1.Evaluation and application of automated quality control of automatic pipeline in clinical biochemical and immunological detection
Li′an HOU ; Xuesong SHANG ; Chaochao MA ; Liangyu XIA ; Li LIU ; Ying ZHANG ; Yujun SU ; Xin LIU ; Ling QIU
Chinese Journal of Laboratory Medicine 2024;47(1):86-93
Objective:To assess the applicability of fully automatic pipeline automated testing for internal quality control (automated quality control).Methods:Stability, assay efficiency and implementation costs of 18 biochemical tests, 5 immunoturbidimetric tests and 11 chemical illuminescent tests in the Department of Laboratory Medicine of Peking Union Hospital from January 2019 to July 2022 were evaluated using automated quality control implementation methods. The detailed method is as follows: quality control materials for biochemical, immunoturbidimetric and chemiluminescent tests were stored in the refrigerator in the pipeline which was controlled by the intermediate software, and were automatically retrieved and tested as pre-set followed by documenting and storing. The quality control setup for the biochemical tests included refreshing quality control materials daily and weekly,both of which were paralleled for 3 months. The on-line storage stability of quality control materials in the pipeline was evaluated by comparing the coefficients of variation ( CV) of the quality control results between the two patterns. Effect of automated quality control application was evaluated using 6 indicators, including the results′ variation of automatically performed and manually performed quality controls, the out-of-controlled rate, the consumption of quality control materials, the change of staff workload, the impact on the testing time of the first sample, and the failure rate of automated quality control. Results:(1) Storage stability of quality control materials in the pipeline: under the pattern of weekly refresh of the biochemical quality control materials, except for total carbon dioxide (TCO 2) (the CVs of low and high level quality control were respectively 20.24% and 21.82%) and sodium (the CV of low level quality control was 1.51%) that were greater than the allowable variation set by the laboratory, the CVs of the rest tests meet the lab requirements on the allowable variations. (2) The results′ variation of quality control in automatically performed and manually performed control patterns: in the patterns of daily refresh of biochemical quality control materials and weekly refresh of immunoturbidimetric and chemiluminescent quality control materials, the CVs of both low and high levels of quality control were lower in the automatically performed control pattern than that in manually performed pattern for 8 chemiluminescent items of dehydroepiandrosterone sulfate, estradiol, follicle stimulating hormone, luteinizing hormone, serum ferritin, serum folic acid, vitamin B12 and testosterone, 3 immunologic items of complement 3, C reactive protein and immunoglobulin G, and 10 biochemical items of alkaline phosphatase, glucose, calcium, chloride, potassium, lactate dehydrogenase, sodium, urea, low density lipoprotein cholesterol, and adenosine deaminase. The out-of-control rates of biochemistry, immunoturbidimetric and chemiluminescence tests in both quality control patterns conformed with the clinical routine work requirements. (3) Comparison of quality control materials′ consumption: compared with manually performed quality control, weekly consumption of automatically performed chemiluminescent quality control materials decreased 37.5% (from 8 ml to 5 ml); weekly consumption of automatically performed immunoturbidimetric quality control materials decreased 33.3% (from 3 ml to 2 ml). (4)Comparison of staff workload and first sample testing time: compared with manually performed quality control, automatical quality control reduced manual work by about 156 steps per week, and the daily initial testing time was earlier by 15 min on average. The failure rate was 54.5% (37/64) during the early-stage application of the automated quality control which dropped to 10.2% (13/128) in the late-stage. Conclusion:The results of automated quality control detected in the pipeline system meet the quality indicators′ requirements of the laboratory, and the application of automated quality control can improve the quality control, save costs, reduce workload, and improve work efficiency.
2.Establishment and evaluation of a rapid PCR-colloidal gold test strip method for the detection of Fritillaria ussuriensis
Yu-he MA ; Cong-hui SHANG ; Qiu-he MA ; Tao LI ; Yue LIU ; Bei-zhen PAN ; Li-jun GAO ; Ming-cheng LI ; Wei XIA ; Yong-mei QU
Acta Pharmaceutica Sinica 2024;59(6):1773-1778
This study design of specific identification primers for the ITS2 sequence of
3.Investigation on vehicle occupant dummy applicability for under-foot impact loading conditions
Teng-Fei TIAN ; Fu-Hao MO ; Hao-Yang SU ; Can HUANG ; Hui ZHAO ; Jun LIU ; Bo SHANG ; Kui LI ; Jin-Long QIU
Chinese Journal of Traumatology 2024;27(4):235-241
Purpose::Under-foot impact loadings can cause serious lower limb injuries in many activities, such as automobile collisions and underbody explosions to military vehicles. The present study aims to compare the biomechanical responses of the mainstream vehicle occupant dummies with the human body lower limb model and analyze their robustness and applicability for assessing lower limb injury risk in underfoot impact loading environments.Methods::The Hybrid III model, the test device for human occupant restraint (THOR) model, and a hybrid human body model with the human active lower limb model were adopted for under-foot impact analysis regarding different impact velocities and initial lower limb postures.Results::The results show that the 2 dummy models have larger peak tibial axial force and higher sensitivity to the impact velocities and initial postures than the human lower limb model. In particular, the Hybrid III dummy model presented extremely larger peak tibial axial forces than the human lower limb model. In the case of minimal difference in tibial axial force, Hybrid III's tibial axial force (7.5 KN) is still 312.5% that of human active lower limb's (2.4 KN). Even with closer peak tibial axial force values, the biomechanical response curve shapes of the THOR model show significant differences from the human lower limb model.Conclusion::Based on the present results, the Hybrid III dummy cannot be used to evaluate the lower limb injury risk in under-foot loading environments. In contrast, potential improvement in ankle biofidelity and related soft tissues of the THOR dummy can be implemented in the future for better applicability.
4.Promoting Reform of Talent Evaluation Based on China Clinical Cases Library of Traditional Chinese Medicine
Kaige ZHANG ; Yong ZHU ; Jisheng WANG ; Liangzhen YOU ; Weijun HUANG ; Jie YANG ; Candong LI ; Genping LEI ; Chuan ZHENG ; Shuzhen GUO ; Longtao LIU ; Zhining TIAN ; Xinping QIU ; Wenli SU ; Zuo LI ; Wei YAN ; Hongcai SHANG ; Xiaoxiao ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(17):220-226
Talents are the main force for the development of traditional Chinese medicine(TCM), and the construction of TCM talents and the reformation of talent evaluation system are essential to promote the inheritance and innovation of TCM. At present, we are still exploring and developing in the fields of the formulation, implementation and evaluation indicators of TCM talent evaluation system. However, there are shortcomings and difficulties. For instance, insufficient stratification in the evaluation, excessive emphasis on the quantity of achievements, neglecting the quality of the achievements and the actual contribution, imperfect assessment indicators, and the weak characteristics of TCM. Therefore, national ministries and commissions have jointly issued a document requesting to break the four only and set a new standard, in order to promote the construction of a scientific and technological talent evaluation system oriented by innovation value, ability and contribution. For the evaluation of TCM clinical talents, China Association for Science and Technology commissioned China Association of Chinese Medicine to build the China Clinical Cases Library of TCM(CCCL-TCM), which aims at collecting the most authoritative and representative TCM clinical cases and exploring the advantages of applying clinical cases as masterpiece of achievement in TCM clinical talents evaluation. CCCL-TCM can promote the construction of a talent evaluation system that is more in line with the development characteristics of TCM industry, and to carry out relevant pilot in TCM colleges and institutions across the country in order to promote the reformation of TCM talent evaluation system.
5.Relationship between three-dimensional measurement of acromion coverage and degenerative full-thickness rotator cuff tears
Gang WANG ; Xuren GAO ; Shang QIU ; Gen LI ; Xichen ZHANG
Chinese Journal of Tissue Engineering Research 2024;28(36):5773-5778
BACKGROUND:Acromion morphology is the most important external factor of degenerative rotator cuff tear,and studies on acromion morphology and acromion coverage have been continuing. OBJECTIVE:To investigate the coverage of acromion on rotator cuff tissue in three-dimensional space,measure coronal and sagittal parameters,and explore the relationship of acromial overhang,acromioglenoid angle and acromial coverage angle with degenerative full-thickness rotator cuff tears. METHODS:A total of 56 patients diagnosed with full-thickness rotator cuff tears by shoulder arthroscopic surgery or MRI in the Affiliated Hospital of Xuzhou Medical University from January 2022 to June 2023 were retrospectively collected as the tear group,while 48 patients with non-rotator cuff tear were included as the control group.Clinical data and chest CT data of the patients of the two groups were collected,and the shoulder blades of the patients were reconstructed using Mimics software.Acromial overhang,acromioglenoid angle and acromial coverage angle were measured in 3-matic software.The differences between the measurement parameters were compared between the two groups.Binary Logistic regression analysis and receiver operating characteristic curve analysis were performed to evaluate the ability of the measurement parameters to predict rotator cuff tear.It is generally believed that the parameter had good diagnostic value when the area under the receiver operating characteristic curve was greater than 0.8. RESULTS AND CONCLUSION:(1)The mean acromial overhang in patients with rotator cuff tears was greater than that in controls(P<0.001).The mean acromial coverage angle was also greater in patients with rotator cuff tears than in controls(P<0.001).There was no significant difference in the acromioglenoid angle between the two groups(P>0.05).(2)Binary Logistic regression analysis showed that acromial overhang and acromial coverage angle were both risk factors for rotator cuff tear(P<0.05).(3)Receiver operating characteristic curve analysis indicated that the areas under the curve of acromial overhang and acromial coverage angle were 0.725 and 0.865,respectively,and the optimal cutoff values were 36.15 mm and 60.65°.(4)The results showed that the acromial overhang and acromial coverage angle were greater in patients with rotator cuff tears than in patients without rotator cuff tears.Both were associated with degenerative full-thickness rotator cuff tears,and they could be used to predict rotator cuff tears,and the acromial coverage angle was more effective in predicting rotator cuff tears.
6.D-shant atrial shunt device implantable in patients with severe pulmonary hypertension and right heart failure:one case report and literature review
Shu-Na XIAO ; Wen-Jie GAO ; Xiao-Ke SHANG ; Chang-Dong ZHANG ; Yu-Cheng ZHONG ; Ying ZHI ; Lin-Li QIU ; Yan-Fei DONG ; Yan HE ; Wei TIAN ; Wen-Wen TANG
Chinese Journal of Interventional Cardiology 2024;32(8):472-477
To evaluate the effectiveness and safety of implantable D-shant atrial shunt device in patients with severe pulmonary arterial hypertension(PAH)and right heart failure.A 53-year-old female patient diagnosed with severe idiopathic PAH and right heart failure,her WHO FC grade was Ⅳ.The right heart catheter and implantation of D-shant atrial shunt device were performed under local anesthesia on November 30,2021.A 6 mm×4 cm peripheral artery balloon was selected to dilate the atrial septum and a D-shant atrial shunt device with a fixed 4 mm diameter orifice was implanted into the heart.The clinical symptoms and hemodynamics of the patient was improved after the intervention.Implantation of atrial shunt device as a palliative therapy to established a right to left shunt is another strategy for treating patients with severe PAH in late period,which has good effectiveness and safety.It could be the last replacement therapy to improve symptoms and prolonged lives to drug resistant and severe PAH patients.
7.Clinical and imaging analysis of COVID-19-related osmotic demyelination syndrome
Yuyue QIU ; Chenhui MAO ; Jialu BAO ; Li SHANG ; Tianyi WANG ; Bo LI ; Yixuan HUANG ; Yuhan JIANG ; Shanshan CHU ; Wei JIN ; Liling DONG ; Feng FENG ; Jing GAO
Chinese Journal of Neurology 2024;57(7):763-769
Objective:To analyze the clinical and imaging features of patients with COVID-19-related osmotic demyelination syndrome (ODS).Methods:COVID-19-related ODS cases diagnosed in the Department of Neurology, Peking Union Medical College Hospital from January 2020 to September 2023 were retrospectively reviewed. And their past medical history, possible triggers, clinical manifestations, imaging manifestations, treatment and prognosis were summarized.Results:A total of 5 patients with COVID-19-related ODS were included. Electrolyte disturbances acted as an inducement of ODS in all patients (5/5),4 of whom with hyponatremia. Four of 5 patients first presented with disturbance of consciousness, followed by predominant dystonia. Imaging of all patients (5/5) showed isolated extrapontine myelinolysis (EPM). With the prolongation of the course of disease, such signal intensity could return to normal, and lesions showed atrophic changes in some patients. The patients′ clinical symptoms were partly relieved within a few days to a few months after treatment.Conclusions:COVID-19-related ODS is mostly associated with hyponatremia, and EPM is more common. COVID-19 should be considered as a risk factor for ODS.
9.Inhibitory effect of three strains of biocontrol microbes on pathogens causing rhizome rot of Polygonatum cyrtonema.
Meng-Qi ZHENG ; Ren-Qiang JIANG ; Wei FANG ; Jia-Yin CHEN ; Meng-Li ZHAO ; Jin-Ping SI ; Ling-Shang WU ; Qiu-Fang XU
China Journal of Chinese Materia Medica 2023;48(5):1212-1217
Rhizome rot is one of the main disease in the cultivation of Polygonatum cyrtonema, and it is also a global disease which seriously occurs on the perennial medicinal plants such as Panax notoginseng and P. ginseng. There is no effective control method at present. To identify the effects of three biocontrol microbes(Penicillium oxalicum QZ8, Trichoderma asperellum QZ2, and Brevibacillus amyloliquefaciens WK1) on the pathogens causing rhizome rot of P. cyrtonema, this study verified six suspected pathogens for their pathogenicity on P. cyrtonema. The result showed that Fusarium sp. HJ4, Colletotrichum sp. HJ4-1, and Phomopsis sp. HJ15 were the pathogens of rhizome rot of P. cyrtonema, and it was found for the first time that Phomopsis sp. could cause rhizome rot P. cyrtonema. Furthermore, the inhibitory effects of biocontrol microbes and their secondary metabolites on three pathogens were determined by confrontation culture. The results showed that the three tested biocontrol microbes significantly inhibited the growth of three pathogens. Moreover, the secondary metabolites of T. asperellum QZ2 and B. amyloliquefaciens WK1 showed significant inhibition against the three pathogens(P<0.05), and the effect of B. amyloliquefaciens WK1 sterile filtrate was significantly higher than that of high tempe-rature sterilized filtrate(P<0.05). B. amyloliquefaciens WK1 produced antibacterial metabolites to inhibit the growth of pathogens, and the growth inhibition rate of its sterile filtrate against three pathogens ranged from 87.84% to 93.14%. T. asperellum QZ2 inhibited the growth of pathogens through competition and antagonism, and P. oxalicum QZ8 exerted the inhibitory effect through competition. The research provides new ideas for the prevention and treatment of rhizome rot of P. cyrtonema and provides a basis for the di-sease control in other crops.
Polygonatum
;
Rhizome
10.Danhong Injection Up-regulates miR-125b in Endothelial Exosomes and Attenuates Apoptosis in Post-Infarction Myocardium.
Si-Nai LI ; Zi-Hao LIU ; Ming-Xue ZHOU ; Wei-Hong LIU ; Xiao-Lei LAI ; Ping LI ; Lei ZHANG ; Ju-Ju SHANG ; Sheng-Lei QIU ; Yan LOU ; Yu-Pei TAN ; Wen-Long XING ; Hong-Xu LIU
Chinese journal of integrative medicine 2023;29(12):1099-1110
OBJECTIVE:
To investigate the involvement of endothelial cells (ECs)-derived exosomes in the anti-apoptotic effect of Danhong Injection (DHI) and the mechanism of DHI-induced exosomal protection against postinfarction myocardial apoptosis.
METHODS:
A mouse permanent myocardial infarction (MI) model was established, followed by a 14-day daily treatment with DHI, DHI plus GW4869 (an exosomal inhibitor), or saline. Phosphate-buffered saline (PBS)-induced ECs-derived exosomes were isolated, analyzed by miRNA microarray and validated by droplet digital polymerase chain reaction (ddPCR). The exosomes induced by DHI (DHI-exo), PBS (PBS-exo), or DHI+GW4869 (GW-exo) were isolated and injected into the peri-infarct zone following MI. The protective effects of DHI and DHI-exo on MI hearts were measured by echocardiography, Masson's trichrome staining, and TUNEL apoptosis assay. The Western blotting and quantitative reverse transcription PCR (qRT-PCR) were used to evaluate the expression levels of miR-125b/p53-mediated pathway components, including miR-125b, p53, Bak, Bax, and caspase-3 activities.
RESULTS:
DHI significantly improved cardiac function and reduced infarct size in MI mice (P<0.01), which was abolished by the GW4869 intervention. DHI promoted the exosomal secretion in ECs (P<0.01). According to the results of exosomal miRNA microarray assay, 30 differentially expressed miRNAs in the DHI-exo were identified (28 up-regulated miRNAs and 2 down-regulated miRNAs). Among them, DHI significantly elevated miR-125b level in DHI-exo and DHI-treated ECs, a recognized apoptotic inhibitor impeding p53 signaling (P<0.05). Remarkably, treatment with DHI and DHI-exo attenuated apoptosis, elevated miR-125b expression level, inhibited capsase-3 activity, and down-regulated the expression levels of proapoptotic effectors (p53, Bak, and Bax) in post-MI hearts, whereas these effects were blocked by GW4869 (P<0.05 or P<0.01).
CONCLUSION
DHI and DHI-induced exosomes inhibited apoptosis, promoted the miR-125b expression level, and regulated the p53 apoptotic pathway in post-infarction myocardium.
Mice
;
Animals
;
Tumor Suppressor Protein p53/metabolism*
;
Endothelial Cells/metabolism*
;
Exosomes/metabolism*
;
bcl-2-Associated X Protein/metabolism*
;
Myocardium/metabolism*
;
Myocardial Infarction/drug therapy*
;
Apoptosis
;
MicroRNAs/metabolism*

Result Analysis