1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Sex Differences in Procedural Characteristics and Clinical Outcomes Among Patients Undergoing Bifurcation PCI
Hyun Jin AHN ; Francesco BRUNO ; Jeehoon KANG ; Doyeon HWANG ; Han-Mo YANG ; Jung-Kyu HAN ; Leonardo De LUCA ; Ovidio de FILIPPO ; Alessio MATTESINI ; Kyung Woo PARK ; Alessandra TRUFFA ; Wojciech WANHA ; Young Bin SONG ; Sebastiano GILI ; Woo Jung CHUN ; Gerard HELFT ; Seung-Ho HUR ; Bernardo CORTESE ; Seung Hwan HAN ; Javier ESCANED ; Alaide CHIEFFO ; Ki Hong CHOI ; Guglielmo GALLONE ; Joon-Hyung DOH ; Gaetano De FERRARI ; Soon-Jun HONG ; Giorgio QUADRI ; Chang-Wook NAM ; Hyeon-Cheol GWON ; Hyo-Soo KIM ; Fabrizio D’ASCENZO ; Bon-Kwon KOO
Korean Circulation Journal 2025;55(1):5-16
Background and Objectives:
The risk profiles, procedural characteristics, and clinical outcomes for women undergoing bifurcation percutaneous coronary intervention (PCI) are not well defined compared to those in men.
Methods:
COronary BIfurcation Stenting III (COBIS III) is a multicenter, real-world registry of 2,648 patients with bifurcation lesions treated with second-generation drug-eluting stents.We compared the angiographic and procedural characteristics and clinical outcomes based on sex. The primary outcome was 5-year target lesion failure (TLF), a composite of cardiac death, myocardial infarction, and target lesion revascularization.
Results:
Women (n=635, 24%) were older, had hypertension and diabetes more often, and had smaller main vessel and side branch reference diameters than men. The pre- and post-PCI angiographic percentage diameter stenoses of the main vessel and side branch were comparable between women and men. There were no differences in procedural characteristics between the sexes. Women and men had a similar risk of TLF (6.3% vs. 7.1%, p=0.63) as well as its individual components and sex was not an independent predictor of TLF. This finding was consistent in the left main and 2 stenting subgroups.
Conclusions
In patients undergoing bifurcation PCI, sex was not an independent predictor of adverse outcome.
3.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
4.Identification of de novo BSCL2 Asn88Ser Variant with Atypical Presentation of Distal Hereditary Motor Neuropathy Type 5: Clinical Challenge in Diagnosis of Motor Neuron Diseases
Hyunkee KIM ; Jung Hyun LEE ; Dongju WON ; Jong Rak CHOI ; Ha Young SHIN ; Seung Hyun KIM
Journal of the Korean Neurological Association 2025;43(1):35-39
Diagnosing amyotrophic lateral sclerosis (ALS) is challenging and requires distinguishing it from conditions like distal hereditary motor neuropathy type 5 (dHMN-V). A 21-year-old female initially diagnosed with ALS showed progressive upper limb weakness extending to the lower limbs. Trio exome sequencing revealed a de novo pathogenic Berardinelli-Seip congenital lipodystrophy 2 variant (c.263A>G, p.Asn88Ser), confirming dHMN-V. Minipolymyoclonus of small amplitudes in bilateral wrists and ankles was an atypical presentation. This case underscores the importance of considering dHMN-V as a differential diagnosis in ALS-like distal upper extremity weakness.
5.Clinical Features of Patients who Revisited Our Clinic after 3 Years of Postoperative Intermittent Exotropia Stabilization
Journal of the Korean Ophthalmological Society 2025;66(4):199-204
Purpose:
To analyze the chief complaints and clinical characteristics of patients with intermittent exotropia who voluntarily revisited our clinic more than 3 years after stabilization of bilateral lateral rectus recession.
Methods:
This study retrospectively reviewed the medical records of patients diagnosed with intermittent exotropia who underwent bilateral lateral rectus recession and revisited the outpatient clinic after more than 3 years of follow-up.
