1.Methacrylated dermal extracellular matrix hydrogel promotes repair of abdominal wall defects
Zhongyu LIU ; Wenya LI ; Yonghong FAN ; Shuang LYU ; Juan PEI ; Yaqin CHEN ; Beiyu LIU ; Hongyu SUN
Chinese Journal of Tissue Engineering Research 2025;29(10):2074-2082
		                        		
		                        			
		                        			BACKGROUND:Synthetic polymers,such as polypropylene and polyester,used for the treatment of abdominal wall defects not only lack biodegradability and bioactivity but also fail to meet the demands of complex and irregular wounds.Therefore,finding bioactive materials with low immunogenicity and good histocompatibility has become a hot spot in the repair of abdominal wall defects. OBJECTIVE:To prepare methacryloyl modified dermal extracellular matrix hydrogel and explore its potential application in abdominal wall defect. METHODS:(1)The porcine dermis was acellular with 0.25%trypsin and 1%Triton X-100 in turn to obtain the dermal extracellular matrix.After pepsin digestion and methacrylic anhydride modification,the methacrylated dermal extracellular matrix hydrogel was formed by photocrosslinking.The microscopic morphology of the hydrogel was observed by scanning electron microscope,and its rheological properties,swelling properties and other physical and chemical properties were tested.(2)Mice fibroblasts(L929)were inoculated into methacrylated dermal extracellular matrix hydrogel to detect the cell compatibility.(3)Totally 12 SD rats were randomly divided into two groups(n=6)to create abdominal wall defect model with peritoneum preserved.The defect site of the polypropylene group was filled with polypropylene material,and the hydrogel group was filled with methacrylated dermal extracellular matrix hydrogel.The wound skin of both groups was covered with polypropylene material.The wound healing was observed and histological analysis was carried out. RESULTS AND CONCLUSION:(1)Enzymatic hydrolysis had a good decellularization effect on porcine dermis after decellularization,and the original glycosaminoglycans and collagen were well retained.Scanning electron microscope observation revealed that the dermal extracellular matrix hydrogel presented loose and porous structure.The aperture was between 70 and 120 μm.The swelling ratio was(16.88±3.24)%and the water absorption was(94.24±1.11)%.The rheological property test showed that the methacrylated dermal extracellular matrix hydrogel was stable and had shear thinning characteristics,with injectability.(2)CCK-8 assay and live/dead staining showed that methacrylated dermal extracellular matrix hydrogel had good cell compatibility.(3)The results of animal experiments showed that the skin wound healing rate of the experimental group was higher than that of the control group at 7,10,and 14 days after operation(P<0.05).Hematoxylin-eosin and Masson staining of skin and muscle tissue exhibited that compared with the polypropylene group,the skin wound epithelialization,hair follicle formation,collagen fiber arrangement,and neovascularization were better in the hydrogel group 14 days after surgery.The skin wound new tissue structure was similar to the normal tissue at 28 days after surgery,and scar hyperplasia was less.A small amount of muscle regeneration was observed on day 28 after operation.(4)The results show that the methacrylated dermal extracellular matrix hydrogel can promote wound skin healing and muscle tissue regeneration in rats with abdominal wall defect.
		                        		
		                        		
		                        		
		                        	
2.Research progress in radiation-induced skin injury
Jinlong WEI ; Qin ZHAO ; Jincai LYU ; Zining TAN ; Xuanzhong WANG ; Qifeng WANG ; Jinbo YUE ; Pei YANG ; Wencheng ZHANG ; Shuang LI ; Ye ZHANG ; Xin JIANG ; Bing WANG
Chinese Journal of Radiation Oncology 2024;33(11):1024-1032
		                        		
		                        			
		                        			Radiotherapy is one of the main treatment methods for malignant tumors, which can cause the radiation damage to normal tissues. Radiation-induced skin injury (RISI) is one of the main adverse reactions caused by radiotherapy. The main clinical manifestations of RISI are dermatitis, ulcer, erosion and necrosis, which seriously affect the quality of life and treatment effect of tumor radiotherapy patients, and even affect the overall survival of patients. The pathological mechanism of RISI is still unclear. Some studies have shown that inflammation and oxidative stress are the main causes of RISI. RISI can be divided into acute and chronic RISI according to the different onset time, and different treatment strategies can be formulated according to the severity of the injury. In this article, clinical manifestations, classification, pathogenesis, prevention and treatment of RISI are comprehensively summarized.
		                        		
