1.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
2.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
3.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
4.Efficacy and Safety of Metformin and Atorvastatin Combination Therapy vs. Monotherapy with Either Drug in Type 2 Diabetes Mellitus and Dyslipidemia Patients (ATOMIC): Double-Blinded Randomized Controlled Trial
Jie-Eun LEE ; Seung Hee YU ; Sung Rae KIM ; Kyu Jeung AHN ; Kee-Ho SONG ; In-Kyu LEE ; Ho-Sang SHON ; In Joo KIM ; Soo LIM ; Doo-Man KIM ; Choon Hee CHUNG ; Won-Young LEE ; Soon Hee LEE ; Dong Joon KIM ; Sung-Rae CHO ; Chang Hee JUNG ; Hyun Jeong JEON ; Seung-Hwan LEE ; Keun-Young PARK ; Sang Youl RHEE ; Sin Gon KIM ; Seok O PARK ; Dae Jung KIM ; Byung Joon KIM ; Sang Ah LEE ; Yong-Hyun KIM ; Kyung-Soo KIM ; Ji A SEO ; Il Seong NAM-GOONG ; Chang Won LEE ; Duk Kyu KIM ; Sang Wook KIM ; Chung Gu CHO ; Jung Han KIM ; Yeo-Joo KIM ; Jae-Myung YOO ; Kyung Wan MIN ; Moon-Kyu LEE
Diabetes & Metabolism Journal 2024;48(4):730-739
Background:
It is well known that a large number of patients with diabetes also have dyslipidemia, which significantly increases the risk of cardiovascular disease (CVD). This study aimed to evaluate the efficacy and safety of combination drugs consisting of metformin and atorvastatin, widely used as therapeutic agents for diabetes and dyslipidemia.
Methods:
This randomized, double-blind, placebo-controlled, parallel-group and phase III multicenter study included adults with glycosylated hemoglobin (HbA1c) levels >7.0% and <10.0%, low-density lipoprotein cholesterol (LDL-C) >100 and <250 mg/dL. One hundred eighty-five eligible subjects were randomized to the combination group (metformin+atorvastatin), metformin group (metformin+atorvastatin placebo), and atorvastatin group (atorvastatin+metformin placebo). The primary efficacy endpoints were the percent changes in HbA1c and LDL-C levels from baseline at the end of the treatment.
Results:
After 16 weeks of treatment compared to baseline, HbA1c showed a significant difference of 0.94% compared to the atorvastatin group in the combination group (0.35% vs. −0.58%, respectively; P<0.0001), whereas the proportion of patients with increased HbA1c was also 62% and 15%, respectively, showing a significant difference (P<0.001). The combination group also showed a significant decrease in LDL-C levels compared to the metformin group (−55.20% vs. −7.69%, P<0.001) without previously unknown adverse drug events.
Conclusion
The addition of atorvastatin to metformin improved HbA1c and LDL-C levels to a significant extent compared to metformin or atorvastatin alone in diabetes and dyslipidemia patients. This study also suggested metformin’s preventive effect on the glucose-elevating potential of atorvastatin in patients with type 2 diabetes mellitus and dyslipidemia, insufficiently controlled with exercise and diet. Metformin and atorvastatin combination might be an effective treatment in reducing the CVD risk in patients with both diabetes and dyslipidemia because of its lowering effect on LDL-C and glucose.
5.Early Prediction of Mortality for Septic Patients Visiting Emergency Room Based on Explainable Machine Learning: A Real-World Multicenter Study
Sang Won PARK ; Na Young YEO ; Seonguk KANG ; Taejun HA ; Tae-Hoon KIM ; DooHee LEE ; Dowon KIM ; Seheon CHOI ; Minkyu KIM ; DongHoon LEE ; DoHyeon KIM ; Woo Jin KIM ; Seung-Joon LEE ; Yeon-Jeong HEO ; Da Hye MOON ; Seon-Sook HAN ; Yoon KIM ; Hyun-Soo CHOI ; Dong Kyu OH ; Su Yeon LEE ; MiHyeon PARK ; Chae-Man LIM ; Jeongwon HEO ; On behalf of the Korean Sepsis Alliance (KSA) Investigators
Journal of Korean Medical Science 2024;39(5):e53-
Background:
Worldwide, sepsis is the leading cause of death in hospitals. If mortality rates in patients with sepsis can be predicted early, medical resources can be allocated efficiently. We constructed machine learning (ML) models to predict the mortality of patients with sepsis in a hospital emergency department.
Methods:
This study prospectively collected nationwide data from an ongoing multicenter cohort of patients with sepsis identified in the emergency department. Patients were enrolled from 19 hospitals between September 2019 and December 2020. For acquired data from 3,657 survivors and 1,455 deaths, six ML models (logistic regression, support vector machine, random forest, extreme gradient boosting [XGBoost], light gradient boosting machine, and categorical boosting [CatBoost]) were constructed using fivefold cross-validation to predict mortality. Through these models, 44 clinical variables measured on the day of admission were compared with six sequential organ failure assessment (SOFA) components (PaO 2 /FIO 2 [PF], platelets (PLT), bilirubin, cardiovascular, Glasgow Coma Scale score, and creatinine).The confidence interval (CI) was obtained by performing 10,000 repeated measurements via random sampling of the test dataset. All results were explained and interpreted using Shapley’s additive explanations (SHAP).
