1.Progress in the study of anti-inflammatory active components with anti-inflammatory effects and mechanisms in Caragana Fabr.
Yu-mei MA ; Ju-yuan LUO ; Tao CHEN ; Hong-mei LI ; Cheng SHEN ; Shuo WANG ; Zhi-bo SONG ; Yu-lin LI
Acta Pharmaceutica Sinica 2025;60(1):58-71
The plants of the genus
2.Correlation between CRAB Symptoms and Antioxidant Enzyme Activity in Patients with Multiple Myeloma
Xiao-Xu ZHANG ; You-Zhi ZHANG ; Yu-Shuo MA ; Wei WANG
Journal of Experimental Hematology 2024;32(2):493-498
Objective:To investigate the relationship between clinical indicators of CRAB symptoms and antioxidant enzyme activity in patients with multiple myeloma(MM).Methods:The activity of catalase(CAT),glutathione peroxidase(GPX),and superoxide dismutase(SOD)in the bone marrow supernatants of 44 patients with MM and 12 patients with non-malignant hematological diseases was detected by colorimetric assay,and then the differences in the activity of antioxidant enzymes between the two groups were compared.Furthermore,the relationship between the activity of antioxidant enzymes in the MM group and the levels of serum calcium,serum creatinine(Scr),hemoglobin(Hb),alkaline phosphatase(ALP)as well as bone lesions were analyzed.Results:The antioxidant enzyme activity was lower in MM patients compared with the control group(P<0.05).When the concentrations of serum calcium and ALP were higher than the normal levels,Hb was lower than 85 g/L,and there were multiple bone lesions,the activity of CAT,SOD and GPX was significantly declined(P<0.05);When the concentration of Scr≥177 μmol/L,the activity of GPX was significantly declined(P<0.05).Regression analyses showed that CAT,SOD and GPX were negatively correlated with serum calcium(r=-0.538,r=-0.456,r=-0.431),Scr(r=-0.342,r=-0.384,r=-0.463),and ALP(r=-0.551,r=-0.572,r=-0.482).Conclusion:The activity of antioxidant enzymes,including CAT,SOD and GPX,were decreased in patients with MM and they were negatively correlated with some clinical indicators of CRAB symptoms(such as serum calcium,Scr,and ALP),which suggests that promoting the activity of antioxidant enzymes may be beneficial to treat the CRAB symptoms of the patients with MM.
3.Simultaneous content determination of fifteen constituents in Binglang Sixiao Pills by HPLC
Yuan WANG ; Yuan-Shuo YANG ; Si-Zhi LI ; Jia-Meng ZHAO
Chinese Traditional Patent Medicine 2024;46(8):2493-2498
AIM To establish an HPLC method for the simultaneous content determination of gallic acid,catechin,epicatechin,rhein 8-O-β-D-glucoside,chlorogenic acid,chrysophanol 8-O-β-D-glucoside,emodin-8-O-β-D-glucoside,emodin-3-methyl ether-8-O-β-D-glucoside,aloe emodin,rhein,cyperotundone,luteolin,α-cyperone,emodin,chrysophanol and emodin-3-methyl ether in Binglang Sixiao Pills.METHODS The analysis was performed on a 30℃thermostatic Kromasil C18 column(250 mm×4.6 mm,5 μm),with the mobile phase comprising of methanol-0.1%formic acid flowing at 1.0 mL/min in a gradient elution manner,and the detection wavelength was set at 260 nm.Subsequently,cluster analysis and principal component analysis were made.RESULTS Fifteen constituents showed good linear relationships within their own ranges(r>0.999 0),whose average recoveries were 96.00%-101.00%%with the RSDs of 0.50%-1.50%.Various batches of samples were clustered into two categories,and four principal components demonstrated the accumulative variance contribution rate of 90.004%.CONCLUSION This simple,accurate and reproducible method can be used for the quality control of Binglang Sixiao Pills.
4.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
5.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
6.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
7.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
8.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
9.Comparison of mouse models of depression induced by different modeling methods.
Pei-Pei LI ; Shuo WANG ; Tao CHEN ; Ruo-Lan LONG ; Dan FENG ; Yang-Fei WEI ; Zhi-Bo SONG ; Yu-Lin LI ; Jing SUN
Acta Physiologica Sinica 2023;75(3):379-389
The present article was aimed to compare the effectiveness of different induction methods for depression models. Kunming mice were randomly divided into chronic unpredictable mild stress (CUMS) group, corticosterone (CORT) group, and CUMS+CORT (CC) group. The CUMS group received CUMS stimulation for 4 weeks, and the CORT group received subcutaneous injection of 20 mg/kg CORT into the groin every day for 3 weeks. The CC group received both CUMS stimulation and CORT administration. Each group was assigned a control group. After modeling, forced swimming test (FST), tail suspension test (TST) and sucrose preference test (SPT) were used to detect the behavioral changes of mice, and the serum levels of brain-derived neurotrophic factor (BDNF), 5-hydroxytryptamine (5-HT) and CORT were detected with ELISA kits. Attenuated total refraction (ATR) spectra of mouse serum were collected and analyzed. HE staining was used to detect morphological changes in mouse brain tissue. The results showed that the weight of model mice from the CUMS and CC groups decreased significantly. There was no significant change in immobility time of model mice from the three groups in FST and TST, while the glucose preference of model mice from the CUMS and CC groups was significantly reduced (P < 0.05). The serum 5-HT levels of model mice from the CORT and CC groups were significantly reduced, while the serum BDNF and CORT levels of model mice from the CUMS, CORT, and CC groups showed no significant changes. Compared with their respective control groups, the three groups showed no significant difference in the one-dimensional spectrum of serum ATR. The difference spectrum analysis results of the first derivative of the spectrogram showed that the CORT group had the greatest difference from its respective control group, followed by the CUMS group. The structures of hippocampus in the model mice from the three groups were all destroyed. These results suggest that both CORT and CC treatments can successfully construct a depression model, and the CORT model is more effective than the CC model. Therefore, CORT induction can be used to establish a depression model in Kunming mice.
Mice
;
Animals
;
Depression/etiology*
;
Antidepressive Agents/pharmacology*
;
Brain-Derived Neurotrophic Factor
;
Serotonin
10.Comparative study of purgative pharmacological effects and mechanisms of Moringa oleifera leaves and Rhei Radix et Rhizoma.
Xing-Nan YUE ; Shuo WANG ; Bin YANG ; Shu-Yi FENG ; Rao FU ; Chun-Hui QU ; Zhi-Yong LI
China Journal of Chinese Materia Medica 2023;48(19):5259-5270
Moringa oleifera leaves are known for their "Virechana"(purgative) effect in Ayurvedic medicine in India. This study compared the purgative effects and mechanisms of M. oleifera leaves with the reference Rhei Radix et Rhizoma to establish a foundation for the further application of M. oleifera leaves in traditional Chinese medicine(TCM). Using network pharmacology and molecular docking methods, this study identified the material basis, common targets, and signaling pathways through which Rhei Radix et Rhizoma and M. oleifera leaves exerted their purgative pharmacological effects. A low-fiber diet-induced constipation mouse model was established to measure fecal parameters and small intestinal propulsion rate, and histological changes in the colon were observed using HE staining. Relative expression levels of relevant genes and target proteins were assessed using RT-qPCR and immunohistochemistry, respectively. The results showed that mapping the targets of Rhei Radix et Rhizoma and M. oleifera leaves onto the biological process network of constipation revealed close proximity, indicating that they may exert their therapeutic effects on constipation through similar biological processes. Molecular docking results indicated that compounds such as sennoside C and isoquercitrin could target serine/threonine protein kinases(AKT1) and mitogen-activated protein kinase 3(MAPK3), thereby affecting MAPK and calcium signaling pathways to promote defecation. Animal experiments demonstrated that both M. oleifera leaves and Rhei Radix et Rhizoma increased the number of fecal pellets and water content in constipated mice, improved small intestine motility, colon mucosal thickness, and muscle layer thickness, upregulated the gene expression levels of AKT1 and MAPK3 in the colon, and downregulated the expression of AQP3 protein. These findings suggest that M. oleifera leaves and Rhei Radix et Rhizoma share similarities in their therapeutic efficacy and mechanisms for treating constipation. Using Rhei Radix et Rhizoma as a reference can provide a better understanding of the characteristics of the "Virechana"(purgative) effect of M. oleifera leaves in TCM.
Mice
;
Animals
;
Cathartics
;
Moringa oleifera
;
Molecular Docking Simulation
;
Drugs, Chinese Herbal/chemistry*
;
Constipation

Result Analysis
Print
Save
E-mail