1.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
2.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
3.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
4.The need for developing guidelines for radiation protection in dental institutions
Journal of Korean Academy of Oral Health 2019;43(2):92-99
OBJECTIVES: The objectives of this study were to determine the radiation safety status of dental care institutions and to contribute to the development of guidelines for radiation protection in dental clinics in order to improve the work environment and reduce the radiation hazard for practitioners. METHODS: The subjects were selected using a convenience sampling. A total of 300 subjects participated in this study, including 150 dental hygienists from dental clinics in Gwangju Metropolitan City with radiation-related work experience and 150 dental hygienists who had participated in a seminar hosted by the Korean Dental Insurance Manager Association held on January 17, 2016. For the survey, self-entry questionnaires were used, and the collected data were analyzed by performing a frequency analysis using cross tabulation (χ2-test) and t-test, one-way analysis of variance, and multiple regression analysis. RESULTS: The awareness on radiation protection among dental hygienists showed 4.4 out of 5 points, which was high, but the practice of radiation protection was overall poor. For the necessity of developing radiation protection guidelines, 91.9% answered “Yes, it is necessary.”. CONCLUSIONS: The level of radiation protection practiced at dental healthcare centers was much lower than the awareness of it and showed that the requirement of guidelines for radiation protection was high. Therefore, institutional devices require the development and utilization of various types of radiation protection guidelines in order to mitigate radiation risks and improve the work environment.
Delivery of Health Care
;
Dental Care
;
Dental Clinics
;
Dental Hygienists
;
Gwangju
;
Humans
;
Insurance, Dental
;
Radiation Protection
5.Effects of commercial plum beverage on the dentin surface of bovine teeth
So Ra HWANG ; Ji Eun KIM ; Ki Ho CHUNG ; Choong Ho CHOI
Journal of Korean Academy of Oral Health 2019;43(4):178-183
OBJECTIVES: We investigated the effects of commercial plum beverage on the dentin surface that could be exposed to caries, gliopathy, and abrasion to investigate the inhibitory effects of dentin corrosion.METHODS: The experimental beverages were Jeju Samdasoo (Group 1, negative control), Coca-Cola (Group 2, positive control), Chorok Maesil (Group 3), and Chorok Maesil with 3% calcium lactate added (Group 4). The specimens were prepared and divided into 4 groups of 12 each. The pH of the experimental beverages was measured using a pH meter, and specimen surface hardness was assessed according to the Vickers hardness number (VHN). The specimens were immersed in the experimental beverage for 1, 3, 5, 10, and 15 minutes. Then, we obtained the average VHN by measuring surface microhardness. Measures of surface microhardness were compared using the paired t-test before and after 15 minutes of immersion in each of the four beverages. Between-group differences in surface microhardness were compared using one-way analysis of variance and the Tukey test after the analysis.RESULTS: After 15 minutes of immersion in the experimental beverages, there was no significant difference in surface microhardness in group 1 (P>0.05). There were significant differences in groups 2, 3, and 4 (P < 0.05). The difference in surface microhardness before and after immersion for 15 minutes was highest in group 3 (−18.1±2.55), followed by group 2 (−13.0±3.53) and group 4 (−7.79±4.47). In group 1, the difference was −1.52±4.30. Moreover, there was a significant difference in each group (P < 0.05). After 10 minutes of immersion, surface microhardness tended to rapidly decrease.CONCLUSIONS: Patients who regularly ingest a commercially available plum drink with low pH should be provided dietary guidance on the risk of dental erosion. Calcium additives should be considered when producing plum beverage products.
Beverages
;
Calcium
;
Corrosion
;
Dentin
;
Hardness
;
Humans
;
Hydrogen-Ion Concentration
;
Immersion
;
Lactic Acid
;
Prunus domestica
;
Tooth
6.Evidence-Based Clinical Practice Guideline for Fluid Therapy to Prevent Contrast-induced Nephropathy
Kyung Hae LEE ; Kyung Min SHIN ; Hyeon Jeong LEE ; So Young KIM ; JungWon CHAE ; Mi Ra KIM ; Min Young HAN ; Mi Sook AHN ; Jin Kyung PARK ; Mi Ae CHUNG ; Sang Hui CHU ; Jung Hwa HWANG
Journal of Korean Clinical Nursing Research 2017;23(1):83-90
PURPOSE: This study was to develop evidence-based clinical practice guideline in order to prevent contrast-induced nephropathy (CIN) for patients undergoing percutaneous coronary intervention (PCI). METHODS: The guideline was developed based on the “Scottish Intercollegiate Guidelines Network (SIGN)”. The first draft of guideline was developed through 5 stages and evaluated by 10 experts.(1) Clinical questions were ensured in PICO format.(2) Two researchers conducted a systematic search through electronic database, identifying 170 studies. We selected 27 full text articles including 16 randomized clinical trials, 7 systematic reviews, and 4 guidelines. Quality of each studies were evaluated by the Cochran's Risk of Bias, AMSTAR, K-AGREEII. Among the studies, 11 studies were excluded.(3) The strength of recommendations were classified and quality of recommendations were ranked.(4) Guideline draft was finalized.(5) Content-validation was conducted by an expert group. All contents were ranked above 0.8 in CVI. RESULTS: Evidence-based clinical practice guideline to prevent CIN was dveloped.(1) The guideline for preventing CIN recommends using 0.9% saline.(2) Standardized rate of fluid therapy is 1 to 1.5ml/kg/hr.(3) Execute hydration for 6~12hrs before PCI and after PCI. CONCLUSION: This study suggests evidence-based clinical practice guideline for preventing CIN which can be more efficiently used in clinical practice.
Acute Kidney Injury
;
Bias (Epidemiology)
;
Contrast Media
;
Evidence-Based Practice
;
Fluid Therapy
;
Humans
;
Percutaneous Coronary Intervention
7.Electrocardiogram PR Interval Is a Surrogate Marker to Predict New Occurrence of Atrial Fibrillation in Patients with Frequent Premature Atrial Contractions.
Kwang Jin CHUN ; Jin Kyung HWANG ; So Ra CHOI ; Seung Jung PARK ; Young Keun ON ; June Soo KIM ; Kyoung Min PARK
Journal of Korean Medical Science 2016;31(4):519-524
The clinical significance of prolonged PR interval has not been evaluated in patients with frequent premature atrial contractions (PACs). We investigated whether prolonged PR interval could predict new occurrence of atrial fibrillation (AF) in patients with frequent PACs. We retrospectively analyzed 684 patients with frequent PACs (> 100 PACs/day) who performed repeated 24-hour Holter monitoring. Prolonged PR interval was defined as longer than 200 msec. Among 684 patients, 626 patients had normal PR intervals (group A) and 58 patients had prolonged PR intervals (group B). After a mean follow-up of 59.3 months, 14 patients (24.1%) in group B developed AF compared to 50 patients (8.0%) in group A (P < 0.001). Cox regression analysis showed that prolonged PR interval (hazard ratio [HR], 1.950; 95% CI, 1.029-3.698; P = 0.041), age (HR, 1.033; 95% CI, 1.006-1.060; P = 0.015), and left atrial (LA) dimension (HR, 1.061; 95% CI, 1.012-1.112; P = 0.015) were associated with AF occurrence. Prolonged PR interval, advanced age, and enlarged LA dimension are independent risk factors of AF occurrence in patients with frequent PACs.
Adult
;
Age Factors
;
Aged
;
Area Under Curve
;
Atrial Fibrillation/*diagnosis/etiology/mortality
;
Atrial Premature Complexes/complications/*diagnosis
;
*Electrocardiography, Ambulatory
;
Female
;
Follow-Up Studies
;
Heart/diagnostic imaging
;
Humans
;
Kaplan-Meier Estimate
;
Male
;
Middle Aged
;
Predictive Value of Tests
;
Proportional Hazards Models
;
ROC Curve
;
Retrospective Studies
;
Risk Factors
;
Sex Factors
8.Vitamin-Mineral Supplement Use Patterns in Elderly Koreans: Data from the 2007-2008 Korean National Health and Nutrition Examination Survey.
So Young PARK ; Yun Jin KIM ; Sang Yeoup LEE ; Jeong Gyu LEE ; Hye Rim HWANG ; Dong Wook JEONG ; Young Hye CHO ; Eun Jung CHOI ; Yu Hyeon YI ; Young Jin TAK ; A Ra JO ; Seung Hoon LEE ; Jeong Suk JEON ; Bo Wha LEE
Korean Journal of Family Medicine 2016;37(2):123-129
BACKGROUND: Vitamin-mineral supplements are the most popular dietary supplements in Korea. However, few studies have assessed the relationship between vitamin-mineral supplementation and associated factors among the Korean elderly. The purpose of this study was to assess the use of vitamin-mineral supplements among elderly in Korea as well as its association with sociodemographic factors, health-related behaviors, medical conditions, and nutrient intake. METHODS: This study was based on data from the Korean National Health and Nutrition Examination Survey, conducted by the Korean Ministry of Health and Welfare from 2008 to 2009. Data from 3,294 elderly men and women (65 years of age and older) were analyzed. Multivariable-weighted logistic regression model analysis was used to evaluate the association between vitamin-mineral supplement use and sociodemographic factors, health-related habits, and medical conditions. RESULTS: Vitamin-mineral supplementation was reported by 16.3% of the participants. The most common reason for using dietary supplements was recommendations from friends and acquaintances. Highly educated person, female participants had a greater likelihood of taking vitamin-mineral supplements. In addition, analysis of nutrient intake from food sources alone revealed a lower proportion of vitamin-mineral supplement users with nutrient intakes below the estimated average requirements for vitamin A, vitamin C, thiamine, riboflavin, niacin, calcium, iron, and phosphorus, compared to nonusers. However, vitamin-mineral supplementation was not associated with health-related behaviors or medical conditions. CONCLUSION: Highly educated person, elderly Korean women had a greater likelihood of using vitamin-mineral supplements. In addition, nutrient intakes from food sources alone were significantly higher among vitamin-mineral supplement users. Finally, vitamin-mineral supplementation may be an indicator of healthier diet in elderly Koreans.
Aged*
;
Ascorbic Acid
;
Asian Continental Ancestry Group
;
Calcium
;
Diet
;
Dietary Supplements
;
Female
;
Friends
;
Humans
;
Iron
;
Korea
;
Logistic Models
;
Male
;
Morinda
;
Niacin
;
Nutrition Surveys*
;
Phosphorus
;
Riboflavin
;
Thiamine
;
Vitamin A
;
Vitamins
9.A Case of Gastrointestinal Sarcoidosis without Pulmonary Involvement.
Bo Young KIM ; So Ra KIM ; Jiyoung HWANG ; So Young JIN ; Hyun Sook KIM
Korean Journal of Medicine 2015;89(1):127-132
Sarcoidosis is a multisystemic granulomatous disease of unknown etiology that is based on the presence of non-caseating granulomas. Sarcoidosis commonly involves the lungs, skin, and eyes. Gastrointestinal tract involvement in sarcoidosis is uncommon. Gastrointestinal tract sarcoidosis commonly occurs subclinically, with clinical manifestations present in only 0.1-0.9% of patients with the disease. There are rare case reports of an individual with symptomatic gastrointestinal sarcoidosis. In Korea, gastrointestinal sarcoidosis without pulmonary involvement has not been reported previously. Here, we describe a case of gastrointestinal sarcoidosis in a 37-year-old male with symptoms of weight loss, fever, and abdominal pain. He was diagnosed based on the presence of non-caseating epithelioid granulomas in the stomach, duodenum, and colon by multiple biopsies.
Abdominal Pain
;
Adult
;
Biopsy
;
Colon
;
Duodenum
;
Fever
;
Gastrointestinal Tract
;
Granuloma
;
Humans
;
Korea
;
Lung
;
Male
;
Sarcoidosis*
;
Skin
;
Stomach
;
Weight Loss
10.Three cases of glycogenic hepatopathy mimicking acute and relapsing hepatitis in type I diabetes mellitus.
Jae Hwang CHA ; Sang Ho RA ; Yu Mi PARK ; Yong Kwan JI ; Ji Hyun LEE ; So Yeon PARK ; Soon Koo BAIK ; Sang Ok KWON ; Mee Yon CHO ; Moon Young KIM
Clinical and Molecular Hepatology 2013;19(4):421-425
Glycogenic hepatopathy (GH) is an uncommon cause of serum transaminase elevation in type I diabetes mellitus (DM). The clinical signs and symptoms of GH are nonspecific, and include abdominal discomfort, mild hepatomegaly, and transaminase elevation. In this report we describe three cases of patients presenting serum transaminase elevation and hepatomegaly with a history of poorly controlled type I DM. All of the cases showed sudden elevation of transaminase to more than 30 times the upper normal range (like in acute hepatitis) followed by sustained fluctuation (like in relapsing hepatitis). However, the patients did not show any symptom or sign of acute hepatitis. We therefore performed a liver biopsy to confirm the cause of liver enzyme elevation, which revealed GH. Clinicians should be aware of GH so as to prevent diagnostic delay and misdiagnosis, and have sufficient insight into GH; this will be aided by the present report of three cases along with a literature review.
Acute Disease
;
Adult
;
Alanine Transaminase/blood
;
Aspartate Aminotransferases/blood
;
Delayed Diagnosis
;
Diabetes Mellitus, Type 1/complications/*pathology
;
Diagnostic Errors
;
Female
;
Glycogen Storage Disease/complications/*diagnosis/ultrasonography
;
Hepatitis/diagnosis
;
Hepatomegaly/complications/*diagnosis/ultrasonography
;
Humans
;
Liver/pathology
;
Recurrence
;
Young Adult

Result Analysis
Print
Save
E-mail