1.Newborn screening, clinical features and genetic analysis for Citrin deficiency in Henan province
Xinyun ZHU ; Yizhuo XU ; Jie ZHANG ; Xiaole LI ; Jingwen HE ; Chenlu JIA ; Shubo LYU ; Suna LIU ; Yanbo GAO ; Kun MA ; Yunjia OUYANG ; Yihui REN ; Dehua ZHAO
Chinese Journal of Medical Genetics 2024;41(4):461-466
		                        		
		                        			
		                        			Objective:To explore the prevalence, clinical features, genetic characteristics and prognosis of Citrin deficiency in Henan province of China.Methods:A total of 986 565 neonates screened by tandem mass spectrometry at the Third Affiliated Hospital of Zhengzhou University from January 2013 to December 2021 were retrospectively analyzed. Analysis of SLC25A13 gene variants and parental verification were carried out for neonates suspected for Citrin deficiency by next-generation sequencing. The clinical, biochemical and genetic characteristics of Citrin deficiency patients were integrated to guide the diet treatment and follow up the growth and development. Paired- t test was used to compare the amino acid levels in the peripheral blood samples before and after the treatment. Results:Nine cases of Citrin deficiency were diagnosed among the 986 565 neonates. Specific elevation of citrulline was observed in all of the 9 cases. Six variants were detected by genetic sequencing, among which c. 852_855delTATG, c. 615+ 5G>A, c. 550C>T and IVS16ins3kb were known pathogenic variants, whilst c. 1111_1112delAT and c. 837T>A were unreported previously. The detection rate for c. 852_855delTATG was the highest (61.6%, 11/18), followed by IVS16ins3kb (16.7%, 3/18). The clinical symptoms of all patients were relieved after the treatment, and the blood amino acid profile and biochemical parameters were significantly improved by gradually falling within the normal range. By June 2022, all patients had shown a good prognosis.Conclusion:The prevalence of Citrin deficiency among neonates from Henan Province by tandem mass spectrometry is 1/109 618, and the carrier rate for the pathogenic variants of the SLC25A13 gene was 1/166. The c. 852_855delTATG may be a hot spot variant among the patients. Discovery of the novel variants has enriched the mutational spectrum of the SLC25A13 gene. Above results have provided a basis for the early diagnosis, treatment, prognosis and genetic counseling for the affected families.
		                        		
		                        		
		                        		
		                        	
2.In vitro bench testing using patient-specific 3D models for percutaneous pulmonary valve implantation with Venus P-valve
Yu HAN ; Zehua SHAO ; Zirui SUN ; Yan HAN ; Hongdang XU ; Shubo SONG ; Xiangbin PAN ; De Jaegere Peter P. T. ; Taibing FAN ; Gejun ZHANG
Chinese Medical Journal 2024;137(8):990-996
		                        		
		                        			
		                        			Background::Due to the wide variety of morphology, size, and dynamics, selecting an optimal valve size and location poses great difficulty in percutaneous pulmonary valve implantation (PPVI). This study aimed to report our experience with in vitro bench testing using patient-specific three-dimensional (3D)-printed models for planning PPVI with the Venus P-valve. Methods::Patient-specific 3D soft models were generated using PolyJet printing with a compliant synthetic material in 15 patients scheduled to undergo PPVI between July 2018 and July 2020 in Central China Fuwai Hospital of Zhengzhou University.Results::3D model bench testing altered treatment strategy in all patients (100%). One patient was referred for surgery because testing revealed that even the largest Venus P-valve would not anchor properly. In the remaining 14 patients, valve size and/or implantation location was altered to avoid valve migration and/or compression coronary artery. In four patients, it was decided to change the point anchoring because of inverted cone-shaped right ventricular outflow tract (RVOT) ( n = 2) or risk of compression coronary artery ( n = 2). Concerning sizing, we found that an oversize of 2-5 mm suffices. Anchoring of the valve was dictated by the flaring of the in- and outflow portion in the pulmonary artery. PPVI was successful in all 14 patients (absence of valve migration, no coronary compression, and none-to-mild residual pulmonary regurgitation [PR]). The diameter of the Venus P-valve in the 3D simulation group was significantly smaller than that of the conventional planning group (36 [2] vs. 32 [4], Z = -3.77, P <0.001). Conclusions::In vitro testing indicated no need to oversize the Venus P-valve to the degree recommended by the balloon-sizing technique, as 2-5 mm sufficed.
		                        		
		                        		
		                        		
		                        	
3.Adjustable "paper clip" techniques suturing the dorsal vein complex in radical prostatectomy
Yang CHEN ; Fangxing ZHANG ; Tianyu LI ; Chengyang LI ; Deyun LIU ; Haibiao YAN ; Zhanbin YANG ; Hua MI ; Linjian MO ; Naikai LIAO ; Shubo YANG ; Jiwen CHENG
Journal of Modern Urology 2023;28(8):707-712
		                        		
		                        			
		                        			【Objective】 To investigate the efficacy of the adjustable "paper clip" techniques in the suture of dorsal vein complex (DVC) and retention of urethral function in robot-assisted laparoscopic radical prostatectomy (RALRP). 【Methods】 A total of 30 cases of prostate cancer treated with RALRP were enrolled, all of which used the adjustable "paper clip" techniques. During operation, the DVC was sewed with barbed suture, and then a reverse suture was made through two sides of the prostatic ligaments. A Hem-o-lock was used to fasten the suture, which would be flexible to control the degree of tightness for the ligature. Perioperative and follow-up data of urinary continence and symptoms were collected and analyzed. 【Results】 All operations were successful. The estimated blood loss was (123.3±80.7) mL, 53.6% patients recovered continence in 1 month, and the continence rate increased to 92.9% and 96.3% at month 3 and 6. 92.9 of patients had no risk of incontinence 3 months after surgery. 【Conclusion】 The adjustable "paper clip" techniques have advantages in reducing blood loss, maintaining clear surgical field, preserving urethral function, and improving urinary continence.
		                        		
		                        		
		                        		
		                        	
4.Robotic urologic surgery using the KangDuo-Surgical Robot-01 system: A single-center prospective analysis.
Shengwei XIONG ; Shubo FAN ; Silu CHEN ; Xiang WANG ; Guanpeng HAN ; Zhihua LI ; Wei ZUO ; Zhenyu LI ; Kunlin YANG ; Zhongyuan ZHANG ; Cheng SHEN ; Liqun ZHOU ; Xuesong LI
Chinese Medical Journal 2023;136(24):2960-2966
		                        		
		                        			BACKGROUND:
		                        			The KangDuo-Surgical Robot-01 (KD-SR-01) system is a new surgical robot recently developed in China. The aim of this study was to present our single-center experience and mid-term outcomes of urological procedures using the KD-SR-01 system.
		                        		
		                        			METHODS:
		                        			From August 2020 to April 2023, consecutive urologic procedures were performed at Peking University First Hospital using the KD-SR-01 system. The clinical features, perioperative data, and follow-up outcomes were prospectively collected and analyzed.
		                        		
		                        			RESULTS:
		                        			A total of 110 consecutive patients were recruited. Among these patients, 28 underwent partial nephrectomy (PN), 41 underwent urinary tract reconstruction (26 underwent pyeloplasty, 3 underwent ureteral reconstruction and 12 underwent ureterovesical reimplantation [UR]), and 41 underwent radical prostatectomy (RP). The median operative time for PN was 112.5 min, 157.0 min for pyeloplasty, 151.0 min for ureteral reconstruction, 142.5 min for UR, and 138.0 min for RP. The median intraoperative blood loss was 10 mL for PN, 10 mL for pyeloplasty, 30 mL for ureteral reconstruction, 20 mL for UR, and 50 mL for RP. All procedures were successfully completed without conversion, and there were no major complications in any patient. The median warm ischemia time of PN was 17.3 min, and positive surgical margin was not noted in any patient. The overall positive surgical margin rate of RP was 39% (16/41), and no biochemical recurrence was observed in any RP patient during the median follow-up of 11.0 months. The surgical success rates of pyeloplasty and UR were 96% (25/26) and 92% (11/12) during the median follow-up of 29.5 months and 11.5 months, respectively.
		                        		
