1.Changes in the body shape and ergonomic compatibility for functional dimensions of desks and chairs for students in Harbin during 2010-2024
Chinese Journal of School Health 2025;46(3):315-320
Objective:
To analyze the change trends in the body shape indicators and proportions of students in Harbin from 2010 to 2024, and to investigate ergonomic compatibility of functional dimensions of school desks and chairs with current student shape indicators, so as to provide a reference for revising furniture standards of desks and chairs.
Methods:
Between September and November of both 2010 and 2024, a combination of convenience sampling and stratified cluster random sampling was conducted across three districts in Harbin, yielding samples of 6 590 and 6 252 students, respectively. Anthropometric shape indicators cluding height, sitting height, crus length, and thigh length-and their proportional changes were compared over the 15-year period. The 2024 data were compared with current standard functional dimensions of school furniture. The statistical analysis incorporated t-test and Mann-Whitney U- test.
Results:
From 2010 to 2024, average height increased by 1.8 cm for boys and 1.5 cm for girls; sitting height increased by 1.5 cm for both genders; crus length increased by 0.3 cm for boys and 0.4 cm for girls; and thigh length increased by 0.5 cm for both genders. The ratios of sitting height to height, and sitting height to leg length increased by less than 0.1 . The difference between desk chair height and 1/3 sitting height ranged from 0.4-0.8 cm. Among students matched with size 0 desks and chairs, 22.0% had a desk to chair height difference less than 0, indicating that the desk to chair height difference might be insufficient for taller students. The differences between seat height and fibular height ranged from -1.4 to 1.1 cm; and the differences between seat depth and buttock popliteal length ranged from -9.8 to 3.4 cm. Among obese students, the differences between seat width and 1/2 hip circumference ranged from -20.5 to -8.7 cm, while it ranged from -12.2 to -3.8 cm among non obese students.
Conclusion
Current furniture standards basically satisfy hygienic requirements; however, in the case of exceptionally tall and obese students, ergonomic accommodations such as adaptive seating allocation or personalized adjustments are recommended to meet hygienic requirements.
2.Application and Production of Systematic Review and Meta-Analyses of Preclinical Studies in the Field of Traditional Chinese Medicine
Wenya WANG ; Chengyang JING ; Lanjun SHI ; Bin MA ; Xing LIAO
Journal of Traditional Chinese Medicine 2025;66(13):1333-1339
Preclinical studies include pharmacology, toxicology, pharmacokinetics research of animal experiments and in vitro experiments, which are crucial steps in the pre-marketing drugs and medical products, and are essential for exploring the mechanisms of traditional Chinese Medicine (TCM) therapeutic mechanism and promoting clinical translation. Systematic reviews and meta-analyses of preclinical studies in the field of TCM can comprehensively integrate preclinical evidence, consolidate research findings, assess the quality and risk of bias of included studies, enhance the utilization of research results, reduce resource waste, and promote the iterative optimization of TCM research models and evaluation indicators. This article introduced the process and methodology of conducting systematic review and meta-analyses of preclinical studies in TCM from nine steps, defining the research question, forming a research team, writing and registering a study protocol, conducting a comprehensive search, screening literature, evaluating included studies, extracting data, synthesizing data (meta-analysis), and reporting systematic reviews. It aims to provide methodological references for conducting systematic reviews and meta-analyses of preclinical studies in TCM and to promote the establishment and improvement of the evidence system in the field of TCM.
3.Enhancing Disciplinary Development Through Journal Columns: Taking the "Clinical Practice Guidelines"Column in Medical Journal of Peking Union Medical College Hospital as an Example
Meihua WU ; Hui LIU ; Qi ZHOU ; Qianling SHI ; Na LI ; Yule LI ; Xiaoqing LIU ; Kehu YANG ; Jinhui TIAN ; Long GE ; Bin MA ; Xiuxia LI ; Xuping SONG ; Xiaohui WANG ; Yaolong CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(5):1315-1324
To explore the role of the "Clinical Practice Guidelines" column and others in the We collected papers published by the Lanzhou University Evidence-Based Medicine Center team in the "Clinical Practice Guidelines" column and others from 2018 to 2025. These publications were analyzed across multiple dimensions, including authorship and institutional affiliations, citation metrics, and research themes and content. A total of 59 papers were included in the analysis, with authors representing 70 domestie and international research institutions. The cumulative citation count was 639, with the highest single-paper citation frequency reaching 101. The average citation per paper was 10.8, and total downloads exceeded 30 000. The content focused on key themes such as guideline terminology, development methodology, guideline evaluation, and dissemination and implementation. The evolution of research topics progressed from critiques of common misconceptions and hot topies in the field to multidimensional evaluations of thecurrent state of Chinese guidelines, culminating in the fommulation of industry standards for guidelines. These contributions have provided critical references for translating guideline theory into practice in China and have garnered widespread attention and discussion among scholars in the field. The "Clinical Practice Guidelines" column and others in the
4.The three-connections and four-screwings technique via a single ilioinguinal approach for treatment of high double column acetabular fractures
Huijun LIU ; Qianqian ZHOU ; Xianglong XIONG ; Bin ZHANG ; Zhongnan GUI ; Bo WANG ; Yajun TANG ; Peng XIANG ; Qing SHI
Chinese Journal of Orthopaedic Trauma 2024;26(3):262-266
Objective:To investigate the clinical efficacy of three-connections and four-screwings technique in the treatment of high double column acetabular fractures through a single ilioinguinal approach.Methods:A retrospective study was conducted to analyze the data of 42 patients who had been treated for high double column acetabular fractures from June 2017 to June 2020 at Trauma Ward 2, Department of Orthopedics and Traumatology, The First Hospital of Traditional Chinese Medicine of Changde. There were 19 males and 23 females with an age of (42.7±25.6) years. 29 injuries were due to a traffic accident, 12 ones to fall from a height, and one to fall. The time from injury to operation was (4.5±2.1) days. All the patients were treated by the three-connections and four-screwings technique through a single ilioinguinal approach. Briefly, the anterior column was connected and secured to the main bone using 3 routes, and the posterior column was attached and fixated to the anterior column reset using 2 or 3 of the 4 screwings. The operation time, intraoperative blood loss, fracture reduction quality, fracture healing time, hip function at the last follow-up and complications during the follow-up were recorded.Results:For this cohort, the operation time was (150.0±30.5) min, and intraoperative blood loss (300.0±50.0) mL. According to the Matta scale for postoperative acetabular fracture reduction, 34 cases were excellent, 6 cases good, and 2 cases acceptable, with an excellent and good rate of 95.2% (40/42). After operation one patient had fat liquefaction and wound exudation which responded to drainage and dressing change. The 42 patients were followed up for (15.0±3.4) months. All fractures healed after (11.0±2.0) months. By the modified Merle d'Aubigné & Postel scoring system, the hip function was evaluated at the last follow-up as excellent in 33 cases, as good in 6 cases, and as fair in 3 cases, yielding an excellent and good rate of 92.9% (39/42).Conclusions:In the treatment of high double column acetabular fractures, the three-connections and four-screwings technique through a single ilioinguinal approach can lead to fine reduction and rigid fixation by lag screw compression and neutralization plate protection. Consequently, early functional exercises can be performed to secure good therapeutic outcomes for the patients.
