1.Longitudinal association between compulsive behaviour and smartphone addiction in middle school students
Chinese Journal of School Health 2025;46(5):638-641
Objective:
To explore the potential causal association between adolescent compulsive behaviour and smartphone addiction based on longitudinal data, so as to provide reference for the establishment of adolescent smartphone addiction interventions.
Methods:
A preliminary survey and follow-up were conducted on 8 907 middle and high school students in a district of Shenzhen in 2022 and 2023, respectively. Compulsive behaviours were measured by using the Mental Health Inventory for Middle School Students-60 Items (MMHI-60), smartphone addiction was assessed by using the Smartphone Addiction Scale-Short Version ( SAS- SV), and the associations between compulsive behaviours and smartphone addiction were analysed by using multilevel mixed-effects models and subgroup analyses.
Results:
Smartphone addiction detection rates among middle school students were significantly associated with genders, father s education level, mother s education level, study load subgroups, and whether or not they were single-parent families, and there were statistical differences ( χ 2=17.21-175.34, P <0.05). Students with compulsive behaviours were 2.98 times more likely to develop smartphone addiction than those without compulsive behaviours ( OR=2.98, 95%CI=2.77-3.22, P <0.05). Subgroup analysis of middle school students without smartphone addiction in the first year found that compulsive behaviours significantly predicted smartphone addiction ( OR= 1.76 , 95%CI=1.54-2.01, P <0.05).
Conclusion
There is a potential causal association between obsessive-compulsive behaviours and smartphone addiction in middle school students, and obsessive-compulsive behaviours in middle school students could significantly predicted the occurrence of smartphone addiction.
2.Association between QRS voltages and amyloid burden in patients with cardiac amyloidosis.
Jing-Hui LI ; Changcheng LI ; Yucong ZHENG ; Kai YANG ; Yan HUANG ; Huixin ZHANG ; Xianmei LI ; Xiuyu CHEN ; Linlin DAI ; Tian LAN ; Yang SUN ; Minjie LU ; Shihua ZHAO
Chinese Medical Journal 2024;137(3):365-367
3.An observational study on the treatment of chronic kidney disease stage 5 with resistant hypertension with sacubitril/valsartan
Yanhong NING ; Yuanshan XU ; Xiaohua LI ; Shihua LI ; Zhenhua YANG ; Yunhua LIAO ; Ling PAN
The Journal of Practical Medicine 2024;40(4):543-548
Objective The aim of this study was to evaluate the efficacy and side effects of sacubitril/valsartan in the treatment of patients with chronic kidney disease(CKD)at stage 5 with resistant hypertension,and to explore the cardiovascular benefits and security of medical in the patients.Methods Patients with CKD5 resistant hypertension diagnosed and treated in the First Affiliated Hospital of Guangxi Medical University from September 2020 to March 2022 were selected and divided into the observation group(treated with routine treatment of kidney disease at end-stage and sacubitril/valsartan)and control group(include droutine treatment of renal disease at end-stage and ACEI or ARB drugs)according to treatment strategy.The patients in both two groups were treated with adequate dialysis treatment and conventional drug treatment of renal disease at end-stage.The patients were followed up for at least 3 months,the clinical efficacy of three months after treated with sacubitril/valsartan was observed,and the efficacy indicators and security indicators and adverse cardiovascular events were observed,the occurrence of adverse effects during the period of drug use were compared with the control group.Results A total of 110 patients were included in this study and there were 55 cases in each group.There were no significant differences in gender,age,age of dialysis,etiology,dialysis mode and blood pressure between the two groups(P>0.05).The Systolic blood pressure(SBP),diastolic blood pressure(DBP),b-type urinary natriuretic peptide precursor(Pro-BNP)and cardiac function grade in the observation group after treatment was significantly decreased compared with before treatment.The left ventricular ejection fraction(LVEF)and the ratio of LVEF<50%in the observation group was significantly reduced after treatment(P<0.05).SBP,DBP and Pro-BNP decreased 3 months after treatment compared with the baseline before treatment,and improved significantly in the first month after treatment(P<0.05).The decrease of DBP and BNP before and after treatment was significantly different between the two groups,and the decrease of DBP and BNP was more significant in the observation group(P<0.05).The difference of LVEF and left ventricular end diastolic diameter(LVEDD)between the two groups before and after treatment was statistically significant,and the improvement was more obvious in the observation group(P<0.05).There were no significant differences in the safety indicators of serum potassium,estimated glomerular filtration rate(eGFR)and liver function between two groups before and after treatment(P>0.05).In terms of adverse reactions,only 1 case in the control group developed hyperkalemia within 3 months of follow-up,and no hypotension or other adverse reactions occurred in the two groups.Conclusions The treatment of patients with CKD stage 5 hypertension with sacubitril/valsartan has obvious cardiovascular benefits.Sacubitril/Valsartan has efficacy in lowering blood pressure,improving cardiac function and reducing volume load,with less adverse events and higher safety than control group.
4.Relationship between protein-energy wasting and parathyroid hormone levels in patients undergoing maintenance hemodialysis
Qing LI ; Shihua SHEN ; Weile WANG ; Jingjing LIU ; Yiya WANG ; Wei ZHU ; Jing YANG
Chinese Journal of Primary Medicine and Pharmacy 2024;31(4):553-559
Objective:To investigate the relationship between protein-energy wasting (PEW) and parathyroid hormone (PTH) levels in patients undergoing maintenance hemodialysis.Methods:A cross-sectional study was conducted to enroll 150 adult patients undergoing maintenance hemodialysis at The Third Affiliated Hospital of Anhui Medical University from January 2022 to May 2023. These patients were categorized into four groups based on their PTH levels: low PTH group (< 150 ng/L), standard PTH group (150-300 ng/L), very high PTH group (300-600 ng/L), and extreme high PTH group (> 600 ng/L). The diagnosis of PEW was determined using the diagnostic criteria proposed by the International Society of Renal Nutrition and Metabolism (ISRNM). Logistic regression analysis was performed to investigate the association between PEW and PTH levels.Results:Among the 150 patients undergoing maintenance dialysis, 52 (34.7%) were diagnosed with PEW. The prevalence of PEW was significantly higher in the low PTH group compared with the standard, very high, and extreme high PTH groups ( χ2 = 20.64, all P < 0.05). Univariate logistic regression analysis revealed a strong association between low PTH levels ( OR = 13.810, 95% CI: 2.907-65.603, P = 0.001) and an increased risk of PEW. The risk of PEW in the low PTH group was 13.810 times higher than that in the extreme high PTH group. Multivariate logistic regression analysis further confirmed that low PTH levels ( OR = 19.891, 95% CI: 1.810-218.620, P = 0.014) and low C-reactive protein levels ( OR = 1.056, 95% CI: 1.015-1.099, P = 0.007) were independently associated with an increased risk of PEW. Higher hemoglobin levels ( OR = 0.959, 95% CI: 0.931-0.988, P = 0.005) and a larger middle upper arm circumference ( OR = 0.544, 95% CI: 0.338-0.875, P = 0.012) were independently associated with a reduced risk of PEW. The risk of PEW in the low PTH group was 19.891 times higher than that in the extreme high PTH group. However, there was no significant difference in the risk of PEW in the standard and very high PTH groups compared with the extreme high PTH group (both P > 0.05). Conclusion:The risk of PEW is markedly elevated in patients with low PTH levels, emphasizing the importance of clinical attention to the prevention and treatment of low PTH levels. Addressing this issue may hold great value in reducing the risk of PEW.
5.Magnetic resonance left ventricular hemodynamic analysis: a normal value study of two methods
Huaying ZHANG ; Wenjing YANG ; Jing XU ; Di ZHOU ; Yining WANG ; Leyi ZHU ; Mengdi JIANG ; Gang YIN ; Shihua ZHAO ; Minjie LU
Journal of Chinese Physician 2024;26(1):12-17
Objectives:To analyze the consistency of evaluating left ventricular hemodynamics (HDF) based on single plane and multi plane cine sequences of magnetic resonance mitral valve orifice.Methods:A prospective study was conducted on 48 healthy adults, and two methods were used to measure the mitral valve diameter and calculate HDF parameters. The first method was to measure the diameter of the mitral valve opening in the left ventricular three chamber cine sequence; The second method is to measure the mitral valve diameter using cine sequences of two chamber, three chamber, and four chamber hearts, and then take the average value. Paired t-tests were used to compare the differences in HDF measured by two methods, and Pearson correlation coefficient ( r), intra group correlation coefficient ( ICC), and Bland-Altman analysis were used to test the consistency and reproducibility of the two methods. Results:The root mean square (RMS) of longitudinal HDF calculated using single plane and multi plane mitral valve diameters were [(17.28±4.41)% vs (17.21±4.61)%] ( P=0.379) for the entire cardiac cycle, [(21.45±5.54)% vs (21.49±5.68)%] ( P=0.646) for systolic phase, and [(12.78±4.10)% vs (12.54±4.24)%] ( P=0.106) for diastolic phase, respectively. The difference in the calculation results of HDF parameters related to ventricular function was not statistically significant (all P>0.05), and there was good consistency ( r=0.924-0.996, ICC=0.924-0.995). The two HDF parameters related to atrial function were sensitive to the measurement method of mitral valve orifice diameter [RMS of longitudinal HDF during active atrial emptying: (3.26±1.51)% vs (3.32±1.55)%, P=0.006; longitudinal HDF pulse during active atrial emptying: (-2.60±1.28)% vs (-2.76±1.30)%, P<0.001]. Conclusions:The ventricular function related HDF parameters obtained from the analysis of mitral valve orifice diameter using single plane and multi plane methods have good consistency, and can be evaluated using relatively simple single plane methods for left ventricular HDF.
6.Pay more attention to cardiac MR in diagnosis and differential diagnosis of hypertrophic cardiomyopathy(HCM)and HCM phenocopies
Chinese Journal of Interventional Imaging and Therapy 2024;21(10):577-579
Early and accurate diagnosis and differential diagnosis of hypertrophic cardiomyopathy(HCM)and HCM phenocopies is of great clinical significances for evaluating and treating HCM,which is also a major clinical challenge at present.Multimodal cardiac MR(CMR)might provide"one-stop"evaluation on cardiac morphology,function,histological and strain characteristics,hence having unique advantages for evaluating HCM and HCM phenocopies.
7.Left Atrial Myocardial Fibrosis Assessment by 3D High-resolution Late Gadolinium Enhancement MRI in Patients With Atrial Fibrillation:a Feasibility Study
Leyi ZHU ; Shuo YUAN ; Yining WANG ; Kang AN ; Wenjing YANG ; Haojie LI ; Gang YIN ; Shihua ZHAO ; Minjie LU ; Zhe ZHENG
Chinese Circulation Journal 2024;39(7):703-709
Objectives:To investigate the clinical feasibility of three-dimensional(3D)high-resolution late gadolinium enhancement(LGE)MRI in accessing left atrial myocardial fibrosis in patients with atrial fibrillation(AF). Methods:A total of 34 AF patients referred for hybrid surgical ablation were retrospectively enrolled in this study.3D-LGE-MRI images were acquired by Siemens 3.0 T machine and analyzed by ADAS post-processing software by two experienced radiologists to obtain parameters such as the area and the area percentage of LGE.Regional analysis was performed by one of the two radiologists at ten left atrial segments.The Kappa test was used to assess the agreement for scoring image quality,and the interclass correlation coefficient(ICC)was used to evaluate the interobserver agreement of LGE parameters.The parameters of left atrial morphology,area(and area percentage)of LGE,and location of LGE were compared between patients with persistent AF and paroxysmal AF. Results:Images of all 34 patients were considered to have diagnostic value.The scores of the overall image quality and the clarity of the left atrial wall evaluated by two radiologists were(2.88±0.64)points and(3.26±0.75)points(radiologist 1),(2.97±0.58)points and(3.24±0.70)points(radiologist 2),respectively.The corresponding Kappa values were 0.724 and 0.859.Both the area and the area percentage of LGE showed good consistency among observers,and the ICCs were 0.969 and 0.950,respectively.The difference in the area of LGE and the area percentage of LGE between patients with paroxysmal and persistent atrial fibrillation was similar(both P>0.05).Compared with patients with paroxysmal AF,patients with persistent AF had a higher Utah stage and more severe myocardial fibrosis in the right inferior pulmonary vein antrum and the left atrial septum(all P<0.05). Conclusions:3D high-resolution LGE-MRI provides a non-invasive way to visualize and quantify left atrial myocardial fibrosis.The extent of left atrial fibrosis in patients with persistent AF is more severe than that in patients with paroxysmal AF,with a preferential distribution in the right inferior pulmonary vein antrum and the left atrial septum.
8.Preliminary clinical application of total free-breathing cardiac MR examination
Kai YANG ; Gang YIN ; Jing AN ; Xinling YANG ; Tian LAN ; Shihua ZHAO ; Minjie LU
Chinese Journal of Medical Imaging Technology 2024;40(8):1183-1188
Objective To observe the clinical application value of total free-breathing cardiac MR(CMR)examination preliminarily.Methods Two patients who underwent CMR scanning under free-breathing state,including cine,motion correction T1 and T2 mapping,blood flow imaging,and late gadolinium enhancement scanning were retrospectively enrolled,and the qualities of the above images were evaluated and compared with that of conventional CMR images under breath-holding state.Results No significant difference of imaging quality was found between total free-breathing and conventional breath-holding CMR.The differences of left ventricular ejection fraction,cardiac output,left ventricular end-diastolic volume index and left ventricular mass measured based on CMR images under different breath conditions were limited.Conclusion Total free-breathing CMR was feasible in clinical practice,which could provide"one-stop"evaluation of cardiac structure,function and myocardial histological characteristics,hence having promising clinical prospects.
