1.Concept, design and clinical application of minimally invasive liver transplantation through laparoscopic combined upper midline incision
Shuhong YI ; Hui TANG ; Kaining ZENG ; Xiao FENG ; Binsheng FU ; Qing YANG ; Jia YAO ; Yang YANG ; Guihua CHEN
Organ Transplantation 2025;16(1):67-73
Objective To explore the technical process and clinical application of laparoscopic combined upper midline incision minimally invasive liver transplantation. Methods A retrospective analysis was conducted on 30 cases of laparoscopic combined upper midline incision minimally invasive liver transplantation. The cases were divided into cirrhosis group (15 cases) and liver failure group (15 cases) based on the primary disease. The surgical and postoperative conditions of the two groups were compared. Results All patients successfully underwent laparoscopic "clockwise" liver resection, with no cases of passive conversion to open surgery or intolerance to pneumoperitoneum. In 6 cases, the right lobe was relatively large, and the right hepatic ligaments could not be completely mobilized. One case required an additional reverse "L" incision during open surgery. All patients successfully completed the liver transplantation, with no major intraoperative bleeding, cardiovascular events, or other occurrences in the 30 patients. The model for end-stage liver disease (MELD) score in the cirrhosis group was lower than that in the liver failure group (P<0.001). There were no statistically significant differences between the two groups in terms of age, surgical time, blood loss, anhepatic phase, or cold ischemia time (all P>0.05). During the perioperative period, there was 1 case of hepatic artery embolism, 1 case of portal vein anastomotic stenosis, no complications of hepatic vein and inferior vena cava, and 3 cases of biliary anastomotic stenosis, all of which occurred in the liver failure group. Conclusions In strictly selected cases, the minimally invasive liver transplantation technique combining laparoscopic hepatectomy with upper midline incision for graft implantation has the advantages of smaller incisions, less bleeding, relatively easier operation, and faster postoperative recovery, which is worthy of clinical promotion and application.
2.Application of middle hepatic vein splitting and reconstruction technique in split liver transplantation from low-age donor livers
Hui TANG ; Binsheng FU ; Qing YANG ; Jia YAO ; Kaining ZENG ; Xiao FENG ; Shuhong YI ; Yang YANG
Organ Transplantation 2025;16(3):453-459
Objective To explore the feasibility and clinical experience of the middle hepatic vein splitting-reconstruction technique in split liver transplantation from low-age donor livers. Methods A retrospective analysis was conducted on the cases of two low-age donor livers that underwent middle hepatic vein splitting-reconstruction, which were transplanted into four child recipients at the Liver Transplantation Center of the Third Affiliated Hospital of Sun Yat-sen University from January 2017 to July 2023. The surgical and postoperative conditions were summarized and analyzed. Results Donor 1 was a 6-year-old and 4-month-old girl with a body weight of 21 kg, and the obtained donor liver weighed 496 g. After splitting, the left and right liver weights were 201 g and 280 g, and transplanted into a 9-month-old boy weighing 6.5 kg and a 9-month-old boy weighing 7.5 kg, respectively. The graft to recipient weight ratio (GRWR) was 3.09% and 3.73%, respectively. Donor 2 was a 5-year-old and 8-month-old boy with a body weight of 19 kg, and the donor liver weighed 673 g. After splitting, the left and right liver weights were 230 g and 400 g, and transplanted into a 13-month-old girl weighing 9.5 kg and a 15-month-old boy weighing 12 kg. The GRWR was 2.42% and 3.33%, respectively. Both donor livers were split ex vivo, with the middle hepatic vein being completely split in the middle and reconstructed using allogeneic iliac vein and iliac artery vascular patches. According to GRWR, none of the 4 transplant livers were reduced in volume. Among the 4 recipients, one died due to postoperative portal vein thrombosis and non-function of the transplant liver, while the other three cases recovered smoothly without early or late complications. Regular follow-up was conducted until July 31, 2023, and liver function recovered well. Conclusions Under the premise of detailed assessment of the donor liver and meticulous intraoperative operation, as well as matching with suitable child recipients, low-age donor livers may be selected for splitting. The complete splitting and reconstruction of the middle hepatic vein in the middle may effectively ensure the adequate venous return of the left and right liver and provide sufficient functional liver volume.
3.Diagnosis and treatment of the portal vein complications for children undergoing spilt liver transplantation
Kaining ZENG ; Qing YANG ; Jia YAO ; Hui TANG ; Binsheng FU ; Xiao FENG ; Haijin LYU ; Huimin YI ; Shuhong YI ; Yang YANG
Organ Transplantation 2024;15(1):63-69
Objective To investigate the diagnosis and treatment strategy of the portal vein complications in children undergoing split liver transplantation. Methods The clinical data of 88 pediatric recipients who underwent split liver transplantation were retrospectively analyzed. Intraoperative anastomosis at the bifurcating site of the portal vein or donor iliac vein bypass anastomosis was performed depending on the internal diameter and development of the recipient's portal vein. A normalized portal venous blood stream monitoring was performed during the perioperative stage. After operation, heparin sodium was used to bridge warfarin for anticoagulation therapy. After portal vein stenosis or thrombosis was identified with enhanced CT or portography, managements including embolectomy, systemic anticoagulation, interventional thrombus removal, balloon dilatation and/or stenting were performed. Results Among the 88 recipients, a total of 10 children were diagnosed with portal vein complications, of which 4 cases were diagnosed with portal vein stenosis at 1 d, 2 months, 8 months, and 11 months after surgery, and 6 cases were diagnosed with portal vein thrombosis at intraoperative, 2 d, 3 d (n=2), 6 d, and 11 months after surgery, respectively. One patient with portal vein stenosis and one patient with portal vein thrombosis died perioperatively. The fatality related to portal vein complications was 2% (2/88). Of the remaining 8 patients, 1 underwent systemic anticoagulation, 2 underwent portal venous embolectomy, 1 underwent interventional balloon dilatation, and 4 underwent interventional balloon dilatation plus stenting. No portal venous related symptoms were detected during postoperative long term follow up, and the retested portal venous blood stream parameters were normal. Conclusions The normalized intra- and post-operative portal venous blood stream monitoring is a useful tool for the early detection of portal vein complications, the early utilization of useful managements such as intraoperative portal venous embolectomy, interventional balloon dilatation and stenting may effectively treat the portal vein complications, thus minimizing the portal vein complication related graft loss and recipient death.
4.Golgi Transport 1A Promotes Cell Proliferation and Metastasis of Papillary Thyroid Carcinoma
Shuhong KE ; Zhujun XU ; Yang ZHOU ; Chenghong ZHENG
Journal of Sun Yat-sen University(Medical Sciences) 2024;45(1):69-75
ObjectiveTo investigate the expression level of Golgi transport 1A (GOLT1A) in thyroid carcinoma and its effects on the proliferation, migration, invasion, and epithelial-mesenchymal transition (EMT) of thyroid carcinoma cells. MethodsThe expression of GOLT1A in thyroid carcinoma was analyzed online by tumor immune estimation resource (TIMER), the University of Alabama at Birmingham cancer data analysis portal (UALCAN), gene expression profiling interactive analysis 2 (GEPIA2). The expression level of GOLT1A in thyroid carcinoma cells was detected by real-time fluorescence quantitative polymerase chain reaction (RTFQ-PCR) and western blot. Cell counting kit-8 (CCK-8) assay, colony formation assay, and transwell assay were used to detect the effects of GOLT1A expression on the proliferation, migration, and invasion of thyroid carcinoma cells. Western blot assay was used to detect the effect of GOLT1A on the expression of EMT-related genes including E-cadherin, vimentin, and N-cadherin. ResultsThe online analysis of GEPIA2, TIMER, and UALCAN showed that the expression of GOLT1A was higher in thyroid carcinoma than in normal tissues, and the expression of GOLT1A in thyroid carcinoma cells was significantly higher than in normal control cells. Knockdown of GOLT1A inhibited TPC1 cell proliferation, migration, and invasion. The expression of E-cadherin increased and the expressions of N-cadherin and vimentin decreased in GOLT1A knockdown TPC1 cells. Overexpression of GOLT1A promoted BCPAP cell proliferation, migration, and invasion. The expression of E-cadherin decreased and the expressions of N-cadherin and vimentin increased in GOLT1A overexpression BCPAP cells. ConclusionGOLT1A is highly expressed in thyroid carcinoma and can promote the proliferation, migration, and invasion of thyroid carcinoma cells.
5.Anatomic classification and reconstruction of right intrahepatic bile duct in the donor liver of split liver trans-plantation
Jinming WEI ; Binsheng FU ; Qing YANG ; Tong ZHANG ; Xiao FENG ; Kaining ZENG ; Jia YAO ; Hui TANG ; Guihua CHEN ; Yang YANG ; Shuhong YI
Chinese Journal of Digestive Surgery 2024;23(2):272-279
Objective:To investigate the anatomic classification and reconstruction of right intrahepatic bile duct in the donor liver of split liver transplantation (SLT).Methods:The retrospective and descriptive study was constructed. The clinical data of 85 patients who underwent SLT in the Third Affiliated Hospital of Sun Yat-sen University from July 2014 to January 2022 were collected. There were 65 males and 20 females, aged 45(range, 1-82)years. Observation indicators: (1) surgical conditions; (2) anatomy of right intrahepatic bile duct; (3) bile duct reconstruction; (4) postoperative biliary complications; (5) follow-up. Measurement data with normal distribution were represented as Mean± SD, and measurement data with skewed distribution were represented as M(range) or M( Q1, Q3).Count data were described as absolute numbers or percentages, and comparison between groups was conducted using the chi-square test or Fisher exact probability. Results:(1) Surgical conditions. Of the 85 donor livers, 11 donor livers were split between the left and right hemilivers, and 74 donor livers were split between the classic right trilobe and left lateral lobe. The cold ischemia time of 85 donor livers was 291(273, 354)minutes, and the operation time, anhepatic phase time and volume of intraoperative blood transfusion of 85 recipients were (497±97)minutes, 51(40, 80)minutes and 8(7, 12)U. (2) Anatomy of right intrahepatic bile duct. Of the 85 donor livers, there were 47 donor livers with classic bile duct anatomical model (type 1), of the ratio as 55.3%(47/85), and 38 donor livers with anatomical variants, of the ratio as 44.7%(38/85). Of the 38 donor livers with anatomical variants, 7 donor livers were type 2, 16 donor livers were type 3a, 2 donor livers were type 3b, 2 donor livers were type 3c, 1 donor liver was type 4, 3 donor livers were type 5a, 4 donor livers were type 5b, 3 donor livers were type 6. For bile duct splitting patterns of the 85 donor livers, 84 donor livers were split with the main trunk of common hepatic duct preserving in the right hemiliver or right trilobe, and 1 donor liver were treated with complete left and right hemiliver splitting to preserve the main trunk of the common hepatic duct in the left hemiliver and the right hemiliver in the right hepatic duct (type 1 bile duct anatomical model). There were 84 donor livers with only one bile duct opening, and 1 donor liver with two bile duct openings (type 3c bile duct anatomical model). (3) Bile duct reconstruction. Of the 85 recipients, there were 69 recipients with common bile duct end-to-end anastomosis to common bile duct of donor liver (38 donor livers with type 1 bile duct anatomical model, 5 donor livers with type 2 bile duct anatomical model, 14 donor livers with type 3a bile duct anatomical model, 2 donor livers with type 3b bile duct anatomical model, 1 donor liver with type 4 bile duct anatomical model, 3 donor livers with type 5a bile duct anatomical model, 4 donor livers with type 5b bile duct anatomical model, 2 donor livers with type 6 bile duct anatomical model), 11 recipients with jejunum anastomosis to common bile duct of donor liver (7 donor livers with type 1 bile duct anatomical model, 2 donor livers with type 2 bile duct anatomical model, 1 donor liver with type 3c bile duct anatomical model, 1 donor liver with type 6 bile duct anatomical model), 3 recipients with jejunum anastomosis to common hepatic duct of donor liver (1 donor liver with type 1 bile duct anatomical model, 2 donor livers with type 3a bile duct anatomical model), 1 recipient with jejunum anastomosis to right hepatic duct of donor liver (type 1 bile duct anatomical model), 1 recipient with common hepatic duct end-to-end anastomosis to right posterior branch of donor liver combined with jejunum of the recipient Roux-en-y anastomosis to common hepatic duct of donor liver (type 3c bile duct anatomical model). (4) Postoperative biliary complications. Of the 85 recipients, 6 cases had postoperative biliary complications, with an incidence of 7.1% (6/85). Of the 6 recipients with postoperative biliary complications, there were 5 recipients with donor liver with type 1 bile duct anatomical model, including 3 cases undergoing postoperative biliary stricture with biliary leakage and 2 cases undergoing postoperative biliary anastomotic stricture, 1 recipient with donor liver with type 3b bile duct anatomical model and undergoing postoperative biliary anastomotic stricture and bile leakage in the liver section. Cases with biliary complications were 5 in the 47 recipients with donor liver with classic bile duct anatomical model and 1 in the 38 recipients with donor liver with anato-mical variants, showing no significant difference between them ( P>0.05). (5) Follow-up. There were 83 recipients receiving followed up for 52(12,96)months. During the follow-up period, 2 recipients died due to non-biliary complication factors (1 donor liver with type 1 bile duct anatomical model and 1 donor liver with 3a bile duct anatomical model). Conclusion:The anatomical classification of right intrahepatic bile duct of donor liver in SLT is mainly classical bile duct anatomical model, and the bile duct reconstruction scheme is mainly common bile duct of donor liver end-to-end anasto-mosis to common bile duct of recipient.
6.Construction and evaluation of an indicator system for nursing human resource efficiency in integrated medical and elderly care institutions using Data Envelopment Analysis
Mingxin HE ; Yanyan LI ; Yalou YANG ; Hongrui ZHU ; Shuhong GAO ; Shiming ZHOU ; Hua ZHANG ; Xiangdong ZHOU
Chinese Journal of Health Management 2024;18(2):99-106
Objective:To construct an evaluation indicator system for the efficiency of nursing human resources in integrated medical and elderly care institutions using Data Envelopment Analysis (DEA) and subsequently evaluate its effectiveness.Methods:This cross-sectional survey utilized literature review and investigative methods to initially establish a library of evaluation indicators for nursing human resource efficiency. The Delphi method was employed in two rounds of consultations with 17 experts from various fields, including nursing management, elderly care institution management, integrated medical and elderly care institution management, health economics management, and public health. The reliability of the indicator system was assessed based on factors such as expert enthusiasm, authority, concentration of opinions, and coordination. Adjustments, modifications, and improvements were made to the indicators based on expert opinions to establish the final indicator system. From August to December 2022, the DEA model was applied to evaluate the efficiency of 12 integrated medical and elderly care institutions in Haikou city based on this indicator system.Results:The constructed evaluation indicator system comprised 68 items divided into three levels: 9 primary indicators, 19 secondary indicators, and 40 tertiary indicators. The positive coefficients of the two rounds of expert consultations were 100% and 94.1%, with authority coefficients of 0.88 and 0.92, Kendall harmony coefficients of 0.471 and 0.348, and mean coefficients of variation of 0.16 and 0.12 ( P<0.001). DEA evaluation results for the 12 integrated medical and elderly care institutions showed that 5 were DEA effective institutions with comprehensive efficiency (OE), technical efficiency (TE), and scale efficiency (SE) values all equal to 1.000, while 7 were non-DEA effective institutions, including 4 with SE <1.000 but TE=1.000 and 3 with both SE and TE<1.000. Conclusions:The constructed evaluation indicator system demonstrates high enthusiasm, authority coefficients, and coordination in expert consultations, indicating high acceptability and comprehensive content with distinct levels and strong specialty characteristics. The DEA model′s evaluation results objectively and effectively reflect the efficiency of nursing human resources in integrated medical and elderly care institutions, demonstrating practical utility.
7.Mechanism of action and clinical research progress of iguratimod in connective tissue diseases
Xiaorong YANG ; Shuhong ZHOU ; Lijiang GUO ; Ying CHEN ; Yingying JI ; Lijie XU
China Pharmacy 2024;35(5):629-634
As a new type of immunosuppressant,iguratimod can mediate the anti-inflammatory signaling pathway by inhibiting the proliferation of inflammatory cells and reducing the release of inflammatory cytokines, and play the role of anti-inflammatory. It can affect the proliferation of immune cells and the expression of immune factors,reduce the production and deposition of immune complexes in the body,and play the role of immune regulation. It can regulate bone metabolism by mediating signaling pathways such as Wnt/β-catenin,Toll-like receptor 4/nuclear factor-κB and osteoprotegerin/nuclear factor-κB receptor activating factor ligand, and play a role in bone protection. It can inhibit pulmonary fibrosis by inhibiting the expression of transforming growth factor β1/ Smad2/3 signaling pathway,tumor necrosis factor-α,interleukin-1,interleukin-6,matrix metalloproteinase-9 and other inflammatory cytokines in lung tissue,and inhibiting the expression of collagen and fibronectin. Its efficacy and safety have been confirmed in the clinical application of rheumatoid arthritis and primary Sjogren syndrome and included in the diagnosis and treatment of the disease. It has also shown good efficacy in the clinical application of other connective tissue diseases such as systemic lupus erythematosus and ankylosing spondylitis,and no obvious safety risks have been found.
8.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.

Result Analysis
Print
Save
E-mail