1.Environmental disease monitoring by regional Environmental Health Centers in Korea: a narrative review
Myung-Sook PARK ; Hwan-Cheol KIM ; Woo Jin KIM ; Yun-Chul HONG ; Won-Jun CHOI ; Seock-Yeon HWANG ; Jiho LEE ; Young-Seoub HONG ; Yong-Dae KIM ; Seong-Chul HONG ; Joo Hyun SUNG ; Inchul JEONG ; Kwan LEE ; Won-Ju PARK ; Hyun-Joo BAE ; Seong-Yong YOON ; Cheolmin LEE ; Kyoung Sook JEONG ; Sanghyuk BAE ; Jinhee CHOI ; Ho-Hyun KIM
The Ewha Medical Journal 2025;48(1):e3-
This study explores the development, roles, and key initiatives of the Regional Environmental Health Centers in Korea, detailing their evolution through four distinct phases and their impact on environmental health policy and local governance. It chronicles the establishment and transformation of these centers from their inception in May 2007, through four developmental stages. Originally named Environmental Disease Research Centers, they were subsequently renamed Environmental Health Centers following legislative changes. The analysis includes the expansion in the number of centers, the transfer of responsibilities to local governments, and the launch of significant projects such as the Korean Children’s Environmental Health Study (Ko-CHENS ). During the initial phase (May 2007–February 2009), the 10 centers concentrated on research-driven activities, shifting from a media-centered to a receptor-centered approach. In the second phase, prompted by the enactment of the Environmental Health Act, six additional centers were established, broadening their scope to address national environmental health issues. The third phase introduced Ko-CHENS, a 20-year national cohort project designed to influence environmental health policy by integrating research findings into policy frameworks. The fourth phase marked a decentralization of authority, empowering local governments and redefining the centers' roles to focus on regional environmental health challenges. The Regional Environmental Health Centers have significantly evolved and now play a crucial role in addressing local environmental health issues and supporting local government policies. Their capacity to adapt and respond to region-specific challenges is essential for the effective implementation of environmental health policies, reflecting geographical, socioeconomic, and demographic differences.
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Potential of histone deacetylase 6 inhibitors in alleviating chemotherapy-induced peripheral neuropathy
Su Jung PARK ; Soung-Min LEE ; Seong Mook KANG ; Hyun-Mo YANG ; Su-Kil SEO ; Ju-Hee LEE
The Korean Journal of Pain 2025;38(2):152-162
Background:
Histone deacetylase 6 (HDAC6), belonging to class IIb of histone deacetylases, regulates theacetylation of the cytoplasmic protein α-tubulin. The overexpression of HDAC6 is linked to the development oftumors, and inhibiting HDAC6 is known to trigger apoptosis in multiple myeloma cells. In addition to its application in cancer treatment, bortezomib, a proteasome inhibitor, is widely used in managing multiple myeloma and has shown effectiveness in patients with both newly diagnosed and relapsed disease. However, the treatment regimen may be delayed or discontinued due to the risk of peripheral neuropathy, a significant non-hematologic side effect.
Methods:
Animal models of peripheral neuropathy induced by various anti-cancer drugs were established, confirming the potential of HDAC6 inhibitors as a treatment for this condition. Six- to eight-week-old male Sprague Dawley rats were utilized to create these models. Mechanical allodynia and electron microscopy served as indicators of peripheral neuropathy. The HDAC6 inhibitor CKD-011 was administered at doses of 5, 10, 20, and 40 mg/kg.
Results:
In an animal model of bortezomib-induced peripheral neuropathy, CKD-011, an HDAC6 inhibitor, effectively ameliorated peripheral neuropathy. Similarly, CKD-011 administration demonstrated recovery from peripheral neuropathy in models induced with oxaliplatin, paclitaxel, and cisplatin.
Conclusions
These findings suggest that HDAC6 inhibitors have the potential to mitigate peripheral neuropathy induced by chemotherapeutic agents.
4.Neurosteroids and neurological disorders
Gi Wan PARK ; Hayoung KIM ; Seong Hyun WON ; Nam Hyun KIM ; Sheu-Ran CHOI
The Korean Journal of Physiology and Pharmacology 2025;29(2):157-164
Neurosteroids play an important role as endogenous neuromodulators that are locally produced in the central nervous system and rapidly change the excitability of neurons and the activation of microglial cells and astrocytes. Here we review the mechanisms of synthesis, metabolism, and actions of neurosteroids in the central nervous system. Neurosteroids are able to play a variety of roles in the central nervous system under physiological conditions by binding to membrane ion channels and receptors such as gamma-aminobutyric acid type A receptors, Nmethyl-D-aspartate receptors, L- and T-type calcium channels, and sigma-1 receptors. In addition, numerous neurological disorders, including persistent neuropathic pain, multiple sclerosis, and seizures, have altered the levels of neurosteroids in the central nervous system. Thus, we review how local synthesis and metabolism of neurosteroids are modulated in the central nervous system and describe the role of neurosteroids under pathological conditions. Furthermore, we discuss whether neurosteroids may play a role as a new therapeutic for the treatment of neurological disorders.
5.Environmental disease monitoring by regional Environmental Health Centers in Korea: a narrative review
Myung-Sook PARK ; Hwan-Cheol KIM ; Woo Jin KIM ; Yun-Chul HONG ; Won-Jun CHOI ; Seock-Yeon HWANG ; Jiho LEE ; Young-Seoub HONG ; Yong-Dae KIM ; Seong-Chul HONG ; Joo Hyun SUNG ; Inchul JEONG ; Kwan LEE ; Won-Ju PARK ; Hyun-Joo BAE ; Seong-Yong YOON ; Cheolmin LEE ; Kyoung Sook JEONG ; Sanghyuk BAE ; Jinhee CHOI ; Ho-Hyun KIM
The Ewha Medical Journal 2025;48(1):e3-
This study explores the development, roles, and key initiatives of the Regional Environmental Health Centers in Korea, detailing their evolution through four distinct phases and their impact on environmental health policy and local governance. It chronicles the establishment and transformation of these centers from their inception in May 2007, through four developmental stages. Originally named Environmental Disease Research Centers, they were subsequently renamed Environmental Health Centers following legislative changes. The analysis includes the expansion in the number of centers, the transfer of responsibilities to local governments, and the launch of significant projects such as the Korean Children’s Environmental Health Study (Ko-CHENS ). During the initial phase (May 2007–February 2009), the 10 centers concentrated on research-driven activities, shifting from a media-centered to a receptor-centered approach. In the second phase, prompted by the enactment of the Environmental Health Act, six additional centers were established, broadening their scope to address national environmental health issues. The third phase introduced Ko-CHENS, a 20-year national cohort project designed to influence environmental health policy by integrating research findings into policy frameworks. The fourth phase marked a decentralization of authority, empowering local governments and redefining the centers' roles to focus on regional environmental health challenges. The Regional Environmental Health Centers have significantly evolved and now play a crucial role in addressing local environmental health issues and supporting local government policies. Their capacity to adapt and respond to region-specific challenges is essential for the effective implementation of environmental health policies, reflecting geographical, socioeconomic, and demographic differences.
6.Evaluation of the Popper Test as an Alternative to the Valsalva Maneuver for Assessing Eustachian Tube Function
Dae Hyun KIM ; Moon Su KWAK ; Ju Ha PARK ; Seong Hoon BAE
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(2):58-61
Background and Objectives:
The Valsalva test, although commonly utilized to assess the Eustachian tube function, is limited by drawbacks such as inconsistent pressure increases in the nasal cavity. Thus we introduced the “Popper test,” a tympanic membrane inflation test using the automatic middle ear inflation device known as middle ear inflation device (MEID), to explore its viability as an alternative to the Valsalva test.Subjects and Method We sampled 80 ears from patients between June 1, 2023, and August 1, 2023. Each patient underwent both the Valsalva and Popper tests using the MEID. Participants were divided into three categories: the “unable” group (patients who could not follow the Valsalva maneuver) and the “successful” and “unsuccessful” groups (patients whose attempts at the Valsalva or Popper tests either successed or failed). Success or failure was determined using an otoscope to assess the bulging of the tympanic membrane.
Results:
Of the 68 ears with normal middle ear pressure, 30.9% (21 ears) showed an inability to perform the Valsalva test, 45.6% (31 ears) successfully inflated the tympanic membrane via the Valsalva test, and 23.5% (16 ears) failed. Conversely, the Popper test resulted in an 88.2% (60 ears) success rate for inflating the tympanic membrane, with only 11.8% (8 ears) failing.
Conclusion
Variability observed in the Valsalva test outcomes may be attributed to individual differences and the instructor’s technique. MEID, as utilized in the Popper test, offers a promising alternative to the Valsalva test, potentially enhancing the reliability by minimizing individual variation. However, the diagnostic performance may be dependent on the properties of the MEID.
7.Imaging Findings of Complications of New Anticancer Drugs
Ji Sung JANG ; Hyo Jung PARK ; Chong Hyun SUH ; Sang Eun WON ; Eun Seong LEE ; Nari KIM ; Do-Wan LEE ; Kyung Won KIM
Korean Journal of Radiology 2025;26(2):156-168
The anticancer drugs have evolved significantly, spanning molecular targeted therapeutics (MTTs), immune checkpoint inhibitors (ICIs), chimeric antigen receptor T-cell (CAR-T) therapy, and antibody-drug conjugates (ADCs). Complications associated with these drugs vary widely based on their mechanisms of action. MTTs that target angiogenesis can often lead to complications related to ischemia or endothelial damage across various organs, whereas non-anti-angiogenic MTTs present unique complications derived from their specific pharmacological actions. ICIs are predominantly associated with immunerelated adverse events, such as pneumonitis, colitis, hepatitis, thyroid disorders, hypophysitis, and sarcoid-like reactions. CAR-T therapy causes unique and severe complications including cytokine release syndrome and immune effector cell-associated neurotoxicity syndrome. ADCs tend to cause complications associated with cytotoxic payloads. A comprehensive understanding of these drug-specific toxicities, particularly using medical imaging, is essential for providing optimal patient care. Based on this knowledge, radiologists can play a pivotal role in multidisciplinary teams. Therefore, radiologists must stay up-to-date on the imaging characteristics of these complications and the mechanisms underlying novel anticancer drugs.
8.Evaluation of the Popper Test as an Alternative to the Valsalva Maneuver for Assessing Eustachian Tube Function
Dae Hyun KIM ; Moon Su KWAK ; Ju Ha PARK ; Seong Hoon BAE
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(2):58-61
Background and Objectives:
The Valsalva test, although commonly utilized to assess the Eustachian tube function, is limited by drawbacks such as inconsistent pressure increases in the nasal cavity. Thus we introduced the “Popper test,” a tympanic membrane inflation test using the automatic middle ear inflation device known as middle ear inflation device (MEID), to explore its viability as an alternative to the Valsalva test.Subjects and Method We sampled 80 ears from patients between June 1, 2023, and August 1, 2023. Each patient underwent both the Valsalva and Popper tests using the MEID. Participants were divided into three categories: the “unable” group (patients who could not follow the Valsalva maneuver) and the “successful” and “unsuccessful” groups (patients whose attempts at the Valsalva or Popper tests either successed or failed). Success or failure was determined using an otoscope to assess the bulging of the tympanic membrane.
Results:
Of the 68 ears with normal middle ear pressure, 30.9% (21 ears) showed an inability to perform the Valsalva test, 45.6% (31 ears) successfully inflated the tympanic membrane via the Valsalva test, and 23.5% (16 ears) failed. Conversely, the Popper test resulted in an 88.2% (60 ears) success rate for inflating the tympanic membrane, with only 11.8% (8 ears) failing.
Conclusion
Variability observed in the Valsalva test outcomes may be attributed to individual differences and the instructor’s technique. MEID, as utilized in the Popper test, offers a promising alternative to the Valsalva test, potentially enhancing the reliability by minimizing individual variation. However, the diagnostic performance may be dependent on the properties of the MEID.
9.Imaging Findings of Complications of New Anticancer Drugs
Ji Sung JANG ; Hyo Jung PARK ; Chong Hyun SUH ; Sang Eun WON ; Eun Seong LEE ; Nari KIM ; Do-Wan LEE ; Kyung Won KIM
Korean Journal of Radiology 2025;26(2):156-168
The anticancer drugs have evolved significantly, spanning molecular targeted therapeutics (MTTs), immune checkpoint inhibitors (ICIs), chimeric antigen receptor T-cell (CAR-T) therapy, and antibody-drug conjugates (ADCs). Complications associated with these drugs vary widely based on their mechanisms of action. MTTs that target angiogenesis can often lead to complications related to ischemia or endothelial damage across various organs, whereas non-anti-angiogenic MTTs present unique complications derived from their specific pharmacological actions. ICIs are predominantly associated with immunerelated adverse events, such as pneumonitis, colitis, hepatitis, thyroid disorders, hypophysitis, and sarcoid-like reactions. CAR-T therapy causes unique and severe complications including cytokine release syndrome and immune effector cell-associated neurotoxicity syndrome. ADCs tend to cause complications associated with cytotoxic payloads. A comprehensive understanding of these drug-specific toxicities, particularly using medical imaging, is essential for providing optimal patient care. Based on this knowledge, radiologists can play a pivotal role in multidisciplinary teams. Therefore, radiologists must stay up-to-date on the imaging characteristics of these complications and the mechanisms underlying novel anticancer drugs.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail