1.Animal models of femoral bone defects:preparation status and characteristics
Shibo ZHOU ; Jianbin GUAN ; Xing YU ; He ZHAO ; Yongdong YANG ; Tao LIU
Chinese Journal of Tissue Engineering Research 2024;28(4):633-638
BACKGROUND:The repair and clinical outcome of bone defects remains a hot and difficult area of clinical research,which is a common problem that plagues clinicians.Constructing suitable,reproducible and infinitely close to clinical animal experimental models and their scientific evaluation are essential for further clinical treatment of related diseases. OBJECTIVE:To retrospectively analyze the preparation methods and characteristics of common animal models of femoral bone defects and to assess their strengths and weaknesses,thereby providing some reference for relevant researchers to select appropriate animal models of femoral bone defects. METHODS:PubMed,Web of Science,Medline,and CNKI were retrieved for relevant literature published from January 1,2000 to August 1,2022.The keywords were"bone defect,bone,bones,defect,defects,defective,animal model,animal,model,laboratory,laboratory animal,animal laboratory"in English and"bone defect,animal model,experiment"in Chinese. RESULTS AND CONCLUSION:Twenty-seven randomized controlled animal experiments involving rats,mice,New Zealand rabbits,and sheep were included,analyzed and assessed.The most common types of bone defects were cylindrical bone defects and segmental osteotomy bone defects,generally found in the middle and distal femur.These models are mostly used to evaluate the effects of bone repair materials,drugs,drug-loaded active substances and physical therapy on bone defect repair and explore defect healing mechanisms,particularly the weight-bearing bone defect repair mechanism.Different defect kinds and femoral bone defect ranges have been found in different animal experiments.Researchers can select the suitable animal model and bone defect type based on the goal of the experiment and then set an acceptable bone defect value.Current studies have shown that cylindrical and segmental osteotomy-induced bone defects,mainly in the distal and middle femur,are mostly used in the animal models of femoral bone defects and that the surgical methods and postoperative management are more mature and operable to provide mature experimental animal models.In terms of cylindrical bone defects,rats and New Zealand rabbits are more suitable,whereas segmental osteotomy has no special requirements and all types of animals can meet the experimental requirements.
2.Molecular biological mechanism of acquired heterotopic ossification
Yang XIONG ; Shibo ZHOU ; Xing YU ; Lianyong BI ; Jizhou YANG ; Fengxian WANG ; Yi QU ; Yongdong YANG ; Dingyan ZHAO ; He ZHAO ; Ziye QIU ; Guozheng JIANG
Chinese Journal of Tissue Engineering Research 2024;28(30):4881-4888
BACKGROUND:Heterotopic ossification is a dynamic growth process.Diverse heterotopic ossification subtypes have diverse etiologies or induction factors,but they exhibit a similar clinical process in the intermediate and later phases of the disease.Acquired heterotopic ossification produced by trauma and other circumstances has a high incidence. OBJECTIVE:To summarize the molecular biological mechanisms linked to the occurrence and progression of acquired heterotopic ossification in recent years. METHODS:The keywords"molecular biology,heterotopic ossification,mechanisms"were searched in CNKI,Wanfang,PubMed,Embase,Web of Science,and Google Scholar databases for articles published from January 2016 to August 2022.Supplementary searches were conducted based on the obtained articles.After the collected literature was screened,131 articles were finally included and summarized. RESULTS AND CONCLUSION:(1)The occurrence and development of acquired heterotopic ossification is a dynamic process with certain concealment,making diagnosis and treatment of the disease difficult.(2)By reviewing relevant literature,it was found that acquired heterotopic ossification involves signaling pathways such as bone morphogenetic protein,transforming growth factor-β,Hedgehog,Wnt,and mTOR,as well as core factors such as Runx-2,vascular endothelial growth factor,hypoxia-inducing factor,fibroblast growth factor,and Sox9.The core mechanism may be the interaction between different signaling pathways,affecting the body's osteoblast precursor cells,osteoblast microenvironment,and related cytokines,thereby affecting the body's bone metabolism and leading to the occurrence of acquired heterotopic ossification.(3)In the future,it is possible to take the heterotopic ossification-related single-cell osteogenic homeostasis as the research direction,take the osteoblast precursor cells-osteogenic microenvironment-signaling pathways and cytokines as the research elements,explore the characteristics of each element under different temporal and spatial conditions,compare the similarities and differences of the osteogenic homeostasis of different types and individuals,observe the regulatory mechanism of the molecular signaling network of heterotopic ossification from a holistic perspective.It is beneficial to the exploration of new methods for the future clinical prevention and treatment of heterotopic ossification.(4)Meanwhile,the treatment methods represented by traditional Chinese medicine and targeted therapy have become research hotspots in recent years.How to link traditional Chinese medicine with the osteogenic homeostasis in the body and combine it with targeted therapy is also one of the future research directions.(5)At present,the research on acquired heterotopic ossification is still limited to basic experimental research and the clinical prevention and treatment methods still have defects such as uncertain efficacy and obvious side effects.The safety and effectiveness of relevant targeted prevention and treatment drugs in clinical application still need to be verified.Future research should focus on clinical prevention and treatment based on basic experimental research combined with the mechanism of occurrence and development.
3.Immediate implantation of simple taper retentive implants in chronic apical infected teeth in the posterior region:a 5-year clinical observation
Xu ZHANG ; Shibo WEI ; Fei YU ; Hao WU ; Liangwei CAO ; Ning CAO ; Hongwu WEI ; Shuigen GUO
West China Journal of Stomatology 2024;42(6):764-772
Objective This study aims to evaluate the mid-and long-term clinical efficacies of simple taper retentive implants for immediate placement in chronic apical infected teeth in the posterior region.Methods A total of 36 pa-tients with 41 simple taper retentive implants were included in the study conducted.These patients underwent immediate implant treatment for teeth with chronic apical infection in the posterior region.The soft and hard tissues surrounding the implants were assessed and documented over a period of 5 years following the completion of crown restoration.Re-sults During the 5 years follow-up period,one implant failed with mobility,and the implant survival rate was 97.6%.The mean marginal bone resorption was(-0.74±1.03)mm from the immediate post-implant placement to the immediate post-crown restoration,and the difference in marginal bone heights between the two time points was statistically signifi-cant(P<0.05).The mean marginal bone resorption was(-0.21±0.70)mm from the immediate post-crown restoration to the 5-year post-crown restoration,and the difference in marginal bone height between the two time points was not statisti-cally significant(P>0.05).No significant difference(P>0.05)was observed in bone resorption between mesial and distal,maxillary and mandibular,different tooth posi-tions,and different implant lengths.The soft tissue sur-rounding the implants remained healthy at the 5 years follow-up period,one implant exhibited peri-implantitis,and no mechanical complications were observed.The overall satisfaction of patients was good.Conclusion Immediate place-ment of simple taper retentive implants after thorough debridement of chronic infected alveolar socket in the posterior re-gion can achieve good mid-and long-term clinical outcomes after 5 years of loading.The soft and hard tissues were maintained in a steady state,which expanded the indications for immediate implantation.
4.Artificial intelligence knowledge graph and image classification for quality control of chest posterior-anterior position X-ray radiograph
Qian WANG ; Liangliang SONG ; Xiao HAN ; Ming LIU ; Biao ZHANG ; Shibo ZHAO ; Zongyun GU ; Lili HUANG ; Chuanfu LI ; Xiaohu LI ; Yongqiang YU
Chinese Journal of Medical Imaging Technology 2024;40(6):922-927
Objective To observe the value of artificial intelligence(AI)knowledge graph and image classification for quality control(QC)of chest posterior-anterior position X-ray radiograph(abbreviated as chest film).Methods Totally 9 236 chest films from 595 medical institutions in Anhui province imaging cloud platform were retrospectively enrolled.QC knowledge graph containing 21 classification labels were constructed.Firstly,QC of chest films based on the above knowledge graph were performed by 10 technicians for 2 rounds of single person and 1 round of multi person,and the results were recorded as A,B and C,respectively.Then AI algorithms were used to classify and evaluate based on knowledge graph,and the result was recorded as D.Finally,a QC expert reviewed results C and D to determine the final QC results and taken those as references to analyze the efficiency of the above 4 QC.Results The area under the curve(AUC)of AI algorithm for QC of chest films were all ≥0.780,with an average value of 0.939.The average precision of QC for chest films of A,B,C and D was 81.15%,85.47%,91.65%and 92.21%,respectively.Conclusion AI knowledge graph and image classification technology could be effectively used for QC of chest posterior-anterior position X-ray radiograph.
5.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
7.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
8.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
9.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
10.A rare case of dicentric ring chromosome and derivative ring chromosome Chimera.
Junzhen ZHU ; Xiaoping YU ; Xiaofeng QI ; Qinying CAO ; Wenshuang ZHU ; Dan YANG ; Haoyu ZHANG ; Zhanyun SONG ; Shibo WANG ; Cuixia WANG
Chinese Journal of Medical Genetics 2022;39(5):534-536
OBJECTIVE:
Utilize high-resolution chromosome analysis and microarray detection to determine the genetic etiology of infertility of a 32-year old female patient.
METHODS:
The peripheral blood of the patient was cultured for high-resolution chromosome G and C banding karyotype analysis, and then 750K SNP-Array chip detection was performed.
RESULTS:
Karyotype analysis results showed that the patient's karyotype was 45,XX,-13 [7]/46,XX,r(13) (p13q34) [185]/46,XX,dic r(13;13)(p13q34;p13q34) [14]/ 47,XX,+der(13;13;13;13) (p13q34;p13q34;p13q34; p13q34), dic r(13;13) [1]/ 46,XX [3]. The microarray results showed that the patient had a 3.3 Mb deletion in the 13q34 segment of chromosome 13, which may be related to infertility.
CONCLUSION
Infertility of the patient reported in this article may be related to the deletion of chromosome segment (13q34-qter).
Adult
;
Chimera
;
Chromosome Banding
;
Chromosome Deletion
;
Chromosome Disorders/genetics*
;
Dacarbazine
;
Female
;
Humans
;
Infertility/genetics*
;
Ring Chromosomes

Result Analysis
Print
Save
E-mail