1.Effect of lag screw and support plate through axillary approach for the treatment of Ideberg typeⅡscapular pelvis fracture.
Shi-Long WU ; Yuan-Fu ZHONG ; Zhi-Min GUO
China Journal of Orthopaedics and Traumatology 2023;36(9):880-883
OBJECTIVE:
To analyze the effect of lag screw and support plate through axillary approach for the treatment of Ideberg typeⅡscapular pelvis fracture.
METHODS:
From January 2016 to June 2021, 26 patients with Ideberg typeⅡglenoid fractures were treated with trans-axillary lag screw combined with supporting plate, including 15 males and 11 females. The age ranged from 21 to 75 years, with an average of (43.12±6.56) years old. The Constant-Murley Shoulder joint Scale and University of California at Los Angeles (UCLA) score were used to evaluate the function and clinical efficacy of shoulder joint.
RESULTS:
All patients were followed up, and the duration ranged from 19 to 42 months, with an average of (30.6±10.5) months. One year after surgery, the Constant-Murley score increased from preoperative 34.9±2.5(ranged, from 28 to 47) to 87.2±6.8(ranged, from 70 to 95). The UCLA score improved from preoperative 17.9±1.7(9 to 25) to 33.1±2.3(29 to 35). Seventeen patients got an excellent result, with 7 good, and 2 fair. None of the patients had infection, screw, and plate loosening, fracture, and other complications after surgery. Two patients had different degrees of Chronic pain in the shoulder during the follow-up period.
CONCLUSION
The treatment of Ideberg typeⅡscapular glenoid fractures through axillary approach with lag screws and supporting steel plates has the advantages of convenient exposure, direct visual restoration of the normal anatomical shape of the scapular glenoid, selection of suitable positions for screw and steel plate placement, achieving better treatment results, and fewer complications. It is an effective and reliable surgical method.
Female
;
Male
;
Humans
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Scapula
;
Bone Plates
;
Bone Screws
;
Fractures, Bone
;
Steel
;
Pelvis
2.A method for sensitivity analysis of deviation factor for geometric correction of cone-beam CT system.
Hailong WANG ; Guoqin LIN ; Xiaoman DUAN ; Mengke QI ; Wangjiang WU ; Janhui MA ; Yuan XU
Journal of Southern Medical University 2023;43(7):1233-1240
OBJECTIVE:
To propose a sensitivity test method for geometric correction position deviation of cone-beam CT systems.
METHODS:
We proposed the definition of center deviation and its derivation. We analyzed the influence of the variation of the three-dimensional spatial center of the steel ball point, the projection center and the size of the steel ball point on the deviation of geometric parameters and the reconstructed image results by calculating the geometric correction parameters based on the Noo analytical method using the FDK reconstruction algorithm for image reconstruction.
RESULTS:
The radius of the steel ball point was within 3 mm. The deviation of the center of the calibration parameter was within the order of magnitude and negligible. A 10% Gaussian perturbation of a single pixel in the 3D spatial coordinates of the steel ball point produced a deviation of about 3 pixel sizes, while the same Gaussian perturbation of the 2D projection coordinates of the steel ball point produced a deviation of about 2 pixel sizes.
CONCLUSION
The geometric correction is more sensitive to the deviation generated by the three-dimensional spatial coordinates of the steel ball point with limited sensitivity to the deviation generated by the two-dimensional projection coordinates of the steel ball point. The deviation sensitivity of a small diameter steel ball point can be ignored.
Algorithms
;
Calibration
;
Cone-Beam Computed Tomography
;
Steel
3.Three-dimensional printed 316L stainless steel cardiovascular stent's electrolytic polishing and its mechanical properties.
Zhiang CHEN ; Jingtao MIAO ; Qilong WANG ; Suxia HUANG ; Jingjing CAO ; Hezong LI ; Liguo ZHAO ; Jiangyong YUAN
Journal of Biomedical Engineering 2023;40(3):552-558
The interventional therapy of vascular stent implantation is a popular treatment method for cardiovascular stenosis and blockage. However, traditional stent manufacturing methods such as laser cutting are complex and cannot easily manufacture complex structures such as bifurcated stents, while three-dimensional (3D) printing technology provides a new method for manufacturing stents with complex structure and personalized designs. In this paper, a cardiovascular stent was designed, and printed using selective laser melting technology and 316L stainless steel powder of 0-10 µm size. Electrolytic polishing was performed to improve the surface quality of the printed vascular stent, and the expansion behavior of the polished stent was assessed by balloon inflation. The results showed that the newly designed cardiovascular stent could be manufactured by 3D printing technology. Electrolytic polishing removed the attached powder and reduced the surface roughness Ra from 1.36 µm to 0.82 µm. The axial shortening rate of the polished bracket was 4.23% when the outside diameter was expanded from 2.42 mm to 3.63 mm under the pressure of the balloon, and the radial rebound rate was 2.48% after unloading. The radial force of polished stent was 8.32 N. The 3D printed vascular stent can remove the surface powder through electrolytic polishing to improve the surface quality, and show good dilatation performance and radial support performance, which provides a reference for the practical application of 3D printed vascular stent.
Humans
;
Stainless Steel
;
Powders
;
Cardiovascular System
;
Constriction, Pathologic
4.Recent Advance of Stainless Steel Used In Non-active Surgical Implantable Medical Device and Regulatory Perspective.
Guo-Hui JIAO ; Jing-Jing MIAO ; Kun WU
Chinese Journal of Medical Instrumentation 2022;46(3):312-317
Stainless steel has been widely used in non-active surgical implantable medical device of cardiovascular, orthopedics, dental and ophthalmology. In this paper, we mainly focused on development of stainless steel, as well as the material-related standard evolution. We further summarized the recent advancement of stainless steel use in surgical implantable medical device. Insight and regulatory perspective has been further demonstrated.
Prostheses and Implants
;
Stainless Steel
6.Treatment of comminuted fracture of inferior pole of patella with locking suspension and vertical fixation with three steel wires.
Hong-Ming LIN ; Bin SUN ; Heng-Jian ZHANG ; Tian-Zi LIANG ; Xu-Dong WU
China Journal of Orthopaedics and Traumatology 2022;35(1):80-84
OBJECTIVE:
To explore the clinical application of lockedge suspension combined with three steel wires vertical fixation in comminuted fracture of inferior pole of patella.
METHODS:
From August 2016 to May 2019, 23 patients with comminuted fracture of the lower pole of the patella, including 14 males and 9 females, were treated with lockedge suspension combined with three steel wires vertical fixation. The age ranged from 34 to 68 (55.0±1.2) years. One year after operation, the pain and function were evaluated by pain visual analogue scale(VAS) and knee flexion and extension range of motion, and the clinical efficacy was evaluated by Lysholm knee score standard.
RESULTS:
All 23 patients were followed up for 12 to 14, with a mean of(13.0±0.5) months. One patient had skin irritation by the tail of the steel wire, and the rest had no postoperative complications such as incision infection, internal fixation loosening and fracture displacement. The fractures of 23 patients were healed, and the healing time was 10 to 14 weeks with a mean of(12.0±1.1) weeks. The VAS score decreased from 7.96±0.93 before operation to 0.83±0.65 one year after operation. The range of knee flexion and extension activities increased from(20.30±8.69) ° before operation to 1 year after operation(127.39±6.55) °. Lysholm knee score increased from 18.48±4.00 before operation to 96.09±4.91 one year after operation(P<0.05).
CONCLUSION
The treatment of comminuted fracture of the lower pole of patella by lockedge suspension combined with three steel wires vertical fixation has reliable fixation and high fracture healing rate. It can meet the requirements of rapid rehabilitation and functional exercise, and the early clinical effect is satisfactory.
Adult
;
Aged
;
Bone Wires
;
Female
;
Fracture Fixation, Internal
;
Fractures, Bone/surgery*
;
Fractures, Comminuted/surgery*
;
Humans
;
Male
;
Middle Aged
;
Patella/surgery*
;
Steel
;
Treatment Outcome
7.Treatment of severe medial tibial bone defect in primary total knee arthroplasty with autogenous bone graft and plate fixation.