		                        		
		                        		
		                        	
3.Application of different transbronchoscopic biopsies in the diagnosis of senile central lung cancer
Pei ZHAN ; Yu ZHANG ; Fei-Yan LAN ; Wei YANG ; Xiao-Shuang LIAO ; Zhi-Qiang TIAN
Journal of Regional Anatomy and Operative Surgery 2024;33(12):1081-1084
		                        		
		                        			
		                        			Objective To study the application value of different transbronchial biopsies in the diagnosis of central lung cancer in elderly patients.Methods The clinical data of 97 elderly patients with central lung cancer diagnosed by pathology from June 2020 to June 2023 in the 923rd Hospital of Chinese People's Liberation Army Joint Logistic Support Force were retrospectively analyzed.According to the different initial transbronchial biopsy methods,the patients were divided into the endobronchial biopsy(EBB)group(n=51)and the conventional transbronchial needle aspiration(cTBNA)group(n=46).The histopathological results were statistically analyzed,and the first biopsy positive rates of EBB and cTBNA in the diagnosis of senile central lung cancer were calculated and compared.At the same time,the differences of biopsy tolerance and complications between the two groups were evaluated.Results The squamous cell carcinoma proportions in both groups were over 50%.There was no significant difference in the first biopsy positive rate between the two groups(P>0.05).The incidence of temporary retreat of the scope due to subjective tolerance in the EBB group was higher than that in the cTBNA group,and the difference was statistically significant(P<0.05).There was a statistically significant difference in the incidence of intraoperative complications of different grades between the two groups(P<0.001).Among them,the incidence of grade 2 and above complications during surgery in the EBB group was significantly higher than that in the cTBNA group(P<0.001).Conclusion For elderly patients with central lung cancer,the success rate of the first biopsy of EBB and cTBNA is roughly equivalent,but the incidence of postoperative complications of the latter is significantly lower than that of the former.cTBNA can be used as the first biopsy method for this population.
		                        		
		                        		
		                        		
		                        	
4.Safety and efficacy of domestically produced novel bioabsorbable vascular scaff old in the treatment of complex coronary artery lesions for 3 years
Deng-Shuang ZHOU ; Qiong YOU ; Hai-Liang MO ; Zi-Jun WU ; Yu-Biao LIN ; Lu-Jun CHEN ; Jun-Yu FAN ; Yong-Jian LIN ; Rui-Sheng ZHANG ; Pei-Shan WAN ; Wei-Guo ZHOU ; Keng WU
Chinese Journal of Interventional Cardiology 2024;32(9):509-515
		                        		
		                        			
		                        			Objective To investigate the safety and efficacy of novel bioabsorbable vascular scaffold(BVS)in the treatment of patients with complex coronary artery disease.Methods This was a retrospective,matched,single-center observational study.45 patients with coronary atherosclerotic cardiopathy received BVS treatment in the cardiovascular medicine department Department of the Affiliated Hospital of Guangdong Medical University from June 2020 to June 2021(BVS),and 45 patients treated with drug-eluting stents(DES)group were selected according to matching study requirements during the same period.Baseline,surgical,and follow-up data were compared between the two groups to evaluate safety and efficacy.The main measures of safety were:surgical time,intraoperative adverse events,etc.,and the end point of efficacy was target lesion failure(TLF),including cardiac death,target vessel myocardial infarction,and ischa-driven target lesion revascularization.Results A total of 90 patients were enrolled in this study,all of whom were followed up for at least 3 years.There were 20 cases of bifurcation lesions and 25 cases of diffuse long lesions in the two groups,and 50 cases of imaging were reviewed among the 90 patients.The proportion of stable coronary heart disease,history of diabetes,history of hypertension,history of smoking,pre-dilated balloon pressure and postoperative diastolic blood pressure in BVS group was higher than that in DES group,and the proportion of family history was lower than that in DES group(all P<0.05).There were no statistically significant differences in the rates of cardiac death,target vessel myocardial infarction,and ischemia-driven revascularization of target lesions between the two groups(all P>0.05).Binary Logistic regression model analysis showed that the diameter stenosis ratio of target lesions was an independent risk factor for intrastent restenosis(OR 2.786,95%CI 1.096-7.081,P=0.031).Conclusions Compared with traditional DES,BVS implantation has consistent safety and efficacy in the treatment of complex coronary artery disease within 3 years.The diameter stenosis ratio of target lesions was an independent risk factor for intrastent restenosis.
		                        		
		                        		
		                        		
		                        	
5.Effect of Recombinant Human Thrombopoietin on Platelet Reconstitution after Autologous Peripheral Blood Stem Cell Transplantation in Patients with Multiple Myeloma
Yan XIE ; Ling-Zhi YAN ; Tao YOU ; Xiao-Lan SHI ; Shuang YAN ; Ying-Ying ZHAI ; Jing-Jing SHANG ; Zhi YAN ; Hong-Ying YOU ; Qing-Qing WANG ; De-Pei WU ; Cheng-Cheng FU
Journal of Experimental Hematology 2024;32(2):505-511
		                        		
		                        			
		                        			Objective:To analyze the effect of recombinant human thrombopoietin(rhTPO)on platelet(PLT)reconstitution after autologous peripheral blood stem cell transplantation(APBSCT)in patients with multiple myeloma(MM).Methods:The clinical data of 147 MM patients who were diagnosed in the First Affiliated Hospital of Soochow University and received APBSCT as the first-line therapy were retrospectively analyzed.According to whether rhTPO was used during APBSCT,the patients were divided into rhTPO group(80 cases)and control group(67 cases).The time of PLT engraftment,blood product infusion requirements,the proportion of patients with PLT recovery to ≥ 50 × 109/L and ≥ 100 × 109/L at+14 days and+100 days after transplantation,and adverse reactions including the incidence of bleeding were compared between the two groups.Results:There were no significant differences between the two groups in sex,age,M protein type,PLT count at the initial diagnosis,median duration of induction therapy before APBSCT,and number of CD34+cells reinfused(all P>0.05).The median time of PLT engraftment in the rhTPO group was 10(6-14)days,which was shorter than 11(8-23)days in the control group(P<0.001).The median PLT transfusion requirement in the rhTPO group during APBSCT was 15(0-50)U,which was less than 20(0-80)U in the control group(P=0.001).At+14 days after transplantation,the proportions of patients with PLT 2 50 × 109/L in the rhTPO group and the control group were 66.3%and 52.2%,while the proportions of patients with PLT ≥ 100 × 109/L were 23.8%and 11.9%,respectively,with no significant differences(all P>0.05).At+100 days after transplantation,the proportion of patients with PLT ≥ 50 × 109/L in rhTPO group and control group was 96.3%and 89.6%,respectively(P>0.05),but the proportion of patients with PLT ≥ 100 × 109/L in rhTPO group was higher than that in control group(75.0%vs 55.2%,P=0.012).There was no difference in the overall incidence of bleeding events in different locations during period of low PLT level of patients between the two groups.In rhTPO group,the rhTPO administration was well tolerated,and the incidences of abnormal liver and kidney function and infection were similar to those in the control group.Conclusion:When MM patients undergo first-line APBSCT,subcutaneous injection of rhTPO can shorten the time of platelet engraftment,reduce the transfusion volume of blood products,and be well tolerated,moreover,more patients have achieve a high level of PLT recovery after transplantation,which is very important for ensuring the safety of APBSCT and maintenance therapy.
		                        		
		                        		
		                        		
		                        	
6.Study on fatigue vibration evaluation of ultrasonic knife tip based on Q factor
Ke-Sheng WANG ; Ze-Kai LI ; Pei LIU ; Jing-Sheng SUN ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(6):17-22
		                        		
		                        			
		                        			Objective To propose a Q factor-based fatigue vibration evaluation method of the ultrasonic knife tip.Methods Firstly,an ultrasonic cutter fatigue testing table was established to realize repeated cutting,which was composed of a power supply module,a three-axis moving module,an ultrasonic cutter clamping module and a control module.Secondly,10 ultrasonic knives of some brand underwent fatigue testing with the table,during which non-contact measurement of the ultrasonic knife tip vibration was carried out and the Q factors were calculated at the five periods of the fatigue test,including the periods before cutting,after 500 times of cutting,after 1 000 times of cutting,after 2 000 times of cutting and after 3 000 times of cutting.Finally,the average cutting speed and burst pressure for coagulated vessels were computed at each period to validata the effectiveness of the method proposed.Results It's indicated that Q factor could effectively reflect the fatigue degradation of the ultrasonic knife tip,while the average cutting speed and burst pressure for coagulated vessels were difficult to efficiently evaluate the fatigue degradation level of the ultrasonic knife tip due to the uncertainty factors in the measurement process.Conclusion The proposed Q factor-based evaluation method can directly evaluate fatigue vibration of the ultrasonic knife tip in an accurate and quantitative manner.[Chinese Medical Equipment Journal,2024,45(6):17-22]
		                        		
		                        		
		                        		
