1.Microscope-assisted minimally invasive flap periodontal bone grafting for mandibular molar grade Ⅱ furcation defects
HUANG Rongyu ; GAO Li ; LUO Qi ; XIAO Jianhao ; MA Shanshan ; BAI Ruiqi
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(9):765-772
		                        		
		                        			Objective:
		                        			To investigate the clinical efficacy of oral microscope-assisted microflap periodontal bone grafting in treating class Ⅱ furcation involvement in mandibular molars, and to provide clinical evidence for its treatment in furcation involvement.
		                        		
		                        			Methods:
		                        			This study was reviewed and approved by the institutional ethics committee, and informed consent was obtained from all patients. Sixty mandibular molars with class II furcation involvement caused by periodontitis were enrolled in a randomized controlled clinical study, utilizing a random number table method. Patients were categorized into a control group (n=30) and an experimental group (n=30) based on the surgical procedure employed. The control group underwent periodontal flap surgery with an internal oblique incision and vertical incision; this procedure was performed without the aid of a microscope. Conversely, the experimental group underwent micro flap periodontal bone grafting surgery without vertical incision; an oral microscope was used for this procedure. Both groups were analyzed 6 months after surgery, and postoperative gingival recession (GR), probing depth (PD), bleeding index (BI), vertical bone height increase (VBHI), pain level, and complications were recorded.
		                        		
		                        			Results:
		                        			Both groups showed improvement in PD and BI after 6 months compared to preoperative levels: the control group had a preoperative PD of (7.33 ± 1.72 mm) and a 6-month postoperative PD of (3.37 ± 0.96 mm), with statistically significant differences (P<0.001). The preoperative PD of the experimental group was (7.27 ± 1.57 mm), and the 6-month postoperative PD was (3.00 ± 0.69 mm), with statistically significant differences (P<0.001). The BI of the control group decreased from 3.03 ± 1.03 before surgery to 0.77 ± 0.82 at 6 months after surgery (P<0.001), while the BI of the experimental group decreased from 3.20 ± 1.09 before surgery to 0.73 ± 0.64 at 6 months after surgery (P<0.001), and the differences were statistically significant. The experimental group showed a significant improvement in GR (0.70 ± 0.59 mm) compared to preoperative GR (1.26 ± 0.94 mm) at 6 months after surgery (P=0.007), while the control group showed an increase in GR (1.37 ± 0.89 mm) at 6 months after surgery compared to preoperative GR (1.13 ± 0.97 mm), but the difference was not statistically significant (P=0.337). The inter group comparison results showed that there were no statistically significant differences in PD and BI between the two groups at 6 months after surgery (PD: P=0.096, BI: P=0.861); The GR of the experimental group was lower than that of the control group, and the difference was statistically significant (P=0.001). There was no statistically significant difference in postoperative VBHI between the two groups (P=0.128). The pain level scores of the experimental group were lower than those of the control group at 4 and 24 hours after surgery (P<0.001). None of the patients experienced complications.
		                        		
		                        			Conclusion
		                        			Microflap periodontal bone grafting assisted by an oral microscope effectively improves the periodontal condition of patients with grade Ⅱ root bifurcation lesions of mandibular molars, and the bone grafting effect is good, with mild pain and good safety.
		                        		
		                        		
		                        		
		                        	
2.Principles of managing wards for patients with internal radionuclide contamination
Fan BAI ; Chao YANG ; Lei ZHU ; Minghao LIU ; Danjie LIU ; Xiaoxin LIU ; Shanshan GUO ; Jianan WANG
Chinese Journal of Radiological Health 2025;34(3):444-449
		                        		
		                        			
		                        			Based on current national policies, regulations, standards, relevant literature, and departmental experience regarding the protection against radionuclides in China, this study provides a brief overview of key issues in the management of hospital wards for patients with internal radionuclide contamination. The discussion covers the detection of internal contamination, general requirements for internal radionuclide contamination wards, and inpatient management. In addition, the study explores in depth the daily responsibilities, protective measures, and management protocols for both healthcare staff and patients within such wards. This article summarizes a framework for the construction of internal radionuclide contamination wards, along with specific plans and detailed role-based guidelines. These results provide a reference for the management of hospital wards for patients with internal radionuclide contamination.
		                        		