Xu-Chun WANG ; Pin-Fang JIANG ; Zhong-Qing WU ; Min-Chang CHEN ; Zhan-Feng ZHANG
China Journal of Orthopaedics and Traumatology 2022;35(11):1048-1052
OBJECTIVE:
To explore the technique of autogenous bone graft combined with plate fixation in total knee arthroplasty(TKA) with severe proximal medial tibial bone defect.
METHODS:
From March 2012 to October 2018, 21 patients (9 males and 12 females) with severe bone defects in the proximal medial tibia during primary total knee arthroplasty were treated with autogenous structural bone grafting and steel plate fixation, with an age of 61 to 77 years old with an average of (69.6±9.1) years and a course of 64 to 257 months with an average of (73.6±170.7) months. According to Rand classification, there were 13 cases of type Ⅲb and 8 cases of type Ⅳb. Postoperative complications were observed, and knee joint function was evaluated by the Hospital for Special Surgery (HSS) score and SF-36 quality of life score.
RESULTS:
All 21 patients were followed up for 37 to 64 months with an average of (49.5±13.7) months. The incisions of all patients healed smoothly, and 2 patients developed lower limb intermuscular venous plexus thrombosis after operation. There were no periprosthetic infection, loosening of prosthesis and other complications. The autogenous bone grafts of all patients achieved bony healing during postoperative X-ray follow-up, and the healing time was 8 to 13 months with an average of (10.1±2.3) months. The HSS score of patients increased significantly from 30 to 48 with an average of (53.4±4.2) before operation to 75 to 92 with an average of (81.2±8.4) at the final follow-up (P<0.05). The SF-36 quality of life score of patients after operation was significantly different from that before operation (P<0.05).
CONCLUSION
The technique of autogenous bone graft combined with steel plate fixation can achieve satisfactory osseointegration effect in the treatment of severe proximal tibial bone defects in primary knee arthroplasty, with less complications and obvious improvement in knee function.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Arthroplasty, Replacement, Knee/methods*
;
Tibia/transplantation*
;
Bone Transplantation/methods*
;
Quality of Life
;
Transplantation, Autologous
;
Steel
8.Design of a New Puncture Needle for Trocar.
Chinese Journal of Medical Instrumentation 2022;46(5):514-516
OBJECTIVE:
To develop a new type of puncture needle for indwelling needle, which can overcome the performance problems of the existing puncture needle, reduce producing cost, and enhance clinical operability.
METHODS:
In this design, solid needle thread is used to replace the traditional hollow pipe thread, three cutting edges are used to replace the existing two cutting edges, and the shaft edge form (the needle tip is on the needle thread's axis) is used to replace the original back blade or edge blade; the slot on the side of the solid core wire is used to replace the hollow and side hole on the traditional pipe. Finally, a new solid core puncture needle is formed by a section of solid core steel wire with a spiral groove, the cross-section of which is a circular slotted needle with a triangular shape at one end. Through the comparative analysis of stiffness mutation and puncture force in the experiment, the characteristics and advantages of new puncture needle are reflected.
RESULTS:
The new solid core needle can meet the need of puncture in the course of treatment, and can avoid the potential risk caused by the rigidity mutation of the needle used in the traditional indwelling needle, at the same time, it also has the space to reduce the demand of needle diameter, that means it has the potential to develop smaller needle products.
CONCLUSIONS
The new type of trocar puncture needle, from hollow to solid core, can not only meet the basic requirements of puncture and observation of blood return, but also can avoid the risk of traditional puncture needle due to stiffness mutation, the utility model also has the advantages of better performance (less puncture force) and larger expansion space.
Needles
;
Punctures
;
Steel
;
Surgical Instruments
9.Analysis on the rationality of input and output of occupational health funds in an iron and steel enterprise.
