1.Research on software development and smart manufacturing platform incorporating near-infrared spectroscopy for measuring traditional Chinese medicine manufacturing process.
Yan-Fei WU ; Hui XU ; Kai-Yi WANG ; Hui-Min FENG ; Xiao-Yi LIU ; Nan LI ; Zhi-Jian ZHONG ; Ze-Xiu ZHANG ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(9):2324-2333
Process analytical technology(PAT) is a key means for digital transformation and upgrading of the traditional Chinese medicine(TCM) manufacturing process, serving as an important guarantee for consistent and controllable TCM product quality. Near-infrared(NIR) spectroscopy has become the core technology for measuring the TCM manufacturing process. By incorporating NIR spectroscopy into PAT and starting from the construction of a smart platform for the TCM manufacturing process, this paper systematically described the development history and innovative application of the combination of NIR spectroscopy with chemometrics in measuring the TCM manufacturing process by the research team over the past two decades. Additionally, it explored the application of a validation method based on accuracy profile(AP) in the practice of NIR spectroscopy. Furthermore, the software development progress driven by NIR spectroscopy supported by modeling technology was analyzed, and the prospect of integrating NIR spectroscopy in smart factory control platforms was exemplified with the construction practices of related platforms. By integrating with the smart platform, NIR spectroscopy could improve production efficiency and guarantee product quality. Finally, the prospect of the smart platform application in measuring the TCM manufacturing process was projected. It is believed that the software development for NIR spectroscopy and the smart manufacturing platform will provide strong technical support for TCM digitalization and industrialization.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/analysis*
;
Software
;
Medicine, Chinese Traditional
;
Quality Control
2.Additional role of low-density lipoprotein cholesterol on the risk of osteoporosis in men with or without coronary heart disease: a real-world longitudinal study.
Jing ZENG ; Zi-Mo PAN ; Ting LI ; Ze-Yu CHEN ; Xiao-Yan CAI ; Mei-Liang GONG ; Xin-Li DENG ; Sheng-Shu WANG ; Nan LI ; Miao LIU ; Chun-Lin LI
Journal of Geriatric Cardiology 2025;22(2):219-228
BACKGROUND:
Early control of low-density lipoprotein cholesterol (LDL-C) is crucial for reducing the progress of cardiovascular disease. However, its additional role to the risk of primary osteoporosis in men with coronary heart disease was inconclusive. Our study aims to determine the association of LDL-C and its trajectories for osteoporosis risk in the middle-aged and aged men of China.
METHODS:
The retrospective cohort study of 1546 men aged 69.74 ± 11.30 years conducted in Beijing, China from 2015 to 2022. And the incidence of primary osteoporosis was annually recorded. LDL-C trajectories were further identified by latent class growth model using repeated measurements of LDL-C. The association of baseline LDL-C for osteoporosis was estimated using hazard ratio (HR) with 95% CI in Cox proportional hazard model, while mean level and trajectories of LDL-C for osteoporosis were evaluated using odds ratio (OR) with 95% CI in logistic regression model.
RESULTS:
During the median 6.2-year follow-up period, 70 men developed primary osteoporosis. The higher level of baseline LDL-C (HR = 1.539, 95% CI: 1.012-2.342) and mean LDL-C (OR = 2.190, 95% CI: 1.443-3.324) were associated with higher risk of osteoporosis in men with coronary heart disease after adjusted for covariates. Compared with those in the LDL-C trajectory of low-stable decrease, participants with medium-fluctuant trajectory, whose longitudinal LDL-C started with a medium LDL-C level and appeared an increase and then decrease, were negatively associated with osteoporosis risk (OR = 2.451, 95% CI: 1.152-5.216). And participants with initially high LDL-C level and then a rapid decrease demonstrated a tendency towards reduced risk (OR = 0.718, 95% CI: 0.212-2.437).
CONCLUSIONS
Elevated LDL-C level and its long-term fluctuation may increase the risk of primary osteoporosis in men. Early controlling a stable level of LDL-C is also essential for bone health.
3.Progress on Wastewater-based Epidemiology in China: Implementation Challenges and Opportunities in Public Health.
