1.Clinical study of modified suspension reduction method combined with percutaneous vertebroplasty in the treatment of thoracolumbar osteoporotic compression fracture
Yu-Zhou LU ; Yu WANG ; Xiao-Xu YANG ; Cheng-Qiang WU ; Shou-Cui ZHANG ; Jin-Guo WANG ; Ya-Dong WU ; Dong QIN ; Lin DING
China Journal of Orthopaedics and Traumatology 2024;37(1):21-26
Objective To investigate the clinical effect of modified suspension reduction method combined with percuta-neous vertebroplasty in the treatment of osteoporotic thoracolumbar compression fractures.Methods From February 2020 to October 2021,92 patients with thoracolumbar osteoporotic compression fracture were treated by percutaneous vertebroplasty.According to different treatment methods,they were divided into the observation group and the control group.The observation group was treated with modified suspension reduction and then percutaneous vertebroplasty,while the control group was treated with percutaneous vertebroplasty alone.The observation group(47 cases),including 20 males and 27 females,the age ranged from 59 to 76 years old with an average of(69.74±4.50)years old,fractured vertebral bodies:T10(2 cases),T11(7 cases),T12(19 cases),L1(14 cases),L2(5 cases);the control group(45 cases),including 21 males and 24 females,the age ranged from 61 to 78 years old with an average of(71.02±3.58)years old,fractured vertebral bodies:T10(3 cases),T11(8 cases),T12(17 cas-es),L1(12 cases),L2(5 cases);The leakage of bone cement were observed,the visual analogue scale(VAS),Oswestry lumbar dysfunction index(ODI),anterior vertebrae height(AVH),Cobb angle of kyphosis and the amount of bone cement injected before and after operation were recorded and compared between the two groups.Results All patients were followed up,ranged from 6 to1O with an average of(8.45±1.73)months.Two patients ocurred bone cement leakage in observation group and 3 pa-tients in control group.AVH of observation group increased(P<0.05)and Cobb angle of injured vertebrae decreased(P<0.05).Cobb angle of injured vertebrae and AVH of the control group were not significantly changed(P>0.05).Cobb angle of injured vertebrae of the observation group was lower than that of control group(P<0.05)and AVH was higher than that of the control group(P<0.05).In the observation group,VAS before operation and 1 week,3 and 6 months after operation respective-ly were(7.32±1.05)scores,(3.56±1.18)scores,(1.83±0.67)scores,(1.27±0.34)scores,and ODI were(40.12±14.69)scores,(23.76±10.19)scores,(20.15±6.39)scores,(13.45±3.46)scores.In the control group,VAS before operation and 1 week,3 and 6 months after operation respectively were(7.11±5.26)scores,(3.82±0.68)scores,(1.94±0.88)scores,(1.36± 0.52)scores,and ODI were(41.38±10.23)scores,(25.13±14.22)scores,(20.61±5.82)scores,(14.55±5.27)scores.The scores of VAS and ODI after operation were lower than those before operation(P<0.05),but there was no significant difference between the two groups(P<0.05).Conclusion Modified suspension reduction method combined with PVP surgery for osteo-porotic thoracolumbar compression fractures has achieved good clinical results,which can effectively relieve lumbar back pain,restore vertebral height,correct kyphosis,improve lumbar function and patients'quality of life.
2.Effect of different blood pressure stratification on renal function in diabetic population
Yong-Gang CHEN ; Shou-Ling WU ; Jin-Feng ZHANG ; Shuo-Hua CHEN ; Li-Wen WANG ; Kai YANG ; Hai-Liang XIONG ; Ming GAO ; Chun-Yu JIANG ; Ye-Qiang LIU ; Yan-Min ZHANG
Medical Journal of Chinese People's Liberation Army 2024;49(6):663-669
Objective To investigate the effect of varying blood pressure stratification on renal function in the diabetic population.Methods A prospective cohort study was conducted,enrolling 9 489 diabetic patients from a total of 101 510 Kailuan Group employees who underwent health examinations between July 2006 and October 2007.The follow-up period was(8.6±4.0)years.Participants were categorized into four groups based on their baseline blood pressure levels:normal blood pressure(systolic blood pressure<120 mmHg and diastolic blood pressure<80 mmHg),elevated blood pressure(systolic blood pressure 120-130 mmHg and diastolic blood pressure<80 mmHg),stage 1 hypertension(systolic blood pressure 130-140 mmHg and/or diastolic blood pressure 80-90 mmHg),and stage 2 hypertension(systolic blood pressure≥140 mmHg and/or diastolic blood pressure≥90 mmHg).The incidence density of chronic kidney disease(CKD)was compared among these groups.A multivariate Cox proportional hazards regression model was employed to assess the effects of different blood pressure levels on renal function in diabetic patients,with the stability of the results confirmed using a multivariate time-dependent Cox proportional hazards model.Sensitivity analysis was conducted after excluding cases of cardiovascular disease(CVD)during follow-up,and cases using antihypertensive and antidiabetic medications at baseline.Results(1)At baseline,stage 1 hypertension patients demonstrated statistically significant higher differences with age and body mass index(BMI)compared to normal blood pressure group(P<0.05).(2)By the end of the follow-up,2 294 cases of CKD were identified,including 1 117 cases of estimated glomerular filtration rate(eGFR)decline and 1 575 cases of urinary protein.The incidences density of CKD,eGFR decline and urinary protein for stage 1 hypertension group were 39.4,16.3 and 25.5 per thousand person-years,respectively,all of which were statistically significant different from normal blood pressure group(log-rank test,P<0.01).(3)Multivariate Cox regression analysis revealed that,compared to the normal blood pressure group,stage 1 hypertension was associated with a 29%increased risk of CKD(HR=1.29,95%CI 1.09-1.52)and a 40%increased risk of eGFR decline(HR=1.40,95%CI 1.08-1.80)in diabetic individuals.Conclusion Stage 1 hypertension significantly increases the risk of CKD and eGFR decline in diabetic individuals,with a particularly notable effect on the risk of eGFR decline.
3.Orthopaedic robot assisted closed reduction and cannulated screw internal fixation for the treatment of femoral neck fractures
Shou-Hai JIANG ; Chuan-Kai ZHANG ; Fang-Teng JIA ; Qiang CHEN ; Meng XU ; Pei-Lin YANG ; Yu-Shuai ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(2):119-123
Objective To investigate the preliminary clinical effect of closed reduction and cannulated nail internal fixa-tion for femoral neck fracture assisted by robot navigation and positioning system.Methods From July 2019 to January 2020,16 cases of femoral neck fracture(navigation group)were treated with closed reduction and internal fixation guided by robot system,including 7 males and 9 females,aged 25 to 72 years old with an average of(53.61±5.45)years old;Garden classification of fracture:3 cases of type Ⅰ,3 cases of type Ⅱ,8 cases of type Ⅲ,2 cases of type Ⅳ.Non navigation group(control group):20 cases of femoral neck fracture were treated with closed reduction and hollow nail internal fixation,8 males and 12 females,aged 46 to 70 years old with an average of(55.23±4.64)years old;Garden type Ⅰ in 2 cases,type Ⅱ in 4 cases,type Ⅲ in 11 cases,type Ⅳ in 3 cases.The operation time,fluoroscopy times,guide needle drilling times,screw adjustment times,intraoperative bleeding volume and other indicators of two groups were evaluated.Results Both groups were followed up for 12 to 18 months with an average of(15.6±2.8)months.The fractures of both groups were healed without delayed union and nonunion.There was no significant difference in healing time between two groups(P=0.782).There was no significant differ-ence in Harris scores between two groups at the last follow-up(P=0.813).There was no significant difference in operation time between two groups(P>0.05).There were significant differences between two groups in fluoroscopy times,guide needle drilling times,hollow screw replacement times,and intraoperative bleeding volume(P<0.05).Conclusion Closed reduction and hollow screw internal fixation assisted by robot navigation system for femoral neck fracture has the advantages of minimally invasive operation,precise screw placement,and reduction of X-ray radiation damage during operation.
4.Effect of Kümmell's disease with kyphosis on spinal-pelvic sagittal parameters
Shou-Yu HE ; Ji-Kang MIN ; Hai-Dong LI ; Qiang-Hua ZHANG ; Ji-Lin DAI
China Journal of Orthopaedics and Traumatology 2024;37(2):142-147
Objective To explore the effect of Kümmell's disease with kyphosis on the sagittal morphology of the spine-pelvis.Methods A retrospective analysis of 34 patients of Kümmell's disease with kyphosis(Kümmell group)admitted from August 2015 to September 2022,including 10 males and 24 females with an average age of(71.1±8.5)years old.A control group of 37 asymptomatic population aged(69.3±6.7)years old was matched.Spinal-pelvic sagittal parameters were measured on the anterior-posterior and lateral X-rays of the whole spine in the standing position,including segmental kyphosis(SK)or thoracolumbar kyphosis(TLK),thoracic kyphosis(TK),lumbar lordosis(LL),pelvic incidence(PI),pelvic tilt(PT),sacral slope(SS),sagittal vertical axis(SVA),T1 pelvic angle(TPA)and PI-LL.Vertebral wedge angle(WA)in Kümmell was mea-sured and differences in parameters among groups were analyzed and the relationship between spino-pelvic parameters and WA,SK were also investigated.Results TK,SK,PT,SVA,TPA and PI-LL in Kümmell group were significantly larger than those in control group(P<0.05),LL and SS in Kümmell group were significantly decreased than those in control group(P<0.05),and there was no significant difference in PI between two groups(P>0.05).In Kümmell group,WA(30.8±5.9)° showed a positive correlation with SK and TK(r=0.366,0.597,P<0.05),and SK was significantly correlated with LL and SS(r=0.539,-0.591,P<0.05).Strong positive correlation between LL and PI,SS,SVA,TPA,PI-LL were also confirmed in patients with Kümmell with kyphosis(r=0.559,0.741,-0.273,-0.356,-0.882,P<0.05).Conclusion Patients with Kümmell with kyphosis not only have segmental kyphosis,but also changes the overall spinal-pelvic sagittal parameters,including loss of lumbar lordosis,pelvic retrorotation,trunk forward tilt.The surgical treatment of Kümmell disease should not only pay attention to the recovery of the height of the collapsed vertebra,but also focus on the overall balance of the spine-pelvic sagittal plane for patients with kyphosis.
5.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
6.Cancer statistics in China, 2016.
Rong Shou ZHENG ; Si Wei ZHANG ; Ke Xin SUN ; Ru CHEN ; Shao Ming WANG ; Li LI ; Hong Mei ZENG ; Wen Qiang WEI ; Jie HE
Chinese Journal of Oncology 2023;45(3):212-220
Objective: Data for 2016 from cancer registries were used to estimate cancer incidence and mortality in China in 2016. Methods: According to the quality control process of the National Central Cancer Registry, the data from 683 cancer registries submitted by each province were evaluated, and the data of 487 cancer registries were qualified and included in the final analysis. Age-specific incidence and mortality rates were calculated by area (urban/rural), sex, age and cancer site, combined with national population data to estimate cancer incidence and mortality in China in 2016. Chinese population census in 2000 and Segi's population were used for age-standardized incidence and mortality rates. Results: Total population covered by 487 cancer registries was 381 565 422 (192 628 370 in urban and 188 937 052 in rural areas). The percentages of morphologically verified (MV%) and death certificate-only cases (DCO%) accounted for 68.31% and 1.40%, respectively, and the mortality to incidence ratio was 0.61. It was estimated about 4 064 000 new cases occurred in China in 2016, with the crude incidence rate being 293.91/100 000 (the rates of males and females were 315.52/100 000 and 271.23/100 000), age-standardized incidence rates by Chinese standard population (ASIRC) and by world standard population (ASIRW) were 190.76/100 000 and 186.46/100 000, with the cumulative incidence rate (0-74 years old) being 21.42%. The crude incidence and ASIRC were 314.74/100 000 and 196.38/100 000 in urban areas, whereas in rural areas, they were 265.90/100 000 and 182.21/100 000, respectively. It was estimated about 2 413 500 cancer deaths occurred in China in 2016, the crude mortality rate was 174.55/100 000 (216.16/100 000 in males and 130.88/100 000 in females), the age-standardized mortality rates by Chinese standard population (ASMRC) and by world standard population (ASMRW) were 106.00/100 000 and 105.19/100 000, and the cumulative mortality rate (0-74 years old) was 11.85%. The crude mortality and ASMRC were 180.31/100 000 and 104.44/100 000 in urban areas, whereas in rural areas, they were 166.81/100 000 and 108.01/100 000, respectively. The most common cancer cases include lung, colorectal, stomach, liver and female breast cancers. The top five cancers accounted for about 57.27% of all cancer cases. The most common cancer deaths included lung, liver, stomach, colorectal and esophageal cancers. The top five cancers accounted for about 69.25% of all cancer deaths. Conclusions: The burden of cancer shows a continuous increasing trend in China. Regional and gender differences in cancer burden are obvious. The cancer patterns still show the coexistence of cancer patterns in developed countries and developing countries. The situation of cancer prevention and control is still serious in China.
