1.Value of three-dimensional inversion-recovery with real reconstruction sequence using an ultralong repetition time for endolymphatic hydrops
Menglong ZHAO ; Huaili JIANG ; Shujie ZHANG ; Zhuang LIU ; Kai LIU ; Di WU ; Xinsheng HUANG ; Mengsu ZENG
Chinese Journal of Clinical Medicine 2025;32(2):200-206
		                        		
		                        			
		                        			Objective To evaluate the value of an optimized three-dimensional inversion-recovery with real reconstruction (3D-real IR) sequence with a longer repetition time (TR, 16 000 ms) based on modulated flip angle technique in refocused imaging with extended echo train (MATRIX) in the endolymphatic hydrops (EH) imaging after intratympanic gadolinium (Gd) administration, and to compare it with a conventional 3D-real IR based on the turbo spin echo (TSE) sequence. Methods From July 2021 to November 2022, twenty-seven patients received both the conventional and optimized 3D-real IR sequences after bilateral intratympanic Gd administration. Images of the two sequences were qualitativly evaluated and compared. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and area ratio of endolymph against the total lymphatic space from the two sequences were measured and compared. Results 14(25.9%) ears with insufficient contrast for the EH diagnosis on the conventional sequence were clearly displayed on the optimized sequence. Image score, CNR and SNR of the optimized sequence were significantly higher than those of the conventional sequence (P < 0.001). The scanning time of two sequences was similar. The area ratio of endolymph against the total lymphatic space in the cochlear was significantly higher on the conventional 3D-real IR than that on the optimized 3D-real IR (P < 0.001); there was no statistical difference in the vestibule between the two sequences. Conclusions Compared with conventional sequence, optimized 3D-real IR sequence with a longer TR may be better for evaluation of EH after intratympanic Gd administration.
		                        		
		                        		
		                        		
		                        	
2.Application of three-dimensional fluid-attenuated inversion recovery sequence using artificial intelligence-assisted compressed sensing technique in intravenous gadolinium contrast-enhanced magnetic resonance imaging of inner ear
Kai LIU ; Jian WANG ; Huaili JIANG ; Shujie ZHANG ; Di WU ; Xinsheng HUANG ; Mengsu ZENG ; Menglong ZHAO
Chinese Journal of Clinical Medicine 2025;32(2):212-217
		                        		
		                        			
		                        			Objective To investigate the value of artificial intelligence-assisted compressed sensing (ACS) technology for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear using three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence. Methods The patients received gadolinium contrast-enhanced magnetic resonance imaging using ACS and united compressed sensing (uCS) 3D-FLAIR at Zhongshan Hospital, Fudan University from January to November 2024 were prospectively enrolled. The repetition time was 16 000 ms, and acquisition time was 6 min 40 s and 10 min 24 s in ACS 3D-FLAIR and uCS 3D-FLAIR, respectively. The images on the two sequences were evaluated independently by two radiologists. The image quality of the two sequences was subjectively evaluated and compared. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between the two sequences. The grading consistencies using two sequences and between the two doctors were analyzed. Results There was no statistically difference in subjective score of image quality between the two sequences. SNR and CNR of the ACS 3D-FLAIR sequence were significantly higher than those of the uCS 3D-FLAIR sequence (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops were 0.942 and 0.888 using two sequences (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops using the ACS 3D-FLAIR sequence between the two doctors were 0.784 and 0.831, respectively (P<0.001); the kappa values of grades of cochlear and vestibular endolymphatic hydrops using uCS 3D-FLAIR sequence between the two doctors were 0.725 and 0.756, respectively (P<0.001). Conclusions ACS 3D-FLAIR could provide higher SNR and CNR than uCS 3D-FLAIR, and is more suitable for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear; the endolymphatic hydrops grades using ACS 3D-FLAIR is similar to use uCS 3D-FLAIR.
		                        		