9.Evaluation of left and right ventricular systolic function by cardiac MR compressed sensing ultrafast cine sequence
Gang YIN ; Wenhao DONG ; Xiuyu CHEN ; Xinling YANG ; Jing AN ; Jianing PANG ; Yan ZHANG ; Minjie LU ; Shihua ZHAO
Chinese Journal of Radiology 2023;57(3):300-305
Objective:To explore the clinical value of cardiac MR (CMR) compression sensing (CS) ultrafast cine sequence in evaluating left and right ventricular systolic function by comparing with traditional segmented acquisition cine sequence (Seg).Methods:Twenty-seven patients with various heart disease were prospectively included. Seg, breath holding CS (bhCS) and free breathing CS (fbCS) covering the left and right ventricles using multi slices in short axis were performed in random order. Friedman test was used to evaluate the overall image quality (grade 1-5 score), blood pool myocardial signal ratio (BMC) and edge sharpness under different methods. Biventricular end diastolic volume (EDV), end systolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular myocardial mass (Mass) were measured for all three methods. The agreements of the functional measurements between bhCS and Seg (gold standard), and between fbCS and Seg were analyzed by Bland-Altman, and the correlation test was performed.Results:Twenty-four patients with diagnostic images(overall image quality score≥2) for all three methods were included in further analysis. The total imaging time of Seg, bhCS and fbCS decreased successively[375.0 (332.0, 405.6) vs. 50.0 (47.8, 53.7) vs. 20.0 (17.8, 23.7) s, χ 2=48.00, P<0.001]. The overall image quality of fbCS was slightly lower than that of Seg ( Z=-2.67, P=0.023), and there was no difference between Seg and bhCS ( Z=-1.44, P=0.447), bhCS and fbCS ( Z=1.23, P=0.660). There were no differences in edge sharpness (χ 2=1.08, P=0.582) and BMC (χ 2=0.58, P=0.747) for three methods. Bland-Altman polts showed good agreement for biventricular functional measurements between bhCS and Seg, and between fbCS and Seg. All functional measurements of bhCS and fbCS were highly correlated with that of seg ( r>0.96, P<0.001). Conclusions:Compared with traditional sequences, CS ultrafast cine sequences can save scanning time and provide similar image quality. No matter whether breath holding or not, the cardiac functional results of CS sequence and traditional cine sequence have good agreement and high correlation.
10.Study on the damage of primary branches of the Glisson system in the hepatic portal by argon plasma coagulation with different spraying time
Xiangyu PENG ; Shihua LIU ; Yuyang GUO ; Xinghua HUANG ; Jianyong LIU ; Yang CHENG ; Huanzhang HU
Chinese Journal of Hepatobiliary Surgery 2023;29(5):364-369
Objective:To investigate the effect of different spray-coagulation time of argon plasma coagulation (APC) injury on the Glisson system primary branche(G1) in the hepatic portal of pigs.Methods:Fifty clean healthy domestic pigs (27 females and 23 males, aged 7 to 14 months) were selected, with the body weighted (100.0±9.5) kg. They were randomly divided into five groups (A, B, C, D, and E), with 10 pigs in each group. G1 models were made and sprayed by APC for 1, 2, 3, 4, and 5 seconds. The damage, maximum damage area, maximum damage depth, and damage of the three branches of the Glisson system (the first branches of the portal vein, intrahepatic bile duct, and hepatic artery) were compared among the groups. The pigs were divided into two groups based on whether the three branches were damaged or not: the three-branch damage group ( n=23) and the control group ( n=27). The maximum damage area and maximum damage depth were compared between the two groups. Results:After the APC spraying, circular or elliptical damage appeared on the surface of the G1, with changes such as yellow-brown color, brown color, charred appearance, and defects. Under the microscope, G1 capsule was found to be deficient, the fibrous tissue beneath the capsule was ruptured, and the structures of small blood vessels and small bile ducts were incomplete. " Burn marks" and damage to the three branches of the Glisson system in G1 were also observed, and the damage was more severe at the center of the spray-coagulation. As the spray-coagulation time increased, the maximum damage area of the G1 model also increased, and the two were positively correlated ( r=0.90, P<0.001). The maximum damage depth was also positively correlated with spray-coagulation time ( r=0.97, P<0.001). The numbers of pigs with damage to the three branches of the Glisson system in Groups A-E were 0, 2, 5, 6, and 10, respectively, and the number of pigs with damage increased with the spray-coagulation time. In the three-branch damage group, the spray-coagulation time, maximum damage area, and maximum damage depth were all higher than those in the control group (without three-branch damage), and the differences were statistically significant (all P<0.05). Conclusion:The degree of damage to G1 caused by APC is positively correlated with the spray-coagulation time, and damage to the three branches of the Glisson system in G1 is related to the maximum damage area, maximum damage depth, and APC spray-coagulation time.


Result Analysis
Print
Save
E-mail