		                        		
		                        		
		                        	
3.Exploration of the comprehensive management practice pathway for long-term prescription medications in psychiatry
Mengxi NIU ; Pengfei LI ; Xue WANG ; Shanshan LIU ; Yanxiang CAO ; Hongyan ZHUANG ; Hu WANG ; Li BAI ; Huawei LI ; Fei PAN ; Sha SHA ; Qing’e ZHANG
China Pharmacy 2025;36(19):2366-2371
		                        		
		                        			
		                        			OBJECTIVE To explore comprehensive management and potential issues associated with long-term prescriptions medications of psychiatry, in order to provide a reference for the comprehensive management of long-term prescriptions of psychiatry in psychiatric hospitals and other medical institutions’ pharmacies. METHODS Starting from the applicable principles for long-term prescriptions of psychiatry, this study introduced the standardized assessment and precautions before issuing long-term prescriptions, the formulation and adjustment of the drug list, as well as the rational management of the long-term prescriptions. It also analyzed potential issues that may arise in the comprehensive management of long-term prescription medications and proposed corresponding countermeasures and suggestions. RESULTS & CONCLUSIONS Prior to initiating long-term prescriptions, a standardized assessment should be conducted on patients from the aspects of their psychiatric condition and long-term potential risk factors, pharmacological treatment plans and other non-pharmacological therapies, physical illnesses. Additionally, healthcare providers should fulfill their obligation to inform patients or their family members. The comprehensive management of long-term prescription medications should be jointly established and improved by multiple departments, and the formulation of drug catalogs should avoid including drugs with potential social harm or medication risks while complying with policy requirements. Furthermore, measures such as adding special identifiers to long-term prescriptions, providing patients with reminders about (No.YGLX202537) prescription expiration, or offering online consultations can also effectively enhance the rationality of medication use under long-term prescriptions. Currently, the implementation of long-term prescriptions in psychiatry remains challenged by inconsistencies in prescription duration, incomplete coverage of diagnostic categories, poor patient adherence, and the risk of deviation in clinical assessments. In this regard, measures such as collaborating with multiple departments to strengthen long-term prescription information management, providing matching pharmaceutical services, ensuring the quality and rationality of long-term prescription implementation, and using modern methods to screen high-risk patients can be taken to improve patient medication compliance and safety.
		                        		
		                        		
		                        		
		                        	
4.Metanephric stromal tumor in children with BRAF V600E gene mutation: a case report and literature review
Shuting MAO ; Dao WANG ; Bai LI ; Shanshan LIU ; Linlin WEI ; Shufang SU ; Yan XU ; Ya′nan MA ; Ge ZHOU ; Yufeng LIU
Chinese Journal of Applied Clinical Pediatrics 2024;39(4):306-310
		                        		
		                        			
		                        			The clinical data of one child with metanephric stromal tumor (MST) and BRAF V600E gene mutation admitted to the First Affiliated Hospital of Zhengzhou University in June 2022 was analyzed retrospectively.Literature was reviewed.The patient, a 2-year-old girl, was diagnosed with a tumor in the left abdomen.The maximum diameter of the tumor was 10.5 cm.A radical nephrectomy was performed on the left kidney, and postoperative pathology revealed MST.Microscopically, the tumor had no envelope and exhibited expansive growth.The tumor cells were fusiform or stellate, and nuclear division was visible in the cell-rich region.Dysplastic blood vessels were seen inside the tumor.The tumor cells around the blood vessels and invaginated renal tubules were arranged like onion skin.CD34 was detected positive by immunohistochemical staining, and BRAF V600E mutation was also detected positive by fluorescent polymerase chain reaction.A total of 21 relevant case reports were retrieved, including 16 in English and 5 in Chinese.Fifty-eight MST patients, including the one in this report were analyzed.These patients were aged 2 days to 15 years, with a median age of 2 years.Except for 2 patients with unknown sex, the ratio of male to female was about 1.4∶1.0.Most MST patients were asymptomatic, with an average tumor size of 5.3 cm.The tumor cell CD34 showed positive expression in different degrees.Eight patients received the BRAF V600E mutation detection, and the results were all positive.Fifty-eight patients underwent nephrectomy and were followed up for 0-156 months, of which 7 patients were assisted with radiotherapy and chemotherapy.During the follow-up, 1 patient died, and 1 patient had a relapse.MST is a rare benign renal stromal tumor. BRAF V600E mutations are detected in a variety of malignancies.This paper is the first to report MST with BRAF V600E mutation in China and points out the importance of molecular detection of BRAF mutation for accurate diagnosis of MST.
		                        		
