1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Expert consensus on difficulty assessment of endodontic therapy
Huang DINGMING ; Wang XIAOYAN ; Liang JINGPING ; Ling JUNQI ; Bian ZHUAN ; Yu QING ; Hou BENXIANG ; Chen XINMEI ; Li JIYAO ; Ye LING ; Cheng LEI ; Xu XIN ; Hu TAO ; Wu HONGKUN ; Guo BIN ; Su QIN ; Chen ZHI ; Qiu LIHONG ; Chen WENXIA ; Wei XI ; Huang ZHENGWEI ; Yu JINHUA ; Lin ZHENGMEI ; Zhang QI ; Yang DEQIN ; Zhao JIN ; Pan SHUANG ; Yang JIAN ; Wu JIAYUAN ; Pan YIHUAI ; Xie XIAOLI ; Deng SHULI ; Huang XIAOJING ; Zhang LAN ; Yue LIN ; Zhou XUEDONG
International Journal of Oral Science 2024;16(1):15-25
Endodontic diseases are a kind of chronic infectious oral disease.Common endodontic treatment concepts are based on the removal of inflamed or necrotic pulp tissue and the replacement by gutta-percha.However,it is very essential for endodontic treatment to debride the root canal system and prevent the root canal system from bacterial reinfection after root canal therapy(RCT).Recent research,encompassing bacterial etiology and advanced imaging techniques,contributes to our understanding of the root canal system's anatomy intricacies and the technique sensitivity of RCT.Success in RCT hinges on factors like patients,infection severity,root canal anatomy,and treatment techniques.Therefore,improving disease management is a key issue to combat endodontic diseases and cure periapical lesions.The clinical difficulty assessment system of RCT is established based on patient conditions,tooth conditions,root canal configuration,and root canal needing retreatment,and emphasizes pre-treatment risk assessment for optimal outcomes.The findings suggest that the presence of risk factors may correlate with the challenge of achieving the high standard required for RCT.These insights contribute not only to improve education but also aid practitioners in treatment planning and referral decision-making within the field of endodontics.
6.Expert consensus on irrigation and intracanal medication in root canal therapy
Zou XIAOYING ; Zheng XIN ; Liang YUHONG ; Zhang CHENGFEI ; Fan BING ; Liang JINGPING ; Ling JUNQI ; Bian ZHUAN ; Yu QING ; Hou BENXIANG ; Chen ZHI ; Wei XI ; Qiu LIHONG ; Chen WENXIA ; He WENXI ; Xu XIN ; Meng LIUYAN ; Zhang CHEN ; Chen LIMING ; Deng SHULI ; Lei YAYAN ; Xie XIAOLI ; Wang XIAOYAN ; Yu JINHUA ; Zhao JIN ; Shen SONG ; Zhou XUEDONG ; Yue LIN
International Journal of Oral Science 2024;16(1):26-35
Chemical cleaning and disinfection are crucial steps for eliminating infection in root canal treatment.However,irrigant selection or irrigation procedures are far from clear.The vapor lock effect in the apical region has yet to be solved,impeding irrigation efficacy and resulting in residual infections and compromised treatment outcomes.Additionally,ambiguous clinical indications for root canal medication and non-standardized dressing protocols must be clarified.Inappropriate intracanal medication may present side effects and jeopardize the therapeutic outcomes.Indeed,clinicians have been aware of these concerns for years.Based on the current evidence of studies,this article reviews the properties of various irrigants and intracanal medicaments and elucidates their effectiveness and interactions.The evolution of different kinetic irrigation methods,their effects,limitations,the paradigm shift,current indications,and effective operational procedures regarding intracanal medication are also discussed.This expert consensus aims to establish the clinical operation guidelines for root canal irrigation and a position statement on intracanal medication,thus facilitating a better understanding of infection control,standardizing clinical practice,and ultimately improving the success of endodontic therapy.
7.Experts consensus on the procedure of dental operative microscope in endodontics and operative dentistry.
Bin LIU ; Xuedong ZHOU ; Lin YUE ; Benxiang HOU ; Qing YU ; Bing FAN ; Xi WEI ; Lihong QIU ; Zhengwei HUANG ; Wenwei XIA ; Zhe SUN ; Hanguo WANG ; Liuyan MENG ; Bin PENG ; Chen ZHANG ; Shuli DENG ; Zhaojie LU ; Deqin YANG ; Tiezhou HOU ; Qianzhou JIANG ; Xiaoli XIE ; Xuejun LIU ; Jiyao LI ; Zuhua WANG ; Haipeng LYU ; Ming XUE ; Jiuyu GE ; Yi DU ; Jin ZHAO ; Jingping LIANG
International Journal of Oral Science 2023;15(1):43-43
The dental operative microscope has been widely employed in the field of dentistry, particularly in endodontics and operative dentistry, resulting in significant advancements in the effectiveness of root canal therapy, endodontic surgery, and dental restoration. However, the improper use of this microscope continues to be common in clinical settings, primarily due to operators' insufficient understanding and proficiency in both the features and established operating procedures of this equipment. In October 2019, Professor Jingping Liang, Vice Chairman of the Society of Cariology and Endodontology, Chinese Stomatological Association, organized a consensus meeting with Chinese experts in endodontics and operative dentistry. The objective of this meeting was to establish a standard operation procedure for the dental operative microscope. Subsequently, a consensus was reached and officially issued. Over the span of about four years, the content of this consensus has been further developed and improved through practical experience.
Humans
;
Dentistry, Operative
;
Consensus
;
Endodontics
;
Root Canal Therapy
;
Dental Care
8.Development and evaluation of a novel method for rapid screening of Pichia pastoris strains capable of efficiently expressing recombinant proteins.
Yongan CHEN ; Qingyan YUAN ; Cheng LI ; Shuli LIANG ; Ying LIN
Chinese Journal of Biotechnology 2021;37(3):939-949
Pichia pastoris is one of the most widely used recombinant protein expression systems. In this study, a novel method for rapid screening of P. pastoris strains capable of efficiently expressing recombinant proteins was developed. Firstly, the ability to express recombinant proteins of the modified strain GS115-E in which a functional Sec63-EGFP (Enhanced green fluorescent protein) fusion protein replaced the endogenous endoplasmic reticulum transmembrane protein Sec63 was tested. Next, the plasmids carrying different copy numbers of phytase (phy) gene or xylanase (xyn) gene were transformed into GS115-E to obtain recombinant strains with different expression levels of phytase or xylanase, and the expression levels of EGFP and recombinant proteins in different strains were tested. Finally, a flow cytometer sorter was used to separate a mixture of cells with different phytase expression levels into sub-populations according to green fluorescence intensity. A good linear correlation was found between the fluorescence intensities of EGFP and the expression levels of the recombinant proteins in the recombinant strains (0.8<|R|<1). By using the flow cytometer, high-yielding P. pastoris cells were efficiently screened from a mixture of cells. The expression level of phytase of the selected high-fluorescence strains was 4.09 times higher than that of the low-fluorescence strains after 120 h of methanol induction. By detecting the EGFP fluorescence intensity instead of detecting the expression level and activity of the recombinant proteins in the recombinant strains, the method developed by the present study possesses the greatly improved performance of convenience and versatility in screening high-yielding P. pastoris strains. Combining the method with high-throughput screening instruments and technologies, such as flow cytometer and droplet microfluidics, the speed and throughput of this method will be further increased. This method will provide a simple and rapid approach for screening and obtaining P. pastoris with high abilities to express recombinant proteins.
6-Phytase/genetics*
;
Pichia/genetics*
;
Plasmids
;
Recombinant Proteins/genetics*
;
Saccharomycetales
9.Peer support experience of new graduated nurses during standardized training period: a qualitative study
Yiwen GAO ; Weiming XIAO ; Lin LIU ; Shuli MA ; Xiaoxi YANG ; Yuan YUAN
Chinese Journal of Practical Nursing 2021;37(33):2565-2570
Objective:To explore the peer support experience of newly graduated nurses during standardized training period.Methods:Using phenomenological qualitative research methods and purposive sampling, from April to December 2020, 32 new nurses who participated in the standardized training peer support program in the Affiliated Hospital of Yangzhou University were selected. Semi-structured interview was conducted and Claizzi content analysis method was used to analyze the data.Results:Peer support during the standardized training of new graduated nurses could be summarized into four major themes and eleven sub-themes. Theme 1: cognition and attitude (emotional security, adaptive guidance, recognition of the value of peer support, positive intention to support). Theme 2: peer support needs (department-related information needs; knowledge and skills experience needs; emotional communication needs; career growth support needs). Theme 3: peer support experience (adaptive behavior changes, cognitive and emotional changes, differences in perceived expectations of supporters and support effects).Conclusions:During the standardized training, we should attach importance to the important supporting role of peer support for new nurses. By building a peer support platform for new nurses and broadening experience exchange channels, we can enhance the positive experience of peer support, so as to promote the role adaptation and career growth of new nurses.
10. Clinical analysis of risk factors for severe patients with novel coronavirus pneumonia
Yun LING ; Yixiao LIN ; Zhiping QIAN ; Dan HUANG ; Dandan ZHANG ; Tao LI ; Min LIU ; Shuli SONG ; Jun WANG ; Yuyi ZHANG ; Shuibao XU ; Jun CHEN ; Jianliang ZHANG ; Tongyu ZHU ; Bijie HU ; Sheng WANG ; Enqiang MAO ; Lei ZHU ; Hongzhou LU
Chinese Journal of Infectious Diseases 2020;38(0):E023-E023
Objective To analyze the clinical features of patients with coronavirus disease 2019 (COVID-19) in Shanghai and to investigate the risk factors for disease progression to severe cases. Methods The clinical data of 292 adult patients with COVID-19 hospitalized in Shanghai Public Health Clinical Center from January 20, 2020 to February 10, 2020 were retrospectively analyzed, including 21 severe patients and 271 mild patients. The demographic characteristics, epidemiological history, history of underlying diseases and laboratory examinations were compared between the two groups. Measurement data were compared using t test or Mann-Whitney U test. The count data were compared using hi-square test. The binary logistic regression equation was used to analyze the risk factors for the progression of patients to severe cases. Results Among the 292 patients, 21 were severe cases with the rate of 7.2% (21/292). One patient died, and the mortality rate was 4.8% in severe patients. The severe patients aged (65.0±15.7) years old, 19 (90.5%) were male, 11 (52.4%) had underlying diseases, 7 (33.3%) had close relatives diagnosed with COVID-19. The mild patients aged (48.7±15.7) years old, 135 (49.8%) were male, 74 (27.3%) had underlying diseases, 36 (13.3%) had close relatives diagnosed with COVID-19. The differences between two groups were all significant statistically ( t =-4.730, χ 2 =12.930, 5.938 and 4.744, respectively, all P <0.05). Compared with the mild patients, the levels of absolute numbers of neutrophils, alanine aminotransferase, aspartate aminotransferase, lactate dehydrogenase, creatinine, serum cystatin C, C reactive protein (CRP), procalcitonin , D -dimer, pro-B-type natriuretic peptide (proBNP), serum myoglobin, creatine kinase (CK), creatine kinase isoenzyme (CK-MB), serum troponin I (cTnI) in severe patients were all significantly higher ( U =2 091.5, 1 928.0, 1 215.5, 729.0, 1 580.5, 1 375.5, 917.5, 789.5, 1 209.0, 1 434.0, 638.0, 964.5, 1 258.0 and 1 747.5, respectively, all P <0.05), while the levels of lymphocyte count, albumin, transferrin, CD3 + T lymphocyte count, CD8 + T lymphocyte count and CD4 + T lymphocyte count in severe patients were all significantly lower ( U =1 263.5, t =4.716, U =1 214.0, 962.0, 1 167.5 and 988.0, respectively, all P <0.05). Further logistic regression analysis showed that the albumin (odds ratio ( OR )=0.806, 95% CI 0.675-0.961), CRP ( OR =1.016, 95% CI 1.000-1.032), serum myoglobin ( OR =1.010, 95% CI 1.004-1.016), CD3 + T lymphocyte count ( OR =0.996, 95% CI 0.991-1.000) and CD8 + T lymphocyte count ( OR =1.006, 95% CI 1.001-1.010) at admission were independent risk factors for the progression of COVID-19 patients to severe illness (all P <0.05). Conclusions Severe cases of patients with COVID-19 in Shanghai are predominantly elderly men with underlying diseases. Albumin, CRP, serum myoglobin, CD3 + T lymphocyte count and CD8 + T lymphocyte count could be used as early warning indicators for severe cases, which deserve more clinical attention.

Result Analysis
Print
Save
E-mail