Qiu da ZHENG ; Xia Lu LIN ; Ying Sheng HE ; Zhe WANG ; Peng DU ; Xi Qing LI ; Yuan REN ; De Gao WANG ; Lu Hong WEN ; Ze Yang ZHAO ; Jianfa GAO ; Phong K THAI
Biomedical and Environmental Sciences 2025;38(11):1354-1358
Wastewater-based epidemiology has emerged as a transformative surveillance tool for estimating substance consumption and monitoring disease prevalence, particularly during the COVID-19 pandemic. It enables the population-level monitoring of illicit drug use, pathogen prevalence, and environmental pollutant exposure. In this perspective, we summarize the key challenges specific to the Chinese context: (1) Sampling inconsistencies, necessitating standardized 24-hour composite protocols with high-frequency autosamplers (≤ 15 min/event) to improve the representativeness of samples; (2) Biomarker validation, requiring rigorous assessment of excretion profiles and in-sewer stability; (3) Analytical method disparities, demanding inter-laboratory proficiency testing and the development of automated pretreatment instruments; (4) Catchment population dynamics, reducing estimation uncertainties through mobile phone data, flow-based models, or hydrochemical parameters; and (5) Ethical and data management concerns, including privacy risks for small communities, mitigated through data de-identification and tiered reporting platforms. To address these challenges, we propose an integrated framework that features adaptive sampling networks, multi-scale wastewater sample banks, biomarker databases with multidimensional metadata, and intelligent data dashboards. In summary, wastewater-based epidemiology offers unparalleled scalability for equitable health surveillance and can improve the health of the entire population by providing timely and objective information to guide the development of targeted policies.
China/epidemiology*
;
Humans
;
Wastewater/analysis*
;
COVID-19/epidemiology*
;
Public Health
;
Wastewater-Based Epidemiological Monitoring
;
SARS-CoV-2
4.Clinical Observation of Self-formulated Shenqi Buwei Decoction in the Treatment of Stable Chronic Obstructive Pulmonary Disease with Lung-Spleen Qi Deficiency Syndrome
Meng-Meng ZHANG ; Qiao LI ; Qing-Yong XIONG ; Jia-Yao LI ; Lin-Na XIE ; Jia-Sheng LU ; Ze-Geng LI
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(8):1994-2000
Objective To observe the clinical efficacy of self-formulated Shenqi Buwei Decoction(derived from Huangqi Renshen Decoction)in treating patients with stable chronic obstructive pulmonary disease(COPD)differentiated as lung-spleen qi deficiency syndrome.Methods A total of 110 patients with stable COPD differentiated as lung-spleen qi deficiency syndrome were randomly divided into a control group and an observation group,with 55 patients in each group.The control group was given Tiotropium Bromide Inhalation Powder for the inhalation treatment,and the observation group was given Shenqi Buwei Decoction on the basis of treatment for the control group,and the course of treatment covered 3 months.The changes of pulmonary function indicators of forced expiratory volume in one second(FEV1),forced vital capacity(FVC),and one-second rate of FEV1/FVC,modified Medical Research Council index(mMRC)dyspnea scores,6-minute walk test(6MWT),COPD Assessment Test(CAT)scores,and traditional Chinese medicine(TCM)syndrome scores in the two groups were observed before and after treatment.After treatment,the clinical efficacy and safety of the two groups were evaluated.Results(1)During the trial,one patient was excluded and two patients fell off from the observation group,and three patients fell off from the control group.Eventually,52 patients in each of the two groups were included in the efficacy statistics.(2)After 3 months of treatment,the total effective rate of the observation group was 80.77%(42/52)and that of the control group was 67.31%(35/52).The intergroup comparison(tested by chi-square test)showed that the therapeutic effect of the observation group was slightly superior to that of the control group,but the difference was not statistically significant(P>0.05).(3)In terms of indexes,After treatment,the levels of pulmonary function indicators of FEV1,FEV1/FVC in the control group and FEV1,FVC,FEV1/FVC in the observation group were significantly improved compared with those before treatment(P<0.05),and the improvement of FEV1,FVC,FEV1/FVC in the observation group was significantly superior to that in the control group(P<0.05).(4)After treatment,the 6MWT,mMRC and CAT scores of the two groups were significantly improved compared with those before treatment(P<0.05),and the improvement in the observation group was significantly superior to that in the control group(P<0.05).(5)After treatment,the TCM syndrome scores of the two groups of patients were significantly decreased in comparison with those before treatment(P<0.05),and the decrease in the observation group was significantly superior to that in the control group(P<0.05).(6)During the treatment process,no obvious adverse reactions occurred in the two groups of patients,there were no abnormal changes in the safety indicators,either.Conclusion On the basis of conventional western medicine treatment,the combined use of Shenqi Buwei Decoction exerts certain efficacy in the treatment of patients with stable COPD differentiated as lung-spleen qi deficiency syndrome.The combined therapy can effectively improve the ventilation function,relieve the clinical symptoms,improve the quality of life and delay the decline of lung function of the patients.
5.Comparison of the predictive value of new simplified insulin resistance assessment indexes in identifying left ventricular subclinical dysfunction in T2DM patients
Yan-Yan CHEN ; Meng-Ying LI ; Jie ZHOU ; Jian-Fang FU ; Ying ZHANG ; Yi WANG ; Cheng WANG ; Xiang-Yang LIU ; Sheng-Jun TA ; Li-Wen LIU ; Ze-Ping LI ; Xiao-Miao LI
Medical Journal of Chinese People's Liberation Army 2024;49(2):137-143
Objective To investigate the predictive value of new simplified insulin resistance(IR)assessment indexes in identifying subclinical left ventricular systolic function impairment in patients with type 2 diabetes mellitus(T2DM).Methods A total of 150 T2DM patients with preserved left ventricular ejection fraction(LVEF≥50%)who were admitted to Department of Endocrinology of the First Affiliated Hospital of Air Force Medical University from June 2021 to December 2021 were retrospectively analyzed.All patients underwent two-dimensional speckle tracking echocardiography to measure left ventricular global longitudinal strain(GLS).According to GLS value,the subjects were divided into the normal group(GLS≥18%group,n=80)and the impaired group(GLS<18%group,n=70).Some new simplified IR assessment indicators were calculated and compared between the two groups,including body mass index(BMI),TG/HDL-C ratio,triglyceride-glucose(TyG)index,TyG-BMI index,TyG-WHR and metabolic score for IR(METS-IR).Correlation between the GLS and the new simplified IR assessment indexes was analyzed.The receiver operating characteristic(ROC)curve was used to analyze the diagnostic efficacy of different simplified IR assessment indexes,with the area under the curve(AUC)calculated.Furthermore,according to whether the subjects were complicated with hypertension,binary logistics regression analysis was performed to explore the independent correlation between the simplified IR assessment index and GLS<18%.Results Total 150 were included with aged(54.5±13.7)years with 96(64.0%)men and 54(36.0%)women.Compared with the GLS≥18%group,the TG/HDL-C ratio,TyG index,TyG-BMI,and METS-IR of subjects in the GLS<18%group were significantly increased(P<0.05).Pearson correlation analysis showed that TG/HDL-C ratio,TyG index,TyG-BMI,TyG-WHR,and METS-IR were negatively correlated with GLS(P<0.05).ROC analysis showed that TyG index had a certain predictive value for the evaluation of GLS<18%(AUC=0.678,95%CI 0.591-0.765,P<0.001).Stratification based on hypertension and further adjusting for confounding factors,TyG index remains significantly associated with GLS<18%(OR=3.249,95%CI 1.045-10.103,P=0.042).Conclusions The novel simplified insulin resistance evaluation indexes are closely associated with left ventricular subclinical systolic dysfunction in T2DM patients with preserved ejection fraction.TyG index is an effective index to identify left ventricular subclinical dysfunction in these populations.