		                        		
		                        		
		                        	
5.Development of a new type of detection window protective device for surface contamination monitor
Lei ZHU ; Minghao LIU ; Shanshan GUO ; Fan BAI ; Chao YANG ; Tao YAN
China Medical Equipment 2024;21(3):144-147,173
		                        		
		                        			
		                        			Objective:To develop a new type of detection window protective device for surface contamination monitor,and to verify its testing effect.Methods:The new type of surface contamination monitor detection window protection device was composed of the protective film and fixed frame,which was of integrated design and one-off production.The protective film was made of transparent flat Myra film,thickness≤2.5μm,the fixed frame was a rectangular hollow structure surrounded by four edges and provided with a working surface and a mounting surface.The protective film was pasted on the inner wall of the working surface of the fixed frame by adhesive,and the protective film and fixed frame were installed on the outside of the detection window of the surface contamination monitor by means of fixing buckles.Two commonly used surface contamination detection instruments,RDa150 and Como170,were selected to measure artificial radiation sources under three protection states:no film protection,plastic wrap protection and new protection device to test the detection efficiency and operability of the new surface contamination monitor's detection window protection device.Results:Compared with the traditional protective measures of plastic wrap,the detection efficiency of α,β and γ rays was more effectively ensured by the new detection window protective device for surface contamination monitor,and the detection efficiency of α rays was increased from about 40%to about 70%.Conclusion:The new detection window protection device for surface contamination monitor can significantly improve the detection efficiency of radioactive contamination,especially alpha-ray pollution,and effectively protect the instrument and equipment,and effectively improve the detection efficiency of surface contamination detection operators.
		                        		
		                        		
		                        		
		                        	
6.Value of the TyG index for predicting recurrence after catheter ablation in persistent atrial fibrillation patients combined with non-alcoholic fatty liver disease
Shanshan QI ; Qi LIANG ; Yihui XIAO ; Ling BAI ; Hang YU
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(6):954-959
		                        		
		                        			
		                        			[Objective] To explore the value of the TyG index for predicting postoperative recurrence in persistent atrial fibrillation (AF) patients combined with on-alcoholic fatty liver disease (NAFLD) undergoing catheter ablation. [Methods] This study was a single-center, retrospective, cohort study. Clinical data of patients who underwent catheter ablation during hospitalization or outpatient visits at The First Affiliated Hospital of Xi’an Jiaotong University from January 2021 to December 2022 were retrospectively collected. The patients were divided into recurrence and non-recurrence groups based on whether AF recurred within 1 year after the procedure. General clinical data and relevant laboratory test results were collected, and the preoperative TyG index was calculated. The risk factors for AF recurrence after catheter ablation in these patients were analyzed using univariate and multivariate COX proportional hazards regression models. The value of the TyG index for predicting AF recurrence was assessed using receiver operating characteristic (ROC) curve analysis. [Results] We recruited 167 patients, among whom 103 were males and 64 were females. The mean follow-up time was 12±1.3 months, with 52 cases of AF recurrence and 115 ones of non-recurrence. Compared with the non-recurrence group, the TyG index was higher in the recurrence group (9.62±0.96 vs. 8.26±0.46, P<0.05). Multivariate COX regression analysis showed that the preoperative TyG index (HR=1.35, 95% CI: 1.10-1.60, P<0.05) and postoperative electrocardiogram P-wave dispersion (HR=1.51, 95% CI: 1.32-1.70, P<0.001) were risk factors for AF recurrence after catheter ablation in persistent AF patients with NAFLD. The ROC curve analysis showed that the area under the curve (AUC) for the TyG index in predicting AF recurrence after catheter ablation in these patients was 0.846 (95% CI: 0.773-0.919, P<0.001). [Conclusion] The TyG index is an effective indicator for predicting atrial fibrillation recurrence after catheter ablation in persistent AF patients combined with NAFLD.
		                        		
