1.Recognition of motor imagery electroencephalogram based on flicker noise spectroscopy and weighted filter bank common spatial pattern.
Keling FEI ; Xiaoxian CAI ; Shunzhi CHEN ; Lizheng PAN ; Wei WANG
Journal of Biomedical Engineering 2023;40(6):1126-1134
Due to the high complexity and subject variability of motor imagery electroencephalogram, its decoding is limited by the inadequate accuracy of traditional recognition models. To resolve this problem, a recognition model for motor imagery electroencephalogram based on flicker noise spectrum (FNS) and weighted filter bank common spatial pattern ( wFBCSP) was proposed. First, the FNS method was used to analyze the motor imagery electroencephalogram. Using the second derivative moment as structure function, the ensued precursor time series were generated by using a sliding window strategy, so that hidden dynamic information of transition phase could be captured. Then, based on the characteristic of signal frequency band, the feature of the transition phase precursor time series and reaction phase series were extracted by wFBCSP, generating features representing relevant transition and reaction phase. To make the selected features adapt to subject variability and realize better generalization, algorithm of minimum redundancy maximum relevance was further used to select features. Finally, support vector machine as the classifier was used for the classification. In the motor imagery electroencephalogram recognition, the method proposed in this study yielded an average accuracy of 86.34%, which is higher than the comparison methods. Thus, our proposed method provides a new idea for decoding motor imagery electroencephalogram.
Brain-Computer Interfaces
;
Imagination
;
Signal Processing, Computer-Assisted
;
Electroencephalography/methods*
;
Algorithms
;
Spectrum Analysis
2.Detection method of early heart valve diseases based on heart sound features.
Chengfa SUN ; Xinpei WANG ; Changchun LIU
Journal of Biomedical Engineering 2023;40(6):1160-1167
Heart valve disease (HVD) is one of the common cardiovascular diseases. Heart sound is an important physiological signal for diagnosing HVDs. This paper proposed a model based on combination of basic component features and envelope autocorrelation features to detect early HVDs. Initially, heart sound signals lasting 5 minutes were denoised by empirical mode decomposition (EMD) algorithm and segmented. Then the basic component features and envelope autocorrelation features of heart sound segments were extracted to construct heart sound feature set. Then the max-relevance and min-redundancy (MRMR) algorithm was utilized to select the optimal mixed feature subset. Finally, decision tree, support vector machine (SVM) and k-nearest neighbor (KNN) classifiers were trained to detect the early HVDs from the normal heart sounds and obtained the best accuracy of 99.9% in clinical database. Normal valve, abnormal semilunar valve and abnormal atrioventricular valve heart sounds were classified and the best accuracy was 99.8%. Moreover, normal valve, single-valve abnormal and multi-valve abnormal heart sounds were classified and the best accuracy was 98.2%. In public database, this method also obtained the good overall accuracy. The result demonstrated this proposed method had important value for the clinical diagnosis of early HVDs.
Humans
;
Heart Sounds
;
Heart Valve Diseases/diagnosis*
;
Algorithms
;
Support Vector Machine
;
Signal Processing, Computer-Assisted
3.Anti-motion Artifact Performance Test System for Ambulatory ECG Monitoring Equipment.
Liping QIN ; Yi WU ; Ke XU ; Xiangrui ZHAO
Chinese Journal of Medical Instrumentation 2023;47(6):624-629
Anti-motion artifact is one of the most important properties of ambulatory ECG monitoring equipment. At present, there is a lack of standardized means to test the performance of anti-motion artifact. ECG simulator and special conductive leather are used to build the simulator, it is used to simulate human skin, to generate ECG signal input for the ECG monitoring equipment attached to it. The mechanical arm and fixed support are used to build a motion simulation system to fix the conductive leather. The mechanical arm is programmed to simulate various motion states of the human body, so that the ECG monitoring equipment can produce corresponding motion artifacts. The collected ECG signals are read wirelessly, observed, analyzed and compared, and the anti-motion artifact performance of ECG monitoring equipment is evaluated. The test results show that by artificially creating the small difference between the two groups of ambulatory ECG monitoring equipment, the system can accurately test the interference signals introduced under the conditions of controlled movement such as tension and torsion, and compare the advantages and disadvantages. The research shows that the test system can provide convenient and accurate verification means for the research of optimizing anti-motion interference.
Humans
;
Artifacts
;
Signal Processing, Computer-Assisted
;
Electrocardiography, Ambulatory/methods*
;
Electrocardiography
;
Motion
4.Automatic sleep staging algorithm for stochastic depth residual networks based on transfer learning.
Yunzhi TIAN ; Qiang ZHOU ; Wan LI
Journal of Biomedical Engineering 2023;40(2):286-294
The existing automatic sleep staging algorithms have the problems of too many model parameters and long training time, which in turn results in poor sleep staging efficiency. Using a single channel electroencephalogram (EEG) signal, this paper proposed an automatic sleep staging algorithm for stochastic depth residual networks based on transfer learning (TL-SDResNet). Firstly, a total of 30 single-channel (Fpz-Cz) EEG signals from 16 individuals were selected, and after preserving the effective sleep segments, the raw EEG signals were pre-processed using Butterworth filter and continuous wavelet transform to obtain two-dimensional images containing its time-frequency joint features as the input data for the staging model. Then, a ResNet50 pre-trained model trained on a publicly available dataset, the sleep database extension stored in European data format (Sleep-EDFx) was constructed, using a stochastic depth strategy and modifying the output layer to optimize the model structure. Finally, transfer learning was applied to the human sleep process throughout the night. The algorithm in this paper achieved a model staging accuracy of 87.95% after conducting several experiments. Experiments show that TL-SDResNet50 can accomplish fast training of a small amount of EEG data, and the overall effect is better than other staging algorithms and classical algorithms in recent years, which has certain practical value.
Humans
;
Sleep Stages
;
Algorithms
;
Sleep
;
Wavelet Analysis
;
Electroencephalography/methods*
;
Machine Learning
5.A semi-supervised material quantitative intelligent imaging algorithm for spectral CT based on prior information perception learning.
Zheng DUAN ; Danyang LI ; Dong ZENG ; Zhaoying BIAN ; Jianhua MA
Journal of Southern Medical University 2023;43(4):620-630
OBJECTIVE:
To propose a semi-supervised material quantitative intelligent imaging algorithm based on prior information perception learning (SLMD-Net) to improve the quality and precision of spectral CT imaging.
METHODS:
The algorithm includes a supervised and a self- supervised submodule. In the supervised submodule, the mapping relationship between low and high signal-to-noise ratio (SNR) data was constructed through mean square error loss function learning based on a small labeled dataset. In the self- supervised sub-module, an image recovery model was utilized to construct the loss function incorporating the prior information from a large unlabeled low SNR basic material image dataset, and the total variation (TV) model was used to to characterize the prior information of the images. The two submodules were combined to form the SLMD-Net method, and pre-clinical simulation data were used to validate the feasibility and effectiveness of the algorithm.
RESULTS:
Compared with the traditional model-driven quantitative imaging methods (FBP-DI, PWLS-PCG, and E3DTV), data-driven supervised-learning-based quantitative imaging methods (SUMD-Net and BFCNN), a material quantitative imaging method based on unsupervised learning (UNTV-Net) and semi-supervised learning-based cycle consistent generative adversarial network (Semi-CycleGAN), the proposed SLMD-Net method had better performance in both visual and quantitative assessments. For quantitative imaging of water and bone materials, the SLMD-Net method had the highest PSNR index (31.82 and 29.06), the highest FSIM index (0.95 and 0.90), and the lowest RMSE index (0.03 and 0.02), respectively) and achieved significantly higher image quality scores than the other 7 material decomposition methods (P < 0.05). The material quantitative imaging performance of SLMD-Net was close to that of the supervised network SUMD-Net trained with labeled data with a doubled size.
CONCLUSIONS
A small labeled dataset and a large unlabeled low SNR material image dataset can be fully used to suppress noise amplification and artifacts in basic material decomposition in spectral CT and reduce the dependence on labeled data-driven network, which considers more realistic scenario in clinics.
Tomography, X-Ray Computed/methods*
;
Image Processing, Computer-Assisted/methods*
;
Algorithms
;
Signal-To-Noise Ratio
;
Perception
6.Heartbeat-aware convolutional neural network for R-peak detection of wearable device ECG data.
Hui Xin TAN ; Jie Wei LAI ; Zuo WANG ; Lei JI ; Yi Hang ZHANG ; Jin Liang WANG ; Yu Zhang SONG ; Wei YANG
Journal of Southern Medical University 2022;42(3):375-383
OBJECTIVE:
To develop a method for R-peak detection of ECG data from wearable devices to allow accurate estimation of the physiological parameters including heart rate and heart rate variability.
METHODS:
A fully convolutional neural network was applied to predict the R-peak heatmap of ECG data and locate the R-peak positions. The heartbeat-aware (HA) module was introduced to enable the model to learn to predict the heartbeat number and R-peak heatmap simultaneously, thereby improving the capability of the model for extraction of the global context. The R-R interval estimated by the predicted heartbeat number was adopted to calculate the minimum horizontal distance for peak positioning. To achieve real-time R-peak detection on mobile devices, the deep separable convolution was adopted to reduce the number of parameters and the computational complexity of the model.
RESULTS:
The proposed model was trained only with ECG data from wearable devices. At a tolerance window interval of 150 ms, the proposed method achieved R peak detection sensitivities of 100% for both wearable device ECG dataset and a public dataset (i.e. LUDB), and the true positivity rates exceeded 99.9%. As for the ECG signal of a 10 s duration, the CPU time of the proposed method for R-peak detection was about 23.2 ms.
CONCLUSION
The proposed method has good performance for R-peak detection of both wearable device ECG data and routine ECG data and also allows real-time R-peak detection of the ECG data.
Algorithms
;
Electrocardiography
;
Heart Rate
;
Neural Networks, Computer
;
Signal Processing, Computer-Assisted
;
Wearable Electronic Devices
7.A nonlocal spectral similarity-induced material decomposition method for noise reduction of dual-energy CT images.
Lei WANG ; Yong Bo WANG ; Zhao Ying BIAN ; Jian Hua MA ; Jing HUANG
Journal of Southern Medical University 2022;42(5):724-732
OBJECTIVE:
To propose a nonlocal spectral similarity-induced material decomposition network (NSSD-Net) to reduce the correlation noise in the low-dose spectral CT decomposed images.
METHODS:
We first built a model-driven iterative decomposition model for dual-energy CT, optimized the objective function solving process using the iterative shrinking threshold algorithm (ISTA), and cast the ISTA decomposition model into the deep learning network. We then developed a novel cost function based on the nonlocal spectral similarity to constrain the training process. To validate the decomposition performance, we established a material decomposition dataset by real patient dual-energy CT data. The NSSD-Net was compared with two traditional model-driven material decomposition methods, one data-based material decomposition method and one data-model coupling-driven material decomposition supervised learning method.
RESULTS:
The quantitative results showed that compared with the two traditional methods, the NSSD-Net method obtained the highest PNSR values (31.383 and 31.444) and SSIM values (0.970 and 0.963) and the lowest RMSE values (2.901 and 1.633). Compared with the datamodel coupling-driven supervised decomposition method, the NSSD-Net method obtained the highest SSIM values on water and bone decomposed results. The results of subjective image quality assessment by clinical experts showed that the NSSD-Net achieved the highest image quality assessment scores on water and bone basis material (8.625 and 8.250), showing significant differences from the other 4 decomposition methods (P < 0.001).
CONCLUSION
The proposed method can achieve high-precision material decomposition and avoid training data quality issues and model unexplainable issues.
Algorithms
;
Humans
;
Image Processing, Computer-Assisted/methods*
;
Phantoms, Imaging
;
Signal-To-Noise Ratio
;
Tomography, X-Ray Computed/methods*
;
Water
8.Heart rate extraction algorithm based on adaptive heart rate search model.
Ronghao MENG ; Zhuoshi LI ; Helong YU ; Qichao NIU
Journal of Biomedical Engineering 2022;39(3):516-526
Photoplethysmography (PPG) is a non-invasive technique to measure heart rate at a lower cost, and it has been recently widely used in smart wearable devices. However, as PPG is easily affected by noises under high-intensity movement, the measured heart rate in sports has low precision. To tackle the problem, this paper proposed a heart rate extraction algorithm based on self-adaptive heart rate separation model. The algorithm firstly preprocessed acceleration and PPG signals, from which cadence and heart rate history were extracted respectively. A self-adaptive model was made based on the connection between the extracted information and current heart rate, and to output possible domain of the heart rate accordingly. The algorithm proposed in this article removed the interference from strong noises by narrowing the domain of real heart rate. From experimental results on the PPG dataset used in 2015 IEEE Signal Processing Cup, the average absolute error on 12 training sets was 1.12 beat per minute (bpm) (Pearson correlation coefficient: 0.996; consistency error: -0.184 bpm). The average absolute error on 10 testing sets was 3.19 bpm (Pearson correlation coefficient: 0.990; consistency error: 1.327 bpm). From experimental results, the algorithm proposed in this paper can effectively extract heart rate information under noises and has the potential to be put in usage in smart wearable devices.
Algorithms
;
Heart Rate/physiology*
;
Photoplethysmography/methods*
;
Signal Processing, Computer-Assisted
;
Wearable Electronic Devices
9.Development of Respiratory Signal Monitoring System Based on Photoplethysmography.
Chenqin LIU ; Sinian YUAN ; Gaozang LIN ; Shijie CAI ; Jilun YE ; Xu ZHANG ; Hao JIN
Chinese Journal of Medical Instrumentation 2022;46(4):368-372
Breathing is of great significance in the monitoring of patients with obstructive sleep apnea hypopnea syndrome, perioperative monitoring and intensive care. In this study, a respiratory monitoring and verification system based on optical capacitance product pulse wave (PPG) is designed, which can synchronously collect human PPG signals. Through algorithm processing, the characteristic parameters of PPG signal are calculated, and the respiratory signal and respiratory frequency can be extracted in real time. In order to verify the accuracy of extracting respiratory signal and respiratory rate by the algorithm, the system adds the nasal airflow respiratory signal acquisition module to synchronously collect the nasal airflow respiratory signal as the standard signal for comparison and verification. Finally, the root mean square error between the respiratory rate extracted by the algorithm from the pulse wave and the standard respiratory rate is only 1.05 times/min.
Algorithms
;
Electrocardiography
;
Heart Rate
;
Humans
;
Photoplethysmography
;
Respiration
;
Respiratory Rate
;
Signal Processing, Computer-Assisted
;
Sleep Apnea, Obstructive
10.Portable Multi Channel EEG Signal Acquisition System.
Hangyu LE ; Zifu ZHU ; Sinian YUAN ; Zichen LIU ; Gaozang LIN ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2022;46(4):404-407
This study introduces a portable multi-channel EEG signal acquisition system. The system is mainly composed of EEG electrode connector, signal conditioning circuit, EEG acquisition part, main control MCU and power supply part. The low-power EEG acquisition front-end ADS1299 and STM32 are used to form the signal acquisition and data communication part. The collected EEG signal can be transmitted to the PC for real-time display. After relevant tests, the system has small volume, low power consumption, high signal-to-noise ratio, and meets the requirements of portable wearable medical devices.
Electric Power Supplies
;
Electrodes
;
Electroencephalography
;
Signal Processing, Computer-Assisted
;
Signal-To-Noise Ratio

Result Analysis