5.Interpretation of the Guideline for Multi-dimensional and Multi-criteria Comprehensive Evaluation of Chinese Patent Medicine:weighting of evaluation indicators
Haili ZHANG ; Bin LIU ; Weili WANG ; Wenjie CAO ; Yijiu YANG ; Ziteng HU ; Yaxin CHEN ; Ning LIANG ; Huizhen LI ; Qianzi CHE ; Xingyu ZONG ; Zhao CHEN ; Yanping WANG ; Nannan SHI
China Pharmacy 2024;35(7):773-777
OBJECTIVE To provide a detailed report and interpretation of the method and results for determining the weights of the technical indicators from the “multi-dimensional and multi-criteria comprehensive evaluation index system (first edition)” stated in Guideline for Multi-dimensional and Multi-criteria Comprehensive Evaluation of Chinese Patent Medicine. METHODS Normalization calculations were performed on the comprehensive weight values calculated by the analytic hierarchy process and expert weighting method to obtain the objective weights of the indicators. RESULTS The weight results of the six primary dimensions in the current comprehensive evaluation indicator system of Chinese patent medicine showed effectiveness dimension> safety dimension>standard dimension>application dimension>scientific dimension>economic dimension, with weight values of 0.281 0, 0.268 5, 0.195 8, 0.107 3, 0.096 1 and 0.051 3 respectively, consistent with the results of most researches currently. CONCLUSIONS The process of weight determination in this indicator system is scientifically reasonable, with clear methods and clear interpretations, and is worthy of further optimization and widespread application.
6.Effectiveness of the artificial intelligence image recognition system in diagnosing endometrial cytopathology
Jing AN ; Panyue YIN ; Bin WANG ; Guizhi SHI ; Dexing ZHONG ; Jianliu WANG ; Qiling LI
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(2):343-347
【Objective】 To explore the effectiveness of an image recognition system based on artificial intelligence (AI) in diagnosing benign and malignant endometrial cell clumps. 【Methods】 We selected endometrial cytological specimens from The First Affiliated Hospital of Xi’an Jiaotong University and Xi’an Daxing Hospital from August 2021 to February 2023; histopathology was used as the gold standard. We compared and analyzed the sensitivity, specificity, positive predictive value, negative predictive value, accuracy and diagnostic time of AI image recognition system (AI diagnosis) and professional pathologists’ manual diagnosis (manual diagnosis) of benign and malignant endometrial cell clumps. 【Results】 Among the 126 patients included in the analysis, the overall coincidence rate of AI diagnosis and histological diagnosis was 92.1% (116/126), which was highly consistent with histopathological results (Kappa=0.841). The overall coincidence rate of manual diagnosis and histological diagnosis was 94.4% (119/126), which was highly consistent with histopathological results (Kappa=0.889). There was no statistically significant difference between AI diagnosis and manual diagnosis methods (χ2=0.568, P=0.451). The sensitivity, specificity, positive predictive value, and negative predictive value of AI diagnosis were 91.8%, 92.3%, 91.8%, and 92.3%, respectively. There were 126 cytology sections, each of which required 6.67 minutes for manual diagnosis and 5.00 minutes for AI diagnosis. 【Conclusion】 The AI image recognition system has high diagnostic accuracy, sensitivity and specificity, which is equivalent to the manual diagnosis level of professional pathologists. Therefore, this system has application value in the diagnosis of benign and malignant endometrial cell clumps.
7.Methodological Consideration on Combination Model of TCM Clinical Practice Guidelines and Real-world Study
Guozhen ZHAO ; Huizhen LI ; Ning LIANG ; Haili ZHANG ; Bin LIU ; Qianzi CHE ; Feng ZHOU ; He LI ; Xiaowen CHEN ; Long YE ; Jiahao LIN ; Xingyu ZONG ; Dingyi WANG ; Nannan SHI ; Yanping WANG
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(22):87-93
The clinical practice guidelines of traditional Chinese medicine (TCM) have problems such as limited clinical application and unclear implementation effects, which may be related to the lack of clinical practice evidence. To provide reliable and precise evidence for clinical practice, this article proposes a model of combining TCM guidelines with real-world study, which includes 4 steps. Firstly, during the implementation process of the guidelines, a high-quality research database is established. Secondly, the recommendations in the guidelines are evaluated based on the established database in multiple dimensions, including applicability, effectiveness, safety, and cost-effectiveness, and thus their effectiveness in practical applications can be determined. Thirdly, based on the established database, core prescriptions are identified, and the targeted populations and medication plans are determined. That is, the best treatment regimen is established based on the analysis of abundant clinical data regarding the effects of different medication frequencies, dosages, and duration on efficacy. Fourthly, the guidelines are updated according to the real-world evidence. The research based on this model can provide real-world evidence for ancient and empirical prescriptions, improving their application in clinical practice. Moreover, this model can reduce research costs and improve research efficiency. When applying this model, researchers need to pay attention to the quality of real-world evidence, ensuring that it can truly reflect the situation in clinical practice. In addition, importance should be attached to the clinical application of guideline recommendations, ensuring that doctors can conduct standardized diagnosis and treatment according to the guidelines. Finally, full-process participation of multidisciplinary experts is encouraged to ensure the comprehensiveness and scientificity of the study. In conclusion, the application of this model will contribute to the development of TCM guidelines responsive to the needs of clinical practice and achieve the goal of promoting the homogenization of TCM clinical diagnosis and treatment.
8.Correlation between expressions of serum COL1A1/2 and intracranial aneurysm rupture
Jun-Fei SHI ; Bin FENG ; Jiang LI ; Shao-Peng LIU ; Chao LYU ; Gui-Qing WANG
Journal of Regional Anatomy and Operative Surgery 2024;33(1):51-54
Objective To detect the levels of serum collagen type Ⅰ alpha 1 chain(COL1A1)and collagen type Ⅰ alpha 2 chain(COL1A2)in patients with intracranial aneurysm(IA),and explore their correlations with aneurysm rupture.Methods A total of 110 IA patients admitted to our hospital were regarded as the IA group and another 100 volunteers who underwent physical examination in our hospital were regarded as the control group.The expression levels of serum COL1A1 and COL1A2 were detected by ELISA.The IA patients were divided into the ruptured group(n=66)and unruptured group(n=44)according to the presence or absence of aneurysm rupture,and the clinical data and expression levels of serum COL1A1 and COL1A2 were compared between the two groups.The expression levels of serum COL1A1 and COL1A2 in patients with different Hunt-Hess grades were compared.The risk factors of aneurysm rupture in patients with IA were analyzed by multivariate Logistic regression analysis.The predictive value of serum COL1A1 and COL1A2 for aneurysm rupture in patients with IA were evaluated by receiver operating characteristic(ROC)curve.The correlation of serum COL1A1 and COL1A2 with Hunt-Hess grade for patients in rupture group was analyzed by Spearman correlation analysis.Results The expression levels of serum COL1A1 and COL1A2 for patients in the IA group were significantly higher than those in the control group(P<0.05).The number of patients with hypertension,diabetes mellitus,hyperlipidemia,aneurysm diameter>10 mm,and the expression levels of serum COL1A1 and COL1A2 in the rupture group were significantly more/higher than those in the unruptured group(P<0.05).The expression levels of serum COL1A1 and COL1A2 in patients with Hunt-Hess grades from Ⅲ to Ⅳ were significantly higher than those in patients with grades from Ⅰ to Ⅱ(P<0.05).The expression levels of serum COL1A1 and COL1A2 for patients in the rupture group were positively correlated with Hunt-Hess grade(r=0.562,0.414,P<0.05).Multivariate Logistic regression analysis showed that hypertension,diabetes mellitus,aneurysm diameter>10 mm,and increased expression levels of COL1A1 and COL1A2 were risk factors for aneurysm rupture in IA patients(P<0.05).The area under the curve(AUC)of aneurysm rupture predicted by serum COL1A1 and COL1A2 together was significantly higher than that predicted by COL1A1 alone(Z=1.905,P=0.028)and COL1A2 alone(Z=1.754,P=0.040).Conclusion The increased expression levels of serum COL1A1 and COL1A2 are risk factors for aneurysm rupture in patients with IA,and their combined prediction of aneurysm rupture in IA patients has certain clinical value.
9.The First Application of Domestically Produced Self-expanding Transcatheter Aortic Valve Controllable Bending Delivery System in China
Yang CHEN ; Guoliang CHEN ; Di SONG ; Hongliang ZHANG ; Moyang WANG ; Guannan NIU ; Zheng ZHOU ; Qian ZHANG ; Qingrong LIU ; Zhenyan ZHAO ; Jie ZHAO ; Bin ZHANG ; Dejing FENG ; Wence SHI ; Jicheng XI ; Yongjian WU
Chinese Circulation Journal 2024;39(3):285-289
A domestically produced self-expanding transcatheter aortic valve controllable bending delivery system(VitaFlow? Ⅲcontrollable bending retrievable delivery system)was first used to perform transcatheter aortic valve replacement(TAVR)in a symptomatic severe aortic valve stenosis patient with severe heart failure and high risk of surgery in China on September 22,2023.The patient successfully completed TAVR under general anesthesia,with good valve position and function after the operation.Before discharge and at one month of follow-up,the patient's symptoms and degree of heart failure were significantly improved.The follow-up results of this case showed that the VitaFlow? Ⅲ controllable bending retrievable delivery system for TAVR is safe and feasible,and future prospective,multicenter clinical trials are expected to evaluate its efficacy.
10.Chinesization of the HEMO-FISS-QoL questionnaire and its reliability and validity
Songpeng SUN ; Shan JIA ; Fangfang XU ; Tianyu LI ; Zhiyun ZHANG ; Qiaorong CAO ; Xinjian LI ; Yao WU ; Weiping WAN ; Bin SHI ; Jianguo WANG ; Hong NI ; Longyu LIANG ; Xingxiao HUO ; Tianqing YANG ; Lei TIAN ; Ying TIAN ; Mei LIN ; Zhanjun WANG ; Yangyang ZHOU ; Hongchuan CHU ; Riyu LIAO ; Kuerban XIEYIDA ; Junhong LONG ; Shuxin ZHANG
Chinese Journal of Behavioral Medicine and Brain Science 2024;33(1):75-82
Objective:To evaluate the reliability and validity of the Chinese version of HEMO-FISS-QoL(HF-QoL) questionnaire (HF-QoL-C) in the Chinese population with hemorrhoids.Methods:From November 2021 to November 2022, a self-constructed general information questionnaire, HF-QoL-C, and the 36-item short form health survey (SF-36), Goligher classification, and Giordano severity of hemorrhoid symptom questionnaire (GSQ) were used to conduct a questionnaire survey on 760 hemorrhoid patients in the anorectal department of six hospitals. The data was analyzed for reliability and validity using SPSS 21.0 and AMOS 26.0 software.Results:The Cronbach's α coefficient of HF-QoL-C and its dimension ranged from 0.831 to 0.960, and the split coefficient was 0.832-0.915. Four common factors were extracted through principal component exploratory factor analysis. Confirmatory factor analysis indicated acceptable structural validity( χ2/ df=8.152, RSMEA=0.097, CFI=0.881, IFI=0.881, NFI=0.867). HF-QoL-C was correlated with SF36 and GSQ( r=-0.694, 0.501, both P<0.01). There were differences in the total score and dimensional scores of HF-QoL-C between surgical and drug treated patients, different grades of Goligher classification for hemorrhoidal disease, and different ranges of hemorrhoid prolapse (all P<0.001). No ceiling effect was found in the total score and the scores of each dimension(0.3%-2.0%). There was a floor effect in both psychological function and sexual activity dimensions (16.7%, 35.1%). Conclusion:HF-QoL-C has good reliability and validity, which can be used to measure the quality of life of Chinese hemorrhoid patients.


Result Analysis
Print
Save
E-mail