		                        		
		                        		
		                        	
7.Prognostic value of neuroimaging in successful revascularization of acute vertebrobasilar artery occlusion
Bofeng BAI ; Lixue WANG ; Shanshan HUANG ; Yongbin LI ; Zhuozhao ZHENG
Journal of Practical Radiology 2024;40(6):875-879
		                        		
		                        			
		                        			Objective To explore the prognostic value of neuroimaging score in patients with acute vertebrobasilar artery occlusion(VBAO)with successful revascularization.Methods A total of 83 patients with acute VBAO who underwent endovascular treatment with successful recanalization,modified thrombolysis for cerebral infarction grade 2b or 3 were retrospectively selected.Based on baseline diffusion weighted imaging(DWI)sequences,posterior circulation infarcts were assessed using the novel posterior circulation score(N-PCS),brainstem score(BSS),and posterior circulation Alberta stroke program early CT score(pc-ASPECTS).A 90 d modified Rankin scale(mRS)score ≤2 points was defined as functional independence.The predictive value of the three scores was assessed by the receiver operating characteristic(ROC)curve analysis.Results The N-PCS[median(interquartile range):2(1-2)vs 4(2-5)]was statistically significant between the functional independent group(50 cases)and the poor group(33 cases)(P<0.001).Multifactorial logistic regression analysis showed that age[adjusted odds ratio(OR)1.08;95%confidence interval(CI)1.02-1.14;P=0.006],baseline National Institutes of Health Stroke Scale(NIHSS)(adjusted OR 1.12;95%CI 1.03-1.20;P=0.005),and N-PCS(adjusted OR 2.84;95%CI 1.30-6.19;P=0.009)were independent prognostic factors for a favorable prognosis.Conclusion The N-PCS based on DWI can predict the prognosis of acute VBAO patients with successful revascularization.
		                        		
		                        		
		                        		
		                        	
8.Study on the individualized dose verification of patients with CyberKnife treatment based on dose verification system of SRS MapCHECK matrix
Hanshun GONG ; Shanshan GU ; Shaojuan WU ; Jinglin SUN ; Pengfei XU ; Xiaoliang LIU ; Jingmin BAI ; Chuanbin XIE
China Medical Equipment 2024;21(7):17-22
		                        		
		                        			
		                        			Objective:A dose verification system of two-dimensional semiconductor matrix(SRS MapCHECK)was used to verify the dose of the clinical treatment plan of patients who underwent CyberKnife(CK),which realized rapid verification for individualization of radiotherapy plans of patients through analyzed the γ-passing rates of them.Methods:A total of 253 patients with tumor who received CK clinical treatment in the First Medical Center of Chinese PLA General Hospital from March 2021 to May 2023 were selected.Among of them,121 cases received CK treatment on head,and 30 cases received that on lung,and 102 cases received CK treatment on abdomen and other metastatic tumor.In the MultiPlan treatment plan system,the plan of patient was mapped to the integrated model composed of StereoPHAN model and SRS MapCHECK matrix dose verification system by the means of the plan image center overlap.The dose verification was conducted on the plan of each patient on the basis of ensuring the consistency of the number of beam,direction of beam and the monitor unit.The different γ analysis standards(1%/1 mm,2%/1 mm,3%/1 mm,1%/2 mm,2%/2 mm,3%/2 mm,1%/3 mm,2%/3 mm and 3%/3 mm)were adopted to conduct global analysis of absolute dose for each verification plan,and the threshold(TH)of low dose was set as 10%.Results:The γ passing rates of phantom verification plans of 253 patients were respectively(88.64±5.91)%,(95.43±3.40)%,(97.90±2.06)%,(96.51±2.35)%,(98.15±1.68)%,(99.06±1.12)%,(98.30±1.39)%,(99.09±0.97)%and(99.52±0.63)%under different analysis standards.The γ passing rates of other standards of patients with tumor on different parts were larger than 95%except the analysis result of 1%1 mm standard.The overall analysis result of the deviation of central point dose was(-1.30±2.17)%,among of which the tumor of head,abdominal tumors and other metastatic tumor were about approximately-2%,while that of lung tumors were approximately-3%.The deviation of abdominal and other metastatic tumor was the minimum.The correlation analysis showed that the target volume and the size of the minimum collimator were respectively correlated to the dose deviation of the center.Conclusion:SRS MapCHECK dose verification system can conveniently and quickly realize the individualized verification for the plan of patients who receive CK treatment.
		                        		
		                        		
		                        		
		                        	
9.Development of a new type of detection window protection device for wound contamination detector
Lei ZHU ; Shanshan GUO ; Fan BAI ; Minghao LIU ; Chao YANG ; Tao YAN
China Medical Equipment 2024;21(9):168-170,177
		                        		
		                        			
		                        			In order to maximize the detection efficiency of the surface contamination detector on α rays and make up for the problems of insufficient protective measures of the detector,a new detection window protection device for wound contamination detector was designed.The device was consisted of a protective film and a fixed frame sleeve.The protective film was made of a transparent flat Mylar film with a thickness of≤2.5 μm and a circular shape.Its diameter matched the detection surface diameter of the wound radiation measuring instrument probe and can be used in combination with the appropriate model of wound radiation measuring instrument probe.The sleeve was provided with a closed end and an open end,the protective film was fixed on the inner side of the closed end of the sleeve,and the open end of the sleeve was provided with an annular fixing buckle,so that the sleeve can be firmly installed on the probe of the disposable wound radiation measuring instrument.After installation,the protective film can be closely attached to the detection surface of the probe of the wound radiation measuring instrument.Two commonly used contamination detectors were selected to measure the artificial radioactive sources under three protection conditions:film-free protection,plastic wrap protection and new protective devices,and the detection efficiency and operability of the detection window protection device of the new wound contamination detector were tested.The results showed that compared with the traditional protective measures of plastic wrap,the new device can significantly improve the detection efficiency of wound radioactive contamination,especially α contamination,and effectively protect the instrument and equipment,and improve the detection efficiency of wound pollution operators.
		                        		
		                        		
		                        		
		                        	
10.Intervention study on the progress of subacute Parkinson's disease in mice with Kangzhen Zhijing spasmodic decoction Ⅰ
Xuechun BAI ; Shuo CHEN ; Shanshan LI ; Qinglin LI
Chinese Journal of Clinical Pharmacology and Therapeutics 2024;29(6):629-636
		                        		
		                        			
		                        			AIM:To observe the intervention ef-fect of Chinese medicine Kangzhen Zhijing spas-modic decoction Ⅰ on the progression of Parkin-son's disease in mice,and to explore the potential mechanism of neuroprotection.METHODS:Thirty-six C57BL/6 mice were randomly divided into con-trol group,model group,drug group and positive drug group.In the model group,the drug adminis-tration group and the positive drug group,1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine(MPTP)(30 mg/kg)was injected intraperitoneally for 5 days to establish the mouse model.The control group was given the same amount of normal saline,the drug administration group was given 1.25 mg/kg,2.5 mg/kg,5 mg/kg dose of Chinese medicine Kang-zhen Zhijing spasmodic DecoctionⅠby gavage,and the positive drug group was given 75 mg/kg Madopar by gavage.Behavioral tests were per-formed on the second day after the administration in each group.Immunopositive cells of Tyrosine hy-droxylase(TH),Amyloid precursor protein(APP),α-synuclein(α-syn)and solute carrier family 6 mem-ber 11(SLC6A11)were detected by immunohisto-chemistry.The protein expressions of TH,APP,α-syn and SLC6A11 in each group were detected by Western blot.RESULTS:It could significantly im-prove the weight loss of mice in the model group,alleviate the decline of autonomic activity in open field test and the decline of coordination ability in pole test and suspension test.In the reverse immu-nohistochemistry and Western Blot experiments,the expressions of TH and SLC6A11 in the brain of the Parkinson's model group were significantly de-creased,and the expressions of APP and α-syn were significantly increased.CONCLUSION:Kang-zhen Zhijing spasmodic decoctionⅠcan significantly improve the behavioral performance of Parkinson's disease mice and effectively improve the reduction of neuronal transmitters.
		                        		
		                        		
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail