2.Safety and efficacy of transcatheter closure of Fontan fenestration with atrial septal occluder.
Ying GUO ; Ting Liang LIU ; Xin Yi XU ; Wei GAO
Chinese Journal of Cardiology 2023;51(5):476-480
Objective: To assess the safety and efficacy of transcatheter fenestration closure following Fontan procedure with an atrial septal occluder. Methods: This is a retrospective study. The study sample consists of all consecutive patients who underwent closure of a fenestrated Fontan baffle at Shanghai Children's Medical Center Affiliated to Shanghai Jiaotong University School of Medicine between June 2002 and December 2019. The indications of Fontan fenestration closure included that normal ventricular function, targeted drugs for pulmonary hypertension and positive inotropic drugs were not required prior the procedure; and the Fontan circuit pressure was less than 16 mmHg (1 mmHg=0.133 kPa) and no more than a 2 mmHg increase during test occlusion of the fenestration. Electrocardiogram and echocardiography were reviewed at 24 hours, 1, 3, 6 months and annually thereafter post procedure. Follow-up information including clinical events and complications related to Fontan procedure was recorded. Results: A total of 11 patients, including 6 males and 5 females, aged (8.9±3.7) years old were included. The types of Fontan were extracardiac conduits (7 cases) and intra-atrial duct (4 cases). The interval between percutaneous fenestration closure and the Fontan procedure was (5.1±2.9) years. One patient reported recurrent headache after Fontan procedure. Successful fenestration occlusion with atrial septal occluder was achieved in all patients. Compared with prior closure, Fontan circuit pressure ((12.72±1.90) mmHg vs. (12.36±1.63) mmHg, P<0.05), and aortic oxygen saturation ((95.11±3.11)% vs. (86.35±7.26)%, P<0.01) were increased. There were no procedural complications. At a median follow-up of (3.8±1.2) years, there was no residual leak and evidence of stenosis within the Fontan circuit in all patient. No complication was observed during follow-up. One patient with preoperative headache did not have recurrent headache after closure. Conclusions: If the Fontan pressure is acceptable by test occlusion during the catheterization procedure, Fontan fenestration could be occluded with the atrial septum defect device. It is a safe and effective procedure, and could be used for occlusion of Fontan fenestration with varying sizes and morphologies.
Child
;
Male
;
Female
;
Humans
;
Child, Preschool
;
Septal Occluder Device
;
Retrospective Studies
;
Atrial Fibrillation
;
Cardiac Catheterization/methods*
;
China
;
Fontan Procedure/methods*
;
Treatment Outcome
5.Feasibility and safety of closing large left atrial appendage using the LAmbre device.
Yi Bo YU ; Guo Hua FU ; Wei Dong ZHUO ; Bin Hao WANG ; Hui Min CHU
Chinese Journal of Cardiology 2022;50(8):780-784
Objective: To evaluate the feasibility and safety of the LAmbre occluder for large-diameter left atrial appendage occlusion. Methods: This study was a retrospective cohort study. Patients with large orifice of the left atrial appendage (≥31 mm) and occlusion with the LAmbre device in the Arrhythmia Center of Ningbo First Hospital were included from June 2018 to March 2020. Baseline data were collected and major perioperative complications of left atrial appendage occlusion (including death, stroke, instrumental embolism, cardiac tamponade, and major bleeding events) were recorded. Patients were followed up 45 days, 6 months and 12 months after surgery. The shunt and device-related thrombosis were recorded by esophageal cardiac ultrasound or pulmonary vein CT, and the occurrence of postoperative thromboembolism, bleeding events, death and other serious adverse events were recorded. Results: The average age and left atrial appendage ostial dimension of 32 patients (37.5% women) included in this research were (70.4±8.4) years old and (34.4±2.9) mm. The LAmbre device was successfully implanted in 31(96.9%) patients. No major complications occurred during the perioperative period. During the 12-month follow-up, pericardial tamponade occurred in 1(3.2%) patient and was recovered after treatment. There was no occluder edge shunt>5 mm in patients followed up by esophageal echocardiography. No significant peri-device leak, device-related thrombus, thromboembolism or death event has occurred. Conclusion: The LAmbre occluder may be feasible and safe for large-diameter left atrial appendage occlusion.
Aged
;
Atrial Appendage/surgery*
;
Feasibility Studies
;
Female
;
Humans
;
Male
;
Middle Aged
;
Retrospective Studies
;
Septal Occluder Device/adverse effects*
;
Stroke/epidemiology*
;
Thromboembolism/etiology*
;
Thrombosis
;
Treatment Outcome
6.Three-dimensional volume rendering for dynamic characteristics of secundum atrial septal defect during various phases of the cardiac cycle and the impact on occluder selection.
Hui Jun SONG ; Shi Guo LI ; Qiong LIU ; Jing Lin JIN ; Kai YANG ; Jing ZHANG ; Zhong Ying XU ; Xiang Bin PAN ; Shi Hua ZHAO
Chinese Journal of Cardiology 2022;50(8):805-810
Objective: To investigate the dynamic change of the secundum atrial septal defect (ASD) throughout the cardiac cycle, and assess its impact on occluder selection. Methods: This study retrospectively analyzed 35 patients with ASD who received electrocardiogram-gated coronary CT angiography (CCTA) throughout the cardiac cycle as well as interventional closure therapy in Fuwai Hospital from December 2016 to December 2019. The raw data were reconstructed into 20 phasic images of RR intervals (RRI) ranging from 0 to 95% in an increment of 5% and transmitted to a workstation for postprocessing. For each phase image, CT virtual endoscopy reconstruction technique (CTVE) was used to provide views of ASD. Axial sequence assisted CT volumetric measurement (CTAS) was used to calculate the maximum dimensions in axial planes (Da) and in superior-inferior direction (Db). Using a formula for converting circumference to diameter, the equivalent circle dimensions were calculated (De, De=minor axis+2 (major axis-minor axis)/3). Taking the data of 75% RRI phase, the patients were divided into Da75%RRI≥Db75%RRI group and Da75%RRI
Adult
;
Cardiac-Gated Imaging Techniques
;
Computed Tomography Angiography
;
Coronary Angiography
;
Electrocardiography/methods*
;
Female
;
Heart Septal Defects, Atrial/surgery*
;
Humans
;
Imaging, Three-Dimensional
;
Male
;
Middle Aged
;
Retrospective Studies
;
Septal Occluder Device
7.Successful removal of displaced left atrial appendage occlusion device by double 14 F sheathes: a case report.
Wei Lun MENG ; Yi Xing ZHENG ; Zhong Yuan REN ; Hao Tian YANG ; Shuang LI ; Dong Dong ZHAO ; Wei CHEN ; Meng Yun ZHU ; Wei Jing LIU ; Yi ZHANG ; Ya Wei XU
Chinese Journal of Cardiology 2022;50(8):817-818
8.Efficacy and safety of a parylene-coated occluder for atrial septal defect: a prospective, multi-center, randomized controlled clinical trial.
Kai YANG ; Jian-Hua LYU ; Hai-Bo HU ; Wen-Hui WU ; Ge-Jun ZHANG ; Jing-Lin JIN ; Yu-Hao LIU ; Yuan FENG ; Li-Ming WANG ; Shi-Hua ZHAO ; Shi-Liang JIANG ; Wei LI ; Xiang-Bin PAN
Chinese Medical Journal 2021;134(22):2685-2691
BACKGROUND:
Nitinol-containing devices are widely used in clinical practice. However, there are concerns about nickel release after nitinol-containing device implantation. This study aimed to compare the efficacy and safety of a parylene-coated occluder vs. a traditional nitinol-containing device for atrial septal defect (ASD).
METHODS:
One-hundred-and-eight patients with ASD were prospectively enrolled and randomly assigned to either the trial group to receive a parylene-coated occluder (n = 54) or the control group to receive a traditional occluder (n = 54). The plugging success rate at 6 months after device implantation and the pre- and post-implantation serum nickel levels were compared between the two groups. A non-inferiority design was used to prove that the therapeutic effect of the parylene-coated device was non-inferior to that of the traditional device. The Cochran-Mantel-Haenszel chi-squared test with adjustment for central effects was used for the comparison between groups.
RESULTS:
At 6 months after implantation, successful ASD closure was achieved in 52 of 53 patients (98.11%) in both the trial and control groups (95% confidence interval (CI): [-4.90, 5.16]) based on per-protocol set analysis. The absolute value of the lower limit of the 95% CI was 4.90%, which was less than the specified non-inferiority margin of 8%. No deaths or severe complications occurred during 6 months of follow-up. The serum nickel levels were significantly increased at 2 weeks and reached the maximum value at 1 month after implantation in the control group (P < 0.05 vs. baseline). In the trial group, there was no significant difference in the serum nickel level before vs. after device implantation (P > 0.05).
CONCLUSIONS
The efficacy of a parylene-coated ASD occluder is non-inferior to that of a traditional uncoated ASD occluder. The parylene-coated occluder prevents nickel release after device implantation and may be an alternative for ASD, especially in patients with a nickel allergy.
Cardiac Catheterization
;
Heart Septal Defects, Atrial/surgery*
;
Humans
;
Polymers
;
Prospective Studies
;
Prosthesis Design
;
Septal Occluder Device/adverse effects*
;
Treatment Outcome
;
Xylenes
10.Association between the morphology of the implanted atrial septal defect occluding umbrella and postoperative headache.
Yao HUANG ; Jian Ming WANG ; Qi Guang WANG ; Duan Zhen ZHANG ; Xian Yang ZHU
Chinese Journal of Cardiology 2020;48(6):495-499
Objective: To explore whether the atrial septal defect(ASD) size, the type of occlusion umbrella selected, and the morphological changes after release of occlusion umbrella affect the headache symptoms of ASD patients after operation. Methods: A total of 567 ASD ptients, who underwent successful implantion with a single occlude from January 2014 to December 2017 in General Hospital of Northern Theater Command were enrolled. The patients were divided into symptomatic group and asymptomatic group according to the presence or absence of headache symptoms after occlusion. X-ray catheter calibration method was used to measure the diameter(d), thickness(L), maximum diameter of the left umbrella surface after release(D2) and the value of i (i = D2/L). Risk factors related to headache were analyzed by multivariate logistic regression analysis. linear regression analysis was used to detect the relationship between the type of occluder umbrella and ASD diameter in asymptomatic group. Results: A total of 567 patients with one occluder umbrella were included, and 148(26.1%) cases were male. The age was (34.4±19.4) years old. The follow-up time was (12.7±2.8) months. There were 51 cases in the symptomatic group and 516 cases in the asymptomatic group. In 29 patients who were treated by extending the course or increasing the dose of aspirin, the symptoms disappeared or improved. There was no significant difference in the maximum ASD diameter (TTE measured) and the size of occluder between the symptomatic group and asymptomatic group(both P>0.05). The value of d ((19.80±6.67)mm vs.(17.40±7.28) mm, P=0.041) D2 ((43.29±7.41)mm vs. (39.20±9.59)mm, P=0.013)and L((13.06±3.72)mm vs. (10.19±2.90) mm,P=0.025) of the symptomatic group were all higher than that of the asymptomatic group,while the i value was smaller((3.54±0.88)vs.(3.99±0.93),P=0.010). The results of multivariate logistic regression analysis showed that the value of L(OR=1.286,95%CI 1.176-1.406, P=0.002) and the value of i(OR=0.916,95%CI 0.867-0.968, P<0.001) were independent factors of headache symptoms in patients after ASD occlusion, while the value of d and the value of D2 were not independent factors (both P>0.05). Linear equations obtained from asymptomatic patients showed the size of occluder =1.121×the maximum ASD diameter of TTE measured +6.414. Conclusions: There is no correlation between the symptoms with the expanded diameter and the maximum diameter of left umbrella's surface after released. The Postoperative discomfort symptoms is significantly correlated to the thickness of the occluder and the value of i. It is suggested that headache could be induced by the oversized occlude, thus choosing the appropriate size of the occluder is essential to reduce the occurrence of postoperative headache symptoms. Increasing the size of occluder because of worrying about the abscission and removal of the occlude is unreasonable. The antiplatelet therapy should also be strengthened to reduce the occurrence of symptoms and improve the symptoms of the patients if the occluder's size is too large. This regression equation (The size of occluder =1.121 × the maximum ASD diameter of TTE measured +6.414) could be used as a reference for the suitable selection of ASD occluder.
Adolescent
;
Adult
;
Cardiac Catheterization
;
Echocardiography, Transesophageal
;
Headache
;
Heart Septal Defects, Atrial
;
Humans
;
Male
;
Middle Aged
;
Postoperative Period
;
Septal Occluder Device
;
Treatment Outcome
;
Young Adult

Result Analysis