		                        			CONCLUSION
		                        			The KD-SR-01 system appears feasible, safe, and effective for most urological procedures, based on our single-center experience.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Robotic Surgical Procedures/methods*
		                        			;
		                        		
		                        			Robotics
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Ureter/surgery*
		                        			;
		                        		
		                        			Urologic Surgical Procedures/methods*
		                        			;
		                        		
		                        			Laparoscopy/methods*
		                        			
		                        		
		                        	
5.Efficacy and safety of LY01005 versus goserelin implant in Chinese patients with prostate cancer: A multicenter, randomized, open-label, phase III, non-inferiority trial.
Chengyuan GU ; Zengjun WANG ; Tianxin LIN ; Zhiyu LIU ; Weiqing HAN ; Xuhui ZHANG ; Chao LIANG ; Hao LIU ; Yang YU ; Zhenzhou XU ; Shuang LIU ; Jingen WANG ; Linghua JIA ; Xin YAO ; Wenfeng LIAO ; Cheng FU ; Zhaohui TAN ; Guohua HE ; Guoxi ZHU ; Rui FAN ; Wenzeng YANG ; Xin CHEN ; Zhizhong LIU ; Liqiang ZHONG ; Benkang SHI ; Degang DING ; Shubo CHEN ; Junli WEI ; Xudong YAO ; Ming CHEN ; Zhanpeng LU ; Qun XIE ; Zhiquan HU ; Yinhuai WANG ; Hongqian GUO ; Tiwu FAN ; Zhaozhao LIANG ; Peng CHEN ; Wei WANG ; Tao XU ; Chunsheng LI ; Jinchun XING ; Hong LIAO ; Dalin HE ; Zhibin WU ; Jiandi YU ; Zhongwen FENG ; Mengxiang YANG ; Qifeng DOU ; Quan ZENG ; Yuanwei LI ; Xin GOU ; Guangchen ZHOU ; Xiaofeng WANG ; Rujian ZHU ; Zhonghua ZHANG ; Bo ZHANG ; Wanlong TAN ; Xueling QU ; Hongliang SUN ; Tianyi GAN ; Dingwei YE
Chinese Medical Journal 2023;136(10):1207-1215
		                        		
		                        			BACKGROUND:
		                        			LY01005 (Goserelin acetate sustained-release microsphere injection) is a modified gonadotropin-releasing hormone (GnRH) agonist injected monthly. This phase III trial study aimed to evaluated the efficacy and safety of LY01005 in Chinese patients with prostate cancer.
		                        		
		                        			METHODS:
		                        			We conducted a randomized controlled, open-label, non-inferiority trial across 49 sites in China. This study included 290 patients with prostate cancer who received either LY01005 or goserelin implants every 28 days for three injections. The primary efficacy endpoints were the percentage of patients with testosterone suppression ≤50 ng/dL at day 29 and the cumulative probability of testosterone ≤50 ng/dL from day 29 to 85. Non-inferiority was prespecified at a margin of -10%. Secondary endpoints included significant castration (≤20 ng/dL), testosterone surge within 72 h following repeated dosing, and changes in luteinizing hormone, follicle-stimulating hormone, and prostate specific antigen levels.
		                        		
		                        			RESULTS:
		                        			On day 29, in the LY01005 and goserelin implant groups, testosterone concentrations fell below medical-castration levels in 99.3% (142/143) and 100% (140/140) of patients, respectively, with a difference of -0.7% (95% confidence interval [CI], -3.9% to 2.0%) between the two groups. The cumulative probabilities of maintaining castration from days 29 to 85 were 99.3% and 97.8%, respectively, with a between-group difference of 1.5% (95% CI, -1.3% to 4.4%). Both results met the criterion for non-inferiority. Secondary endpoints were similar between groups. Both treatments were well-tolerated. LY01005 was associated with fewer injection-site reactions than the goserelin implant (0% vs . 1.4% [2/145]).
		                        		
