1.Effectiveness of comprehensive rhinoplasty on secondary nasal deformity with saddle nasal deformity after cleft lip surgery.
Ming CHEN ; Zongke GUO ; Bing YU
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):56-61
OBJECTIVE:
To investigate the effectiveness of comprehensive rhinoplasty with autogenous costal cartilage grafting and prosthesis augmentation rhinoplasty in the treatment of secondary nasal deformity with saddle nasal deformity after cleft lip surgery.
METHODS:
The clinical data of 96 patients with secondary nasal deformity with saddle nasal deformity after cleft lip surgery between September 2008 and January 2019 were retrospectively analyzed. There were 17 males and 79 females with an average age of 25.6 years (range, 17-38 years). Autogenous costal cartilage grafts were used to construct stable nasal tip framework and enhance the strength of alar cartilage. Nasal dorsum prostheses (39 cases of bulge, 45 cases of silicone prosthesis) or autogenous costal cartilage (12 cases) were used for comprehensive rhinoplasty. Visual analogue scale (VAS) score was used to evaluate the postoperative satisfaction subjectively, and nasal alar height symmetry index, nasal alar width symmetry index, nasal dorsum central axis deviation angle, and nasal columella deviation angle were calculated to evaluate objectively before and after operation.
RESULTS:
All patients were followed up 6 months to 8 years, with an average of 13.4 months. Nasal septal hematoma occurred in 3 patients after operation, which was improved after local aspiration and nasal pressure packing. Two cases had mild deformation of the rib cartilage graft of the nasal dorsum, one of which had no obvious deviation of the nasal dorsum and was not given special treatment, and one case underwent the cartilage graft of the nasal dorsum removed and replaced with silicone prosthesis. The incisions of the other patients healed by first intention, and there was no complication such as postoperative infection and prosthesis displacement. The nasal alar height symmetry index, nasal alar width symmetry index, nasal dorsum central axis deviation angle, and nasal columella deviation angle significantly improved after operation when compared with preoperative ones ( P<0.05). Postoperative subjective satisfaction evaluation reached the level of basic satisfaction or above, and most of them were very satisfied.
CONCLUSION
Comprehensive rhinoplasty using autologous rib cartilage grafting to construct a stable nasal tip support, combined with dorsal nasal prosthesis or autologous cartilage implantation, can achieve good effectiveness on secondary nasal deformity with saddle nasal deformity after cleft lip surgery.
Male
;
Female
;
Humans
;
Adult
;
Rhinoplasty
;
Cleft Lip/surgery*
;
Retrospective Studies
;
Nose/surgery*
;
Nasal Septum/surgery*
;
Nasal Cartilages/surgery*
;
Silicones
;
Treatment Outcome
2.Embedded 3D printing of porous silicon orbital implants and its surface modification.
Hong ZHAO ; Yilin WANG ; Yanfang WANG ; Haihuan GONG ; Feiyang YINJUN ; Xiaojun CUI ; Jiankai ZHANG ; Wenhua HUANG
Journal of Southern Medical University 2023;43(5):783-792
OBJECTIVE:
To prepare customized porous silicone orbital implants using embedded 3D printing and assess the effect of surface modification on the properties of the implants.
METHODS:
The transparency, fluidity and rheological properties of the supporting media were tested to determine the optimal printing parameters of silicone. The morphological changes of silicone after modification were analyzed by scanning electron microscopy, and the hydrophilicity and hydrophobicity of silicone surface were evaluated by measuring the water contact angle. The compression modulus of porous silicone was measured using compression test. Porcine aortic endothelial cells (PAOECs) were co-cultured with porous silicone scaffolds for 1, 3 and 5 days to test the biocompatibility of silicone. The local inflammatory response to subcutaneous porous silicone implants was evaluated in rats.
RESULTS:
The optimal printing parameters of silicone orbital implants were determined as the following: supporting medium 4% (mass ratio), printing pressure 1.0 bar and printing speed 6 mm/s. Scanning electron microscopy showed that the silicone surface was successfully modified with polydopamine and collagen, which significantly improved hydrophilicity of the silicone surface (P < 0.05) without causing significant changes in the compression modulus (P > 0.05). The modified porous silicone scaffold had no obvious cytotoxicity and obviously promoted adhesion and proliferation of PAOECs (P < 0.05). In rats bearing the subcutaneous implants, no obvious inflammation was observed in the local tissue.
CONCLUSION
Poprous silicone orbital implants with uniform pores can be prepared using embedded 3D printing technology, and surface modification obviously improves hydrophilicity and biocompatibility of the silicone implants for potential clinical application.
Animals
;
Rats
;
Swine
;
Silicon
;
Orbital Implants
;
Endothelial Cells
;
Porosity
;
Silicones
;
Printing, Three-Dimensional
3.Synthesis of a novel injectable alginate impression material and impression accuracy evaluation.
Xingzi LIU ; Xinhui WANG ; Jingya WU ; Jingjing LUO ; Yun WANG ; Quanli LI
West China Journal of Stomatology 2022;40(6):662-667
OBJECTIVES:
This work aimed to synthesize a novel injectable alginate impression material and evaluate its accuracy.
METHODS:
Certain proportions of sodium alginate, trisodium phosphate dodecahydrate, potassium fluorotitanate, diatomaceous earth, and other ingredients were dissolved in water and mixed evenly with a planetary centrifugal mixer to obtain a certain viscosity base paste. Certain proportions of calcium sulfate hemihydrate, magnesium oxide, glycerin, and polyethylene glycol (PEG) 400 were mixed evenly with a planetary centrifugal mixer to obtain the reactor paste with the same viscosity as the base paste. The base and reactor pastes were poured into a two-cylinder cartridge at a 2∶1 volume ratio. A gun device was used to accomplish mixing by compressing materials into a mixing tip. The samples were divided into three groups: injectable alginate impression materials (IA group) as the experimental group, and Jeltrate alginate impression materials (JA group) and Silagum-putty/light addition silicone rubber impression materials (SI group) as the two control groups.
RESULTS:
Scanning electron microscopy (SEM) showed that the injectable alginate impression materials had a denser structure and fewer bubbles than the commercial alginate impression material. The accuracy of the three kinds of impression materials was evaluated by 3D image superposition. The deviations between the three test group models and the standard model (trueness) were 49.58 μm±1.453 μm (IA group), 54.75 μm±7.264 μm (JA group), and 30.92 μm±1.013 μm (SI group). The deviations of the models within each test group (precision) were 85.79 μm±8.191 μm (IA group), 97.65 μm±11.060 μm (JA group), and 56.51 μm±4.995 μm (SI group). Significant differences in trueness and precision were found among the three kinds of impression materials (P<0.05).
CONCLUSIONS
The accuracy of the new injectable alginate impression material was better than that of the traditional powder-type alginate impression material but worse than that of the addition silicone rubber impression materials. The novel injec-table alginate impression material demonstrated good operation performance and impression accuracy, showing broad application prospect.
Alginates/chemistry*
;
Silicone Elastomers/chemistry*
;
Dental Impression Materials/chemistry*
;
Powders
4.Endophthalmitis Caused by Mixed Infections in Silicone Oil-filled Eye:One Case Report.
Jun-Yan XIAO ; Di CHEN ; Wen-Jing LIU ; Han-Yi MIN
Acta Academiae Medicinae Sinicae 2021;43(4):659-662
The incidence of endophthalmitis after vitrectomy is extremely low,especially lower in silicone oil-filled eyes.Silicone oil exerts a toxic effect on the cell membranes of microorganisms and leads to the lack of nutrients.It is thus believed to inhibit the growth of bacteria and fungi.Endophthalmitis induced by mixed bacteria in silicone oil-filled eye has been rarely reported.We reviewed the clinical manifestations,diagnosis,and treatment of a patient with endophthalmitis caused by mixed infection of
Bacteria
;
Coinfection
;
Endophthalmitis
;
Humans
;
Silicone Oils/adverse effects*
;
Vitrectomy
5.Application of iPDMS protein microarray in screening of tumor-associated antigen autoantibodies.
Fan CHEN ; Wei WANG ; Dayong GU ; Yongbo NIE ; Zhengqin XIAO ; Kaiyu HUANG ; Hongwei MA ; Jianan HE ; Fan YANG
Chinese Journal of Biotechnology 2021;37(11):4075-4082
The rapid screening of tumor markers is a challenging task for early diagnosis of cancer. This study aims to use highly sensitive chemiluminescent protein microarray technology to efficiently screen a variety of low abundance tumor related markers. A new material, termed integrated polydimethylsiloxane modified silica gel (iPDMS), was obtained by adding a surface polymerization initiator with olefin end to the conventional polydimethylsiloxane, and fixing into the three-dimensional structure of polydimethylsiloxane by thermal crosslinking through silicon hydrogen bonding. In order to make the iPDMS material resistant to non-specific protein adsorption, a poly(OEGMA) polymer brush was synthesized by surface-initiated atom transfer radical polymerization at the active initiation site. Finally, 20 tumor-related antigens were printed into the specific areas of the microarray by high-throughput spray printing technology, and assembled into 48-well detection microtiterplates of the iPDMS microarray. It was found the VEGFR and VEGF121 autoantibodies that obtained from 8 common tumors (breast cancer, lung cancer, colon cancer, gastric cancer, liver cancer, leukemia, lymphoma and ovarian cancer) can be used as potential tumor markers. The chemiluminescence labeled iPDMS protein microarray can be used for the screening of tumor autoantibodies at early stage.
Adsorption
;
Autoantibodies
;
Dimethylpolysiloxanes
;
Protein Array Analysis
;
Silica Gel
;
Surface Properties
7.Retinal Toxicity Following the Injection Ganciclovir into Silicone Oil-filled Eye to Treat Acute Retinal Necrosis
Yeon Ji JO ; Seung Kwon CHOI ; Sun Ho PARK ; Jae Jung LEE ; Ji Eun LEE ; Sung Who PARK
Journal of the Korean Ophthalmological Society 2020;61(1):111-115
PURPOSE: To report a case of retinal toxicity after an intravitreal ganciclovir injection to treat acute retinal necrosis in an eye filled with silicone oil.CASE SUMMARY: A 56-year-old male presented with ocular pain and visual loss in his right eye. His best-corrected visual acuity was 20/25, inflammatory cells in the anterior chamber, multiple retinitis lesions and retinal vessel occlusions in the peripheral retina and vitreous opacity were showed. Acute retinal necrosis was suspected, anterior chamber polymerase chain reaction (PCR) test was done. Aciclovir 2,400 mg/day intravenously and ganciclovir 2.0 mg were administered by intravitreal injection. After 4 days, retinitis was worsened and PCR test was positive for varicella zoster virus. Ganciclovir intravitreal injections were increased twice a week. After 16 days, retinal detachment occurred, so scleral encircling, vitrectomy, laser photocoagulation, and silicone oil tamponade were conducted. Ganciclovir 1.0 mg was injected at the end of surgery. The patient's visual acuity decreased to hand motion, and multiple crystal deposits with multiple retinal hemorrhages were observed in the right eye the next day. Visual acuity did not recover and optical coherent tomography showed that the macula was thinned.CONCLUSIONS: Visual loss seemed to be related with the retinal toxicity of ganciclovir. The increased local concentration due to the silicone oil tamponade is thought to have caused the toxicity.