Results:
Of the 5,112 participants, CatBoost exhibited the highest area under the curve (AUC) of 0.800 (95% CI, 0.756–0.840) using clinical variables. Using the SOFA components for the same patient, XGBoost exhibited the highest AUC of 0.678 (95% CI, 0.626–0.730). As interpreted by SHAP, albumin, lactate, blood urea nitrogen, and international normalization ratio were determined to significantly affect the results. Additionally, PF and PLTs in the SOFA component significantly influenced the prediction results.
Conclusion
Newly established ML-based models achieved good prediction of mortality in patients with sepsis. Using several clinical variables acquired at the baseline can provide more accurate results for early predictions than using SOFA components. Additionally, the impact of each variable was identified.
6.Long Term Clinical Outcomes of Gastric Mucosa-Associated Lymphoid Tissue Lymphoma: A Single Center Study
Seong Hyun KOH ; Seung Hyun YEO ; Moo In PARK ; Kyoungwon JUNG ; Sung Eun KIM ; Won MOON ; Seun Ja PARK
The Korean Journal of Helicobacter and Upper Gastrointestinal Research 2024;24(1):64-71
Objectives:
Few studies have reported long-term follow-up after treatment of gastric mucosaassociated lymphoid tissue (MALT) lymphoma. In this single-center study, we investigated longterm treatment outcomes in patients diagnosed with gastric MALT lymphoma.
Methods:
The study included 80 patients diagnosed with gastric MALT lymphoma, who were followed up at a single center between January 2005 and December 2019 after Helicobacter pylori eradication therapy, radiotherapy, or chemotherapy. We evaluated complete remission, improvement, or recurrence of the lesion. Follow-up over >60 months was classified as long-term follow-up, and the progression-free survival rate was recorded.
Results:
Following H. pylori eradication treatment, complete remission occurred in 85.9% (55/64) of H. pylori-positive and 50.0% (3/6) of H. pylori-negative patients. All patients with gastric MALT lymphoma who did not respond to H. pylori eradication therapy (100.0% [6/6]) achieved complete remission following administration of local radiotherapy. We observed no deaths on long-term follow-up (>60 months), and the progression-free survival was 101 months.
Conclusions
In this study, patients with gastric MALT lymphoma showed excellent survival rates, progression-free survival, and prognosis on long-term follow-up. Prospective studies are warranted to determine the long-term prognosis of gastric MALT lymphoma after treatment.
7.Comparative effectiveness of JAK inhibitors and biologic disease-modifying antirheumatic drugs in patients with rheumatoid arthritis
Soo-Kyung CHO ; Hyoungyoung KIM ; Yeo-Jin SONG ; Hye Won KIM ; Eunwoo NAM ; Shin-Seok LEE ; Hye-Soon LEE ; Sung-Hoon PARK ; Yeon-Ah LEE ; Min-Chan PARK ; Sung Hae CHANG ; Hyoun-Ah KIM ; Seung-Ki KWOK ; Hae-Rim KIM ; Hyun-Sook KIM ; Bo Young YOON ; Wan-Sik UHM ; Yong-Gil KIM ; Jae Hoon KIM ; Jisoo LEE ; Jeongim CHOI ; Yoon-Kyoung SUNG
The Korean Journal of Internal Medicine 2023;38(4):546-556
Background/Aims:
We aimed to compare the effectiveness and safety of Janus kinase inhibitors (JAKi) vs. biologic disease- modifying antirheumatic drugs (bDMARD) in Korean patients with rheumatoid arthritis (RA) who had an inadequate response to conventional synthetic DMARDs.
Methods:
A quasi-experimental, multi-center, prospective, non-randomized study was conducted to compare response rates between JAKi and bDMARDs in patients with RA naïve to targeted therapy. An interim analysis was performed to estimate the proportion of patients achieving low disease activity (LDA) based on disease activity score (DAS)–28– erythroid sedimentation rate (ESR) (DAS28-ESR) at 24 weeks after treatment initiation and to evaluate the development of adverse events (AEs).
Results:
Among 506 patients enrolled from 17 institutions between April 2020 and August 2022, 346 (196 JAKi group and 150 bDMARD group) were included in the analysis. After 24 weeks of treatment, 49.0% of JAKi users and 48.7% of bDMARD users achieved LDA (p = 0.954). DAS28-ESR remission rates were also comparable between JAKi and bDMARD users (30.1% and 31.3%, respectively; p = 0.806). The frequency of AEs reported in the JAKi group was numerically higher than that in the bDMARDs group, but the frequencies of serious and severe AEs were comparable between the groups.
Conclusions
Our interim findings reveal JAKi have comparable effectiveness and safety to bDMARDs at 24 weeks after treatment initiation.
8.Erratum: Correction of Affiliationsin the Article “Validity of Outcome Prediction Scoring Systems in Korean Patients with Severe Adult Respiratory Distress Syndrome Receiving Extracorporeal Membrane Oxygenation Therapy”
Seunghyun LEE ; Hye Ju YEO ; Seong Hoon YOON ; Seung Eun LEE ; Woo Hyun CHO ; Doo Soo JEON ; Yun Seong KIM ; Bong Soo SON ; Do Hyung KIM
Journal of Korean Medical Science 2023;38(42):e380-
9.Clinical Practice Guidelines for Oropharyngeal Dysphagia
Seoyon YANG ; Jin-Woo PARK ; Kyunghoon MIN ; Yoon Se LEE ; Young-Jin SONG ; Seong Hee CHOI ; Doo Young KIM ; Seung Hak LEE ; Hee Seung YANG ; Wonjae CHA ; Ji Won KIM ; Byung-Mo OH ; Han Gil SEO ; Min-Wook KIM ; Hee-Soon WOO ; Sung-Jong PARK ; Sungju JEE ; Ju Sun OH ; Ki Deok PARK ; Young Ju JIN ; Sungjun HAN ; DooHan YOO ; Bo Hae KIM ; Hyun Haeng LEE ; Yeo Hyung KIM ; Min-Gu KANG ; Eun-Jae CHUNG ; Bo Ryun KIM ; Tae-Woo KIM ; Eun Jae KO ; Young Min PARK ; Hanaro PARK ; Min-Su KIM ; Jungirl SEOK ; Sun IM ; Sung-Hwa KO ; Seong Hoon LIM ; Kee Wook JUNG ; Tae Hee LEE ; Bo Young HONG ; Woojeong KIM ; Weon-Sun SHIN ; Young Chan LEE ; Sung Joon PARK ; Jeonghyun LIM ; Youngkook KIM ; Jung Hwan LEE ; Kang-Min AHN ; Jun-Young PAENG ; JeongYun PARK ; Young Ae SONG ; Kyung Cheon SEO ; Chang Hwan RYU ; Jae-Keun CHO ; Jee-Ho LEE ; Kyoung Hyo CHOI
Journal of the Korean Dysphagia Society 2023;13(2):77-106
Objective:
Dysphagia is a common clinical condition characterized by difficulty in swallowing. It is sub-classified into oropharyngeal dysphagia, which refers to problems in the mouth and pharynx, and esophageal dysphagia, which refers to problems in the esophageal body and esophagogastric junction. Dysphagia can have a significant negative impact one’s physical health and quality of life as its severity increases. Therefore, proper assessment and management of dysphagia are critical for improving swallowing function and preventing complications. Thus a guideline was developed to provide evidence-based recommendations for assessment and management in patients with dysphagia.
Methods:
Nineteen key questions on dysphagia were developed. These questions dealt with various aspects of problems related to dysphagia, including assessment, management, and complications. A literature search for relevant articles was conducted using Pubmed, Embase, the Cochrane Library, and one domestic database of KoreaMed, until April 2021. The level of evidence and recommendation grade were established according to the Grading of Recommendation Assessment, Development and Evaluation methodology.
Results:
Early screening and assessment of videofluoroscopic swallowing were recommended for assessing the presence of dysphagia. Therapeutic methods, such as tongue and pharyngeal muscle strengthening exercises and neuromuscular electrical stimulation with swallowing therapy, were effective in improving swallowing function and quality of life in patients with dysphagia. Nutritional intervention and an oral care program were also recommended.
Conclusion
This guideline presents recommendations for the assessment and management of patients with oropharyngeal dysphagia, including rehabilitative strategies.
10.Initial report of extraperitoneal pedicle dissection in deep inferior epigastric perforator flap breast reconstruction using the da Vinci SP
Ji Hyuk JUNG ; Yeo Reum JEON ; Dong Won LEE ; Hyung Seok PARK ; Dae Hyun LEW ; Tae Suk ROH ; Seung Yong SONG
Archives of Plastic Surgery 2022;49(1):34-38
The deep inferior epigastric perforator (DIEP) flap has been widely used for autologous breast reconstruction after mastectomy. In the conventional surgical method, a long incision is needed at the anterior fascia of the rectus abdominis muscle to obtain sufficient pedicle length; this may increase the risk of incisional hernia. To shorten the incision, several trials have investigated the use of endoscopic/robotic devices for pedicle harvest; however, making multiple additional incisions for port insertion and operating in the intraperitoneal field were inevitable. Here, we describe the first case, in which a DIEP free flap was successfully made using the da Vinci SP model. Our findings can help surgeons perform operations in smaller fields with a single port in the extraperitoneal space. Moreover, this method is expected to lead to fewer donor-related complications and faster healing.