		                        		
		                        		
		                        	
3.Progress of the effect of hydroxyacyl-coenzyme A dehydrogenase in cancer development and its mechanism
Guojia WU ; Shujie ZHAI ; Xiao SUN ; Yiran HUANG ; Yongmei LI ; Li SUN
Basic & Clinical Medicine 2024;44(1):119-123
		                        		
		                        			
		                        			A close relationship between fatty acid metabolism and cancer development is well-established.The hydroxyacyl-coenzyme a dehydrogenase(HADH),a key enzyme in fatty acid beta-oxidation,has recently been identified as an anti-oncogenic factor in various cancers and an oncogenic factor in conditions like acute myeloid leukemia.In cancer cells,HADH not only directly catalyzes fatty acid beta-oxidation but also indirectly influences multiple signaling pathways such as PPAR,TNF-α,JAK-STAT3,PI3K/Akt,IFN-γ,MAPK,and non-canonical Wnt signaling pathways,affecting cancer cell proliferation and migration.HADH shows promise as a potential tumor biomarker for diagnosis,treatment,and prognosis in different cancer types,holding significant clinical value.
		                        		
		                        		
		                        		
		                        	
4.Clinical and Pathological Characteristics of Extrapleural Solitary Fibrous Tumor
Ying LIU ; Shujie SONG ; Lin WU
Journal of Kunming Medical University 2024;45(1):100-106
		                        		
		                        			
		                        			Objective To investigate the clinical and pathological characteristics of the extrapleural solitary fibrous tumor and the relevant differential diagnosis.Methods HE and immunohistochemical staining were performed on 26 samples of isolated fibrous tumors outside the pleura,and a comprehensive analysis was conducted based on the clinical and imaging data.Results The histological morphology of isolated fibrous tumors was diverse,with typical cases showing the irregular arrangement of oval or spindle shaped cells.In the stroma,thick collagen bands,antler like blood vessels,and peritubular transparent degeneration could be seen.The immunohistochemical staining demonstrated that the positive rates of STAT-6、CD34、Bcl-2、CD99、SMA were 96.2% 、92.3% 、92.3% 、76.9% and 26.9%,respectively.Conclusion SFT commonly occurs in the pleura and can also occur in other areas.Its histological characteristics and immunohistochemical phenotype help to clarify the diagnosis.However,when it occurs in uncommon anatomical sites,it is necessary to carefully and meticulously distinguish and comprehensively judge the clinical prognosis of key diseases that need to be distinguished or excluded..
		                        		
		                        		
		                        		
		                        	
5.Alteration of cognitive function in overweight and obese adolescents and its relationship with serum FGF21 levels
Rui HAN ; Qian WU ; Dan LIU ; Di CHENG ; Ying ZHANG ; Jiacheng NI ; Piao KANG ; Anran CHEN ; Shujie YU ; Qichen FANG ; Huating LI
Journal of Shanghai Jiaotong University(Medical Science) 2024;44(1):87-97
		                        		
		                        			
		                        			Objective·To evaluate the changes in cognitive function in overweight and obese adolescents,and explore the association between cognitive function and fibroblast growth factor 21(FGF21).Methods·A total of 175 adolescents from a senior high school in Shanghai were divided into normal weight group(n=50),overweight group(n=50)and obese group(n=75)based on their body mass index(BMI).General information,anthropometric data and laboratory testing indicators of the adolescents were collected and compared.The cognitive function of the three groups of adolescents was assessed by using the accuracy(ACC)and reaction time of Flanker task and n-back task.Enzyme-linked immunosorbent assay(ELISA)was used to detect the serum FGF21 level of the three groups of adolescents.Partial correlation analysis and multiple linear regression model were used to evaluate the correlation between cognitive task performance and anthropometric data and laboratory testing indicators.Results·Compared with the normal weight group,systolic blood pressure,diastolic blood pressure,and the levels of fasting plasma glucose,glycosylated hemoglobin and triacylglycerol in the obese group were higher(all P<0.05).Under congruent or incongruent stimulus conditions in the Flanker task,there was no significant difference in ACC between any two groups;compared with the normal weight and overweight groups,the reaction time of the adolescents in the obese group was prolonged(all P<0.05).In the n-back task,there were no significant differences in ACC between any two groups,while the obese group had longer reaction time in the 1-back and 2-back tasks compared to the normal weight and overweight groups(all P<0.05).Compared with the normal weight group,serum FGF21 levels of the adolescents in the obese group were higher(P=0.000).Partial correlation analysis showed that the reaction time of the adolescents in Flanker and n-back tasks was correlated with their BMI,body fat mass,waist circumference,waist-to-hip ratio and FGF21 level(all P<0.05).Multiple linear regression analysis further confirmed that BMI was associated with prolonged reaction time in cognitive-related behavioral tasks in the adolescents(all P<0.05),and FGF21 level was associated with ACC in the 2-back task(P=0.000)and reaction time in the incongruent stimulus condition(P=0.048).Conclusion·Overweight and obese adolescents have cognitive impairments,and BMI and serum FGF21 levels are associated with changes in their cognitive function.
		                        		
		                        		
		                        		
		                        	
6.Application of computer-aided design modified 3D printing model in video-assisted thoracoscopic sublobular resection for early lung cancer: A retrospective cohort study
Xinyu ZHANG ; Linqian LI ; Haoran LI ; Qiang GUO ; Hongli YAN ; Jinghua LI ; Shujie CHENG ; Hefei LI ; Ke ZHANG ; Jihong YANG ; Jianguo WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(09):1266-1273
		                        		
		                        			
		                        			Objective  To compare the effect of three-dimensional visual (3DV) model, three-dimensional printing (3DP) model and computer-aided design (CAD) modified 3DP model in video-assisted thoracoscopic surgery (VATS) sublobular resection. Methods The clinical data of patients who underwent VATS sublobular resection in the Affiliated Hospital of Hebei University from November 2021 to August 2022 were retrospectively analyzed. The patients were divided into 3 groups including a 3DV group, a 3DP group and a CAD-3DP group according to the tools used. The perioperative indexes and subjective evaluation of operators, patients and their families were compared. Results A total of 22 patients were included. There were 5 males and 17 females aged 32-77 (56.95±12.50) years. There were 9 patients in the 3DV group, 6 patients in the 3DP group, and 7 patients in the CAD-3DP group. There was no statistical difference in the operation time, intraoperative blood loss, drainage volume, hospital stay time or postoperative complications among the groups (P>0.05). Based on the subjective evaluations of 4 surgeons, the CAD-3DP group was better than the 3DV group in the preoperative planning efficiency (P=0.025), intuitiveness (P=0.045) and doctor-patient communication difficulty (P=0.034); the CAD-3DP group was also better than the 3DP group in the overall satisfaction (P=0.023), preoperative planning difficulty (P=0.046) and efficiency (P=0.014). Based on the subjective evaluations of patients and their families, the CAD-3DP group was better than the 3DP group in helping understand the vessel around the tumor (P=0.016), surgical procedure (P=0.020), procedure selection (P=0.029), and overall satisfaction (P=0.048); the CAD-3DP group was better than the 3DV group in helping understand the tumor size (P=0.038). Conclusion CAD-modified 3DP model has certain advantages in pre-planning, intraoperative navigation and doctor-patient communication in the VATS sublobectomy.
		                        		
		                        		
		                        		
		                        	
7.Design and experimental study of molecular sieve oxygen generating device at high altitude
Yi LI ; Xiaofeng LIU ; Shujie CUI ; Bo WANG ; Ping LI ; Yanan WU ; Wei ZHANG ; Yanru HAN
Military Medical Sciences 2024;48(11):848-852
		                        		
		                        			
		                        			Objective To develop a pressure swing adsorption oxygen generating device that is workable at altitudes of 0 to 7000 meters.Methods The three-bed molecular sieve oxygen production process was adopted.The switching time of air circuit solenoid valve and the rotation speed of the compression pump were taken as controllable variables.The performance of the oxygen generating device was tested in a normal atmospheric environment and a low-pressure environment corresponding to altitudes of 0 to 7000 meters.The optimal values of controllable oxygen generating parameters corresponding to 10 low-pressure environments(89.9,79.7,69.7,65.0,62.0,57.7,53.8,47.6,43.0,41.0 kPa)were obtained.Results The oxygen concentration could reach 94%,oxygen flow rate was 9 L/min and oxygen outlet pressure stood at 44 kPa in a normal atmospheric environment(altitude 416 meters),compared with 94%,6.3 L/min and 30 kPa in a low-pressure environment of 41 kPa(altitude 7000 meters).Conclusion The oxygen generating device can meet the oxygen needs of two persons within the altitude range of 0 to 7000 meters.
		                        		
		                        		
		                        		
		                        	
8.Long TR three-dimensional inversion recovery sequence with real reconstruction(3D real IR)for quantifying inner ear endolymphatic hydrops
Di WU ; Menglong ZHAO ; Mengsu ZENG ; Kai LIU ; Shujie ZHANG ; Wei SUN
Chinese Journal of Medical Imaging Technology 2024;40(8):1174-1178
		                        		
		                        			
		                        			Objective To observe the value of long TR three-dimensional inversion recovery sequence with real reconstruction(3D real IR)for quantifying inner ear endolymphatic hydrops(EH).Methods Totally 46 Ménière's disease(MD)patients and 21 healthy volunteers were prospectively enrolled.MR scanning for inner ear based on 3D real IR and 3D fluid attenuated inversion recovery(3D FLAIR)sequence 4-6 h after administration of contrast agents were performed.The imaging qualities were scored and compared between groups.The endolymphatic space area and the membranous labyrinth area of cochlea and vestibule,as well as endolymph/membranous labyrinth area percentage were calculated,the present or not of EH and the grade of EH were evaluated.EH inner ears of MD patients were enrolled in EH group,while inner ears of healthy volunteers were taken as controls(control group).The endolymphatic space area,membranous labyrinth area and endolymph/membranous labyrinth area percentage of cochlea and vestibule were compared between groups.The receiver operating characteristic(ROC)curve was drawn to calculate the diagnostic efficacy of the above indexes.Results Cochlear and/or vestibular EH were detected in 56 ears,including cochlear EH in 52 ears and vestibular EH in 45 ears among 46 MD patients(EH group),but not in 42 ears in control group.The subjective quality scores of 3D real IR images were higher than those of 3D-FLAIR(both P<0.05).Quantitative analysis based on 3D real IR images revealed that,compared with control group,significantly larger endolymph areas and endolymph/membranous labyrinth area percentages in both cochlea and vestibule were found in EH group(all P<0.001).The area under the curve(AUC)of cochlear or vestibular endolymph/membranous labyrinth area percentage for identifying inner ear EH was 0.999 and 0.985,respectively.Taken 13.64%and 24.13%as the critical value of cochlear or vestibular endolymph,the specificity was 100%and 92.86%,respectively,and the sensitivity was 96.43%and 96.43%,respectively.Conclusion MR long TR 3D real IR was helpful to quantifying inner ear EH.
		                        		
		                        		
		                        		
		                        	
9.Clinical guidelines for the diagnosis and treatment of osteoporotic thoracolumbar vertebral fracture with kyphotic deformity in the elderly (version 2024)
Jian CHEN ; Qingqing LI ; Jun GU ; Zhiyi HU ; Shujie ZHAO ; Zhenfei HUANG ; Tao JIANG ; Wei ZHOU ; Xiaojian CAO ; Yongxin REN ; Weihua CAI ; Lipeng YU ; Tao SUI ; Qian WANG ; Pengyu TANG ; Mengyuan WU ; Weihu MA ; Xuhua LU ; Hongjian LIU ; Zhongmin ZHANG ; Xiaozhong ZHOU ; Baorong HE ; Kainan LI ; Tengbo YU ; Xiaodong GUO ; Yongxiang WANG ; Yong HAI ; Jiangang SHI ; Baoshan XU ; Weishi LI ; Jinglong YAN ; Guangzhi NING ; Yongfei GUO ; Zhijun QIAO ; Feng ZHANG ; Fubing WANG ; Fuyang CHEN ; Yan JIA ; Xiaohua ZHOU ; Yuhui PENG ; Jin FAN ; Guoyong YIN
Chinese Journal of Trauma 2024;40(11):961-973
		                        		
		                        			
		                        			The incidence of osteoporotic thoracolumbar vertebral fracture (OTLVF) in the elderly is gradually increasing. The kyphotic deformity caused by various factors has become an important characteristic of OTLVF and has received increasing attention. Its clinical manifestations include pain, delayed nerve damage, sagittal imbalance, etc. Currently, the definition and diagnosis of OTLVF with kyphotic deformity in the elderly are still unclear. Although there are many treatment options, they are controversial. Existing guidelines or consensuses pay little attention to this type of fracture with kyphotic deformity. To this end, the Lumbar Education Working Group of the Spine Branch of the Chinese Medicine Education Association and Editorial Committee of Chinese Journal of Trauma organized the experts in the relevant fields to jointly develop Clinical guidelines for the diagnosis and treatment of osteoporotic thoracolumbar vertebral fractures with kyphotic deformity in the elderly ( version 2024), based on evidence-based medical advancements and the principles of scientificity, practicality, and advanced nature, which provided 18 recommendations to standardize the clinical diagnosis and treatment.
		                        		
		                        		
		                        		
		                        	
10.Comparison of safety and efficacy of robot assistance versus conventional freehand methods in the upper cervical spine surgery
Jian CHEN ; Qingqing LI ; Shujie ZHAO ; Mengyuan WU ; Zihan ZHOU ; Jiayun LIU ; Peng GAO ; Jin FAN ; Xiaojian CAO ; Yongxin REN ; Weihua CAI ; Lipeng YU ; Guoyong YIN ; Wei ZHOU
Chinese Journal of Orthopaedics 2024;44(8):578-586
		                        		
		                        			
		                        			Objective:To evaluate the impact of orthopedic robotic assistance and conventional freehand methods on surgical strategies, the safety of pedicle screw placement, and clinical efficacy in patients with upper cervical spine diseases.Methods:From January 2017 to March 2023, a total of 63 cases with upper cervical spine disease, were divided into two groups based on the screw placement technique: the robot-assisted pedicle screw placement (RA) group (41 cases) and the conventional freehand pedicle screw placement (CF) group (22 cases), were retrospectively included. These patients in the RA and CF groups underwent two types of posterior cervical surgery, including occipitocervical fusion (9 cases and 8 cases) and fixation and fusion of atlantoaxial and distal vertebrae (32 cases and 14 cases). The outcome parameters, including the disease course, surgical time, intraoperative blood loss, fluoroscopy frequency, radiation dose, hospital stay, treatment costs, complications, the rate of the pedicle screw placement, accuracy of upper cervical pedicle screw placement, and the risk factors that possibly affected the accuracy were recorded and analyzed. Postoperative follow-up was conducted for at least 6 months, and the efficacy of patients was assessed using imaging parameters, ASIS classification, VAS, and JOA scores.Results:Both groups had no screw-related complications and no spinal cord or vertebral artery injuries. In the RA group, the pedicle screw placement rates for the patients with occipitocervical fusion, and fixation and fusion of atlantoaxial and distal vertebrae were 100% (48/48) and 89.6% (138/154), respectively, far exceeding the placement rate in the CF group 42.9% (18/42) and 78.3% (54/69) (χ 2=37.403, P<0.001; χ 2=5.128, P=0.024). The fluoroscopic exposure dose and operation time of the two types of surgical patients in the RA group were both higher than those in the CF group ( P<0.05). Compared with the CF group, the accuracy of C 1 screws in the RA group increased from 42% (11/26) to 80% (51/64), with statistical significance (χ 2=13.342, P=0.004); while the accuracy of C 2 screws improved from 77% (33/43) to 88% (63/72) with no statistical difference (χ 2=2.863, P=0.413). Non-parametric correlation analysis found a significant correlation between the accuracy of C 1 and C 2 pedicle screw placement and the order of guide wire insertion in the RA group ( r=0.580, P<0.001; r=0.369, P=0.001). Postoperatively, both groups showed significant differences in cervicomedullary angle (CMA), Chamberlain angle (CL), McGregor angle, Boogard angle, Bull angle, clivus-canal angle (CCA), occipitocervical (C 0-C 2) angle, posterior occipitocervical angle (POCA), C 2-C 7 angle, and anterior atlantodental interval (ADI) ( P<0.05). The ASIA classification improved to varying degrees for both groups postoperatively, but there were no statistically significant differences between preoperative, postoperative, and last follow-up evaluations. VAS and JOA scores significantly improved for both groups postoperatively and at the last follow-up ( P<0.05). Conclusion:Both orthopedic robotic-assisted and conventional freehand pedicle screw placement techniques achieved satisfactory therapeutic effects in the treatment of upper cervical spine diseases. The orthopedic robot can effectively ensure the accuracy of upper cervical pedicle screw placement, the increase placement rate of pedicle screws in the upper cervical spine, and reduce fluoroscopy exposure. However, it is necessary to avoid the vertebral displacement caused by the priority insertion of the guide needle, which may affect the accuracy of subsequent planning.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail