1.Progress on antisense oligonucleotide in the field of antibacterial therapy
Jia LI ; Xiao-lu HAN ; Shi-yu SONG ; Jin-tao LIN ; Zhi-qiang TANG ; Zeng-ming WANG ; Liang XU ; Ai-ping ZHENG
Acta Pharmaceutica Sinica 2025;60(2):337-347
With the widespread use of antibiotics, drug-resistant bacterial infections have become a significant threat to human health. Finding new antibacterial strategies that can effectively control drug-resistant bacterial infections has become an urgent task. Unlike small molecule drugs that target bacterial proteins, antisense oligonucleotide (ASO) can target genes related to bacterial resistance, pathogenesis, growth, reproduction and biofilm formation. By regulating the expression of these genes, ASO can inhibit or kill bacteria, providing a novel approach for the development of antibacterial drugs. To overcome the challenge of delivering antisense oligonucleotide into bacterial cells, various drug delivery systems have been applied in this field, including cell-penetrating peptides, lipid nanoparticles and inorganic nanoparticles, which have injected new momentum into the development of antisense oligonucleotide in the antibacterial realm. This review summarizes the current development of small nucleic acid drugs, the antibacterial mechanisms, targets, sequences and delivery vectors of antisense oligonucleotide, providing a reference for the research and development of antisense oligonucleotide in the treatment of bacterial infections.
2.Study on the influential factors of blood concentration for duloxetine based on therapeutic drug monitoring
Yang LUN ; Liguang DUAN ; Feiyue AN ; Ran FU ; Jing YU ; Chaoli CHEN ; Mengqiang ZHAO ; Shi SU ; Yang SONG ; Jiaqi WANG ; Yuhang YAN ; Chunhua ZHOU
China Pharmacy 2025;36(6):727-731
OBJECTIVE To explore the main factors influencing the blood concentration of duloxetine, and provide a scientific basis for the individualized use of duloxetine. METHODS Retrospective analysis was conducted on 434 inpatients with depressive disorders at the First Hospital of Hebei Medical University, who were treated with duloxetine and underwent blood concentration monitoring between January 2022 and April 2024. The study examined the impact of various factors, including gender, age, body mass index (BMI), gene phenotypes, combined medication, drug type (original/generic), and genotyping results of gene single nucleotide polymorphism loci, on blood concentration and the concentration-to-dose (C/D) after dose adjustment. RESULTS The blood concentration of duloxetine was 76.65 (45.57, 130.31) ng/mL, and C/D was 0.96 (0.63, 1.60) ng·d/(mL·mg). The blood concentration of duloxetine was positively correlated with the daily dose of administration (R2=0.253 7, P<0.001). Blood concentration of duloxetine in 38.94% of patients exceeded the recommended range specified in the guidelines. Gender, age, BMI, combined use of CYP2D6 enzyme inhibitors, and CYP2D6 and CYP1A2 phenotypes had significant effects on C/D of duloxetine (P<0.05). CONCLUSIONS The patient’s age, gender, BMI, combined medication, and genetic phenotypes are closely related to the blood concentration of duloxetine.
3.Synthesis and evaluation for anti-HCoV-OC43 activity of novel aloperine derivatives with different core structures
Run-ze MENG ; Yue GONG ; Yu-long SHI ; Kun WANG ; Zong-gen PENG ; Dan-qing SONG
Acta Pharmaceutica Sinica 2024;59(2):404-412
In this study, we designed and synthesized 12 novel aloperine derivatives with different core structures. Among them, compound
4.The impact of programming optimization for atrioventricular synchrony after Micra AV leadless pacemakers implantation
Ze ZHENG ; Yu-Chen SHI ; Song-Yuan HE ; Shao-Ping WANG ; Shi-Ying LI ; Shu-Juan CHENG ; Jing-Hua LIU
Chinese Journal of Interventional Cardiology 2024;32(2):71-75
Objective To analyze the atrioventricular synchronization rate after implantation of Micra AV leadless pacemaker,and the impact of postoperative programming optimization on atrioventricular synchronization rate.Methods A prospective cohort study was conducted to select patients with complete atrioventricular block who underwent Micra AV leadless pacemaker implantation at Beijing Anzhen Hospital from August 2022 to June 2023.Programming optimization were performed at 1 week,1 month,and 3 months postoperatively,and atrioventricular synchronization rate,electrical parameters,and echocardiography were recorded.Results A total of 68 patients with complete atrioventricular block implanted with Micra AV were selected,with an average age of(68.2±9.7)years,including 47 males(69.1%).All patients were successfully implanted with Micra AV,and there were no serious postoperative complications;The average threshold,sense,and impedance parameters were stable during 1 week,1 month,and 3 months after the procedure;There was no significant difference in the EF value of postoperative echocardiography(P=0.162);The average atrioventricular synchronization rates at 1 week,1 month,and 3 months postoperatively were(75.2%vs.83.8%vs.91.6%,P=0.001).Conclusions As an mechanical atrial sensing,Micra AV requires personalized adjustment of relevant parameters;Postoperative follow-up programming optimization plays an important role in the atrioventricular synchronization and comfort level in patients with complete atrioventricular block after implantation of Micra AV leadless pacemaker.
5.Vascular suture, closure and occlusion devices at femoral artery puncture hemostasis after neuro-intervention: a clinical comparative study
Shuailong SHI ; Shuhai LONG ; Sun YU ; Chengcheng SHI ; Ji MA ; Renying MIAO ; Yan SONG ; Xinwei HAN ; Tengfei LI
Chinese Journal of Radiology 2024;58(1):71-78
Methods:From February 2018 to January 2022, the clinical data of 1 123 patients who underwent Starclose vascular closure device, Angio-Seal and Exoseal vascular occlusion devices and Perclose ProGlide vascular suture device at femoral artery puncture hemostasis after neuro-intervention, in the Department of Interventional Radiology (Eastern District), The First Affiliated Hospital of Zhengzhou University, were retrospectively analyzed. The patients were divided into three groups based on the intervention method: the closure group (Starclose, n=271), the occlusion group (Angio-Seal, n=327 and Exoseal, n=352) and the suture group (ProGlide, n=173). Next, the hemostatic efficacy and complications associated with the three devices were analyzed and compared. Additionally, regression analysis was conducted to identify any relevant factors that may contribute to complications. Results:Three vascular hemostatic devices demonstrated effective hemostasis and the success rate were 92.6% in the closure group (Starclose), 93.4% in the occlusion group (Angio-Seal 93.0% and Exoseal 93.8%) and 89.6% in the suture group (ProGlide). There was no statistically significant difference( χ2=3.026, P=0.388). Single or multiple complications were observed in 102 patients (9.1%), including local oozing (16 cases in the closure group, 39 cases in the occlusion group, 13 cases in the suture group), local hematoma (14 cases in the closure group, 31 cases in the occlusion group, 11 cases in the suture group), pseudoaneurysm (13 cases in the closure group, 35 cases in the occlusion group, 10 cases in the suture group), local infection (2 cases in the closure group, 3 cases in the occlusion group, 1 case in the suture group). There were no statistically significant differences ( P>0.05). Moreover, serious complications such as femoral artery occlusion, embolus shedding and permanent nerve injury weren′t observed in the three groups. Multivariate logistic regression analysis revealed that overweight ( OR=1.562,95% CI 1.023—2.385, P=0.039), femoral artery with calcified plaque ( OR=1.934,95% CI 1.172-3.189, P=0.010), combined use of multiple antiplatelet drugs ( OR=1.769,95% CI 1.103—2.839, P=0.018), use of an 8F sheath( OR=2.824,95% CI 1.406—5.671, P=0.004) and the operator′s proficiency ( OR=0.508,95% CI 0.328—0.788, P=0.002) were the independent factors influencing complications, of which the first four were identified as risk-promoting factors for complications while the operator′s rich experience and high proficiency were the protective factors. Conclusions:Three hemostatic devices demonstrate effective hemostasis and comparable rates of complications at femoral artery puncture hemostasis after neuro-intervention. Overweight, femoral artery with calcified plaque, combined use of multiple antiplatelet drugs, use of an 8 F sheath and the operator′s proficiency were independent factors influencing complications.Ojective:To investigate the efficacy and complications associated with vascular suture, closure and occlusion devices at femoral artery puncture hemostasis after neuro-intervention.
6.Investigation and analysis of the current status of transjugular intrahepatic portosystemic shunt treatment for portal hypertension in China
Haozhuo GUO ; Meng NIU ; Haibo SHAO ; Xinwei HAN ; Jianbo ZHAO ; Junhui SUN ; Zhuting FANG ; Bin XIONG ; Xiaoli ZHU ; Weixin REN ; Min YUAN ; Shiping YU ; Weifu LYU ; Xueqiang ZHANG ; Chunqing ZHANG ; Lei LI ; Xuefeng LUO ; Yusheng SONG ; Yilong MA ; Tong DANG ; Hua XIANG ; Yun JIN ; Hui XUE ; Guiyun JIN ; Xiao LI ; Jiarui LI ; Shi ZHOU ; Changlu YU ; Song HE ; Lei YU ; Hongmei ZU ; Jun MA ; Yanming LEI ; Ke XU ; Xiaolong QI
Chinese Journal of Radiology 2024;58(4):437-443
Objective:To investigate the current situation of the use of transjugular intrahepatic portosystemic shunt (TIPS) for portal hypertension, which should aid the development of TIPS in China.Methods:The China Portal Hypertension Alliance (CHESS) initiated this study that comprehensively investigated the basic situation of TIPS for portal hypertension in China through network research. The survey included the following: the number of surgical cases, main indications, the development of Early-TIPS, TIPS for portal vein cavernous transformation, collateral circulation embolization, intraoperative portal pressure gradient measurement, commonly used stent types, conventional anticoagulation and time, postoperative follow-up, obstacles, and the application of domestic instruments.Results:According to the survey, a total of 13 527 TIPS operations were carried out in 545 hospitals participating in the survey in 2021, and 94.1% of the hospital had the habit of routine follow-up after TIPS. Most hospitals believed that the main indications of TIPS were the control of acute bleeding (42.6%) and the prevention of rebleeding (40.7%). 48.1% of the teams carried out early or priority TIPS, 53.0% of the teams carried out TIPS for the cavernous transformation of the portal vein, and 81.0% chose routine embolization of collateral circulation during operation. Most of them used coils and biological glue as embolic materials, and 78.5% of the team routinely performed intraoperative portal pressure gradient measurements. In selecting TIPS stents, 57.1% of the hospitals woulel choose Viator-specific stents, 57.2% woulel choose conventional anticoagulation after TIPS, and the duration of anticoagulation was between 3-6 months (55.4%). The limitation of TIPS surgery was mainly due to cost (72.3%) and insufficient understanding of doctors in related departments (77.4%). Most teams accepted the domestic instruments used in TIPS (92.7%).Conclusions:This survey shows that TIPS treatment is an essential part of treating portal hypertension in China. The total number of TIPS cases is far from that of patients with portal hypertension. In the future, it is still necessary to popularize TIPS technology and further standardize surgical indications, routine operations, and instrument application.
7.Four microcolumn agglutination anti-human globulin cards in unexpected antibody screening results: a comparative analysis
Ke SONG ; Chunya MA ; Lihui FU ; Pan XIAO ; Hongmei SHI ; Yang YU
Chinese Journal of Blood Transfusion 2024;37(12):1405-1411
[Abstract] [Objective] To analyze the detection ability of one imported and three domestic microcolumn agglutination anti-human globulin cards in unexpected antibody screening test. [Methods] A total of 104 positive samples from antibody screening test conducted at our hospital from July to September 2022 were selected. Microcolumn agglutination antiglobulin tests were performed in parallel with antibody screening tests using one imported card (A Card) and three domestic cards (B, C and D Cards ) to analyze the differences in the sensitivity, specificity and agglutination intensity scores. [Results] The sensitivity of the four anti-human globulin cards was as follows: D card 88.51% (131/148) > C card 83.22% (124/149) > B card 81.63% (120/147) > A card 80.54% (120/149); the specificity was A card 97.79% (133/136) > B card 95.65% (132/138) > D card 95.62% (131/137) > C card 93.38% (127/136); and the average agglutination intensity score (points) was D card 214.57 > C card 191.90 > A Card 179.69 > B Card 175.83, and the H value of Kruskal-Wallis test was 7.221, with no statistically significant difference (P > 0.05). Among them, C card was prone to false positives, accounting for 3.16% (9/285), and A card was prone to false negatives, accounting for 10.18% (29/285). [Conclusion] There were differences in the detection ability of anti-human globulin cards of different manufacturers, and some domestic cards have higher detection performance than imported cards. It is recommended to use anti-human globulin cards of two manufacturers routinely in clinical practice, that is, to use cards with high detection sensitivity for antibody screening tests to avoid antibody missed detection as much as possible, and to use cards with high specificity for cross-matching blood tests to avoid delays in transfusion due to false positives, which could hinder transfusion treatment.
8.Bioequivalence of ibuprofen arginine granules in healthy Chinese volunteers
Pan-Pan SHI ; Fen SHEN ; Li-Mei SONG ; Feng-Li ZHAO ; Wang LI ; Wei-Chen ZHANG ; Yu TIAN
The Chinese Journal of Clinical Pharmacology 2024;40(1):107-111
Objective To evaluate the bioequivalence and safety of ibuprofen arginine granules test and reference formulations in Chinese healthy volunteers under fasting and postprandial conditions,and to provide evidence for consistency evaluation and clinical application of the drugs.Methods A single-center,single-dose,randomized,open-label,fasting and postprandial,two-period,two-crossover trial design was used.Twenty-four healthy Chinese volunteers were enrolled in the fasting and postprandial trial,respectively.The test preparation and reference preparation of ibuprofen arginine granules 0.4 g were taken orally in a randomized crossover single dose.Data analysis was performed using Phoenix WinNonlin 8.3.Results In the fasting group,the main pharmacokinetic parameters of ibuprofen in plasma after administration of the test and reference formulations of ibuprofen arginine granules were as follows:Cmax were(51.07±7.43)and(50.10±7.64)μg·mL-1;AUC0-,were(122.78±20.62)and(119.94±21.03)μg·h·mL-1;AUC0_∞ were(125.84±21.31)and(122.64±21.87)μg·h·mL-1,respectively.In the postprandial group,the main pharmacokinetic parameters of ibuprofen in plasma after administration of the test and reference formulations of ibuprofen arginine granules were as follows:Cmax were(17.47±3.56)and(17.89±4.47)μg·mL-1;AUC0-twere(114.33±17.12)and(122.13±29.46)μg·h·mL-1;AUC0_∞ were(134.04±36.72)and(133.96±30.35)μg·h·mL-1,respectively.The 90%confidence intervals of the geometric mean ratio of the two preparations were as follows:Cmax 97.96%-106.02%,AUC0_t 98.77%-105.14%,AUC0-∞ 99.34%-105.19%in fasting group;in postprandial group,Cmax was 92.37%-103.05%,AUC0-t was 93.31%-99.56%,AUC0-∞ was 93.89%-102.91%.Conclusion The test preparation and reference preparation of ibuprofen arginine granules in this study are bioequivalent in healthy adult Chinese volunteers.
9.Analysis of the causes of cage subsidence after oblique lateral lumbar interbody fusion
Zhong-You ZENG ; Ping-Quan CHEN ; Xing ZHAO ; Hong-Fei WU ; Jian-Qiao ZHANG ; Xiang-Qian FANG ; Yong-Xing SONG ; Wei YU ; Fei PEI ; Shun-Wu FAN ; Guo-Hao SONG ; Shi-Yang FAN
China Journal of Orthopaedics and Traumatology 2024;37(1):33-44
Objective To observe the cage subsidence after oblique lateral interbody fusion(OLIF)for lumbar spondylo-sis,summarize the characteristics of the cage subsidence,analyze causes,and propose preventive measures.Methods The data of 144 patients of lumbar spine lesions admitted to our hospital from October 2015 to December 2018 were retrospectively ana-lyzed.There were 43 males and 101 females,and the age ranged from 20 to 81 years old,with an average of(60.90±10.06)years old.Disease types:17 patients of lumbar intervertebral disc degenerative disease,12 patients of giant lumbar disc hernia-tion,5 patients of discogenic low back pain,33 patients of lumbar spinal stenosis,26 patients of lumbar degenerative spondy-lolisthesis,28 patients of lumbar spondylolisthesis with spondylolisthesis,11 patients of adjacent vertebral disease after lumbar internal fixation,7 patients of primary spondylitis in the inflammatory outcome stage,and 5 patients of lumbar degenerative scoliosis.Preoperative dual-energy X-ray bone mineral density examination showed 57 patients of osteopenia or osteoporosis,and 87 patients of normal bone density.The number of fusion segments:124 patients of single-segment,11 patients of two-seg-ment,8 patients of three-segment,four-segment 1 patient.There were 40 patients treated by stand-alone OLIF,and 104 patients by OLIF combined with posterior pedicle screw.Observed the occurrence of fusion cage settlement after operation,conducted monofactor analysis on possible risk factors,and observed the influence of fusion cage settlement on clinical results.Results All operations were successfully completed,the median operation time was 99 min,and the median intraoperative blood loss was 106 ml.Intraoperative endplate injury occurred in 30 patients and vertebral fracture occurred in 5 patients.The mean follow-up was(14.57±7.14)months from 6 to 30 months.During the follow-up,except for the patients of primary lumbar interstitial in-flammation and some patients of lumbar spondylolisthesis with spondylolisthesis,the others all had different degrees of cage subsidence.Cage subsidence classification:119 patients were normal subsidence,and 25 patients were abnormal subsidence(23 patients were grade Ⅰ,and 2 patients were grade Ⅱ).There was no loosening or rupture of the pedicle screw system.The height of the intervertebral space recovered from the preoperative average(9.48±1.84)mm to the postoperative average(12.65±2.03)mm,and the average(10.51±1.81)mm at the last follow-up.There were statistical differences between postop-erative and preoperative,and between the last follow-up and postoperative.The interbody fusion rate was 94.4%.The low back pain VAS decreased from the preoperative average(6.55±2.2 9)to the last follow-up(1.40±0.82),and there was statistically significant different.The leg pain VAS decreased from the preoperative average(4.72±1.49)to the final follow-up(0.60± 0.03),and the difference was statistically significant(t=9.13,P<0.000 1).The ODI index recovered from the preoperative av-erage(38.50±6.98)%to the latest follow-up(11.30±3.27)%,and there was statistically significant different.The complication rate was 31.3%(45/144),and the reoperation rate was 9.72%(14/144).Among them,8 patients were reoperated due to fusion cage subsidence or displacement,accounting for 57.14%(8/14)of reoperation.The fusion cage subsidence in this group had obvious characteristics.The monofactor analysis showed that the number of abnormal subsidence patients in the osteopenia or osteoporosis group,Stand-alone OLIF group,2 or more segments fusion group,and endplate injury group was higher than that in the normal bone mass group,OLIF combined with pedicle screw fixation group,single segment fusion group,and no endplate injury group,and the comparison had statistical differences.Conclusion Cage subsidence is a common phenomenon after 0-LIF surgery.Preoperative osteopenia or osteoporosis,Stand-alone OLIF,2 or more segments of fusion and intraoperative end-plate injury may be important factors for postoperative fusion cage subsidence.Although there is no significant correlation be-tween the degree of cage subsidence and clinical symptoms,there is a risk of cage migration,and prevention needs to be strengthened to reduce serious complications caused by fusion of cage subsidence,including reoperation.
10.Development of a High-throughput Sequencing Platform for Detection of Viral Encephalitis Pathogens Based on Amplicon Sequencing
Li Ya ZHANG ; Zhe Wen SU ; Chen Rui WANG ; Yan LI ; Feng Jun ZHANG ; Hui Sheng LIU ; He Dan HU ; Xiao Chong XU ; Yu Jia YIN ; Kai Qi YIN ; Ying HE ; Fan LI ; Hong Shi FU ; Kai NIE ; Dong Guo LIANG ; Yong TAO ; Tao Song XU ; Feng Chao MA ; Yu Huan WANG
Biomedical and Environmental Sciences 2024;37(3):294-302
Objective Viral encephalitis is an infectious disease severely affecting human health.It is caused by a wide variety of viral pathogens,including herpes viruses,flaviviruses,enteroviruses,and other viruses.The laboratory diagnosis of viral encephalitis is a worldwide challenge.Recently,high-throughput sequencing technology has provided new tools for diagnosing central nervous system infections.Thus,In this study,we established a multipathogen detection platform for viral encephalitis based on amplicon sequencing. Methods We designed nine pairs of specific polymerase chain reaction(PCR)primers for the 12 viruses by reviewing the relevant literature.The detection ability of the primers was verified by software simulation and the detection of known positive samples.Amplicon sequencing was used to validate the samples,and consistency was compared with Sanger sequencing. Results The results showed that the target sequences of various pathogens were obtained at a coverage depth level greater than 20×,and the sequence lengths were consistent with the sizes of the predicted amplicons.The sequences were verified using the National Center for Biotechnology Information BLAST,and all results were consistent with the results of Sanger sequencing. Conclusion Amplicon-based high-throughput sequencing technology is feasible as a supplementary method for the pathogenic detection of viral encephalitis.It is also a useful tool for the high-volume screening of clinical samples.

Result Analysis
Print
Save
E-mail