1.Clinical trial of Morinda officinalis oligosaccharides in the continuation treatment of adults with mild and moderate depression
Shu-Zhe ZHOU ; Zu-Cheng HAN ; Xiu-Zhen WANG ; Yan-Qing CHEN ; Ya-Ling HU ; Xue-Qin YU ; Bin-Hong WANG ; Guo-Zhen FAN ; Hong SANG ; Ying HAI ; Zhi-Jie JIA ; Zhan-Min WANG ; Yan WEI ; Jian-Guo ZHU ; Xue-Qin SONG ; Zhi-Dong LIU ; Li KUANG ; Hong-Ming WANG ; Feng TIAN ; Yu-Xin LI ; Ling ZHANG ; Hai LIN ; Bin WU ; Chao-Ying WANG ; Chang LIU ; Jia-Fan SUN ; Shao-Xiao YAN ; Jun LIU ; Shou-Fu XIE ; Mao-Sheng FANG ; Wei-Feng MI ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):815-819
Objective To observe the efficacy and safety of Morinda officinalis oligosaccharides in the continuation treatment of mild and moderate depression.Methods An open,single-arm,multi-center design was adopted in our study.Adult patients with mild and moderate depression who had received acute treatment of Morinda officinalis oligosaccharides were enrolled and continue to receive Morinda officinalis oligosaccharides capsules for 24 weeks,the dose remained unchanged during continuation treatment.The remission rate,recurrence rate,recurrence time,and the change from baseline to endpoint of Hamilton Depression Scale(HAMD),Hamilton Anxiety Scale(HAMA),Clinical Global Impression-Severity(CGI-S)and Arizona Sexual Experience Scale(ASEX)were evaluated.The incidence of treatment-related adverse events was reported.Results The scores of HAMD-17 at baseline and after treatment were 6.60±1.87 and 5.85±4.18,scores of HAMA were 6.36±3.02 and 4.93±3.09,scores of CGI-S were 1.49±0.56 and 1.29±0.81,scores of ASEX were 15.92±4.72 and 15.57±5.26,with significant difference(P<0.05).After continuation treatment,the remission rate was 54.59%(202 cases/370 cases),and the recurrence rate was 6.49%(24 cases/370 cases),the recurrence time was(64.67±42.47)days.The incidence of treatment-related adverse events was 15.35%(64 cases/417 cases).Conclusion Morinda officinalis oligosaccharides capsules can be effectively used for the continuation treatment of mild and moderate depression,and are well tolerated and safe.
2.A Comprehensive Study of the Association between LEPR Gene rs1137101 Variant and Risk of Digestive System Cancers
Qiong Wei HU ; Guang Wei ZHOU ; Wei Guang ZHOU ; Xi Jia LIAO ; Xing Jia SHI ; FengYang XIE ; Heng Shou LI ; Yong WANG ; Hong Xian FENG ; Li Xiu GU ; Feng Bi CHEN
Biomedical and Environmental Sciences 2024;37(5):445-456
Objective The leptin receptor,encoded by the LEPR gene,is involved in tumorigenesis.A potential functional variant of LEPR,rs1137101(Gln223Arg),has been extensively investigated for its contribution to the risk of digestive system(DS)cancers,but results remain conflicting rather than conclusive.Here,we performed a case-control study and subsequent meta-analysis to examine the association between rs1137101 and DS cancer risk. Methods A total of 1,727 patients with cancer(gastric/liver/colorectal:460/480/787)and 800 healthy controls were recruited.Genotyping of rs1137101 was conducted using a polymerase chain reaction-restriction fragment length polymorphism(PCR-RFLP)assay and confirmed using Sanger sequencing.Twenty-four eligible studies were included in the meta-analysis. Results After Bonferroni correction,the case-control study revealed that rs1137101 was significantly associated with the risk of liver cancer in the Hubei Chinese population.The meta-analysis suggested that rs1137101 is significantly associated with the risk of overall DS,gastric,and liver cancer in the Chinese population. Conclusion The LEPR rs1137101 variant may be a genetic biomarker for susceptibility to DS cancers(especially liver and gastric cancer)in the Chinese population.
3.Research on Objective Characteristics of Tongue Manifestation in 315 Patients with Coronary Heart Disease
Mengyao DUAN ; Chuhao WANG ; Yuquan TAN ; Kun LIAN ; Xintian SHOU ; Yang JIANG ; Boyan MAO ; Zhixi HU
Journal of Traditional Chinese Medicine 2024;65(9):921-927
ObjectiveTo investigate the objective characteristics of tongue manifestations in patients with coronary heart disease (CHD). MethodsA total of 315 participants with CHD were recruited in the CHD group, and 211 healthy participants who underwent physical examination were recruited as the healthy control group. In addition, according to the common comorbidities (primary hypertension, carotid atherosclerosis, type 2 diabetes mellitus, fatty liver, hyperlipidaemia, heart failure, and cerebral infarction) in 315 participants with CHD, each comorbidity was classified into a group of comorbidities with that disease and a group of non-comorbidities. Tongue images were captured using a TFDA-1 tongue diagnostic instrument to characterise the tongue body (TB) and tongue coating (TC), comparing the RGB, HIS, and Lab colour spaces in the chromaticity index (R, red; G, green; B, blue; H, hue; I, intensity; S, saturation; L, lightness; a, red-green axis; b, yellow-blue axis), the tongue coating thickness index (per-All), contrast (CON), angular second moment (ASM), entropy (ENT), and mean (MEAN) in texture metrics. ResultsCompared with the healthy control group, the characteristic indexes of tongue body in CHD group showed lower TB-R, TB-G, TB-B, TB-I, TB-L and higher TB-H, TB-b; and the characteristic indexes of tongue coating in CHD group showed lower TC-R, TC-B and higher TC-CON, TC-MEAN, TC-H, TC-b (P<0.05 or P<0.01). Compared with non-combined primary hypertension group, CHD combined primary hypertension group showed higher per-All, TB-G, TB-L, and lower TB-a, TC-a (P<0.05); compared with the non-combined carotid atherosclerosis group, CHD combined carotid atherosclerosis group showed higher TB-CON, TB-ENT, TB-MEAN, and lower TB-ASM (P<0.05 or P<0.01); compared with the non-combined type 2 diabetes mellitus group, CHD combined type 2 diabetes mellitus group showed lower per-All and higher TB-H (P<0.05 or P<0.01); compared with the non-combined fatty liver group, CHD combined fatty liver group showed higher TB-CON, TB-MEAN, TB-ENT, and lower TB-ASM and TC-S (P<0.05 or P<0.01); compared with the non-combined hyperlipidaemia group, CHD combined hyperlipidaemia group showed lower TB-S and TB-a (P<0.05); compared with non-combined heart failure group, CHD combined heart failure group showed lower TB-R, TB-G, TB-I, TB-L, and higher TB-a (P<0.05 or P<0.01); compared with non-combined cerebral infarction group, CHD combined cerebral infarction group showed higher TC-CON, TC-ENT, TC-MEAN, and lower TC-ASM (P<0.05 or P<0.01). ConclusionCompared to healthy individuals, patients with CHD tend to have darker tongue colours and rougher TC textures. Compared with non-comorbidity participants, those with primary hypertension tended to be lighter tongue colour and thicker tongue coating, those with carotid atherosclerosis had paler tongue body, those with type 2 diabetes mellitus had thinner tongue coating, those with fatty liver disease had paler tongue body and whiter tongue colour, those with hyperlipidaemia and heart failure had paler tongue colour, and those with cerebral infarction had rougher tongue texture.
4.Atrial fibrillation detection using millimeter-wave radar
Hengji ZHOU ; Yihan YANG ; Yuanhui HU ; Yuguang CHU ; Xintian SHOU ; Yaping YOU ; Wenjing XUE ; Shaowei FAN ; Yong WANG ; Huiliang SHEN
Chinese Journal of Medical Physics 2024;41(1):81-87
A novel technology is proposed for non-contact and real-time detection of atrial fibrillation using millimeter-wave radar.A 60 GHz PCR millimeter wave radar is used to continuously detect the chest echo signal of the subject.After signal acquisition,I-Q signal is generated through I-Q demodulation,and the signal phase information is extracted using effective points phase trend evaluation for obtaining the signals from oscillations in the chest wall,from which the respiratory signals and cardiac signals are extracted through digital filtering for the analysis of cardiac movement.Whether the atrial fibrillation occurs or not is determined by the characteristics of atrial fibrillation wave in the time domain.The effective points phase trend evaluation for extracting more accurate signal phase information and the time-domain method for real-time atrial fibrillation detection are the innovations of the study.The experimental results show that the proposed method achieves a detection accuracy of 99.2%in clinic.
5.Long-term hypomethylating agents in patients with myelodysplastic syndromes: a multi-center retrospective study
Xiaozhen LIU ; Shujuan ZHOU ; Jian HUANG ; Caifang ZHAO ; Lingxu JIANG ; Yudi ZHANG ; Chen MEI ; Liya MA ; Xinping ZHOU ; Yanping SHAO ; Gongqiang WU ; Xibin XIAO ; Rongxin YAO ; Xiaohong DU ; Tonglin HU ; Shenxian QIAN ; Yuan LI ; Xuefen YAN ; Li HUANG ; Manling WANG ; Jiaping FU ; Lihong SHOU ; Wenhua JIANG ; Weimei JIN ; Linjie LI ; Jing LE ; Wenji LUO ; Yun ZHANG ; Xiujie ZHOU ; Hao ZHANG ; Xianghua LANG ; Mei ZHOU ; Jie JIN ; Huifang JIANG ; Jin ZHANG ; Guifang OUYANG ; Hongyan TONG
Chinese Journal of Hematology 2024;45(8):738-747
Objective:To evaluate the efficacy and safety of hypomethylating agents (HMA) in patients with myelodysplastic syndromes (MDS) .Methods:A total of 409 MDS patients from 45 hospitals in Zhejiang province who received at least four consecutive cycles of HMA monotherapy as initial therapy were enrolled to evaluate the efficacy and safety of HMA. Mann-Whitney U or Chi-square tests were used to compare the differences in the clinical data. Logistic regression and Cox regression were used to analyze the factors affecting efficacy and survival. Kaplan-Meier was used for survival analysis. Results:Patients received HMA treatment for a median of 6 cycles (range, 4-25 cycles) . The complete remission (CR) rate was 33.98% and the overall response rate (ORR) was 77.02%. Multivariate analysis revealed that complex karyotype ( P=0.02, OR=0.39, 95% CI 0.18-0.84) was an independent favorable factor for CR rate. TP53 mutation ( P=0.02, OR=0.22, 95% CI 0.06-0.77) was a predictive factor for a higher ORR. The median OS for the HMA-treated patients was 25.67 (95% CI 21.14-30.19) months. HMA response ( P=0.036, HR=0.47, 95% CI 0.23-0.95) was an independent favorable prognostic factor, whereas complex karyotype ( P=0.024, HR=2.14, 95% CI 1.10-4.15) , leukemia transformation ( P<0.001, HR=2.839, 95% CI 1.64-4.92) , and TP53 mutation ( P=0.012, HR=2.19, 95% CI 1.19-4.07) were independent adverse prognostic factors. There was no significant difference in efficacy and survival between the reduced and standard doses of HMA. The CR rate and ORR of MDS patients treated with decitabine and azacitidine were not significantly different. The median OS of patients treated with decitabine was longer compared with that of patients treated with azacitidine (29.53 months vs 20.17 months, P=0.007) . The incidence of bone marrow suppression and pneumonia in the decitabine group was higher compared with that in the azacitidine group. Conclusion:Continuous and regular use of appropriate doses of hypomethylating agents may benefit MDS patients to the greatest extent if it is tolerated.