Male
;
Humans
;
Female
;
Infant, Newborn
;
Infant
;
Child, Preschool
;
Child
;
Adolescent
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Urban Population
;
Breast Neoplasms
;
Esophageal Neoplasms
;
Rural Population
;
China/epidemiology*
;
Registries
;
Incidence
;
Colorectal Neoplasms
7.Intelligent co-design of material, process, and equipment for manufacturing high-quality traditional Chinese medicine preparations.
Bing XU ; Yan-Jiang QIAO ; Shou-Ying DU ; Zhi-Qiang ZHANG ; Wei XIAO
China Journal of Chinese Materia Medica 2023;48(15):3977-3987
In the context of Pharma 4.0, the design tools that support the pharmaceutical Quality by Design(QbD) are iterating fast toward intelligent or smart design. The conventional development methods for traditional Chinese medicine(TCM) preparations have the limitations such as over dependence on experience, low dimensions for the designed experiment parameters, poor compatibility between the process and equipment, and high trial-and-error cost during process scale-up. Therefore, this paper innovatively proposed the intelligent co-design involving material, process, and equipment for manufacturing high-quality TCM preparations, and introduced the design philosophy, targets, tools, and applications with TCM oral solid dosage(OSD) as an example. In terms of design philosophy, the pharmaceutical design tetrahedron composed of critical material attributes, critical process parameters, critical equipment attributes, and critical quality attributes was developed. The design targets were put forward based on the product performance classification system. The design tools involve a design platform that contains several modules, such a as the iTCM material database, the processing route classification system, the system modeling and simulation, and reliability-based optimization. The roles of different modules in obtaining essential and universal design knowledge of the key common manufacturing units were introduced. At last, the applications of the co-design methodology involving material, process, and equipment in the high shear wet granulation process development and the improvement of the dissolving or dispersion capability of TCM formula granules are illustrated. The research on advanced pharmaceutical design theory and methodology will help enhance the efficiency and reliability of drug development, improve the product quality, and promote the innovation of high-end TCM products across the industry.
