1.Sufei Pingchuan Formula (肃肺平喘方) for the Treatment of Bronchiectasis Patients Combined with Airflow Limitation of Phlegm-Heat Obstructing the Lung and Lung-Spleen Qi Deficiency Syndrome: A Randomised Controlled Trial
Shasha YUAN ; Haiyan ZHANG ; Xia SHI ; Bing WANG ; Xiaodong CONG ; Qing MIAO
Journal of Traditional Chinese Medicine 2025;66(6):581-587
ObjectiveTo evaluate the effectiveness and safety of Sufei Pingchuan Formula (肃肺平喘方) in the treatment of bronchiectasis with airflow limitation, phlegm-heat obstructing the lung, and lung-spleen qi deficiency syndrome. MethodsA randomized, double-blind, placebo-controlled trial was conducted. A total of 72 patients with stable bronchiectasis with airflow limitation of phlegm-heat obstructing the lung and lung-spleen qi deficiency syndrome were randomly divided into treatment group and control group, with 36 cases in each group. On the basis of regular inhalation of tiotropium bromide inhalation spray, the treatment group was given Sufei Pingchuan Formula granules, and the control group was given Sufei Pingchuan Formula granule simulant. The course of treatment in both groups was 12 weeks. The pulmonary function of both groups before and after treatment was observed, specifically focusing on forced expiratory volume in one second (FEV1); the modified British Medical Research Council (mMRC) dyspnea scale, 24-hour sputum volume, COPD assessment test (CAT), and traditional Chinese medicine (TCM) syndrome scores were assessed before treatment and after 4, 8, and 12 weeks of treatment; acute exacerbations were recorded at weeks 4, 8, and 12; additionally, changes in routine blood tests, urinalysis, liver and kidney function, and adverse events were monitored before and after treatment. ResultsAfter treatment, 4 patients in the treatment group and 6 in the control group dropped out. After 12 weeks of treatment, FEV1 increased in both groups compared to pre-treatment levels (P<0.05), but the difference between groups was not statistically significant (P>0.05). Compared to before treatment, the treatment group showed a reduction in mMRC scores after 12 weeks (P<0.05) and a decrease in 24-hour sputum volume, CAT scores, and TCM syndrome scores at weeks 4, 8, and 12 (P<0.05). In the control group, 24-hour sputum volume decreased after 12 weeks (P<0.05), and TCM syndrome scores decreased at weeks 8 and 12 (P<0.05). Compared to the control group, the treatment group showed a greater reduction in mMRC scores at week 12 (P<0.05), a decrease in 24-hour sputum volume and TCM syndrome scores at weeks 4, 8, and 12 (P<0.05), and lower CAT scores at weeks 8 and 12 (P<0.05). The frequency and number of acute exacerbations in the treatment group were significantly lower than those in the control group at week 12 (P<0.05). No severe adverse events occurred in either group. ConclusionSufei Pingchuan Formula can improve the pulmonary function FEV1, the severity of dyspnea, reduce 24-hour sputum volume and frequent acute exacerbations, and improve the quality of life in patients with bronchiectasis and airflow limitation, with good safety.
2.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
3.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
4.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
5.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
6.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
7.Construction and application of the "Huaxi Hongyi" large medical model
Rui SHI ; Bing ZHENG ; Xun YAO ; Hao YANG ; Xuchen YANG ; Siyuan ZHANG ; Zhenwu WANG ; Dongfeng LIU ; Jing DONG ; Jiaxi XIE ; Hu MA ; Zhiyang HE ; Cheng JIANG ; Feng QIAO ; Fengming LUO ; Jin HUANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):587-593
Objective To construct large medical model named by "Huaxi HongYi"and explore its application effectiveness in assisting medical record generation. Methods By the way of a full-chain medical large model construction paradigm of "data annotation - model training - scenario incubation", through strategies such as multimodal data fusion, domain adaptation training, and localization of hardware adaptation, "Huaxi HongYi" with 72 billion parameters was constructed. Combined with technologies such as speech recognition, knowledge graphs, and reinforcement learning, an application system for assisting in the generation of medical records was developed. Results Taking the assisted generation of discharge records as an example, in the pilot department, after using the application system, the average completion times of writing a medical records shortened (21 min vs. 5 min) with efficiency increased by 3.2 time, the accuracy rate of the model output reached 92.4%. Conclusion It is feasible for medical institutions to build independently controllable medical large models and incubate various applications based on these models, providing a reference pathway for artificial intelligence development in similar institutions.
8.Differential characteristics of motor development levels, inhibitory control and cognitive flexibility processing in preschool children
ZHENG Quanliang, WANG Tingzhao, SHI Bing, CHI Aiping, NING Ke
Chinese Journal of School Health 2024;45(2):258-262
Objective:
To explore the neural processing differences in inhibitory control and cognitive flexibility associated with motor development levels in preschool children, so as to provide a basis for motor learning and cognitive development in preschool children.
Methods:
From March 20 to 31 in 2023, a total of 84 preschool children aged 4-6 were recruited from two kindergartens in Xi an City. The MOBAK-KG Motor Development Assessment Scale was used to assess the children s motor development levels. The Go/no go task paradigm was employed to test inhibitory control ability, and the Dimensional Change Card Sort (DCCS) task paradigm was utilized to evaluate cognitive flexibility. Functional near infrared spectroscopy (fNIRS) was used to monitor the preschool children s prefrontal cortex oxygenation dynamics during inhibitory control and cognitive flexibility tasks. Malab software and Homer 2 plugins were used to calculate prefrontal oxygenated hemoglobin concentration of preschool children during the tasks.
Results:
The high motor skills group exhibited significantly higher task accuracy during inhibitory control and cognitive flexibility tasks [0.95(0.92, 0.97),(0.54±0.12)] compared to the low motor skill group[0.93(0.85, 0.97),(0.45±0.13)] ( Z/t =-2.09, 3.14 , P <0.05). During the inhibitory control task, the high motor skill group [0.24(0.10,0.41), 0.34(0.16,0.62), 0.30(0.07, 0.52 ), 0.26(0.09, 0.53), 0.15(0.01, 0.43), 0.34(0.10, 0.67)mol/L] showed significantly higher oxygenated hemoglobin concentrations in the left and right dorsolateral prefrontal cortices (L-DLPFC, R-DLPFC), left and right pars triangular Broca s areas ( L- PTBA, R-PTBA), and left and right frontopolar areas (L-FPA, R-FPA) compared to the low motor skill group [0.04( -0.13 , 0.15), 0.00(-0.12, 0.11), -0.01(-0.17, 0.14), 0.04(-0.14, 0.16), -0.01(-0.16, 0.12), -0.03(-0.21, 0.15) mol/L ] ( Z=-4.83, -5.57, -4.77, -4.10, -3.45, -5.74, P <0.01). During the cognitive flexibility task, the high motor skill group[0.21(0.03, 0.36), 0.28(0.15, 0.45), 0.15(0.05, 0.30), 0.20(0.05, 0.37), 0.04(-0.17, 0.26), 0.14(-0.08, 0.40) mol/L ] exhibited significantly higher oxygenated hemoglobin concentrations in the L-DLPFC, R-DLPFC, L-PTBA, R-PTBA, L- FPA, R-FPA brain regions compared to the low motor skill group [0.02(-0.20, 0.23), 0.02(-0.12, 0.21), 0.00(-0.22, 0.16 ), 0.00(-0.16, 0.15), -0.05(-0.25, 0.06), 0.01(-0.23, 0.20)mol/L] ( Z=-3.63, -4.45, -3.58, -3.75, -2.18, -1.98 , P <0.05).
Conclusions
The motor development level in preschool children is closely related to inhibitory control and cognitive flexibility. It is crucial to emphasize motor learning in early childhood to further promote holistic development of both mind and body.
9. Association between index finger and ring finger length ratios and polymorphism of homeobox A11 gene locus among Ningxia college students
Meng-Yi YANG ; Shi-Bo NIU ; Jing ZHANG ; Jie DANG ; Zhan-Bing MA ; Hong LU ; Zheng-Hao HUO
Acta Anatomica Sinica 2024;55(1):62-66
Objective To investigate the association between the index finger and ring finger length ratio (2D ∶ 4D) and of four loci (rs6461992‚ rs6968828‚ rs7801581‚ rs17427875) polymorphism of homeobox (HOX) A11 gene among Ningxia college students. Methods Digit camera was used to collect frontal hand photos of 667 Han college students (348 males and 319 females) from Ningxia province; Image analysis software was used to mark the anatomical points and measure finger lengths of the index and ring fingers of both hands; multiplex PCR was used to detect each locus polymorphisms of HOXA11 gene; statistical software was used to compare and analyze the differences and associations of 2D ∶4D and gene polymorphisms between different genders. Results Among Ningxia Han college students‚ both left hand and right hand 2D ∶ 4D were significantly higher in females than those of in males (all P< 0. 05)‚ and there were no significant sex differences in right-left hand 2D ∶4D; the genotypes and allele frequencies of rs7801581 locus of HOXA11 gene differed significantly between genders (all P < 0. 05)‚ and none of the other locus polymorphisms showed any significant sex differences; only female left hand 2D ∶4D was significantly associated with rs6461992 locus genotype in the relationship between 2D ∶4D and HOXA11 polymorphisms (P<0. 05). Conclusion There were significant sex differences in 2D ∶ 4D among Han college students in Ningxia‚ and the rs6461992 locus polymorphism of HOXA11 gene may be associated with the formation of 2D ∶4D in females.
10.Application Progress of Electrochemical Methods in Quality Control of Traditional Chinese Medicine
Yan-Bing PAN ; IHSAN AWAIS ; Min SHI ; Wen-Wen MA ; MURTAZA GHULAM ; Ke-Fei HU ; Jun LI ; Xian-Ju HUANG ; Han CHENG
Chinese Journal of Analytical Chemistry 2024;52(1):22-34
The quality control of traditional Chinese medicine(TCM)is the core issue to ensure the modernization,industrialization and internationalization of TCM.Compared with other detection methods,electrochemical analysis method has many advantages such as high sensitivity,fast detection speed and low cost,making it an important means of quality control for TCM and having broad development prospects.This article reviewed the research progress of electrochemical methods in quality control of TCM in recent years,discussed the application of electrochemical fingerprinting technique in identification of TCM,and comprehensively summarized the application of electrochemical technology in analyzing effective components and harmful substances in TCM,including flavonoids,alkaloids,quinones,glycosides,heavy metals and pesticide residues.Finally,the development prospects of electrochemical methods in the field of quality control of TCM were discussed.


Result Analysis
Print
Save
E-mail