1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6. Research on the dynamic changes of neurological dysfunction and cognitive function impairment in traumatic brain injury
Cheng-Gong ZOU ; Hao FENG ; Bing CHEN ; Hui TANG ; Chuan SHAO ; Mou SUN ; Rong YANG ; Jia-Quan HE
Acta Anatomica Sinica 2024;55(1):43-48
Objective To explore the dynamic changes and mechanisms of neurological and cognitive functions in mice with traumatic brain injury (TBI). Methods Totally 60 12⁃month⁃old Balb/ c mice were divided into control group (10 in group) and TBI group (50 in group). TBT model mice were divided into 5 subgroups according to the time of model construction, including model 1 day, model 1 day, model 3 day, model 7 day, model 14 days and model 28 days group with 10 in each group. At the 29th day of the experiment, neurological scores and step down tests were carried out. After the test, the mice were sacrificed for brains which were detected by immunohistochemistry staining, inflammatory cytokine tests and Western blotting. Results Compared with the control group, the neurological scores of mice in TBI group increased, and then decreased after the 7th day when the scores reached the peak. However, the latency of step down errors was lower than control group, and the number of step down errors was higher than control group which had no changes. Compared with the control group, the expression of lonized calcium⁃binding adapter molecule 1(IBA1), chemokine C⁃X3⁃C⁃motif ligand1 (CX3CL1), C⁃X3⁃C chemokine receptor 1(CX3CR1), NOD⁃like receptor thermal protein domain associated protein 3 (NLRP3), and phosphorylation nuclear factor(p⁃NF)⁃κB in TBI group increased and reached to the peak at the 7th day, and then started to decrease. At the same time, the levels of inflammatory cytokines interleukin⁃6(IL⁃6) and tumor necrosis factor⁃α(TNF⁃α) first increased to the peak, and then began to decrease. However, compared with the control group, the expression of amyloid β(Aβ) protein and p⁃Tau protein in the model group continued to increase at all time. Conclusion The TBI model caused continuous activation of microglia along with inflammatory response, which first increased and then decreased, resultsing in neurological scores changes. In addition, the inflammatory response may act as a promoter of Aβ protein deposition and Tau protein phosphorylation, leading to cognitive impairment in mice.
7.Discrete element modeling and breakage behavior analysis of oral solid dosage form particles
Lin-xiu LUO ; Tian-bing GUAN ; An-qi LUO ; Zeng LIU ; Yu-ting WANG ; Yan-ling JIANG ; Zheng LU ; Jing-cao TANG ; Shuang-kou CHEN ; Hui-min SUN ; Chuan-yun DAI
Acta Pharmaceutica Sinica 2024;59(4):1057-1066
The breakage pattern of unit particles during the production of oral solid dosage forms (OSD) is closely related to the quality of intermediate or final products. To accurately characterize the particles and study the evolution law of particle breakage, the Bonding model of the discrete element method (DEM) was used to investigate the breakage patterns of model parameters, particle shape and process conditions (loading mode and loading rate) on the dynamic breakage, force-time curve, breakage rate, maximum breakage size ratio and fracture strength of particles. The results showed that the particle breakage force was positively correlated with normal strength and bonded disk scale, negatively correlated with normal stiffness per unit area and tangential stiffness per unit area, and weakly correlated with tangential strength. The particle breakage rate was negatively correlated with the aspect ratio of the particles, and the maximum breakage size ratio was positively correlated with the aspect ratio of the particles; among the three loading modes, the breakage rate of compression breakage model was the largest, the breakage rate of shear breakage model was the second largest, and the breakage rate of wear breakage model was the smallest; the maximum breakage size ratio was positively correlated with the loading rate, the loading mode and the loading rate had no mutual influence on particle breakage rate, but had mutual influence on the maximum breakage size ratio. The research results will provide a theoretical basis for the shift of OSD from batch manufacturing to advanced manufacturing.
8.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
9. Study on ameliorative effect of IDHP on excessive fat accumulation in hepatocytes
Jian DONG ; Yu-Chuan ZHANG ; Qiang SU ; Na SUN ; Jian DONG ; Yu-Chuan ZHANG ; Qiang SU ; Ya-Jun BAI ; Xiao-Hui ZHENG ; Na SUN ; Yan CHENG
Chinese Pharmacological Bulletin 2023;39(8):1541-1547
Aim To explore whether isopropyl3-(3, 4-dihydroxyphenyl) -2-hydroxypropanoate (IDHP) could inhibit fat accumulation in liver cells by improving mitochondrial function, and alleviate the symptom of excessive fat accumulation in patients with NAFLD. Methods Cell steatosis model was established by inducing hepatocyte fat accumulation using palmitic acid and oleic acid (PA: OA molar ratio =1
10.Diagnostic value of a combined serology-based model for minimal hepatic encephalopathy in patients with compensated cirrhosis
Shanghao LIU ; Hongmei ZU ; Yan HUANG ; Xiaoqing GUO ; Huiling XIANG ; Tong DANG ; Xiaoyan LI ; Zhaolan YAN ; Yajing LI ; Fei LIU ; Jia SUN ; Ruixin SONG ; Junqing YAN ; Qing YE ; Jing WANG ; Xianmei MENG ; Haiying WANG ; Zhenyu JIANG ; Lei HUANG ; Fanping MENG ; Guo ZHANG ; Wenjuan WANG ; Shaoqi YANG ; Shengjuan HU ; Jigang RUAN ; Chuang LEI ; Qinghai WANG ; Hongling TIAN ; Qi ZHENG ; Yiling LI ; Ningning WANG ; Huipeng CUI ; Yanmeng WANG ; Zhangshu QU ; Min YUAN ; Yijun LIU ; Ying CHEN ; Yuxiang XIA ; Yayuan LIU ; Ying LIU ; Suxuan QU ; Hong TAO ; Ruichun SHI ; Xiaoting YANG ; Dan JIN ; Dan SU ; Yongfeng YANG ; Wei YE ; Na LIU ; Rongyu TANG ; Quan ZHANG ; Qin LIU ; Gaoliang ZOU ; Ziyue LI ; Caiyan ZHAO ; Qian ZHAO ; Qingge ZHANG ; Huafang GAO ; Tao MENG ; Jie LI ; Weihua WU ; Jian WANG ; Chuanlong YANG ; Hui LYU ; Chuan LIU ; Fusheng WANG ; Junliang FU ; Xiaolong QI
Chinese Journal of Laboratory Medicine 2023;46(1):52-61
Objective:To investigate the diagnostic accuracy of serological indicators and evaluate the diagnostic value of a new established combined serological model on identifying the minimal hepatic encephalopathy (MHE) in patients with compensated cirrhosis.Methods:This prospective multicenter study enrolled 263 compensated cirrhotic patients from 23 hospitals in 15 provinces, autonomous regions and municipalities of China between October 2021 and August 2022. Clinical data and laboratory test results were collected, and the model for end-stage liver disease (MELD) score was calculated. Ammonia level was corrected to the upper limit of normal (AMM-ULN) by the baseline blood ammonia measurements/upper limit of the normal reference value. MHE was diagnosed by combined abnormal number connection test-A and abnormal digit symbol test as suggested by Guidelines on the management of hepatic encephalopathy in cirrhosis. The patients were randomly divided (7∶3) into training set ( n=185) and validation set ( n=78) based on caret package of R language. Logistic regression was used to establish a combined model of MHE diagnosis. The diagnostic performance was evaluated by the area under the curve (AUC) of receiver operating characteristic curve, Hosmer-Lemeshow test and calibration curve. The internal verification was carried out by the Bootstrap method ( n=200). AUC comparisons were achieved using the Delong test. Results:In the training set, prevalence of MHE was 37.8% (70/185). There were statistically significant differences in AMM-ULN, albumin, platelet, alkaline phosphatase, international normalized ratio, MELD score and education between non-MHE group and MHE group (all P<0.05). Multivariate Logistic regression analysis showed that AMM-ULN [odds ratio ( OR)=1.78, 95% confidence interval ( CI) 1.05-3.14, P=0.038] and MELD score ( OR=1.11, 95% CI 1.04-1.20, P=0.002) were independent risk factors for MHE, and the AUC for predicting MHE were 0.663, 0.625, respectively. Compared with the use of blood AMM-ULN and MELD score alone, the AUC of the combined model of AMM-ULN, MELD score and education exhibited better predictive performance in determining the presence of MHE was 0.755, the specificity and sensitivity was 85.2% and 55.7%, respectively. Hosmer-Lemeshow test and calibration curve showed that the model had good calibration ( P=0.733). The AUC for internal validation of the combined model for diagnosing MHE was 0.752. In the validation set, the AUC of the combined model for diagnosing MHE was 0.794, and Hosmer-Lemeshow test showed good calibration ( P=0.841). Conclusion:Use of the combined model including AMM-ULN, MELD score and education could improve the predictive efficiency of MHE among patients with compensated cirrhosis.

Result Analysis
Print
Save
E-mail