1.Arthroscopic assistance of latissimus dorsi tendon transposition for the treatment of unrepairable rotator cuff tear.
Guang XU ; Xue-Wu SUN ; Jian CHEN ; Bei-Hao GU ; Zhi-Jie ZHOU ; Pei-Hua SHI
China Journal of Orthopaedics and Traumatology 2023;36(12):1153-1158
OBJECTIVE:
To explore clinical effect of arthroscopy-assisted rotator cuff tendon transfer in treating irreparable rotator cuff tears (IRCT).
METHODS:
From May 2015 to May 2018, 23 patients with unrepairable rotator cuff tears were treated with arthroscopy-assisted rotator cuff tendon transfer, and 21 patients were followed up finally, including 8 males and 13 females, aged from 48 to 82 years old with an average of(64.3±9.1) years old;the courses of disease ranged from 6 to 36 months with an average of (14.0±6.4) months. American Rotator and Elbow Surgeons Score(ASES) and Constant-Murley score were used to evaluate clinical efficacy before surgery and at the latest follow-up.
RESULTS:
All 21 patients were followed up for 36 to 54 months with an average of (39.4±4.4) months. Axillary incision of 1 patient was redness, swelling and exudation after surgery, which healed after 3 weeks of dressing change, and exudate culture was negative. At the latest follow-up, MRI showed partial tearing of the metastatic tendon in 2 patients, but pain and movement of the affected shoulder were still better than before surgery. ASES increased from preoperative (41.0±9.6) scores to the latest follow-up (75.6±14.0) scores, and had statistical difference (t=10.50, P<0.01). Constant-Murley score increased from (49.8±7.1) scores before operation to (67.5±11.6) scores at the latest follow-up (t=11.27, P<0.01).
CONCLUSION
Arthroscopic assisted latissimus dorsalis tendon transposition restores physiological and anatomical structure of glenohumeral joint by reconstructing balance of horizontal and vertical couples of shoulder joint, thus achieving the stability of the shoulder joint, relieving shoulder pain and improving shoulder joint function.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Rotator Cuff Injuries/surgery*
;
Superficial Back Muscles
;
Rotator Cuff
;
Treatment Outcome
;
Shoulder Joint/surgery*
;
Tendon Transfer
;
Arthroscopy
;
Range of Motion, Articular/physiology*
2.Three-Dimensional Scapular Kinematics in Patients with Reverse Total Shoulder Arthroplasty during Arm Motion.
Kwang Won LEE ; Yong In KIM ; Ha Yong KIM ; Dae Suk YANG ; Gyu Sang LEE ; Won Sik CHOY
Clinics in Orthopedic Surgery 2016;8(3):316-324
BACKGROUND: There have been few reports on altered kinematics of the shoulder after reverse total shoulder arthroplasty (RTSA). We investigated differences in 3-dimensional (3D) scapular motions assessed using an optical tracking system between RTSA treated shoulders and asymptomatic contralateral shoulders during arm motion. METHODS: Thirteen patients who underwent RTSA were assessed for active arm elevation in 2 distinct elevation planes (sagittal plane flexion and scapular plane abduction). Their mean age was 72 years (range, 69 to 79 years) and the mean follow-up was 24.4 months (range, 13 to 48 months). The dominant side was the right side in all the 13 patients, and it was also the side treated with RTSA. Scapular kinematics was recorded with an optical tracking system. The scapular kinematics and the scapulohumeral rhythm (SHR) of the RTSA shoulders and asymptomatic contralateral shoulders were recorded and analyzed during arm elevation. RESULTS: There were no significant differences in internal/external rotation and anterior/posterior tilting of the scapula between shoulders during arm motion (p > 0.05). However, upward rotation of the scapula differed significantly during arm motion (p = 0.035 for sagittal plane flexion; p = 0.046 for scapular plane abduction). There were significant differences in the SHR between the two shoulders (p = 0.016 for sagittal plane flexion; p = 0.021 for scapular plane abduction). CONCLUSIONS: The shoulder kinematics after RTSA showed significant differences from the contralateral asymptomatic shoulders. Increased upward rotation and decreased SHR after RTSA indicate that RTSA shoulders use more scapulothoracic motion and less glenohumeral motion to elevate the arm.
Aged
;
Arm/physiology
;
Arthroplasty, Replacement, Shoulder/*methods
;
Biomechanical Phenomena
;
Cohort Studies
;
Female
;
Fiducial Markers
;
Humans
;
Imaging, Three-Dimensional/*methods
;
Male
;
Range of Motion, Articular/*physiology
;
Scapula/*physiology
;
Shoulder Joint/*physiology
3.Biomechanical Comparison of the Latarjet Procedure with and without Capsular Repair.