		                        	
7.Accurate quantitative evaluation of MRI scanning noise based on laser vibrometry technology
Ke-Sheng WANG ; Pei-Jia XU ; Pei LIU ; Jing-Sheng SUN ; Ze-Kai LI ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(10):20-24
		                        		
		                        			
		                        			Objective To carry out accurate quantative evaluation of MRI scanning noise based on laser vibrometry technology.Methods Skull and spine MRI was performed with mute and conventional sequences.A laser vibrometry device was used to sample the surface vibration noise at the outer edge of the inspection hole of MRI system according to GB/T 16539-1996 Acoustics—Determination of sound power levels of noise sources using vibration velocity—Measurement for seal machinery,and the indicators of sound power level,sound pressure level and perceived noise level obtained by the three calculation methods(LPN1,LPN2 and LPN3)were analyzed with some dedicated MRI noise analysis software.Results The peak sound pressure levels for conventional and mute sequences of skull scanning were 81 and 63 dB(A),respectively,and mute sequence reduced the noise level significantly;the peak sound pressure levels for conventional and mute sequences of spine scanning were 79 and 75 dB(A),respectively,and the noise reduction level was significantly lower than that of skull scanning.Significant differences in noise reduction were not found in spine scanning sequences,while were found in skull scanning sequences.During spine and skull scanning LPN1,LPN2 and LPN3 obtained by the three calculation methods of conventional and mute sequences were all higher than the overall sound power and overall pressure levels obviously.Conclusion Mute sequence can not realize linear noise reduction for the whole frequency band,the perceived noise of the human ear during MRI scanning is related directly to the scanning sequence,and there may be some bias when only one physical indicator is involved in the noise evaluation of MRI system.[Chinese Medical Equipment Journal,2024,45(10):20-24]
		                        		
		                        		
		                        		
		                        	
8.Application of Data Mining Technology in the Screening for Gallbladder Stones: A Cross-Sectional Retrospective Study of Chinese Adults
Shuang WANG ; Chenhui BAO ; Dongmei PEI
Yonsei Medical Journal 2024;65(4):210-216
		                        		
		                        			 Purpose:
		                        			The purpose of this study was to use data mining methods to establish a simple and reliable predictive model based on the risk factors related to gallbladder stones (GS) to assist in their diagnosis and reduce medical costs. 
		                        		
		                        			Materials and Methods:
		                        			This was a retrospective cross-sectional study. A total of 4215 participants underwent annual health examinations between January 2019 and December 2019 at the Physical Examination Center of Shengjing Hospital Affiliated to China Medical University. After rigorous data screening, the records of 2105 medical examiners were included for the construction of J48, multilayer perceptron (MLP), Bayes Net, and Naïve Bayes algorithms. A ten-fold cross-validation method was used to verify the recognition model and determine the best classification algorithm for GS. 
		                        		
		                        			Results:
		                        			The performance of these models was evaluated using metrics of accuracy, precision, recall, F-measure, and area under the receiver operating characteristic curve. Comparison of the F-measure for each algorithm revealed that the F-measure values for MLP and J48 (0.867 and 0.858, respectively) were not statistically significantly different (p>0.05), although they were significantly higher than the F-measure values for Bayes Net and Naïve Bayes (0.824 and 0.831, respectively; p<0.05). 
		                        		
		                        			Conclusion
		                        			The results of this study showed that MLP and J48 algorithms are effective at screening individuals for the risk of GS.The key attributes of data mining can further promote the prevention of GS through targeted community intervention, improve the outcome of GS, and reduce the burden on the medical system. 
		                        		
		                        		
		                        		
		                        	
9.Comparison of next-generation flow cytometry and next-generation sequencing in the assessment of minimal residual disease in multiple myeloma.
Qing Qing WANG ; Li YAO ; Ming Qing ZHU ; Ling Zhi YAN ; Song JIN ; Jing Jing SHANG ; Xiao Lan SHI ; Ying Ying ZHAI ; Shuang YAN ; Wei Qin YAO ; Hong Ying YOU ; De Pei WU ; Cheng Cheng FU
Chinese Journal of Hematology 2023;44(4):328-332
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
		                        		
		                        			
		                        			Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
		                        		
		                        		
		                        		
		                        			Pregnancy
		                        			;
		                        		
		                        			Child
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Glycated Hemoglobin
		                        			;
		                        		
		                        			Cohort Studies
		                        			;
		                        		
		                        			Diabetes Mellitus/diagnosis*
		                        			;
		                        		
		                        			Sensitivity and Specificity
		                        			;
		                        		
		                        			ROC Curve
		                        			
		                        		
		                        	
            
Result Analysis