Results:
Thirty-two patients were included. The most common reason for voluntary revisit was suspicion of recurrence (n = 21, 65.6%). Reasons for revisit were divided into suspicion of recurrence (exodrift group) and others (no exodrift group). At the revisits, both the distance and near deviation angles of the exodrift group were larger than those of the no exodrift group. For all patients and the exodrift group, both the distance and near deviation angles were higher at the revisits than at the last follow-up visits. For both groups, the near stereoacuity did not differ between the last follow-up visit and the revisit but the spherical equivalent was more myopic at the revisit than the last follow-up visit in all eyes except the left eyes of the no exodrift group. The deviation angles of 11 patients who underwent continuous follow-up after the revisits did not significantly change over 1 year after full correction of the refractive error, with the exception of 1 who underwent re-operation.
Conclusions
When patients stabilize after intermittent exotropia surgery, the decrease in the corrected visual acuity triggers fusional convergence deterioration and, in turn, unstable strabismus. However, after full correction of the refractive error, the deviation angle stabilizes without further progression. It is important to explain this to patients/guardians at the end of initial follow-up.
6.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
7.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
8.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
9.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.
10.Analysis of the effect of fentanyl dosage used in patient-controlled analgesia for pain management after oral cancer surgery: a retrospective observational study
Kyung Nam PARK ; Seung-Hwa RYOO ; Myong-Hwan KARM ; Hyun Jeong KIM ; Kwang-Suk SEO
Journal of Dental Anesthesia and Pain Medicine 2025;25(1):43-53
Background:
Postoperative pain management is challenging in patients with oral cancer, especially those undergoing reconstructive surgery. Patient-controlled analgesia (PCA) is widely used, and fentanyl (FTN) concentration adjustments may improve pain control. This study aimed to evaluate the effects of FTN PCA concentration and reconstructive surgery on postoperative pain in patients with oral cancer.
Methods:
This retrospective observational study analyzed 140 patients with oral cancer who underwent surgery under general anesthesia. Patients were categorized based on FTN PCA dosage (FTN 700 mcg and ketorolac 150 mg vs. FTN 1400 mcg and ketorolac 150 mg). Pain was assessed using the visual analog scale (VAS) at multiple time points postoperatively (0, 12, 24, 36, 48, 60, and 72 h). PCA usage patterns, including demand count, delivery count, and delivery/demand ratios, were compared across subgroups. Missing data were imputed using linear interpolation.
Results:
PCA usage and pain control were evaluated between the FTN 700 mcg (N = 40) and 1400 mcg (N = 100) groups, stratified by reconstruction status. Demographic characteristics showed no significant difference.In the reconstructive surgery subgroup, patients in the FTN 1400 mcg group showed lower PCA refill counts (1.45 ± 0.69 vs. 1.61 ± 0.58) and fewer delivery counts (17.1 ± 21.3 vs. 25.1 ± 28.5) compared to those in the FTN 700 mcg group, achieving similar or superior pain control with fewer interventions. Similarly, patients without reconstructive surgery in the FTN 1400 mcg group demonstrated lower PCA refill counts, shorter PCA usage times, and fewer delivery counts. VAS scores decreased consistently over time across all groups but remained higher in the reconstruction groups. Logistic regression analysis revealed that patients with reconstructive surgery in the FTN 1400 mcg group were more likely to achieve a VAS score of ≤ 3.0 at 72 h postoperatively (P = 0.022). These findings indicate FTN 1400 mcg’s superiority in managing postoperative pain.
Conclusion
Comparing FTN PCA dosages, 1400 mcg demonstrated superior pain control to 700 mcg in patients undergoing oral cancer surgery, particularly those who underwent reconstructive surgery. This finding underscores the importance of optimizing FTN dosages to enhance postoperative pain management, reduce PCA-related demands, and achieve better patient outcomes.

Result Analysis
Print
Save
E-mail