Xu ZHANG ; Hui LIU ; Shu Ling YUE ; Qun ZHANG ; Fu Hai SHEN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2022;40(8):626-631
Objective: To analyzes the various occupational health investment and occupational health output of a steel enterprise, and propose a reasonable occupational health investment plan for this enterprise. Methods: In march 2016, various occupational health input and output data of various branches of an iron and steel company in 2015 were collected, and the efficiency of occupational health inputs and outputs of each branch was evaluated using data envelopment analysis (DEA) , and the branches with non-optimal efficiency were adjusted to propose a reasonable occupational health investment plan. Results: Among the branch plants investigated by this steel company, the occupational health input-output efficiency values of ironmaking north plant, power plant, hot rolling plant and stainless steel plant were 1, while the occupational health input-output efficiency of gas making plant, cold rolling plant, metallurgical furnace charge plant, coking plant, ironmaking south plant and long product plant were not the best, and the cold rolling plant has the lowest efficiency value of 0.759. For the cold rolling plant, only the parameters of acid rolling plant satisfy α=1 and s(-)=0, s(+)=0, while the remaining four workshops do not meet. After adjusting the inputs of each part according to the parameters, the occupational health output of the remaining four workshops can reach 1.7044, 2.0238, 1.3152 and 1.2136 times of the current workshop, respectively. Adjustment plans for other branch factories with unreasonable investment structures are also presented in the corresponding tables. Conclusion: The occupational health investment structure of the ironmaking south plant and other branches in this steel enterprise is unreasonable, and the adjustment using data envelopment analysis can maximize the benefits of its occupational health output.
Financial Management
;
Iron
;
Metallurgy
;
Occupational Health
;
Steel
10.Investigation on dust pollution and pneumoconiosis incidence in a steel enterprise.
Jia Nan XU ; Lang ZHOU ; Ru Yu XUE ; Lei HAN ; Li Zhuang XIE ; Meng YE ; Heng Dong ZHANG ; Bao Li ZHU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2022;40(10):737-741
Objective: To analyze the change trend of underground dust concentration, the incidence and survival status of pneumoconiosis patients, and provide reference for improving the working environment of dust-exposed workers and the prevention and treatment of pneumoconiosis patients in the future. Methods: In February 2020, a retrospective investigation was conducted on the dust data of underground mining operations in a steel enterprise in Jiangsu Province from 1991 to 2019, and the case data of patients diagnosed with pneumoconiosis from 1956 to 2019 were collected. The time trends of the number of pneumoconiosis patients and dust concentration, the stage of pneumoconiosis and survival status of patients were analyzed. Results: From 1956 to 2019, a total of 241 patients with pneumoconiosis were diagnosed in the steel enterprise. From 1991 to 2019, the annual average dust concentration in the mine showed a downward trend as a whole. Compared with the transportation platform (14.28%, 1447/10132) , the average dust concentration exceeding rate of the mining platform (43.68%, 8415/19263) was significantly higher (χ(2)=2674.84, P<0.01) . The average age of pneumoconiosis patients was (73.54±10.42) years old, and the average working age of dust exposure was (21.41±8.68) years, of which 85 cases (35.27%) survived and 156 cases (64.73%) died. The main type of pneumoconiosis was silicosis (90.46%, 218/241) , and the main stage of pneumoconiosis was the stage I (96.68%, 233/241) ; The higher the stage of pneumoconiosis, the younger the diagnosis age (P<0.01) . The average survival time of patients was (27.264±1.982) years, and the median survival time was 28 years. The cumulative survival rates of patients with pneumoconiosis in different diagnosis time periods were significantly different (χ(2)=35.57, P<0.01) . Conclusion: The improved dust-proof measures have a significant effect on reducing the concentration of underground dust. We need to focus on the dust control of underground mining platforms and the treatment of patients with stage Ⅲ pneumoconiosis.
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Child
;
Adolescent
;
Young Adult
;
Adult
;
Incidence
;
Coal Mining
;
Steel
;
Retrospective Studies
;
Pneumoconiosis/diagnosis*
;
Dust
;
Occupational Exposure/adverse effects*

Result Analysis
Print
Save
E-mail