1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
5.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
6.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Primary Cutaneous CD30+ Lymphoproliferative Disorders in South Korea: A Nationwide, Multi-Center, Retrospective, Clinical, and Prognostic Study
Woo Jin LEE ; Sook Jung YUN ; Joon Min JUNG ; Joo Yeon KO ; Kwang Ho KIM ; Dong Hyun KIM ; Myung Hwa KIM ; You Chan KIM ; Jung Eun KIM ; Chan-Ho NA ; Je-Ho MUN ; Jong Bin PARK ; Ji-Hye PARK ; Hai-Jin PARK ; Dong Hoon SHIN ; Jeonghyun SHIN ; Sang Ho OH ; Seok-Kweon YUN ; Dongyoun LEE ; Seok-Jong LEE ; Seung Ho LEE ; Young Bok LEE ; Soyun CHO ; Sooyeon CHOI ; Jae Eun CHOI ; Mi Woo LEE ; On behalf of The Korean Society of Dermatopathology
Annals of Dermatology 2025;37(2):75-85
Background:
Primary cutaneous CD30+ lymphoproliferative disorders (pcCD30-LPDs) are a diseases with various clinical and prognostic characteristics.
Objective:
Increasing our knowledge of the clinical characteristics of pcCD30-LPDs and identifying potential prognostic variables in an Asian population.
Methods:
Clinicopathological features and survival data of pcCD30-LPD cases obtained from 22 hospitals in South Korea were examined.
Results:
A total of 413 cases of pcCD30-LPDs (lymphomatoid papulosis [LYP], n=237; primary cutaneous anaplastic large cell lymphoma [C-ALCL], n=176) were included. Ninety percent of LYP patients and roughly 50% of C-ALCL patients presented with multiple skin lesions. Both LYP and C-ALCL affected the lower limbs most frequently. Multiplicity and advanced T stage of LYP lesions were associated with a chronic course longer than 6 months. Clinical morphology with patch lesions and elevated serum lactate dehydrogenase were significantly associated with LPDs during follow-up in LYP patients. Extracutaneous involvement of C-ALCL occurred in 13.2% of patients. Lesions larger than 5 cm and increased serum lactate dehydrogenase were associated with a poor prognosis in C-ALCL. The survival of patients with C-ALCL was unaffected by the anatomical locations of skin lesions or other pathological factors.
Conclusion
The multiplicity or size of skin lesions was associated with a chronic course of LYP and survival among patients with C-ALCL.
9.Comparison of Physician-Controlled Maneuver and Assistant-Controlled Maneuver during Endoscopic Retrograde Cholangiopancreatography
Min Je SUNG ; Jung Hyun JO ; Hee Seung LEE ; Jeong Youp PARK ; Seungmin BANG ; Moon Jae CHUNG
Yonsei Medical Journal 2024;65(1):34-41
Purpose:
Cannulation of the major papilla is the most challenging part of endoscopic retrograde cholangiopancreatography (ERCP) for which physician-controlled wire-guided cannulation (PCWGC) and assistant-controlled wire-guided cannulation (ACWGC) are used as the cannulation techniques. PCWGC can reportedly save up to about 30% of the labor cost by reducing the number of assistants. This study aims to compare the safety and efficacy of PCWGC and ACWGC.
Materials and Methods:
Of the 2151 patients aged >20 years (4193 cases) who underwent ERCP at Yonsei University Medical Center between January 2015 and December 2016, 989 were included in this study.
Results:
Among efficacy outcomes, cannulation success rate, rate of precut sphincterotomy (PCWGC vs. ACWGC: 21.3% vs.25.9%), bile duct cannulation time (PCWGC vs. ACWGC: median 3.0 minutes vs. 3.6 minutes), and total procedure time (PCWGC vs. ACWGC: median 13.6 minutes vs. 13.1 minutes) were not significantly different. Among safety outcomes, lower rates of postERCP pancreatitis were observed with PCWGC than with ACWGC (PCWGC vs. ACWGC: 5.8% vs. 8.8%, p=0.128). Among other post-ERCP adverse events (bleeding, perforation, and cholangitis), the difference was not significant between the groups. Radiation exposure (total dose area product, PCWGC vs. ACWGC: median 1979.9 µGym2 vs. 2062.0 µGym2 , p=0.194) and ERCP cost excluding labor cost (PCWGC vs. ACWGC: $1576 vs. $1547, p=0.606) were not significantly different.
Conclusion
Requiring less assistants, PCWGC showed comparable efficacy and safety to ACWGC. PCWGC can be considered as an alternative option, especially in facilities lacking manpower and resources.
10.Immune Cells Are DifferentiallyAffected by SARS-CoV-2 Viral Loads in K18-hACE2 Mice
Jung Ah KIM ; Sung-Hee KIM ; Jeong Jin KIM ; Hyuna NOH ; Su-bin LEE ; Haengdueng JEONG ; Jiseon KIM ; Donghun JEON ; Jung Seon SEO ; Dain ON ; Suhyeon YOON ; Sang Gyu LEE ; Youn Woo LEE ; Hui Jeong JANG ; In Ho PARK ; Jooyeon OH ; Sang-Hyuk SEOK ; Yu Jin LEE ; Seung-Min HONG ; Se-Hee AN ; Joon-Yong BAE ; Jung-ah CHOI ; Seo Yeon KIM ; Young Been KIM ; Ji-Yeon HWANG ; Hyo-Jung LEE ; Hong Bin KIM ; Dae Gwin JEONG ; Daesub SONG ; Manki SONG ; Man-Seong PARK ; Kang-Seuk CHOI ; Jun Won PARK ; Jun-Won YUN ; Jeon-Soo SHIN ; Ho-Young LEE ; Ho-Keun KWON ; Jun-Young SEO ; Ki Taek NAM ; Heon Yung GEE ; Je Kyung SEONG
Immune Network 2024;24(2):e7-
Viral load and the duration of viral shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are important determinants of the transmission of coronavirus disease 2019.In this study, we examined the effects of viral doses on the lung and spleen of K18-hACE2 transgenic mice by temporal histological and transcriptional analyses. Approximately, 1×105 plaque-forming units (PFU) of SARS-CoV-2 induced strong host responses in the lungs from 2 days post inoculation (dpi) which did not recover until the mice died, whereas responses to the virus were obvious at 5 days, recovering to the basal state by 14 dpi at 1×102 PFU. Further, flow cytometry showed that number of CD8+ T cells continuously increased in 1×102 PFU-virusinfected lungs from 2 dpi, but not in 1×105 PFU-virus-infected lungs. In spleens, responses to the virus were prominent from 2 dpi, and number of B cells was significantly decreased at 1×105PFU; however, 1×102 PFU of virus induced very weak responses from 2 dpi which recovered by 10 dpi. Although the defense responses returned to normal and the mice survived, lung histology showed evidence of fibrosis, suggesting sequelae of SARS-CoV-2 infection. Our findings indicate that specific effectors of the immune response in the lung and spleen were either increased or depleted in response to doses of SARS-CoV-2. This study demonstrated that the response of local and systemic immune effectors to a viral infection varies with viral dose, which either exacerbates the severity of the infection or accelerates its elimination.

Result Analysis
Print
Save