6.Study on fatigue vibration evaluation of ultrasonic knife tip based on Q factor
Ke-Sheng WANG ; Ze-Kai LI ; Pei LIU ; Jing-Sheng SUN ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(6):17-22
Objective To propose a Q factor-based fatigue vibration evaluation method of the ultrasonic knife tip.Methods Firstly,an ultrasonic cutter fatigue testing table was established to realize repeated cutting,which was composed of a power supply module,a three-axis moving module,an ultrasonic cutter clamping module and a control module.Secondly,10 ultrasonic knives of some brand underwent fatigue testing with the table,during which non-contact measurement of the ultrasonic knife tip vibration was carried out and the Q factors were calculated at the five periods of the fatigue test,including the periods before cutting,after 500 times of cutting,after 1 000 times of cutting,after 2 000 times of cutting and after 3 000 times of cutting.Finally,the average cutting speed and burst pressure for coagulated vessels were computed at each period to validata the effectiveness of the method proposed.Results It's indicated that Q factor could effectively reflect the fatigue degradation of the ultrasonic knife tip,while the average cutting speed and burst pressure for coagulated vessels were difficult to efficiently evaluate the fatigue degradation level of the ultrasonic knife tip due to the uncertainty factors in the measurement process.Conclusion The proposed Q factor-based evaluation method can directly evaluate fatigue vibration of the ultrasonic knife tip in an accurate and quantitative manner.[Chinese Medical Equipment Journal,2024,45(6):17-22]
7.Accurate quantitative evaluation of MRI scanning noise based on laser vibrometry technology
Ke-Sheng WANG ; Pei-Jia XU ; Pei LIU ; Jing-Sheng SUN ; Ze-Kai LI ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(10):20-24
Objective To carry out accurate quantative evaluation of MRI scanning noise based on laser vibrometry technology.Methods Skull and spine MRI was performed with mute and conventional sequences.A laser vibrometry device was used to sample the surface vibration noise at the outer edge of the inspection hole of MRI system according to GB/T 16539-1996 Acoustics—Determination of sound power levels of noise sources using vibration velocity—Measurement for seal machinery,and the indicators of sound power level,sound pressure level and perceived noise level obtained by the three calculation methods(LPN1,LPN2 and LPN3)were analyzed with some dedicated MRI noise analysis software.Results The peak sound pressure levels for conventional and mute sequences of skull scanning were 81 and 63 dB(A),respectively,and mute sequence reduced the noise level significantly;the peak sound pressure levels for conventional and mute sequences of spine scanning were 79 and 75 dB(A),respectively,and the noise reduction level was significantly lower than that of skull scanning.Significant differences in noise reduction were not found in spine scanning sequences,while were found in skull scanning sequences.During spine and skull scanning LPN1,LPN2 and LPN3 obtained by the three calculation methods of conventional and mute sequences were all higher than the overall sound power and overall pressure levels obviously.Conclusion Mute sequence can not realize linear noise reduction for the whole frequency band,the perceived noise of the human ear during MRI scanning is related directly to the scanning sequence,and there may be some bias when only one physical indicator is involved in the noise evaluation of MRI system.[Chinese Medical Equipment Journal,2024,45(10):20-24]
8.Improved YOLOv5s-based lesion area detection method for ophthalmic ultrasound images
You ZHOU ; Ze-Meng LI ; Xin-Qi YU ; Xiao-Chun WANG ; Sheng ZHOU
Chinese Medical Equipment Journal 2024;45(11):1-7
Objective To propose an improved YOLOv5s-based lesion area detection method for ophthalmic ultrasound images so as to solve the problems due to high complexity,difficult deployment and low accuracy of the model during ophthalmic ultrasound imaging detection and diagnosis.Methods Firstly,an ophthalmic ultrasound image dataset was established contai-ning Lhe images of stellate vitreous degeneration,retinal detachment,vitreous hemorrhage,posterior vitreous detachment and posterior scleral staphyloma.Secondly,a YOLOv5s-MobileNetV2 model was constructed based on YOLOv5s with the original backbone feature extraction network CSPDarkNet replaced by the lightweight network MobileNet.Thirdly,the model's performance in recognizing lesion areas in ophthalmic ultrasound images was evaluated by multi-category mean average precision(mAP),number of parameters and frames per second(FPS).Finally,the intelligent detection software for ophthalmic ultrasound images was designed based on PyQt5 library.Results The YOLOv5s-MobileNetV2 model had the mAP,number of parameters and FPS being 97.73%,4.61×106 and 47 f/s respectively,which gained advantages in timeliness over YOLOv5s by decreasing the mAP by 0.22%and the number of parameters by 34.98%.The developed intelligent detection software for ophthalmic ultrasound images behaved in human-computer interaction and clinical applicability of YOLOv5s-MobileNetV2 model.Conclusion The improved YOLOv5s-based lesion area detection method for ophthalmic ultrasound images meets clinical diagnosis requirements for ophthalmic diseases by involving in lightweight models and detecting lesion areas accurately.[Chinese Medical Equipment Journal,2024,45(11):1-7]
9.Application of Hisense computer-assisted surgery system in perioperative period of laparoscopic hepatectomy for liver cancer
Xin-Yu LI ; Zi-Qi ZANG ; Qi-Sheng HAO ; Li-Chao CHA ; Ming-Kai GONG ; Guo-Fei DONG ; Qing-Ze LI ; Lan-Tian TIAN
Chinese Journal of Current Advances in General Surgery 2024;27(6):435-441
Objective:To explore the clinical application of Hisense Computer-Assisted Sur-gery System(CAS)in the perioperative period of hepatectomy for liver cancer.Methods:Clinical data of patients undergoing laparoscopic hepatectomy(LH)for liver cancer from January 2021 to December 2022 were collected.Patients were divided into three groups based on surgical difficulty(low,medium,high)and further stratified into CAS-assisted subgroup and control subgroup ac-cording to whether the CAS system was used.Demographic and perioperative data were com-pared among different groups.Results:A total of 317 patients'clinical data were collected,in-cluding 31 cases in the low difficulty group,132 cases in th medium difficulty group,and 154 cases in the high difficulty group,with 108 cases(34.1%)in the CAS-assisted subgroup and 209 cases(65.9%)in the control group.In the medium difficulty group,the CAS-assisted subgroup had shorter operation time,drainage tube duration,and postoperative hospital stay compared to the control group(P<0.001),and the AFP levels at 1 month postoperatively in the CAS-assisted sub-group were lower than those in the control group(P<0.001).In the high difficulty group,the CAS-assisted subgroup showed shorter operation time,drainage tube duration,and postoperative hospi-tal stay,less intraoperative blood loss,and lower AFP levels 1 month post-operation compared to the control group(P<0.001 for all).Conclusion:Preoperative CAS in medium and high difficulty laparoscopic liver resections improves perioperative outcomes.Hisense CAS effectively assists general surgeons in accurately identifying the anatomical site of liver tumors,providing precise pre-operative simulation and intraoperative navigation,thereby optimizing surgical strategies for pa-tients.
10.Synthesis of phenylacetamide derivatives and their protective effects on islet cell damage induced by palmitic acid
Ai-Yun LI ; Li GUAN ; Wan-Zhen SU ; Yang-Yang LU ; Sheng-Jie ZHANG ; Wei-Ze LI ; Xiang-Ying JIAO
Chinese Pharmacological Bulletin 2024;40(6):1130-1136
Aim To design and synthesize a series of phenylacetamide derivatives with different substituted phenylacetic acid as raw materials,and to investigate the protective effects of the compound on the damage of pancreatic β cells induced by palmitate acid(PA).Methods Min6 cells were cultured and divided into B blank control group,PA treatment group and PA+compounds group.The viability of Min6 cells was de-tected by CCK-8.The protein expressions of TXNIP and NLRP3 were observed by Western blot.MDA con-tent and SOD activity were detected by MDA and SOD kit.The insulin secretion of Min6 islet cells was meas-ured with insulin ELISA kit.Results A total of 10 phenylacetamide derivatives were designed and synthe-sized.Their structures were confirmed by 1H NMR and ESI-MS.Pharmacological activity study showed that most of the compounds had protective effects on islet βcells,among which LY-6 and LY-8 had stronger pro-tective effects than PA model group,with the cell via-bility of 61.4%,and LY-6 had the highest cell activi-ty,reaching to 104.9%.Compared with PA group,the protein expression of TXNIP and NLRP3 decreased in LY-6 and LY-8 groups,MDA content decreased and SOD activity increased,and insulin secretion of Min6 cell increased.Conclusions LY-6 and LY-8 inhibit TXNIP expression and decrease the activation of NL-RP3 inflammasome,and decrease the production of MDA and increase SOD activity,and thus reducing is-let β cells apoptosis and increasing insulin secretion.Therefore,the compound LY-6 could serve as a poten-tial anti-diabetic new chemical entity.

Result Analysis
Print
Save
E-mail