1.Mechanism of acupoint penetration acupuncture therapy regulating chondrocyte autophagy via the PI3K/Akt-mTOR pathway in KOA rats
Yang Gao ; Qingbo Wang ; Songwei Li ; Xiaojing Shi ; Shan Dai ; Jingjing Yu ; Qingpan Zhao ; Yang Wang ; Youlong Zhou
Journal of Traditional Chinese Medical Sciences 2024;11(3):363-375
Objective:
To investigate whether acupoint penetration acupuncture (APA) could regulate chondrocyte autophagy and apoptosis via the PI3K/Akt-mTOR signaling pathway to reduce cartilage degeneration in knee osteoarthritis (KOA) rats.
Methods:
KOA was induced in rats via intra-articular injection of sodium iodoacetate resolution. Forty male Sprague-Dawley rats were randomly assigned to blank control, model, APA, electro-acupuncture (EA), and sham model groups (n = 8) and those in the APA and EA groups received their respective therapies. Following completion of the treatment course, histological examinations of cartilage and muscle were conducted. Levels of apoptosis- and autophagy-related factors, including Bax, Bcl-2, mTOR, ULK-1, and Beclin-1 protein, and mRNAs were assessed. Additionally, β-endorphin (β-EP) concentrations in the brain and serum were measured.
Results:
Histological analysis revealed that APA alleviated cartilage and muscle damage compared with the model group. APA inhibited cartilage degeneration by modulating the expression of apoptosis- and autophagy-related proteins and mRNA, thus preventing chondrocyte apoptosis. In the APA group, Bax and mTOR protein levels were significantly lower than those in the model group (both P = .024). Conversely, the Bcl-2 expression level was significantly higher than that in the EA group (P = .035). Additionally, ULK-1 expression was significantly lower than that in the EA group (P = .045). The mRNA level of Bax was significantly higher than that in the blank control group (P < .001). However, Beclin-1 levels were significantly higher than those in both the model and EA groups (both P < .001). ELISA results showed a significant decrease in the concentration of β-EP in the brains of the rats in the APA group compared with those in the model group (P = .032).
Conclusions
APA reduced osteoarthritis-related pain and alleviated cartilage damage by upregulating chondrocyte autophagy and down-regulating apoptosis via signaling pathways involving PI3K/Akt-mTOR in KOA rats.
2.Feasibility of low-dose CT brain perfusion scanning based on deep learning reconstruction algorithm: a preliminary study
Limin LEI ; Yuhan ZHOU ; Xiaoxu GUO ; Hui WANG ; Jinping MA ; Zhihao WANG ; Weimeng CAO ; Yuan GAO ; Yuming XU ; Songwei YUE
Chinese Journal of Radiological Medicine and Protection 2024;44(7):613-621
Objective:To compare image quality and diagnostic parameters of whole-brain CT perfusion scans under different scanning conditions and assess the utility of deep learning image reconstruction algorithm (DLIR) in reducing tube current during low-dose scans.Methods:Method A total of 105 patients with suspected acute ischemic stroke (AIS) were prospectively enrolled in the First Affiliated Hospital of Zhengzhou University from March, 2022 to March, 203 and their baseline information was recorded. All patients underwent head non-contrast CT and CT perfusion (CTP) examinations. CTP scanning was performed at 80 kV in two groups with the tube current of 150 mA (regular dose) and 100 mA (low dose), respectively. The CTP images of 150 mA group were reconstructed using filtered back-projection algorithm as well as adaptive statistical iterative reconstruction-V (ASIR-V) at 40% and 80% strength levels, which were denoted as groups A-C. The CTP images of 100 mA group were reconstructed using ASIR-V80%, DLIR-M, and DLIR-H, which were denoted as groups D-F. Clinical baseline characteristics and radiation doses were compared between the two groups under different scanning conditions. Furthermore, we assessed the subjective and objective image quality, conventional perfusion parameters, and abnormal perfusion parameters of AIS patients across the six groups of reconstructed CTP images.Results:Under the scanning conditions of 150 mA and 100 mA, 47 and 48 patients were diagnosed with AIS, respectively. There were no significant differences in the baseline characteristics between the two groups. However, there was a significant difference in the mean effective radiation dose (5.71 mSv vs. 3.80 mSv, t = 2 768.30, P < 0.001). The standard deviation (SD) of noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of gray matter (GM) and white matter (WM) were significantly different among the six groups of reconstructed images ( F = 40.58-212.13, P < 0.001). In GM, the SD values in groups C, D, and F were lower than those in other groups ( P < 0.05), and the SNR values in groups C and F were higher than those in other groups ( P < 0.05). In WM, the SD and SNR values in groups C and F were significantly different from those in other groups ( P < 0.05). Additionally, CNR values in groups C and F were higher than those in other groups ( P < 0.05). There was no significant difference in subjective scores among groups B, C, and F ( P > 0.05). Regarding perfusion parameters in the brain GM, groups D and E had lower cerebral blood volume (CBV) values compared to groups A to C ( P < 0.05), and group F had lower CBV values than group B ( P < 0.05). In the brain WM, group D had consistently lower mean transit time (MTT) values compared to the other groups ( P < 0.05). Notably, there were no significant differences in AIS lesion detection rates and relevant diagnostic parameters across the six image groups. Conclusions:Low-tube current CTP scan combined with the DLIR-H algorithm can enhance image quality without affecting perfusion parameters such as CBV and MTT, while reducing radiation dose by 30%. This algorithm can be routinely applied in brain CTP examinations.
3.A review on intelligent auxiliary diagnosis methods based on electrocardiograms for myocardial infarction.
Chuang HAN ; Wenge QUE ; Zhizhong WANG ; Songwei WANG ; Yanting LI ; Li SHI
Journal of Biomedical Engineering 2023;40(5):1019-1026
Myocardial infarction (MI) has the characteristics of high mortality rate, strong suddenness and invisibility. There are problems such as the delayed diagnosis, misdiagnosis and missed diagnosis in clinical practice. Electrocardiogram (ECG) examination is the simplest and fastest way to diagnose MI. The research on MI intelligent auxiliary diagnosis based on ECG is of great significance. On the basis of the pathophysiological mechanism of MI and characteristic changes in ECG, feature point extraction and morphology recognition of ECG, along with intelligent auxiliary diagnosis method of MI based on machine learning and deep learning are all summarized. The models, datasets, the number of ECG, the number of leads, input modes, evaluation methods and effects of different methods are compared. Finally, future research directions and development trends are pointed out, including data enhancement of MI, feature points and dynamic features extraction of ECG, the generalization and clinical interpretability of models, which are expected to provide references for researchers in related fields of MI intelligent auxiliary diagnosis.
Humans
;
Electrocardiography
;
Myocardial Infarction/diagnosis*
;
Recognition, Psychology
4.Predicting the invasiveness of lung adenocarcinoma manifesting as ground-glass opacity using spectral CT multi-parameter functional imaging
Xiaoxu GUO ; Limin LEI ; Shushan DONG ; Hui WANG ; Jinping MA ; Weijie WU ; Songwei YUE
Chinese Journal of Radiology 2023;57(8):870-877
Objective:To explore the clinical value of quantitative parameters on spectral CT in predicting the invasiveness of lung adenocarcinoma manifesting as ground-glass nodules (GGN).Methods:The clinical and imaging data of 129 patients with pathologically confirmed lung adenocarcinoma who were surgically resected in the First Affiliated Hospital of Zhengzhou University from March to October 2022 were retrospectively analyzed, including 45 males and 84 females, aged from 33 to 81. According to the pathological results, they were divided into the minimally invasive adenocarcinoma (MIA) group ( n=64) and the invasive adenocarcinoma (IAC) group ( n=65). All patients underwent enhanced spectral CT within two weeks before surgery. The iodine density map, Z-Effective (Z eff) map, and electron density (ED) map were reconstructed on the post-processing workstation, and the spectral parameters, including normalized iodine concentration (NIC), arterial enhancement fraction (AEF), Z eff, and ED were measured and calculated. Conventional CT features were analyzed, including maximum diameter, CT value, nodule types, margin, lobulation sign, spiculation sign, bubble sign, pleural retraction sign, abnormal vascular sign, and air bronchial sign. The clinical features, conventional CT characteristics and spectral CT parameters of two groups were compared using the independent sample t test, the Mann-Whitney U test, and the χ 2 test. Multivariate logistic regression analysis was used to evaluate the independent risk factors of lung adenocarcinoma invasiveness, and the model was constructed. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the performance of parameters and models in predicting the invasiveness of lung adenocarcinoma. Results:There were significant differences between the MIA group and IAC group in maximum diameter, CT value, nodule type, margin, spiculation sign, pleural retraction sign, air bronchial sign, venous phase NIC, AEF, venous phase Z eff, arterial phase ED, venous phase ED ( P<0.05). Multivariate logistic regression analysis showed that the maximum diameter (OR=1.183, 95%CI 1.062-1.318), CT value (OR=1.004, 95%CI 1.001-1.007), venous phase NIC (OR=1.185, 95%CI 1.083-1.298), AEF(OR=0.975, 95%CI 0.957-0.994), venous phase Z eff (OR=0.031, 95%CI 0.005-0.196) were independent influence factors for the invasiveness of lung adenocarcinoma. The conventional CT model was established with the maximum diameter and CT value, and the spectral CT model was established with venous phase NIC, AEF, and venous phase Z eff. The combined model was established with all the parameters above. Areas under the ROC curve of the conventional CT model, the spectral CT model, and the combined model for predicting the invasiveness of lung adenocarcinoma were 0.828, 0.854, and 0.902, respectively. Conclusion:The quantitative parameters of double-layer detector spectral CT can be used as an indicator to predict the invasiveness of lung adenocarcinoma manifesting as GGN, and AEF has the highest diagnostic efficacy. Spectral CT combined with conventional CT features can further improve the diagnostic efficiency.
5.Revision of the Chinese version of Nurse Informatics Competency Assessment Scale
Xin CHEN ; Yufang GAO ; Wenyuan WANG ; Yu WU ; Songwei SUN
Chinese Journal of Modern Nursing 2021;27(9):1176-1180
Objective:To translate the Canadian Nurse Informatics Competency Assessment Scale into Chinese, revise it and test its reliability and validity.Methods:Translation and back translation were conducted strictly following the Brislin translation model, and 7 experts were organized to adjust the scale. From August to December 2019, convenience sampling was used to select 923 nurses in a ClassⅢ Grade A hospital in Qingdao for investigation with the Chinese version of the adjusted Nurse Informatics Competency Assessment Scale so as to test its reliability and validity.Results:The content validity index of the final Nurse Informatics Competency Assessment Scale was 0.960. Exploratory factor analysis extracted four common factors, and the cumulative variance contribution rate was 70.455%. The confirmatory factor analysis result showed that χ 2/ df was 2.862, and root mean square error approximation was 0.047, and goodness of fit index was 0.893, and comparative fit index was 0.947, and incremental fit index was 0.948, and normative fit index was 0.922, and relative fit index was 0.906, and Tucker-Lewis index was 0.937. The total Cronbach's α coefficient of the scale was 0.950, and the half-fold reliability was 0.863, and the test-retest reliability was 0.827. Conclusions:The Nurse Informatics Competency Assessment Scale has good reliability and validity, and can be used as an evaluation tool for clinical nurses' nursing information competency.
6.Experience of the support of medicine in Harmonious Mission -2018
Xiaoguang LI ; Panpan ZHANG ; Jinghong XU ; Yunxia WANG ; Songwei LU ; Min LIU ; Shen GAO
Journal of Pharmaceutical Practice 2020;38(1):1-4
Objective Through the statistics of drug consumption in the task of Harmonious Mission -2018, sort out the process of medication supply of overseas medical services, analyze and evaluate the medication supply services. Methods Count the types and quantities of medicines consumed by marine hospitals in the Harmonious Mission-2018, analyze whether the preparation of medicines is sufficient, effective, and economically reasonable, and find way to improve the process of medicine supply in overseas medical services. Results Statistics on the consumption of drugs in the Harmonious Mission-2018 show that the number of drugs consumed accounted for 68.21% of the total kinds of medicine carried, that the total amount of drugs consumed accounted for 40.61% of the total costs of medicine carried, and that the total number of boxes of drugs consumed (the number of the smallest packages) accounted for 21.72% of the total number of boxes of medicine carried. Conclusion The medicine support services in the Harmonious Mission-2018 was sufficient and effective. But, the workflow and the processes of the services still need to be further improved.
7. Effect and satisfaction evaluation of post-abortion care service based on Wechat follow-up on contraceptive compliance of repetitive induced abortion patients
Tao SUN ; Songwei WANG ; Changdong LI
Chinese Journal of Practical Nursing 2020;36(6):429-434
Objective:
To explore the effect of
8.Clinical significance of expression of serum cystatin C in patients with acute leukemia
Jingyong ZHOU ; Juan WANG ; Hua TANG ; Songwei ZHOU ; Zefa LIU
Journal of Leukemia & Lymphoma 2018;27(9):521-524
Objective To study the clinical significance of serum cystatin C (Cys C) in patients with acute leukemia (AL). Methods A total of 59 newly diagnosed AL patients in Xinghua City People's Hospital from January 2014 to August 2017 were enrolled; meanwhile, 59 healthy individuals who underwent physical examination at Medical Center of Xinghua City People's Hospital were selected as the control group. AU5800 automatic biochemical analyzer from American Beckman Coulter Corporation was applied to detect the levels of serum Cys C, lactate dehydrogenase (LDH) and creatinine (Cr). The receiver operating characteristic (ROC) curve was also drawn. Results The levels of serum Cys C and LDH in AL patients were higher than those in the control group [serum Cys C: (1.36±0.72) mg/L vs. (0.76±0.27) mg/L; LDH: (456±362) U/L vs. (185±29) U/L], and there was a statistical significance (t=-5.965, P=0.000; t=-5.718, P=0.000). There was no statistical difference in the serum Cr between AL patients and control group [(86±26) μmol/L vs. (82±16) μmol/L] (P> 0.05). There was a positive correlation between levels of serum Cys C and LDH in AL patients (rs= 0.447, P < 0.05). The ROC area under curve of serum Cys C was 0.823, the standard error was 0.037, and the confidence interval of 95 % was 0.751-0.896. The ROC area under curve of serum LDH was 0.811, the standard error was 0.042, and the confidence interval of 95 % was 0.728-0.894. Conclusion The level of serum Cys C in AL patients is higher than that in the healthy population. The detection of serum Cys C is helpful in the diagnosis of AL and the evaluation of tumor burden, which is consistent with serum LDH.
9. The efficacy of knee-chest position on exhaust and defecation of gynecologic diseases patients after laparoscopy
Songwei WANG ; Xinzhang SUN ; Tao SUN ; Changdong LI
Chinese Journal of Practical Nursing 2018;34(19):1478-1481
Objective:
To investigate the effect of knee-chest position on exhaust and defecation of gynecologic diseases patients after laparoscopic surgery.
Methods:
This quasi-experiment trail was conducted between July 2016 to May 2017, in a birth control ward at an obstetrics and gynecology hospital in Beijing, China. The study included a total of 258 patients who had gynecological benign diseases and received gynecological laparoscopic surgery. Participants were recruited in the trail by using a convenient sampling method with 130 patients who received gynecological laparoscopic surgery from July 2016 to December 2016 in the experimental group (on the basis of routine care, patients preformed a knee-chest position intervention after 6 hours of the surgery) and 128 patients who received gynecologic laparoscopic surgery between January 2017 and May 2017 in the control group (patients received a routine care). The primary end point was the postoperative anal exhaust.
Results:
The ambulation rate before post-operative ventilation of the experimental group was 21.5% (28/130) less than that of the control group (91.4%, 117/128). The difference was statistically significant (
10.Dual stent technology used for TIPS: recent progress in research
Qiang HAN ; Yingchun LI ; Songwei LI ; Minhuang SUN ; Lei WANG
Journal of Interventional Radiology 2017;26(9):859-861
Nowadays,transjugular intrahepatic portosystemic shunt (TIPS) has already become the main means for the treatment of portal hypertension and its complications due to cirrhosis.The Viatorr stent that is specifically designed for TIPS has been available in China since the end of 2015,but it has not been widely used in clinical practice in China so far.At present,superimposed release dual-stent technology by using one bare stent and one covered stent,as simulation of Viatorr stent,to perform TIPS is still employed in many clinical centers in China.Dual stent technology carries unique advantages,although the long-term efficacy of dual-stent implantation technology is not as good as that of single-stent implantation technology.This paper aims to make a comprehensive review about the dual-stent technology used for TIPS,focusing on the dual-stent technique classification and advantages,the causes and the managements of postoperative shunt dysfunction,etc.so as to let this technique can be mnore effectively used in treating portal hypertension caused by cirrhosis.