1.Single-copy Loss of Rho Guanine Nucleotide Exchange Factor 10 ( arhgef10) Causes Locomotor Abnormalities in Zebrafish Larvae.
Yi ZHANG ; Ming Xing AN ; Chen GONG ; Yang Yang LI ; Yu Tong WANG ; Meng LIN ; Rong LI ; Chan TIAN
Biomedical and Environmental Sciences 2022;35(1):35-44
OBJECTIVE:
To determine if ARHGEF10 has a haploinsufficient effect and provide evidence to evaluate the severity, if any, during prenatal consultation.
METHODS:
Zebrafish was used as a model for generating mutant. The pattern of arhgef10 expression in the early stages of zebrafish development was observed using whole-mount in situ hybridization (WISH). CRISPR/Cas9 was applied to generate a zebrafish model with a single-copy or homozygous arhgef10 deletion. Activity and light/dark tests were performed in arhgef10 -/-, arhgef10 +/-, and wild-type zebrafish larvae. ARHGEF10 was knocked down using small interferon RNA (siRNA) in the SH-SY5Y cell line, and cell proliferation and apoptosis were determined using the CCK-8 assay and Annexin V/PI staining, respectively.
RESULTS:
WISH showed that during zebrafish embryonic development arhgef10 was expressed in the midbrain and hindbrain at 36-72 h post-fertilization (hpf) and in the hemopoietic system at 36-48 hpf. The zebrafish larvae with single-copy and homozygous arhgef10 deletions had lower exercise capacity and poorer responses to environmental changes compared to wild-type zebrafish larvae. Moreover, arhgef10 -/- zebrafish had more severe symptoms than arhgef10 +/- zebrafish. Knockdown of ARHGEF10 in human neuroblastoma cells led to decreased cell proliferation and increased cell apoptosis.
CONCLUSION
Based on our findings, ARHGEF10 appeared to have a haploinsufficiency effect.
Animals
;
Annexin A5
;
Apoptosis
;
Blotting, Western
;
CRISPR-Associated Protein 9
;
CRISPR-Cas Systems
;
Cell Line
;
Cell Proliferation
;
Cells, Cultured
;
Flow Cytometry
;
Genotype
;
Humans
;
In Situ Hybridization
;
Larva/physiology*
;
Phenotype
;
RNA/isolation & purification*
;
Real-Time Polymerase Chain Reaction/standards*
;
Rho Guanine Nucleotide Exchange Factors/metabolism*
;
Sincalide/analysis*
;
Spectrophotometry/methods*
;
Zebrafish/physiology*
2.Graphite furnace atomic absorption spectrometry for the determination of trace gallium in whole blood.
Chinese Journal of Industrial Hygiene and Occupational Diseases 2022;40(10):776-778
Objective: To establish a graphite furnace atomic absorption spectrometry method for the determination of trace gallium in whole blood. Methods: From January to May 2021, the five factors of ashing temperature, ashing time, atomization temperature, atomization time and matrix modifier concentration in the determination of gallium in whole blood by graphite furnace atomic absorption spectrometry were optimized by using L(16) (4(5)) orthogonal test design. At the same time, within-run, between-run, spiking recovery test and other methodological indicators were tested. Results: Under the optimized detection conditions, the linear range of determination of gallium in whole blood by graphite furnace atomic absorption spectrometry was 0.29-100.00 μg/L (r=0.9991) . The within-run and between-run relative standard deviations (RSD) of repetitive measurement at 10.0, 50.0, 80.0 μg/L concentration levels were 2.3%-4.4% and 1.5%-3.6%, the recovery rate of spiking was 98.1%-103.8%, and the detection limit of the method was 0.13 μg/L. Conclusion: Graphite furnace atomic absorption spectrometry for the determination of trace gallium in whole blood is easy to operate, has a wide linear range, low detection limit, accurate and reliable results, which is suitable for occupational health examinations and the determination of acute gallium poisoning.
Spectrophotometry, Atomic/methods*
;
Graphite/chemistry*
;
Gallium
;
Limit of Detection
;
Temperature
3.Applying risk management to analytical methods for the desorbing process of ginkgo diterpene lactone meglumine injection.
Fang-Fang XU ; Yu-An BI ; Wen-Zhe HUANG ; Zhen-Zhong WANG ; Wei XIAO
Chinese Journal of Natural Medicines (English Ed.) 2018;16(5):366-374
Analysis errors can occur in the desorbing process of ginkgo diterpene lactone meglumine injection (GDMI) by a conventional analysis method, due to several factors, such as easily crystallized samples, solvent volatility, time-consuming sample pre-processing, fixed method, and offline analysis. Based on risk management, near-infrared (NIR) and mid-infrared (MIR) spectroscopy techniques were introduced to solve the above problems with the advantage of timely analysis and non-destructive nature towards samples. The objective of the present study was to identify the feasibility of using NIR or MIR spectroscopy techniques to increase the analysis accuracy of samples from the desorbing process of GDMI. Quantitative models of NIR and MIR were established based on partial least square method and the performances were calculated. Compared to NIR model, MIR model showed greater accuracy and applicability for the analysis of the GDMI desorbing solutions. The relative errors of the concentrations of Ginkgolide A (GA) and Ginkgolide B (GB) were 2.40% and 2.89%, respectively, which were less than 5.00%. The research demonstrated the potential of the MIR spectroscopy technique for the rapid and non-destructive quantitative analysis of the concentrations of GA and GB.
Chemistry, Pharmaceutical
;
methods
;
standards
;
Drug Compounding
;
standards
;
Drugs, Chinese Herbal
;
analysis
;
chemistry
;
standards
;
Ginkgolides
;
analysis
;
chemistry
;
standards
;
Injections
;
Lactones
;
analysis
;
Least-Squares Analysis
;
Meglumine
;
analysis
;
chemistry
;
standards
;
Reproducibility of Results
;
Risk Management
;
Spectrophotometry, Infrared
;
standards
4.Spectrophotometric determination of ammonia levels in tobacco fillers of and sidestream smoke from different cigarette brands in Japan.
Yohei INABA ; Shigehisa UCHIYAMA ; Naoki KUNUGITA
Environmental Health and Preventive Medicine 2018;23(1):15-15
BACKGROUND:
The ammonia contained in tobacco fillers and mainstream and sidestream cigarette smoke accelerates nicotine dependence in cigarette smokers. Ammonia has been included in the non-exhaustive priority list of 39 tobacco components and emissions of cigarette published by the World Health Organization (WHO) Study Group on Tobacco Product Regulation. The development of a simple ammonia detection method will contribute to the establishment of tobacco product regulation under tobacco control policies and allow surveys to be conducted, even by laboratories with small research budgets.
METHODS:
We developed a simple colorimetric method based on the salicylate-chlorine reaction and absorption spectrometry with two reagents (sodium nitroprusside and sodium dichloroisocyanurate). To compare this method to conventional ion chromatography, we analyzed the ammonia levels in tobacco fillers extracted from 35 Japanese commercially marketed cigarette brands manufactured by four tobacco companies (Japan Tobacco (JT) Inc., British American Tobacco (BAT), Philip Morris Japan, and Natural American Spirit). We also analyzed the ammonia levels in the sidestream smoke from cigarettes of the brands that were found to contain high or low tobacco filler ammonia levels.
RESULTS:
The ammonia levels in the reference cigarette (3R4F) measured by our method and ion chromatography were similar and comparable to previously reported levels. The ammonia levels in tobacco fillers extracted from 35 cigarette brands ranged from 0.25 to 1.58 mg/g. The mean ammonia level of JT cigarette brands was significantly higher (0.83 ± 0.28 mg/g) than that of Natural American Spirit cigarette brands (0.30 ± 0.08 mg/g) and lower than those in the other two cigarette brands (1.11 ± 0.19 mg/g for BAT and 1.24 ± 0.15 mg/g for Philip Morris) (p < 0.001 by Bonferroni test). The ammonia levels in the sidestream smoke of CABIN, Marlboro Black Menthol, American Spirit Light, and Seven Stars were 5.89 ± 0.28, 5.23 ± 0.12, 6.92 ± 0.56, and 4.14 ± 0.19 mg/cigarette, respectively. The ammonia levels were higher in sidestream smoke than in tobacco filler.
CONCLUSIONS
Our simple colorimetric could be used to analyze ammonia in tobacco fillers and sidestream smoke. There were significant differences between the ammonia levels of the 35 commercially marketed cigarette brands in Japan manufactured by four tobacco manufacturers. Over 90% of the ammonia in sidestream smoke was in gaseous phase.
Ammonia
;
analysis
;
Colorimetry
;
methods
;
Japan
;
Smoke
;
analysis
;
Spectrophotometry
;
methods
;
Tobacco
;
chemistry
;
Tobacco Products
;
analysis
5.Lead, Mercury, and Cadmium Exposure in the Korean General Population
Sang Yong EOM ; Young Sub LEE ; Seul Gi LEE ; Mi Na SEO ; Byung Sun CHOI ; Yong Dae KIM ; Ji Ae LIM ; Myung Sil HWANG ; Ho Jang KWON ; Yu Mi KIM ; Young Seoub HONG ; Seok Joon SOHN ; Kyung Su PARK ; Hee Soo PYO ; Ho KIM ; Heon KIM ; Jung Duck PARK
Journal of Korean Medical Science 2018;33(2):e9-
BACKGROUND: Lead (Pb), mercury (Hg), and cadmium (Cd) are well-known environmental pollutants. They are unnecessary in the biological processes of humans. This study was performed to estimate the representative background exposure levels to the metals by measuring concentrations in whole blood of the Korean general population. METHODS: This population-based cross-sectional study included 4,000 subjects (1,886 males and 2,114 females) 0–83 years of age in 2010 and 2011. Adult subjects (≥ 19 years of age) were collected by sex- and age-stratified probability method, and preschool- and school-aged subjects were recruited by a cluster sampling method. Written consent was provided prior to blood sampling. Pb and Cd blood concentrations were determined by a flameless atomic absorption spectrophotometry, and blood Hg was analyzed by a direct Hg analyzer. RESULTS: The geometric mean, median and 95th percentile of blood Pb was 1.82 µg/dL, 1.83 µg/dL, and 3.78 µg/dL, respectively. The respective values were 2.92 µg/L, 2.87 µg/L, 9.12 µg/L for Hg, and 0.56 µg/L, 0.59 µg/L, 2.20 µg/L for Cd. Blood Pb and Hg were higher in males than in females, but no sex difference was observed, respectively, in subjects 0–4 years of age for Pb and in subjects less than 20 years for Hg. However, blood Cd was higher in females than in males and no sex difference was observed in subjects < 30 years of age. CONCLUSION: This study provides representative data of human exposure to Pb, Hg, and Cd covering whole age groups of the general population in Korea.
Adult
;
Biological Processes
;
Cadmium
;
Cross-Sectional Studies
;
Environmental Pollutants
;
Female
;
Humans
;
Korea
;
Male
;
Metals
;
Methods
;
Sex Characteristics
;
Spectrophotometry, Atomic
6.Comparison of the optical properties of pre-colored dental monolithic zirconia ceramics sintered in a conventional furnace versus a microwave oven.
The Journal of Advanced Prosthodontics 2017;9(5):394-401
PURPOSE: The purpose of this study was to compare the optical properties of pre-colored dental monolithic zirconia ceramics of various thicknesses sintered in a microwave and those in a conventional furnace. MATERIALS AND METHODS: A2-shade of pre-colored monolithic zirconia ceramic specimens (22.0 mm × 22.0 mm) in 3 thickness groups of 0.5, 1.0, and 1.5 mm were divided into 2 subgroups according to the sintering methods (n=9): microwave and conventional sintering. A spectrophotometer was used to obtain CIELab color coordinates, and translucency parameters and CIEDE2000 color differences (ΔE 00) were measured. The relative amount of monoclinic phase (X(m)) was estimated with x-ray diffraction. The surface topography was analyzed by atomic force microscope and scanning electron microscope. Statistical analyses were conducted with two-way ANOVA (α=.05). RESULTS: There were small interaction effects on CIE L*, a*, and TP between sintering method and thickness (P<.001): L* (partial eta squared η(p)²=0.115), a* (η(p)²=0.136), and TP (η(p)²=0.206), although higher b* values were noted for microwave sintering regardless of thickness. Color differences between two sintering methods ranged from 0.52 to 0.96 ΔE(00) units. The X(m) values ranged from 7.03% to 9.89% for conventional sintering, and from 7.31% to 9.17% for microwave sintering. The microwave-sintered specimen demonstrated a smoother surface and a more uniform grain structure compared to the conventionally-sintered specimen. CONCLUSION: With reduced processing time, microwave-sintered pre-colored dental monolithic zirconia ceramics can exhibit similar color perception and translucency to those by conventional sintering.
Ceramics*
;
Clothing
;
Color Perception
;
Methods
;
Microwaves*
;
Spectrophotometry
;
X-Ray Diffraction
7.Performance Evaluation of Automated Clinical Chemistry Analyzer for Indocyanine Green (ICG) R15 Test.
Ju Heon PARK ; Eun Jeong WON ; Hyun Jung CHOI ; Seung Jung KEE ; Soon Pal SUH
Laboratory Medicine Online 2016;6(3):140-146
BACKGROUND: The conventional indocyanine green retention rate at 15 minutes (ICG R15) test is inefficient and inconvenient because it requires the use of a manual spectrophotometer and several samples per patient. This study aimed to establish the automation of the ICG R15 test using an automated clinical chemistry analyzer, and to evaluate the calculation of R15 with a small number of samples. METHODS: The performance of the AU5832 (Beckman Coulter, USA) for determining ICG concentration was evaluated in accordance with the Clinical Laboratory Standards Institute (CLSI) guidelines. The R15 results for 77 patients determined by spectrophotometry and AU5832 were compared. We evaluated the calculation of R15 with three samples, except for one sample in which the results had been obtained previously, at 5, 10, and 15 minutes after injection of ICG into the patients, and compared the results with those obtained with four samples. RESULTS: The automated ICG test using the AU5832 system showed proper performances according to CLSI. Although the difference in the R15 results between the two methods was within the 95% confidence interval, the R15 was adjusted by the regression equation because it was slightly lower according to the automated method compared with the manual method. The R15 with three samples (0, 5, and 15 minutes) showed the best correlation with conventional R15 with four samples (r2=0.996). Compared with the manual method, the R15 result using the AU5832 showed excellent agreement with four samples (kappa value 0.904) and with three samples (kappa value 0.880). CONCLUSIONS: The ICG R15 test using the AU5832 system is comparable with the conventional method in clinical use.
Automation
;
Chemistry, Clinical*
;
Humans
;
Indocyanine Green*
;
Methods
;
Spectrophotometry
8.Determination of residual aluminium Ion in Huoxiang Zhengqi pellets by GFAAS with EDTA complexation extraction.
Xue-Na WANG ; Cong-Cong RAN ; Qing-Lian LI ; Chao-Hui DU ; Ye JIANG
China Journal of Chinese Materia Medica 2015;40(12):2345-2348
To establish an EDTA complexation extraction pretreatment combining with GFAAS method for the determination of residual aluminium ion in Huoxiang zhengqi pellets without digestive treatment, systematical investigation was made on sample preparation, and EDTA was used for the complexation extraction of residual aluminium ion in samples. The pH, concentration and volume of extraction solution, the temperature and time of microwave extraction, and graphite furnace temperature program were investigated. The results were compared with the microwave digestion. It was showed that, 0.1 g of sample weight was added in 20 mL 0.05 mol x L(-1) EDTA solution (pH 3.5), followed by heating at 150 degrees C for 10 min in the microwave extraction device. The determination of GFAAS was performed at optimized detection wavelength (257.4 nm) as well as graphite furnace temperature program, the detection limits and quantification limits were 2.37 μg x L(-1) and 7.89 μg x L(-1), respectively. The precision (RSD) was less than 2.3%. The average recovery was 96.9% -101%. The present method is easy, rapid and accurate for the determination of residual aluminium ion in Huoxiang zhengqi pellets.
Aluminum
;
chemistry
;
isolation & purification
;
Drug Contamination
;
Drugs, Chinese Herbal
;
chemistry
;
Edetic Acid
;
chemistry
;
Graphite
;
chemistry
;
Spectrophotometry, Atomic
;
methods
;
Temperature
9.Determination of indium in whole blood by graphite furnace atomic absorption spectrometry.
Juntao HE ; Fen LIU ; Yingping XIANG ; Zhimin LI ; E-mail: LIZHIMIN567@SINA.COM.
Chinese Journal of Industrial Hygiene and Occupational Diseases 2015;33(8):627-629
OBJECTIVETo investigate the sensitization effect of different chemical modifiers in the determination of indium in whole blood by graphite furnace atomic absorption spectrometry, and to develop a new method for the determination of indium in whole blood.
METHODSA mixture of 0.3% HNO3 (V/V) + 0.1% Triton X-100 (V/V) was used as a diluent, and a solution of 1 000 µg/ml Pd (NO3)2 + 3 000 µg/ml Mg (NO3)2 was used as modifier. After being diluted five times, the concentration of indium of the blood was directly determined by graphite furnace atomic absorption spectrometry.
RESULTSThe detection limit of the method was 0.33 µg/L, the linear range was 0.33~100.00 µg/L, the relative standard deviation was 1.43%~2.65%, and the recovery rate was 98.3%~105.3%.
CONCLUSIONThe method is simple and fast and has high recovery and precision, and it is suitable for the determination of indium in whole blood.
Blood Chemical Analysis ; instrumentation ; Graphite ; Humans ; Indium ; blood ; Limit of Detection ; Spectrophotometry, Atomic ; methods
10.Spectrophotometric determination of silicon tetrahydride in the air of workplace.
Na-li GU ; Ting-ming SHI ; Zhi-hong ZHANG ; Sheng-wen SHAO ; Tao JING ; Wei-hong CHEN
Journal of Huazhong University of Science and Technology (Medical Sciences) 2015;35(2):188-191
A new, simple and sensitive method was developed for the determination of silicon tetrahydride in the air of workplace in this study. The alkaline resin-based spherical activated carbon was used to collect sample of silicon tetrahydride at workplace. Silicon tetrahydride was then desorbed from active carbon in 100°C hot water. After reacting with ammonium molybdate, oxalic acid and 1,2,4-trichlorobenzene alpha-naphthol amino sulfonic acid under acid condition, silicon tetrahydride was transformed into silicon molybdenum blue. The absorbance of silicon molybdenum blue was quantitatively measured at the wavelength of 680 nm. The results showed that the average sampling efficiency and desorption efficiency were 97.53% and 94.94%, respectively by this method. Detection limits were 0.054 μg/mL for the spectrophotometric method and 0.14 mg/m(3) for the determination of silicon tetrahydride in the air of workplace (sampling volume was 7.5 L). The conversion rate of silicon tetrahydride gradually decreased when storage time of samples was extended. The descent rate of sample was less than 10% when the sample was sealed for 7 days in the room temperature. It was concluded that this spectrophotometric method can be successfully used to determine silicon tetrahydride in the worksites.
Air Pollutants, Occupational
;
analysis
;
Humans
;
Limit of Detection
;
Reproducibility of Results
;
Silanes
;
analysis
;
Spectrophotometry
;
methods
;
Workplace

Result Analysis
Print
Save
E-mail