Matthew T KLEINER ; William B PAYNE ; Michelle H MCGARRY ; James E TIBONE ; Thay Q LEE
Clinics in Orthopedic Surgery 2016;8(1):84-91
BACKGROUND: The purpose of this study was to determine if capsular repair used in conjunction with the Latarjet procedure results in significant alterations in glenohumeral rotational range of motion and translation. METHODS: Glenohumeral rotational range of motion and translation were measured in eight cadaveric shoulders in 90degrees of abduction in both the scapular and coronal planes under the following four conditions: intact glenoid, 20% bony Bankart lesion, modified Latarjet without capsular repair, and modified Latarjet with capsular repair. RESULTS: Creation of a 20% bony Bankart lesion led to significant increases in anterior and inferior glenohumeral translation and rotational range of motion (p < 0.005). The Latarjet procedure restored anterior and inferior stability compared to the bony Bankart condition. It also led to significant increases in glenohumeral internal and external rotational range of motion relative to both the intact and bony Bankart conditions (p < 0.05). The capsular repair from the coracoacromial ligament stump to the native capsule did not significantly affect translations relative to the Latarjet condition; however it did cause a significant decrease in external rotation in both the scapular and coronal planes (p < 0.005). CONCLUSIONS: The Latarjet procedure is effective in restoring anteroinferior glenohumeral stability. The addition of a capsular repair does not result in significant added stability; however, it does appear to have the effect of restricting glenohumeral external rotational range of motion relative to the Latarjet procedure performed without capsular repair.
Biomechanical Phenomena/*physiology
;
Female
;
Humans
;
Humerus/physiology/surgery
;
Male
;
Middle Aged
;
Range of Motion, Articular/*physiology
;
Scapula/physiology/surgery
;
Shoulder Joint/*physiology/*surgery
4.Development of Patient Transfer Techniques based on Postural-stability Principles for the Care Helpers in Nursing Homes and Evaluation of Effectiveness.
Journal of Korean Academy of Nursing 2016;46(1):39-49
PURPOSE: This study was done to develop a postural-stability patient transfer technique for care helpers in nursing homes and to evaluate its effectiveness. METHODS: Four types of patient transfer techniques (Lifting towards the head board of the bed, turning to the lateral position, sitting upright on the bed, transferring from wheel chair to bed) were practiced in accordance with the following three methods; Care helpers habitually used transfer methods (Method 1), patient transfer methods according to care helper standard textbooks (Method 2), and a method developed by the author ensuring postural-stability (Method 3). The care helpers' muscle activity and four joint angles were measured. The collected data were analyzed using the program SPSS Statistic 21.0. To differentiate the muscle activity and joint angle, the Friedman test was executed and the post-hoc analysis was conducted using the Wilcoxon Signed Rank test. RESULTS: Muscle activity was significantly lower during Method 3 compared to Methods 1 and 2. In addition, the joint angle was significantly lower for the knee and shoulder joint angle while performing Method 3 compared to Methods 1 and 2. DISCUSSION: Findings indicate that using postural-stability patient transfer techniques can contribute to the prevention of musculoskeletal disease which care helpers suffer from due to physically demanding patient care in nursing homes.
Adult
;
Aged
;
*Caregivers
;
Female
;
Humans
;
Knee Joint/physiology
;
Male
;
Middle Aged
;
Muscle, Skeletal/physiology
;
Nursing Homes
;
Patient Transfer/*methods
;
Posture
;
Shoulder Joint/physiology
5.Clinics in diagnostic imaging (151). Acromioclavicular joint geyser sign with chronic full-thickness supraspinatus tendon (SST) tear.
Andrew Yu Keat KHOR ; Steven Bak Siew WONG
Singapore medical journal 2014;55(2):53-quiz 57
An 82-year-old man presented with neck pain, right upper limb radiculopathy and right shoulder pain. Physical examination revealed a soft lump over the right shoulder joint, as well as reduced range of shoulder movements. On magnetic resonance imaging, the soft lump was shown to be a cystic mass over the acromioclavicular joint and was related to a full-thickness supraspinatus tendon tear. This is the classic geyser sign. The pathophysiology and clinical features of the geyser sign, and its imaging features with various imaging modalities, are discussed.
Acromioclavicular Joint
;
diagnostic imaging
;
injuries
;
Aged
;
Aged, 80 and over
;
Fluoroscopy
;
Humans
;
Image Processing, Computer-Assisted
;
Magnetic Resonance Imaging
;
Male
;
Range of Motion, Articular
;
Shoulder
;
physiology
;
Shoulder Joint
;
pathology
;
Tendon Injuries
;
pathology
6.Effects of Passive Upper Arm Exercise on Range of Motion, Muscle Strength, and Muscle Spasticity in Hemiplegic Patients with Cerebral Vascular Disease.
