1.Loss of Heterozygosity at Chromosome 16q Is a Negative Prognostic Factorin Korean Pediatric Patients with Favorable Histology Wilms Tumor:A Report of the Korean Pediatric Hematology Oncology Group (K-PHOG)
Jun Eun PARK ; O Kyu NOH ; Yonghee LEE ; Hyoung Soo CHOI ; Jung Woo HAN ; Seung Min HAHN ; Chuhl Joo LYU ; Ji Won LEE ; Keon Hee YOO ; Hong Hoe KOO ; Seon-Yong JEONG ; Ki Woong SUNG
Cancer Research and Treatment 2020;52(2):438-445
Purpose:
Loss of heterozygosity (LOH) at chromosomes 1p and 16q is a poor prognostic factor infavorable histology Wilms tumor (FHWT). This study investigated the prevalence of LOH at1p and 16q and evaluated its prognostic value in Korean children with FHWT.
Materials and Methods:
We analyzed 101 FHWT patients who were diagnosed between 1996 and 2016 in KoreanSociety of Pediatric Hematology Oncology Group hospitals. Using paraffin-embedded kidneytissue samples sent from each center, we reviewed LOH at 1p and 16q in each patient andassessed the prognostic value of LOH status for clinical parameters affecting event-freesurvival (EFS).
Results:
Of the 101 patients, 12 (11.9%) experienced recurrence; the 3-year EFS was 87.6%. LOHat 1p or 16q was detected in 19 patients (18.8%), with five having LOH at both 1q and 16q.The frequency of LOH at 1p was higher among younger patients (p=0.049), but there wasno difference in LOH prevalence according to tumor stage. In the multivariate analysis, LOHat 16q was a significant negative prognostic factor affecting EFS (3-year EFS, 73.7% vs.91.1%; hazard ratio, 3.95; p=0.037), whereas LOH at 1p was not (p=0.786).
Conclusion
LOH at 16q was a significant negative prognostic factor affecting outcome in Korean pediatricFHWT patients. Due to the small sample size of this study, large-scale multicenter trialsare warranted to investigate the prognostic value of LOH at 1p and 16q in Korean childrenwith FHWT.
2.Treatment Patterns and Changes in Quality of Life during First-Line Palliative Chemotherapy in Korean Patients with Advanced Gastric Cancer.
Jin Won KIM ; Jong Gwang KIM ; Byung Woog KANG ; Ik Joo CHUNG ; Young Seon HONG ; Tae You KIM ; Hong Suk SONG ; Kyung Hee LEE ; Dae Young ZANG ; Yoon Ho KO ; Eun Kee SONG ; Jin Ho BAEK ; Dong‐Hoe KOO ; So Yeon OH ; Hana CHO ; Keun Wook LEE
Cancer Research and Treatment 2019;51(1):223-239
PURPOSE: The purpose of this study was to evaluate chemotherapy patterns and changes in quality of life (QOL) during first-line palliative chemotherapy for Korean patients with unresectable or metastatic/recurrent gastric cancer (GC). MATERIALS AND METHODS: Thiswas a non-interventional, multi-center, prospective, observational study of 527 patients in Korea. QOL assessments were conducted using the European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaires (QLQ)-C30 and QLQ-STO22 every 3 months over a 12-month period during first-line palliative chemotherapy. The specific chemotherapy regimens were selected by individual clinicians. RESULTS: Most patients (93.2%) received combination chemotherapy (mainly fluoropyrimidine plus platinum) as their first-line palliative chemotherapy. The median progression-free survival and overall survival were 8.2 and 14.8 months, respectively. Overall, “a little” changes (differences of 5-10 points from baseline)were observed in some of the functioning or symptom scales; none of the QOL scales showed either “moderate” or “very much” change (i.e., ≥ 11 point difference from baseline). When examining the best change in each QOL domain from baseline, scales related to some aspects of functioning, global health status/QOL, and most symptoms revealed significant improvements (p < 0.05). Throughout the course of first-line palliative chemotherapy, most patients' QOL was maintained to a similar degree, regardless of their actual response to chemotherapy. CONCLUSION: This observational study provides important information on the chemotherapy patterns and QOL changes in Korean patientswith advanced GC. Overall, first-line palliative chemotherapy was found to maintain QOL, and most parameters showed an improvement compared with the baseline at some point during the course.
Disease-Free Survival
;
Drug Therapy*
;
Drug Therapy, Combination
;
Global Health
;
Humans
;
Korea
;
Observational Study
;
Prospective Studies
;
Quality of Life*
;
Stomach Neoplasms*
;
Weights and Measures
3.Performance Evaluation of the CRE2 Reagent from Siemens for Serum Creatinine Measurement.
Hyunjin KIM ; Jinsook LIM ; Sun Hoe KOO ; Jimyung KIM ; Seon Young KIM ; Gye Cheol KWON
Laboratory Medicine Online 2019;9(1):6-11
BACKGROUND: For creatinine measurement, the enzymatic method is known to be more accurate than the Jaffe method; however, the latter is still widely used. We evaluated the performance of the CRE2 reagent (Siemens Healthcare Diagnostics Inc., USA), which uses a modified Jaffe method. METHODS: Three quality control standards were used for precision evaluations of CRE2 on Dimension VISTA 500 instrument (Siemens). Moreover, the linearity and carryover characteristics were assessed. Sixty-eight creatinine results obtained using the CRE2 and ECREA (enzymatic) reagents (Siemens) were compared with those obtained using the L-CRE (enzymatic) reagent (Shinyang Diagnostics, Korea). The accuracy of CRE2, ECREA, and L-CRE was evaluated using a standard reference material. RESULTS: The CV of within-run (0.7–2.4%), between-run (0.4–1.7%), between-day precision (0.7–0.9%) for three standards, and total CV for medium (1.6%) and high levels (1.3%) satisfied the analytical goal. The linearity for CRE2 was excellent (R2=0.999). Comparisons of CRE2 and ECREA to L-CRE were well correlated (r=0.996 and 0.997, respectively). In comparison with L-CRE, 5 CRE2 results and 15 ECREA results exceeded minimum bias goal (5.1%) in samples with creatinine levels of >1 mg/dL. The carryover rate was −0.04%. In terms of accuracy, the percent bias values of CRE2, ECREA, and L-CRE were 7.4, −6.4, and −3.4, respectively, for low level; and 3.9, −1.5, and 0.7, respectively, for high level. CONCLUSIONS: For creatinine measurements, the CRE2 reagent showed good performance. It can be used in the diagnosis, treatment monitoring, and risk assessment of kidney diseases.
Bias (Epidemiology)
;
Creatinine*
;
Delivery of Health Care
;
Diagnosis
;
Indicators and Reagents
;
Kidney Diseases
;
Methods
;
Quality Control
;
Risk Assessment
4.Evaluation of the Automated Cross-Matching Instrument, ORTHO VISION, for Use in Blood Banks
Mosae KOO ; Jinsook LIM ; Seon Yung KIM ; Ji Myung KIM ; Sun Hoe KOO ; Gye Cheol KWON
Laboratory Medicine Online 2019;9(4):218-223
BACKGROUND: Automated systems are used widely for pre-transfusion tests in blood banks, in an attempt to reduce effort and human error. We evaluated the clinical performance of an automated blood bank system, ORTHO VISION (Ortho-Clinical Diagnostics, Switzerland), for blood cross-matching. METHODS: Saline cross-matching was performed for 93 tests using 56 samples. Coombs cross-matching was performed for 400 tests using 166 samples. Saline cross-matching was compared for the automated ORTHO VISION and manual tube methods. Coombs cross-matching was compared for the automated ORTHO VISION and manual column agglutination technique (CAT) methods. The evaluation of 32 antibody-positive samples using the automated ORTHO VISION and manual CAT methods was compared by performing 97 cross-matching tests. Additionally, the ORTHO VISION efficiency and carryover were evaluated. RESULTS: The concordance rate of the saline cross-matching results between the manual method and automated ORTHO VISION was 100%. The concordance rate of coombs cross-matching results between manual CAT and automated ORTHO VISION was 97.9%. The concordance rate of cross-matching for antibody positive samples between manual CAT and the automated ORTHO VISION was 97.9%. Coombs cross-matching was efficient using ORTHO VISION, whereas saline cross-matching was efficient using the tube manual method. CONCLUSIONS: ORTHO VISION showed reliable results for cross-matching and was more efficient than manual CAT for coombs cross-matching. Thus, ORTHO VISION can be used for pre-transfusion tests in blood banks.
Agglutination
;
Animals
;
Automation
;
Blood Banks
;
Cats
;
Humans
;
Methods
5.Comparison of Red Blood Cell, White Blood Cell and Differential Counts between UF-5000 System and Manual Method
Mo Sae KOO ; Jinsook LIM ; Seon Young KIM ; Sun Hoe KOO ; Gye Cheol KWON
Journal of Laboratory Medicine and Quality Assurance 2019;41(3):172-178
BACKGROUND: Analysis of body fluids provides important information for assessing various medical conditions. We aimed to validate the analytical and diagnostic performance of the Sysmex UF-5000 (Sysmex, Japan) system for the analysis of different body fluids. METHODS: Eighty body fluid samples were analyzed using the UF-5000 system in the body fluid mode and light microscopy. Body fluids included ascitic, pleural, and cerebrospinal fluid (CSF), as well as other fluid samples. RESULTS: A comparison between the UF-5000 system and manual counting demonstrated good correlations with regard to red (r=0.6555) and white blood cell (r=0.9666) counts. The UF-5000 system also demonstrated good performance for differential cell counting (r=0.9028). CSF particularly showed a good correlation. CONCLUSIONS: The use of the UF-5000 system for cell counting and differential analysis of body fluid samples might be an effective and automated alternative to chamber counting in laboratory routine analysis, thereby enhancing laboratory workflow and clinical effectiveness.
Automation
;
Body Fluids
;
Cell Count
;
Cerebrospinal Fluid
;
Erythrocytes
;
Leukocytes
;
Methods
;
Microscopy
;
Treatment Outcome
6.Arginase II inhibition prevents interleukin-8 production through regulation of p38 MAPK phosphorylation activated by loss of mitochondrial membrane potential in nLDL-stimulated hAoSMCs
Bon Hyeock KOO ; Bong Gu YI ; Myeong Seon JEONG ; Seung Hea KWON ; Kwang Lae HOE ; Young Guen KWON ; Moo Ho WON ; Young Myeong KIM ; Sungwoo RYOO
Experimental & Molecular Medicine 2018;50(2):e438-
Arginase inhibition exhibits beneficial effects in vascular endothelial and smooth muscle cells. In human aortic smooth muscle cells (hAoSMCs), native low-density lipoprotein (nLDL) induced the production of interleukin-8 (IL-8) that is involved in the pathogenesis of cardiovascular diseases. Therefore, we examined the effect of arginase inhibition on IL-8 production and the underlying mechanism. In hAoSMCs, reverse transcription–PCR, western blotting and immunocytochemistry with MitoTracker confirmed that arginase II was confined predominantly to mitochondria. The mitochondrial membrane potential (MMP) was assessed using tetramethylrhodamine ethyl ester. The MMP decreased upon nLDL stimulation but was restored upon arginase inhibition. MMP loss caused by nLDL was prevented by treatment with the intracellular Ca(2+) chelator BAPTA-AM. In mitochondrial Ca(2+) measurements using Rhod-2 AM, increased mitochondrial Ca(2+) levels by nLDL were inhibited upon preincubation with an arginase inhibitor. Among the polyamines, spermine, an arginase activity-dependent product, caused mitochondrial Ca(2+) movement. The nLDL-induced MMP change resulted in p38 mitogen-activated protein kinase (MAPK) phosphorylation and IL-8 production and was prevented by the arginase inhibitors BAPTA and ruthenium 360. In isolated AoSMCs from ApoE(−/−) mice fed a high-cholesterol diet, arginase activity, p38 MAPK phosphorylation, spermine and mitochondrial Ca(2+) levels and keratinocyte-derived chemokine (KC) production were increased compared with wild-type (WT) mice. However, in AoSMCs isolated from arginase II-null mice, increases in MMP and decreases in mitochondrial Ca(2+) levels were noted compared with WT and were associated with p38 MAPK activation and IL-8 production. These data suggest that arginase activity regulates the change in MMP through Ca(2+) uptake that is essential for p38 MAPK phosphorylation and IL-8 production.
7.Evaluation of the Automated Blood Bank Systems IH-500 and VISION Max for ABO-RhD Blood Typing and Unexpected Antibody Screening.
Yumi PARK ; Seon Young KIM ; Sun Hoe KOO ; Jinsook LIM ; Ji Myung KIM ; Young Ae LIM ; Gye Cheol KWON
Laboratory Medicine Online 2017;7(4):170-175
BACKGROUND: The use of automated systems for pre-transfusion tests is increasing in an attempt to reduce workload and the impact of human errors in blood banks. We evaluated the clinical performance of the automated blood bank systems IH-500 (Bio-Rad Laboratories, Switzerland) and VISION Max (Ortho-Clinical Diagnostics, USA) for ABO-RhD blood typing and unexpected antibody screening. METHODS: ABO-RhD blood typing was performed for 410 samples, and antibody screening was performed for 332 samples, including 15 antibody-positive samples. The results obtained from the two automated instruments were compared with those obtained using manual methods for ABO-RhD blood typing and a semiautomated method (DiaMed-ID system) for antibody screening. Additionally, both instruments were evaluated in terms of concordance rates, sensitivity, and carryover. RESULTS: The concordance rate of the ABO-RhD blood typing results between the manual methods and the two automated instruments was 100%. For antibody screening tests, the concordance rates between the semiautomated method (DiaMed-ID system) and the automated methods were 100% and 99.7% for the IH-500 and VISION Max instruments, respectively. The sole discrepant result was obtained for a sample identified as antibody-positive only on the VISION Max; the antibody was identified as anti-Le(a). The overall sensitivity of the two automated instruments was the same as or higher than that of the semiautomated method. Carryover was not observed in antibody screening. CONCLUSIONS: The IH-500 and VISION Max instruments showed reliable results for ABO-RhD blood typing and unexpected antibody screening, and can be used clinically, with confidence, for pre-transfusion tests in the blood bank.
Automation
;
Blood Banks*
;
Blood Grouping and Crossmatching*
;
Humans
;
Mass Screening*
;
Methods
8.Evaluation of Cardiac Function in Children with Solid Tumors, who Underwent Tandem High-Dose Chemotherapy and Autologous Stem Cell Transplantation
Yoo Seon KIM ; Jinyoung SONG ; Ki Woong SUNG ; Soo Hyun LEE ; Keon Hee YOO ; June HUH ; I Seok KANG ; Hong Hoe KOO
Clinical Pediatric Hematology-Oncology 2014;21(2):121-127
BACKGROUND: Even though the five year survival rate and prognosis of childhood solid tumors have been improved through the introduction of dose-escalation using tandem high-dose chemotherapy and autologous stem cell transplantation (HDCT/auto-SCT), changes in cardiac function have not yet been studied. We therefore evaluated cardiac function after tandem HDCT/auto-SCT.METHODS: This study retrospectively analyzed 56 pediatric patients who were diagnosed with solid tumors and who underwent tandem HDCT/auto-SCT at Samsung Medical Center. We investigated the cardiac function of these patients using echocardiography to evaluate the parameters of the left ventricular ejection fraction, e/e', and left ventricular Tei index.RESULTS: The mean left ventricular ejection fraction, e/e', and left ventricular Tei index at one year after the second HDCT/auto-SCT were 65.7%, 0.32, and 8.6, respectively. When compared those with before the first tandem HDCT/auto-SCT, there were no significant negative changes. We evaluated the changes in cardiac function in different subgroups, based on doxorubicin, radiotherapy involving heart, and the age of the patient at diagnosis. There were no significant changes of cardiac function after the treatment in any of the subgroups. Clinical heart failure did not develop in any of the patients.CONCLUSION: This study showed no significant negative changes in cardiac function at one year after tandem HDCT/auto-SCT. However, long-term follow-up studies of cardiac function in survivors and further studies of cardiac function are needed.
Child
;
Diagnosis
;
Doxorubicin
;
Drug Therapy
;
Echocardiography
;
Follow-Up Studies
;
Heart
;
Heart Failure
;
Humans
;
Prognosis
;
Radiotherapy
;
Retrospective Studies
;
Stem Cell Transplantation
;
Stroke Volume
;
Survival Rate
;
Survivors
9.Characterization of Class 1 Integrons in Metallo-beta-lactamase-producing Pseudomonas aeruginosa.