Medicine, Chinese Traditional
;
Reproducibility of Results
;
Quality Control
;
Computer Simulation
;
Commerce
;
Pharmaceutical Preparations
;
Drugs, Chinese Herbal
8.Analysis of risk factors for hypomagnesemia in elderly patients with sepsis and the impact of hypomagnesemia on prognosis
Jinqiang QIAN ; Guanghui XIAO ; Songtao SHOU ; Qiang ZHANG
Chinese Journal of Geriatrics 2023;42(4):415-419
Objective:To explore the risk factors of hypomagnesemia in elderly patients with sepsis and the influence of hypomagnesemia on the prognosis of elderly patients with sepsis.Methods:In this retrospective study, 249 elderly patients with sepsis or septic shock were recruited between January 2018 and January 2021 from the Department of Geriatrics and the Department of Emergency Medicine, General Hospital of Tianjin Medical University, and relevant clinical data were collected.The Logistic regression analysis model was used to identify the relationship between risk factors and hypomagnesemia in patients with sepsis.The prognosis criteria such as hospitalization time in intensive care unit(ICU), 28-day mortality rate, mechanical ventilation time, double infection rate, shock reversal time, etc., were compared between the hypomagnesemia group and the normal magnesium group.Results:Among the 249 elderly patients with sepsis, 187 had normal blood magnesium, 43 had low blood magnesium and 19 had high blood magnesium, accounting for 75.10%, 17.27% and 7.63%, respectively.Compared with the normal blood magnesium group, elderly sepsis patients with hypomagnesemia had a longer hospitalization time in ICU[(16.21±3.68)d vs.(13.86±3.58)d, t=-4.845, P=0.036], and a significantly prolonged mechanical ventilation time[11(3, 18)d vs.3(1, 6)d, Z=-1.782, P=0.033]. There was no significant difference in mortality and double infection rate between the two groups(both P>0.05). The sequential organ failure assessment(SOFA)score of elderly sepsis patients in the low magnesium group was significantly higher than that in the normal magnesium group[(5.69±1.28)scores vs.(3.09±0.68)scores, t=-0.322, P=0.008], but there was no significant difference in acute physiology and chronic health evaluation(APACHE) Ⅱ score between the two groups( P>0.05). Multivariate Logistic regression analysis showed that high SOFA score( OR=1.111, 95% CI: 1.025-1.758, P=0.001)was an independent risk factor for hypomagnesemia. Conclusions:A high SOFA score is an independent risk factor for hypomagnesemia in elderly sepsis patients, and the clinical prognosis of elderly sepsis patients with hypomagnesemia is poor.
10.A randomized controlled trial to evaluate efficacy and safety of early conversion to a low-dose calcineurin inhibitor combined with sirolimus in renal transplant patients
Xiang ZHENG ; Weijie ZHANG ; Hua ZHOU ; Ronghua CAO ; Zhangfei SHOU ; Shuwei ZHANG ; Ying CHENG ; Xuchun CHEN ; Chenguang DING ; Zuofu TANG ; Ning LI ; Shaohua SHI ; Qiang ZHOU ; Qiuyuan CHEN ; Gang CHEN ; Zheng CHEN ; Peijun ZHOU ; Xiaopeng HU ; Xiaodong ZHANG ; Ning NA ; Wei WANG
Chinese Medical Journal 2022;135(13):1597-1603
Background::The calcineurin inhibitor (CNI)-based immune maintenance regimen that is commonly used after renal transplantation has greatly improved early graft survival after transplantation; however, the long-term prognosis of grafts has not been significantly improved. The nephrotoxicity of CNI drugs is one of the main risk factors for the poor long-term prognosis of grafts. Sirolimus (SRL) has been employed as an immunosuppressant in clinical practice for over 20 years and has been found to have no nephrotoxic effects on grafts. Presently, the regimen and timing of SRL application after renal transplantation vary, and clinical data are scarce. Multicenter prospective randomized controlled studies are particularly rare. This study aims to investigate the effects of early conversion to a low-dose CNI combined with SRL on the long-term prognosis of renal transplantation.Methods::Patients who receive four weeks of a standard regimen with CNI + mycophenolic acid (MPA) + glucocorticoid after renal transplantation in multiple transplant centers across China will be included in this study. At week 5, after the operation, patients in the experimental group will receive an additional administration of SRL, a reduction in the CNI drug doses, withdrawal of MPA medication, and maintenance of glucocorticoids. In addition, patients in the control group will receive the maintained standard of care. The patients’ vital signs, routine blood tests, routine urine tests, blood biochemistry, serum creatinine, BK virus (BKV)/cytomegalovirus (CMV), and trough concentrations of CNI drugs and SRL at the baseline and weeks 12, 24, 36, 48, 72, and 104 after conversion will be recorded. Patient survival, graft survival, and estimated glomerular filtration rate will be calculated, and concomitant medications and adverse events will also be recorded.Conclusion::The study data will be utilized to evaluate the efficacy and safety of early conversion to low-dose CNIs combined with SRL in renal transplant patients.Trial registration::Chinese Clinical Trial Registry, ChiCTR1800017277.

Result Analysis
Print
Save
E-mail