Dong Soon SHIN ; Rhayun SONG ; Eun Kyung SHIN ; Sung Ju SEO ; Jeong Eun PARK ; Seung Yeon HAN ; Hoi Yong JUNG ; Choon Ji RYU
Journal of Korean Academy of Nursing 2012;42(6):783-790
PURPOSE: The purpose of this study was to investigate the effects of passive upper arm exercise on range of motion, muscle strength, and muscle spasticity in hemiplegic patients with cerebral vascular disease. METHODS: A quasi-experimental design with nonequivalent control group was utilized. According to inclusion criteria, 25 patients were assigned to the control group with routine care, followed by 25 to the intervention group with passive exercise for 30 minutes per session, twice a day for 2 weeks. Eighteen patients in the intervention group and 17 in the control group completed the posttest measurement, including range of motion for upper arm joints, manual muscle test, and Modified Ashworth Scale for muscle spasticity. RESULTS: The intervention group had a significantly improved range of motion in the shoulder and wrist joints. No interaction effect was found for the elbow joint. No significant differences were found in muscle strength or muscle spasticity between the groups. CONCLUSION: Results of the study indicate that passive exercise safely applied for two weeks improves range of motion in joints of the upper arm in these patients. Further study with long-term follow-up is needed to verify the role of passive exercise in preventing muscle spasticity in this population.
Adult
;
Aged
;
Cerebrovascular Disorders/*complications
;
*Exercise Therapy
;
Female
;
Hemiplegia/complications/*therapy
;
Humans
;
Male
;
Middle Aged
;
*Muscle Spasticity
;
*Muscle Strength
;
*Range of Motion, Articular
;
Shoulder Joint/physiology
;
Wrist Joint/physiology
7.Effectiveness of Subacromial Anti-Adhesive Agent Injection after Arthroscopic Rotator Cuff Repair: Prospective Randomized Comparison Study.
Chung Hee OH ; Joo Han OH ; Sae Hoon KIM ; Jae Hwan CHO ; Jong Pil YOON ; Joon Yub KIM
Clinics in Orthopedic Surgery 2011;3(1):55-61
BACKGROUND: Arthroscopic rotator cuff repair generally has a good clinical outcome but shoulder stiffness after surgery due to subacromial adhesion is one of the most common and clinically important complications. Sodium hyaluronate (HA) has been reported to be an anti-adhesive agent in a range of surgical procedures. However, there are few reports of the outcomes of arthroscopic rotator cuff repair of the shoulder. This study examined whether a subacromial injection of HA/carboxymethylated cellulose (CMC) affected the postoperative shoulder stiffness and healing of rotator cuff repair, as well as the safety of an injection. METHODS: Between January 2008 and May 2008, 80 consecutive patients with arthroscopic rotator cuff repair were enrolled. The patients were assigned randomly to the HA/CMC injection group (n = 40) or control group (n = 40). All patients were evaluated using the visual analog scale (VAS) for pain, passive range of motion at 2, 6 weeks, 3, 6, 12 months after surgery, and the functional scores at 6, 12 months postoperatively. Cuff healing was also evaluated using CT arthrography or ultrasonography at 6 or 12 months after surgery. RESULTS: The HA/CMC injection group showed faster recovery of forward flexion at 2 weeks postoperatively than the control group but the difference was not statistically significant (p = 0.09). There were no significant difference in pain VAS, internal rotation, external rotation and functional scores between two groups at each follow-up period. The functional scores improved 6 months after surgery in both groups but there were no differences between the two groups. The incidence of unhealed rotator cuff was similar in the two groups. There were no complications related to an injection of anti-adhesive agents including wound problems or infections. CONCLUSIONS: A subacromial injection of an anti-adhesive agent after arthroscopic rotator cuff repair tended to produce faster recovery in forward flexion with no adverse effects on cuff healing. However, its anti-adhesive effects after rotator cuff repair should be considered carefully with further studies.
Adult
;
Aged
;
Arthroscopy/*adverse effects/*methods
;
Carboxymethylcellulose Sodium
;
Drug Carriers
;
Female
;
Humans
;
Hyaluronic Acid/adverse effects/*therapeutic use
;
Male
;
Middle Aged
;
Pain
;
Prospective Studies
;
Range of Motion, Articular
;
Recovery of Function
;
Rotator Cuff/injuries/*surgery
;
Shoulder Joint/physiology
;
Tissue Adhesions/*prevention & control
;
Treatment Outcome
;
Viscosupplements/adverse effects/*therapeutic use
8.A comparative study between humeral head prosthesis replacement and internal fixation for treatment of comminuted proximal humeral fractures.
Hao WU ; Zhen-gang CHA ; Hong-sheng LIN ; Hui-ge HOU ; Yong-hong FENG ; Jie-ruo LI
Journal of Southern Medical University 2010;30(3):560-564
OBJECTIVETo compare the clinical efficacies of humeral head prosthesis and internal fixation in the treatment of comminuted proximal humeral fractures.
METHODSThe clinical data were analyzed for the patients with comminuted proximal humeral fractures undergoing surgeries for humeral head replacement or open reduction plus internal fixation in our hospital between January 2002 and January 2009. Constant scores were used to determine the excellent clinical outcome rates in the two groups, and the operating time, blood loss and postoperative motor scores of the shoulder were compared.
RESULTSForty patients in the humeral head replacement group were evaluated. According to the Constant scores, excellent outcomes were achieved in 16 patients, good outcomes in 18 patients, moderate in 3 patients, and poor in 3 patients, with an excellent outcome rate of 85%. In the 40 cases receiving open reduction plus internal fixation, excellent outcomes were achieved in 11 cases, good in 13 cases, moderate in 8 cases, and poor in 8 cases, with an excellent clinical outcome rate of 60%. Compared with open reduction plus internal fixation, humeral head replacement was associated with shortened operating time, reduced blood loss and better motor function recovery of the shoulder.
CONCLUSIONSReplacement of humeral head prosthesis produces better clinical outcomes than open reduction and internal fixation in patients with comminuted proximal humeral fractures, and can promote the short-term functional recovery of the shoulder with minimal surgical complications.
Aged ; Arthroplasty, Replacement ; Female ; Fracture Fixation, Internal ; methods ; Fracture Healing ; physiology ; Fractures, Comminuted ; etiology ; surgery ; Humans ; Humerus ; surgery ; Joint Prosthesis ; Male ; Middle Aged ; Prosthesis Implantation ; Shoulder Fractures ; surgery
9.Function study for finite element analysis of AB-IGHL during humeral external rotation.
Linlin ZHANG ; Jianping WANG ; Chengtao WANG
Journal of Biomedical Engineering 2009;26(3):504-507
The motions of humeral external rotation with and without the anterior band of inferior glenohumeral ligament complex (AB-IGHL) were simulated. As a result of comparison, the contact pressure and contact force are all higher when the AB-IGHL was included in the model. Therefore, it is theoretically proved that the AB-IGHL constrains the motion of humerus during humeral external rotation. The predicted values for von Mises and the maximum tense force in the AB-IGHL were 4.433 MPa and 37.32 N respectively, occurring on the humeral side of the ligament. This approach to evaluating the function of AB-IGHL would provide greater insight into the mechanical contribution of AB-IGHL to joint function, identify the mechanism of a hurt to AB-IGHL, and provide a quantitative means for developing low-risk rehabilitation protocols.
Finite Element Analysis
;
Humans
;
Ligaments, Articular
;
physiology
;
Range of Motion, Articular
;
Rotation
;
Shoulder Joint
;
anatomy & histology
;
physiology
;
Tensile Strength
10.Abduction Motion Analysis of Hemiplegic Shoulders with a Fluoroscopic Guide.
Yonsei Medical Journal 2007;48(2):247-254
PURPOSE: We investigated the usefulness of video based, fluoroscopically guided abduction motion analysis of hemiplegic shoulders. PATIENTS AND METHODS: Twenty-two stroke patients with Brunnstrom stages 3-4 (Group 1) or 5-6 (Group 2) were enrolled in this study. Patients with shoulder pain and significant spasticity (MAS 2) were excluded. We recorded motion pictures of the abductions of affected and unaffected shoulder joints under an AP fluoroscopic guide. Lateral scapular slide distances (D1: T2- superior angle, D2: T3- scapular spine, D3: T7-inferior angle) were measured at 30 degrees, 60 degrees, 90 degrees during glenohumeral abduction in a captured photographic image. The angles of scapular rotation and trajectory (stromotion) of the humeral head center, relative to the 3rd thoracic spine in the abduction motion were analyzed. RESULTS: In Group 1, a significant difference was found in the lateral scapular slide distance between the affected and sound sides. However, no significant side to side difference was found in Group 2. Scapular angles in abduction were also increased in Group 1. Patients with a more synergistic movement pattern showed less scapular stabilizing muscle activity and, instead, exhibited a compensatory "shrugging" like motion accomplished by spinal tilting. CONCLUSION: The present findings support the notion that the above parameters of fluoroscopically guided shoulder abduction motion analysis correlate well with clinical findings. These parameters should be useful for evaluations of hemiplegic shoulder biomechanics.
Video Recording
;
Shoulder Joint/*physiopathology/radiography
;
Movement/*physiology
;
Middle Aged
;
Humans
;
Hemiplegia/etiology/*physiopathology/radiography
;
Functional Laterality
;
Fluoroscopy
;
Cerebrovascular Accident/complications
;
Cerebral Infarction/complications
;
Aged

Result Analysis
Print
Save
E-mail