6.Interpretation of report on cardiovascular health and diseases in China 2023
Ming-Bo LIU ; Xin-Ye HE ; Xiao-Hong YANG ; Zeng-Wu WANG ; Sheng-Shou HU
Chinese Journal of Interventional Cardiology 2024;32(10):541-550
Due to the prominent unhealthy lifestyle of residents,accelerated population aging,and urbanization processes in our country,the impact of cardiovascular disease(CVD)risk factors on public health is becoming increasingly significant.The prevalence of cardiovascular disease(CVD)in China is still on the rise.It is estimated that there are 330 million people with CVD,including 13 million cases of stroke,11.39 million cases of coronary heart disease,8.9 million cases of heart failure,5 million cases of pulmonary heart disease,4.87 million atrial fibrillation,2.5 million cases of rheumatic heart disease,2 million cases of congenital heart disease,45.3 million cases of peripheral arterial disease,and 245 million cases of hypertension.The economic burden of CVD on residents and society is increasingly heavy,making it a significant public health issue.The turning point for the prevention and control of CVD has not yet arrived,and it is urgent to strengthen government-led efforts in CVD prevention and control.
7.Applications and advances of desensitizing therapeutic agents in pre-sensitized renal transplantation
Jiating WANG ; Yuting HU ; Jie DING ; Zhangfei SHOU
Chinese Journal of Organ Transplantation 2024;45(3):188-193
Kidney transplantation (KT) is one primary treatment of end-stage renal disease (ESRD). As reported by different centers, 10-year survival rate of transplanted kidneys fluctuates from 75% to 80%. Capable of reducing all-cause mortality in renal failure, KT can significantly improve survival rate and quality-of-life of ESRD patients. The risk of post-transplant rejection is much higher in pre-sensitised recipients than in non-sensitised ones due to the pre-existing anti-human leukocyte antigen antibodies. However, with a rapid development of various desensitisation techniques, transplantation rate and postoperative human/kidney survival rate of recipients have been greatly enhanced. And presensitisation is no longer a contraindication to KT. This review focused upon the latest advances in desensitisation therapeutic agents for pre-sensitised KT.
8.Perioperative application of immunoadsorption in highly sensitized kidney transplant recipients: single-center experience
Haojie HUANG ; Jie DING ; Yuting HU ; Dan SONG ; Ming ZHU ; Feng WANG ; Heng ZHENG ; Chenjie HUANG ; Qingling ZOU ; Zhangfei SHOU
Chinese Journal of Organ Transplantation 2024;45(10):702-709
Objective:To explore the clinical efficacy of immunoadsorption in highly sensitized kidney transplant (KT) candidates.Methods:From September 2019 to April 2023, the relevant clinical data were retrospectively reviewed for 26 highly sensitized KT recipients. Protein A immunoadsorption desensitization therapy was offered after KT. The effect of immunosorbent on reducing anti-human leukocyte antigen (HLA) antibodies was summarized. And operative success rate and postoperative complication incidence were calculated.Results:The mean number of treatment session was (10.76±5.53). The highest level of HLA-Ⅰ antibody mean fluorescence intensity (MFI) dropped from (17 921±4 442) to (7 333±6 434) with a decline of 59% and HLA-Ⅱ antibody MFI decreased from (21 135±5 245) to (10 989±7 627) with a decline of 48%. The differences were statistically significant (both P<0.001). All kidneys were harvested from cadavers. The complications were acute antibody mediated rejection (7 cases), perioperative pulmonary infection (3 cases) and myelosuppression (2 cases). The average follow-up period was (30.8±12.6) month. The graft survival rate was 88.5% (23/26) and the recipient survival rate 100% (26/26) . Conclusions:Immunoadsorption therapy can effectively reduce HLA antibody in highly sensitized KT candidates, thereby increasing the probability of successful KT. In terms of safety, immunosorbent therapy may boost the potential risks of infection and myelosuppression. It requires heightened attention.
9.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
10.Long-term outcome of EVAHEART I implantable ventricular assist device for the treatment of end stage heart failure: clinical 3-year follow-up results of 15 cases.
Hai Bo CHEN ; Xian Qiang WANG ; Juan DU ; Jia SHI ; Bing Yang JI ; Li SHI ; Yi Sheng SHI ; Xing Tong ZHOU ; Xiao Han YANG ; Sheng Shou HU
Chinese Journal of Cardiology 2023;51(4):393-399
Objective: To evaluate the long-term efficacy and safety of the implantable ventricular assist system EVAHEART I in clinical use. Methods: Fifteen consecutive patients with end-stage heart failure who received left ventricular assist device therapy in Fuwai Hospital from January 2018 to December 2021 were enrolled in this study, their clinical data were retrospectively analyzed. Cardiac function, liver and kidney function, New York Heart Association (NYHA) classification, 6-minute walk distance and quality of life were evaluated before implantation and at 1, 6, 12, 24 and 36 months after device implantation. Drive cable infection, hemolysis, cerebrovascular events, mechanical failure, abnormally high-power consumption and abnormal pump flow were recorded during follow up. Results: All 15 patients were male, mean average age was (43.0±7.5) years, including 11 cases of dilated cardiomyopathy, 2 cases of ischemic cardiomyopathy, and 2 cases of valvular heart disease. All patients were hemodynamically stable on more than one intravenous vasoactive drugs, and 3 patients were supported by preoperative intra aortic balloon pump (IABP). Compared with before device implantation, left ventricular end-diastolic dimension (LVEDD) was significantly decreased ((80.93±6.69) mm vs. (63.73±6.31) mm, P<0.05), brain natriuretic peptide (BNP), total bilirubin and creatinine were also significantly decreased ((3 544.85±1 723.77) ng/L vs. (770.80±406.39) ng/L; (21.28±10.51) μmol/L vs. (17.39±7.68) μmol/L; (95.82±34.88) μmol/L vs. (77.32±43.81) μmol/L; P<0.05) at 1 week after device implantation. All patients in this group were in NYHA class Ⅳ before implantation, and 9 patients could recover to NYHA class Ⅲ, 3 to class Ⅱ, and 3 to class Ⅰ at 1 month after operation. All patients recovered to class Ⅰ-Ⅱ at 6 months after operation. The 6-minute walk distance, total quality of life and visual analogue scale were significantly increased and improved at 1 month after implantation compared with those before operation (P<0.05). All patients were implanted with EVAHEART I at speeds between 1 700-1 950 rpm, flow rates between 3.2-4.5 L/min, power consumption of 3-9 W. The 1-year, 2-year, and 3-year survival rates were 100%, 87%, and 80%, respectively. Three patients died of multiple organ failure at 412, 610, and 872 d after surgery, respectively. During long-term device carrying, 3 patients developed drive cable infection on 170, 220, and 475 d after surgery, respectively, and were cured by dressing change. One patient underwent heart transplantation at 155 d after surgery due to bacteremia. Three patients developed transient ischemic attack and 1 patient developed hemorrhagic stroke events, all cured without sequelae. Conclusion: EVAHEART I implantable left heart assist system can effectively treat critically ill patients with end-stage heart failure, can be carried for long-term life and significantly improve the survival rate, with clear clinical efficacy.
Humans
;
Male
;
Adult
;
Middle Aged
;
Female
;
Heart Failure/complications*
;
Follow-Up Studies
;
Retrospective Studies
;
Heart-Assist Devices
;
Quality of Life

Result Analysis
Print
Save
E-mail