Acyclovir
;
Anterior Chamber
;
Ganciclovir
;
Hand
;
Herpesvirus 3, Human
;
Humans
;
Intravitreal Injections
;
Light Coagulation
;
Male
;
Middle Aged
;
Polymerase Chain Reaction
;
Retina
;
Retinal Detachment
;
Retinal Hemorrhage
;
Retinal Necrosis Syndrome, Acute
;
Retinal Vessels
;
Retinaldehyde
;
Retinitis
;
Silicon
;
Silicones
;
Visual Acuity
;
Vitrectomy
8.Optimal Bowel Preparation for Capsule Endoscopy and Device-assisted Enteroscopy
The Korean Journal of Gastroenterology 2020;75(2):74-78
For improved examination of video capsule endoscopy (VCE) and device-assisted enteroscopy (DAE), bowel preparation is an essential issue. Multiple factors like air bubbles, food material in the small bowel, and gastric and small bowel transit time affect the small bowel visualization quality (SBVQ), diagnostic yield (DY) and cecal completion rate (CR). Bowel preparation with polyethylene glycol (PEG) solution enhances SBVQ and DY, but it has no effect on CR. Bowel preparation with PEG solution 2 L is similar to PEG 4 L in SBVQ, DY, and CR. Bowel preparation with fasting or PEG solution combined with anti-foaming agents like simethicone enhance SBVQ, but it has no effect on CR. Bowel preparation with prokinetics is not commonly recommended. Optimal timing for purgative bowel preparation has yet to be established. However, the studies regarding bowel preparation for DAE are not sufficient. European Society of Gastrointestinal Endoscopy (ESGE) recommends 8–12 hours fasting from solid food and 4–6 hours fasting from liquids prior to the antegrade DAE. For retrograde DAE, colonoscopy preparation regimen is recommended. This article reviews the literature and ESGE, 2013 Korean published guidelines regarding bowel preparation for VCE and DAE, following suggestion for optimal bowel preparation for VCE and balloon enteroscopy.
Capsule Endoscopy
;
Cathartics
;
Colonoscopy
;
Endoscopy, Gastrointestinal
;
Fasting
;
Polyethylene Glycols
;
Simethicone
9.Natural Latex Rubber Condom Inspection and Exploratory Research Analysis.
Yucheng ZHANG ; Haiyan WANG ; Fang HU
Chinese Journal of Medical Instrumentation 2020;44(2):163-165
According to the situation of 34 batches of natural rubber latex condoms tested by our center in 2018, the unqualified items in the product inspection items and the exploratory research results of D4 and D5 content in silicone oil lubricants are analyzed. We make recommendations on product technical requirements or standards to strengthen the quality supervision of products.
Condoms/standards*
;
Latex
;
Silicone Oils
10.Effects of different surface finishing protocols for zirconia on surface roughness and bacterial biofilm formation
Du Hyeong LEE ; Hang Nga MAI ; Phyu Pwint THANT ; Su Hyung HONG ; Jaewon KIM ; Seung Mi JEONG ; Keun Woo LEE
The Journal of Advanced Prosthodontics 2019;11(1):41-47
PURPOSE: Surface finishing of a zirconia restoration is essential after clinical adjustment. Herein, we investigated the effects of a surface finishing protocol for monolithic zirconia on final roughness and bacterial adherence. MATERIALS AND METHODS: Forty-eight disk-shaped monolithic zirconia specimens were fabricated and divided into four groups (n = 12) based on initial surface treatment, finishing, and polishing protocols: diamond bur+polishing bur (DP group), diamond bur+stone grinding bur+polishing bur (DSP group), no diamond bur+polishing bur (NP group), and no diamond bur+stone grinding bur+polishing bur (NSP group). Initial and final surface roughness was measured with a profilometer, and shown using scanning electron microscope. Bacterial adhesion was evaluated by quantifying Streptococcus mutans in the biofilm. Kruskal-Wallis and Mann-Whitney U tests were used to compare results among groups, and two-way analysis of variance was used to evaluate the effects of grinding burs on final roughness (α=.05). RESULTS: The DP group had the highest final Ra value, followed by the DSP, NP, and NSP groups. Use of the stone grinding bur as a coarse-finishing step significantly decreased final Ra values when a diamond bur was used (P < .001). Omission of the stone grinding bur increased biofilm formation on specimen surfaces. Combining a stone grinding bur with silicone polishing burs produced the smallest final biofilm values, regardless of the use of a diamond bur in initial surface treatment. CONCLUSION: Coarse finishing of monolithic zirconia with a stone grinding bur significantly decreased final Ra values and bacterial biofilm formation when surfaces had been roughened by a diamond bur.
Bacterial Adhesion
;
Biofilms
;
Dental Instruments
;
Dental Polishing
;
Diamond
;
Silicon
;
Silicones
;
Streptococcus mutans

Result Analysis