su Jung LEE ; Jung Han YOON
Korean Journal of Endocrine Surgery 2017;17(1):1-18
No abstract available.
Humans
;
Surgeons*
;
Thyroid Gland*
;
Thyroid Neoplasms*
6.A Randomized Phase II Trial of Capecitabine Plus Vinorelbine Followed by Docetaxel Versus Adriamycin Plus Cyclophosphamide Followed by Docetaxel as Neoadjuvant Chemotherapy for Breast Cancer.
Changhoon YOO ; Sung Bae KIM ; Jin Hee AHN ; Jeong Eun KIM ; Kyung Hae JUNG ; Gyung Yub GONG ; Byung Ho SON ; Sei Hyun AHN ; Seung Do AHN ; Hak Hee KIM ; Hee Jung SHIN ; Woo Kun KIM
Cancer Research and Treatment 2015;47(3):406-415
PURPOSE: Given the promising activity of capecitabine and vinorelbine in metastatic breast cancer, this randomized phase II trial evaluated the efficacy and safety of this combination as neoadjuvant chemotherapy in breast cancer. MATERIALS AND METHODS: Patients with operable breast cancer (n=75) were randomly assigned to receive either four cycles of adriamycin 60 mg/m2 plus cyclophosphamide 600 mg/m2 every 3 weeks followed by four cycles of docetaxel 75 mg/m2 every 3 weeks (AC-D) or four cycles of capecitabine 2,000 mg/m2 (day 1-14) plus vinorelbine 25 mg/m2 (days 1 and 8) every 3 weeks followed by four cycles of docetaxel 75 mg/m2 (CV-D). The primary endpoint was pathologic complete response (pCR) in the primary breast (ypT0/is). RESULTS: Most patients (84%) had locally advanced (n=41) or inflammatory breast cancer (n=22). pCR rates in the primary breast were 15% (95% confidence interval [CI], 7% to 30%) and 11% (95% CI, 4% to 26%) in the AC-D and CV-D groups, respectively. The overall response rates and 5-year progression-free survival rates in the AC-D and CV-D groups were 62% and 64%, and 51.3% (95% CI, 34.6% to 68.0%) and 30.2% (95% CI, 13.3% to 47.1%), respectively. Although both regimens were well tolerated, CV-D showed less frequent grade 3-4 neutropenia and vomiting than AC-D, whereas manageable diarrhea and hand-foot syndrome were more common in the CV-D group. CONCLUSION: CV-D is a feasible and active non-anthracycline-based neoadjuvant chemotherapy regimen for breast cancer.
Anthracyclines
;
Breast
;
Breast Neoplasms*
;
Cyclophosphamide*
;
Diarrhea
;
Disease-Free Survival
;
Doxorubicin*
;
Drug Therapy*
;
Hand-Foot Syndrome
;
Humans
;
Inflammatory Breast Neoplasms
;
Neoadjuvant Therapy
;
Neutropenia
;
Polymerase Chain Reaction
;
Vomiting
7.Prevalence Study of Adolescent Idiopathic Scoliosis in Ten-, Eleven-Year Olds for 10 Years.
Ki Chan AN ; Dae Hyun PARK ; Gyu Min KONG ; Joo Yong KIM ; Sung Yub JIN ; Woon Seong LEE ; Dae You KIM ; Eun Jung HA ; Kyu Yeol LEE ; Weon Wook PARK ; Jung Sub LEE
The Journal of the Korean Orthopaedic Association 2015;50(1):25-30
PURPOSE: School screening for adolescent idiopathic scoliosis (AIS) was conducted for 10 years and the prevalence of scoliosis as well as the size and types of curvature were investigated. The outcomes and existing research results were comparatively analyzed and the usefulness of the moire topography as a screening tool was evaluated. MATERIALS AND METHODS: Moire topography was used in screening of 413,351 10- and 11-year-old from 2002 to 2011; simple standing entire spine x-rays of selected examinees were taken. When the Cobb angle was 10degrees or higher, the condition was deemed to be scoliosis, and the size, location, and types of curvature were recorded. RESULTS: The average prevalence over the 10 years was 0.4% (0.3%-0.5%) and the trends in yearly prevalence did not change significantly. The ratio of boys-to-girls prevalence rates for the 10 years was 1.0:3.8. The rate of those with scoliosis whose curvature was 10degrees-19degrees, 20degrees-29degrees, and 30degrees-39degrees was 71%, 24%, and 4%, respectively. King-Moe type III accounted for the largest portion at 45%, followed by type IV at 35%, type II at 11%, type I at 7%, and type V at 5%. CONCLUSION: The prevalence of scoliosis in the subjects was similar for the 10 years but differed from previous research results. The size, location, and types of curvature were similar to those reported in previous research. The differences in prevalence from existing research are considered to be due to the screening method used. Therefore, conduction of additional research on effective screening tests is necessary.
Adolescent*
;
Child
;
Cross-Sectional Studies*
;
Humans
;
Mass Screening
;
Moire Topography
;
Prevalence
;
Scoliosis*
;
Spine
8.Long-Term (Postnatal Day 70) Outcome and Safety of Intratracheal Transplantation of Human Umbilical Cord Blood-Derived Mesenchymal Stem Cells in Neonatal Hyperoxic Lung Injury.
So Yoon AHN ; Yun Sil CHANG ; Soo Yoon KIM ; Dong Kyung SUNG ; Eun Sun KIM ; So Yub RIME ; Wook Joon YU ; Soo Jin CHOI ; Won Il OH ; Won Soon PARK
Yonsei Medical Journal 2013;54(2):416-424
PURPOSE: This study was performed to evaluate the long-term effects and safety of intratracheal (IT) transplantation of human umbilical cord blood-derived mesenchymal stem cells (hUCB-MSCs) in neonatal hyperoxic lung injury at postnatal day (P)70 in a rat model. MATERIALS AND METHODS: Newborn Sprague Dawley rat pups were subjected to 14 days of hyperoxia (90% oxygen) within 10 hours after birth and allowed to recover at room air until sacrificed at P70. In the transplantation groups, hUCB-MSCs (5x10(5)) were administered intratracheally at P5. At P70, various organs including the heart, lung, liver, and spleen were histologically examined, and the harvested lungs were assessed for morphometric analyses of alveolarization. ED-1, von Willebrand factor, and human-specific nuclear mitotic apparatus protein (NuMA) staining in the lungs and the hematologic profile of blood were evaluated. RESULTS: Impaired alveolar and vascular growth, which evidenced by an increased mean linear intercept and decreased amount of von Willebrand factor, respectively, and the hyperoxia-induced inflammatory responses, as evidenced by inflammatory foci and ED-1 positive alveolar macrophages, were attenuated in the P70 rat lungs by IT transplantation of hUCB-MSCs. Although rare, donor cells with human specific NuMA staining were persistently present in the P70 rat lungs. There were no gross or microscopic abnormal findings in the heart, liver, or spleen, related to the MSCs transplantation. CONCLUSION: The protective and beneficial effects of IT transplantation of hUCB-MSCs in neonatal hyperoxic lung injuries were sustained for a prolonged recovery period without any long-term adverse effects up to P70.
Animals
;
*Cord Blood Stem Cell Transplantation
;
Ectodysplasins/metabolism
;
Humans
;
Hyperoxia/*pathology
;
Lung/metabolism/pathology
;
Lung Injury/pathology/*surgery
;
*Mesenchymal Stem Cell Transplantation
;
Models, Animal
;
Nuclear Matrix-Associated Proteins/metabolism
;
Rats
;
Trachea/*transplantation
;
von Willebrand Factor/metabolism
9.Functional Outcomes of Percutaneous K-Wire Fixation for Distal Radius Fractures with or without Osteoporosis.
Ki Chan AN ; Gyu Min KONG ; Jang Seok CHOI ; Hi Chul GWAK ; Joo Yong KIM ; Sung Yub JIN
Journal of the Korean Fracture Society 2013;26(4):248-253
PURPOSE: To determine the influence of osteoporosis on the results of percutaneous K-wire fixation for distal radius fractures. MATERIALS AND METHODS: Between March 2007 and February 2011, Fifty seven patients who underwent fixative surgery with K-wires after closed reduction and those available for follow-up for at least 6 months were reviewed. They were divided into the two groups of T score -3 or more (group 1) and T score less than -3 (group 2). These groups were compared by the range of motion of the wrist and Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiologic evaluations consisting of radial length, radial inclination and volar tilt were compared. In group 1 with 34 cases, the average age was 65.4 years (50 to 78 years) and T score was -1.97 (-0.1 to -2.93). In group 2 with 23 cases, the average age was 74 years (54 to 89 years) and T score was -4.11 (-3.1 to -6.97). RESULTS: There was no statistical difference between group 1 and group 2 in terms of range of motion, DASH score and radiologic evaluations. CONCLUSION: In the case of no volar side cortical comminution, percutaneous K-wire fixation can be applied for the treatment of distal radius fracture with osteoporosis.
Arm
;
Follow-Up Studies
;
Hand
;
Humans
;
Osteoporosis*
;
Radius Fractures*
;
Radius*
;
Range of Motion, Articular
;
Shoulder
;
Wrist
10.Clinical Results Comparing Transtibial Technique and Outside in Technique in Single Bundle Anterior Cruciate Ligament Reconstruction
Seung Suk SEO ; Chang Wan KIM ; Jeon Gyo KIM ; Sung Yub JIN
The Journal of Korean Knee Society 2013;25(3):133-140
PURPOSE: To compare the clinical results of single-bundle anterior cruciate ligament (ACL) reconstruction using the conventional transtibial technique and the anatomical outside-in technique for femoral tunneling. MATERIALS AND METHODS: From 2007 to 2011, 89 patients who received ACL reconstruction were followed for > or =1 year were enrolled in the study. The conventional transtibial technique was used in 41 patients and the outside-in technique, in 48 patients. Femoral tunnel angle measurement and three-dimensional computed tomography (3D CT) were used for radiologic assessment of the location of femoral tunnel and Lysholm score and other tests were used for clinical assessment. RESULTS: Both techniques did not reveal statistical differences in the clinical assessment. However, in International Knee Documentation Committee subjective knee evaluation, the sum of two questionnaire items regarding instability showed a statistically significant difference (p=0.01). In the pivot shift test, the anatomical outside-in technique showed outstanding rotational stability over the transtibial technique (p=0.04). The mean femoral tunnel inclination in coronal plane were 69.2degrees and 30.3degrees, respectively, for both techniques, and 21.6degrees and 50.8degrees, respectively in sagittal plane, showing statistically significant differences on simple radiography (p=0.04, 0.05). A 3D CT was performed in 17 patients with the conventional transtibial technique and 25 patients with the outside-in technique. Coefficients of variation were 0.33 and 0.13, respectively, from dorsal border of the condyle and 0.67 and 0.24, respectively, from the roof of intercondylar notch. CONCLUSIONS: Femoral tunnels created with the outside-in technique have superior knee joint rotational stability compare to the transtibial technique. Therefore, the outside-in technique could be considered as a valuable technique in single-bundle ACL reconstruction.
Anterior Cruciate Ligament
;
Anterior Cruciate Ligament Reconstruction
;
Humans
;
Knee
;
Knee Joint
;
Surveys and Questionnaires

Result Analysis
Print
Save
E-mail