Ji Youn SUNG ; Sun Hoe KOO ; Kye Chul KWON ; Jong Woo PARK ; Chi Seon KO ; So Youn SHIN ; Jeong Hoon SONG
Korean Journal of Clinical Microbiology 2009;12(1):17-23
BACKGROUND: The genes of metallo-beta-lactamase (MBL), a powerful carbapenemase, are carried as a part of the mobile gene cassettes inserted into integrons playing an important role in rapid dissemination of antibiotic resistance genes among bacterial isolates. In this study, we investigated carbapenemase genes and class 1 integrons integrated into the gene cassettes in imipenem-non susceptible P. aeruginosa. METHODS: From July 2006 to March 2008, 81 consecutive, non-duplicate, imipenem-non susceptible P. aeruginosa were isolated at Chungnam National University Hospital in Chungcheong province of Korea. The modified Hodge and double disk synergy tests were conducted for the screening of carbapenemase and MBL production, respectively, and PCR and DNA sequencing were performed for the detection of carbapenemase genes and class 1 integron gene cassettes. We also employed the repetitive element sequence-based (Rep)-PCR method for an epidemiologic study. RESULTS: MBLs were detected in 13.6% (11/81) of imipenem-non susceptible P. aeruginosa. Ten isolates were found to carry blaIMP-1, whereas 1 isolate was found to carry a blaVIM-2. All of the IMP-1-producing strains harbored 4.0 kb class 1 integron containing chloramphenicol, aminoglycoside, and beta-lactam- resistant genes. However, blaIMP-1 was not detected at class 1 integron. A 2.5 kb class 1 integron harboring blaVIM-2 was detected in a VIIM-2- producing strain. One identical pattern was observed in ten IMP-1 producing strains. CONCLUSION: IMP-1 producing P. aeruginosa strains are currently distributed throughout Chungcheong province of Korea. In particular, all of the strains harbored class 1 integrons containing variant antibiotic resistance gene cassettes.
Bacterial Proteins
;
beta-Lactamases
;
Chloramphenicol
;
Drug Resistance, Microbial
;
Integrons
;
Korea
;
Mass Screening
;
Polymerase Chain Reaction
;
Pseudomonas
;
Pseudomonas aeruginosa
;
Sequence Analysis, DNA
;
Sprains and Strains
10.Dissemination of IMP-1 and OXA Type beta-Lactamase in Carbapenem-resistant Acinetobacter baumannii.
Ji Youn SUNG ; Kye Chul KWON ; Jong Woo PARK ; Yeon Suk KIM ; Ji Myung KIM ; Kyeong Seob SHIN ; Jong Wan KIM ; Chi Seon KO ; So Youn SHIN ; Jeong Hoon SONG ; Sun Hoe KOO
The Korean Journal of Laboratory Medicine 2008;28(1):16-23
BACKGROUND: Acinetobacter baumannii is an aerobic, gram-negative, glucose-nonfermenting bacterium, which has emerged as a serious opportunistic pathogen. In recent years, the increasing instance of carbapenem-resistant A. baumannii producing metallo-beta-lactamases (MBLs) or OXAtype beta-lactamases is causing a serious clinical problem. In this study, we investigated the prevalence of Ambler class A, B, and D beta-lactamases and their extended-spectrum derivatives in carbapenem-resistant A. baumannii isolates. METHODS: A total of 31 consecutive, non-duplicate, carbapenem-resistant A. baumannii were isolated from three university hospitals in the Chungcheong province of Korea. The modified Hodge and inhibitor-potentiated disk diffusion tests were conducted for the screening of carbapenemase and MBL production, respectively. PCR and DNA sequencing were performed for the detection of beta-lactamase genes. We also employed the enterobacterial repetitive intergenic consensus (ERIC)-PCR method for the epidemiologic study. RESULTS: Twenty-three of 31 isolates harbored bla(OXA-2) (51.6%), bla(OXA-23) (22.6%), bla(IMP-1) (48.4%),and bla(VIM-2) (3.2%). All of the OXA-2-producing strains also evidenced MBLs. The strains that harbored bla(OXA-23) were isolated only in hospital C, and only in a limited fashion. The ERIC-PCR pattern of the five OXA-23 strains indicated that the isolates were closely related in terms of clonality. The six strains producing IMP-1 isolated from hospital A were confirmed to be identical strains. CONCLUSIONS: A. baumannii strains harboring IMP-1 or OXA-type beta-lactamases are currently widely distributed throughout the Chungcheong province of Korea. The most notable finding in this study was that a bla(OXA-2)-producing A. baumannii harboring MBL, which has not been previously reported, can also lead to outbreaks.
Acinetobacter Infections/microbiology
;
Acinetobacter baumannii/drug effects/*enzymology/genetics
;
Anti-Bacterial Agents/*pharmacology
;
Carbapenems/*pharmacology
;
Disk Diffusion Antimicrobial Tests
;
Drug Resistance, Multiple, Bacterial
;
Humans
;
Polymerase Chain Reaction
;
beta-Lactamases/biosynthesis/genetics/*metabolism

Result Analysis
Print
Save
E-mail