		                        			CONCLUSION:
		                        			LY01005 is as effective as goserelin implants in reducing testosterone to castration levels, with a similar safety profile.
		                        		
		                        			TRIAL REGISTRATION
		                        			ClinicalTrials.gov, NCT04563936.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Antineoplastic Agents, Hormonal/therapeutic use*
		                        			;
		                        		
		                        			East Asian People
		                        			;
		                        		
		                        			Gonadotropin-Releasing Hormone/agonists*
		                        			;
		                        		
		                        			Goserelin/therapeutic use*
		                        			;
		                        		
		                        			Prostate-Specific Antigen
		                        			;
		                        		
		                        			Prostatic Neoplasms/drug therapy*
		                        			;
		                        		
		                        			Testosterone
		                        			
		                        		
		                        	
6.Medium-term follow-up of percutaneous pulmonary valve implantation using the Venus-P self-expanding valve
Shubo SONG ; Taibing FAN ; Yu HAN ; Weijie LIANG ; Bin LI ; Kaiyuan WU ; Lin LIU ; Dong LIANG ; Gejun ZHANG ; Xiangbin PAN
Chinese Journal of Applied Clinical Pediatrics 2022;37(2):98-102
		                        		
		                        			
		                        			Objective:To evaluate the medium-term clinical and hemodynamic outcomes of percutaneous pulmonary valve implantation (PPVI) using a domestic Venus-P self-expanding valve in the treatment of severe pulmonary regurgitation after Tetralogy of Fallot (TOF).Methods:Retrospective study.From December 2017 to December 2020, 13 TOF patients with (17.8±4.7) years old and (50.2±12.3) kg underwent PPVI using the Venus-P self-expanding valve in the Department of Children′s Heart Center, Zhengzhou University People′s Hospital were recruited.The mean valve size was (31.9±3.1) mm.All patients received the transannular patch surgery and developed severe pulmonary regurgitation.After PPVI, 13 patients were followed up for at least 12 months.The operation-related complications, improvement of valve and heart function and the durability and reintervention of the Venus-P self-expanding valve were analyzed.The right ventricular end-diastolic volume index (RVEDVi) before and after operation was compared by the paired t-test, and the New York Heart Association (NYHA) class was compared by the paired Wilcoxon signed rank sum test. Results:PPVI was successfully performed in all 13 patients without death.At 6 months post-PPVI, cardiac magnetic resonance imaging findings showed that RVEDVi was significantly reduced[(145.7±9.6) mL/m 2vs.(100.2±12.2) mL/m 2, P<0.05], and the NYHA class was significantly improved ( P<0.05). One patient presented moderate pulmonary valve regurgitation at 12 months postoperatively.No vegetation was found on echocardiography, and blood culture was negative in this case.Six patients did not have postoperative pulmonary valve regurgitation, and the remaining presented mild or less pulmonary regurgitation.One patient had sudden ventricular tachycardia on the 6 th day postoperatively, which was converted to sinus rhythm after synchronous electrocardiography.Only one case underwent appendectomy 7 months after operation due to acute appendicitis, and the remaining did not require valve-related reintervention after implantation.During the follow-up for (22.8±8.0) months, no patients had perivalve leakage, stent migration and rupture.Complications like embolization and coronary artery compression were not reported. Conclusions:PPVI using the Venus-P self-expanding valve is safe and effective in patients with severe pulmonary valve regurgitation after TOF surgery, showing an acceptable medium-term follow-up outcome.Studies with a large sample size and long follow-up period are still needed to validate our findings.
		                        		
		                        		
		                        		
		                        	
7.The prognostic value of eukaryotic cell translation initiation complex 4F in HCC patients
Renzhe Qian ; Dachen Zhou ; Ziheng Lu ; Liang He ; Shubo Pan ; Bin Zhang
Acta Universitatis Medicinalis Anhui 2022;57(11):1712-1717
		                        		
		                        			Objective    :
		                        			To  study the  correlation  between eukaryotic translation initiation complex 4f  ( EIF4F)  and  clinical prognosis of patients with hepatocellular carcinoma  (HCC) .
		                        		
		                        			Methods    :
		                        			By following up the clinical data of 743 HCC patients in the specimen bank,94 HCC tissue specimens with complete follow-up information were select- ed,and the clinical data were collected.The paired tissue specimens were made into tissue chip for immunohisto- chemical staining.Image J was used to analyze the optical density value of tissue chip staining,and R4. 0. 5  soft- ware was used to conduct nonparametric test analysis,draw KM curve,Cox regression analysis,and Nomogram sta- tistical analysis on experimental data and follow-up data. 
		                        		
		                        			Results    :
		                        			Phosphorylation of 4EBP1 was significantly acti- vated in HCC tissues  (P<0. 001) ,and  the  activation Phosphorylation of 4EBP1 was associated with the clinical prognosis of HCC patients,P = 0. 038.
		                        		
		                        			Conclusion    
		                        			The activation of 4EBP1 phosphorylation in tumor tissue pre- dicts shorter overall survival time in HCC patients.
		                        		
		                        		
		                        		
		                        	
8.Newborn screening, gene variation analysis and follow-up study of very long chain acyl CoA dehydrogenase deficiency
Xiaole LI ; Shubo LYU ; Linlin ZHANG ; Xinyun ZHU ; Yuan TIAN ; Min NI ; Suna LIU ; Yizhuo XU ; Jie ZHANG ; Jun WANG ; Dehua ZHAO
Chinese Journal of Applied Clinical Pediatrics 2021;36(23):1815-1819
		                        		
		                        			
		                        			Objective:To investigate the prevalence, gene variation and prognosis of very long chain acyl CoA dehydrogenase deficiency (VLCADD) in newborns in Henan Province.Methods:From January 2013 to December 2019, 867 103 newborns were investigated for VLCADD by tandem mass spectrometry.Children who diagnosed as VLCADD and their families were subjected to next-generation sequencing and Sanger sequencing.Clinical data, biochemical changes and gene variation characteristics of the confirmed cases of VLCADD were analyzed.Dietary guidance was given, and their growth and development were followed up.Results:Six neonates were diagnosed as VLCADD, and the prevalence of VLCADD in the Henan Province was 1/144 517.A total of 11 mutations in the ACADVL gene were found, including 5 new variants c. 692-2_692-1delAG, c.753-23_753-22del, c.960delG, c.1361A>G, and c. 1955C>T.The newborns were given a high-carbohydrate, low-fat diet, and followed up for 8-56 months.Except for two deaths, all patients had a good outcome. Conclusions:The prevalence of neonatal VLCADD in Henan Province is 1/144 517.This results has enriched the ACADVL gene mutation spectrum and provided an important basis for the screening and diagnosis of VLCADD.
		                        		
		                        		
		                        		
		                        	
9.Initial clinical application of domestic endoscopic surgical robot system for partial nephrectomy
Xuesong LI ; Shubo FAN ; Shengwei XIONG ; Xiaofei DAI ; Kunlin YANG ; Zhihua LI ; Chang MENG ; Jie WANG ; Zheng ZHANG ; Lin CAI ; Cuijian ZHANG ; Zhongyuan ZHANG ; Wei YU ; Cheng SHEN ; Gang WANG ; Liqun ZHOU
Chinese Journal of Urology 2021;42(5):375-380
		                        		
		                        			
		                        			Objective:To evaluate the safety and effectiveness of Kangduo endoscopic surgical robot system for partial nephrectomy.Methods:Consecutive patients with stage T 1 renal tumor meeting the inclusion criteria from the Department of Urology, Peking University First Hospital from December 2020 to February 2021 were prospectively enrolled. All patients underwent partial nephrectomy with the Kangduo endoscopic surgical robot system after signing the informed consent. Clinical data including preoperative, perioperative and postoperative pathology and follow-up were collected. Results:Among the 26 patients, there were 16 males and 10 females, with a median age of 53(33-74) years, and a median body mass index of 25.99(20.90-32.91) kg/m 2. There were 12 cases of left kidney tumor and 14 cases of right kidney tumor. The median tumor diameter was 2.2(1.0-3.5) cm. The median time of warm ischemia was 17.7(7.1-29.2) minutes, and all of them were less than 30 minutes. The median docking time was 4.7(2.3-9.9) minutes, and the median time of robotic arm operation was 65.0 (37.0-155.0) minutes. The median National Aeronautics and Space Administration Task Load Index (NASA-TLX) score was 5.3 (2.0-28.0), and no instrument-related adverse events occurred intraoperatively. The median postoperative hospital stay was 4 (4-5) days. All tumor margins were negative on pathologic reports. No Clavien Ⅱ stage operative complications occurred in all patients during perioperative period and 1 month after the surgery. Conclusions:The partial nephrectomy using the kangduo endoscopic surgical robot system were completed successfully, and no instrument-related adverse events and complications occurred, showing that this surgical system used for partial nephrectomy is safe and effective.
		                        		
		                        		
		                        		
		                        	
10.Roles of multidisciplinary team in diagnosis and treatment of suspected cases of COVID-19.
Shubo DING ; Shi'an YU ; Haijun CHEN ; Dehe ZHANG ; Yejin XU ; Dan ZHU ; Kun CHENG
Journal of Zhejiang University. Medical sciences 2020;49(2):209-214
		                        		
		                        			OBJECTIVE:
		                        			To analyze the roles of multidisciplinary team (MDT) in the diagnosis and treatment of suspected cases of coronavirus disease 2019 (COVID-19).
		                        		
		                        			METHODS:
		                        			The clinical data of 48 patients with suspected COVID-19 admitted in Jinhua Municipal Central Hospital from January 21, 2020 to March 20, 2020 were retrospectively analyzed.
		                        		
		                        			RESULTS:
		                        			In the 48 suspected cases, 18 were diagnosed with COVID-19, and 30 were excluded. Each of the confirmed cases were discussed among MDT for 2 to 12 times with an average of (4.7±3.2) times; while for non-COVID-19 patients were discussed for 2 to 4 times with an average of (2.3±0.6) times. With the guidance of MDT, one COVID-19 patient was transferred to designated provincial hospital after effective treatment; one patient complicated with acute cholecystitis underwent gallbladder puncture and drainage; and COVID-19 was excluded in a highly suspected patient after alveolar lavage fluid examination. Except one transferred patient, all 17 confirmed COVID-19 patients were cured and discharged. There was no cross-infection occurred in suspected patients during the hospitalization. There were no deaths and no medical staff infections.
		                        		
		                        			CONCLUSIONS
		                        			The efficiency of diagnosis and treatment for suspected COVID-19 patients can be improved with MDT, particularly for complicated cases.
		                        		
		                        		
		                        		
		                        			Betacoronavirus
		                        			;
		                        		
		                        			isolation & purification
		                        			;
		                        		
		                        			China
		                        			;
		                        		
		                        			Coronavirus Infections
		                        			;
		                        		
		                        			diagnosis
		                        			;
		                        		
		                        			therapy
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Interdisciplinary Communication
		                        			;
		                        		
		                        			Pandemics
		                        			;
		                        		
		                        			Patient Care Team
		                        			;
		                        		
		                        			standards
		                        			;
		                        		
		                        			Pneumonia, Viral
		                        			;
		                        		
		                        			diagnosis
		                        			;
		                        		
		                        			therapy
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Treatment Outcome
		                        			
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail