1.The diagnostic performance of nuchal translucency alone as a screening test for Down syndrome: A systematic review and meta-analysis.
Ma. Sergia Fatima P. SUCALDITO ; John Jefferson V. BESA ; Lia M. PALILEO-VILLANUEVA
Acta Medica Philippina 2025;59(Early Access 2025):1-17
BACKGROUND
Down syndrome or trisomy 21, the most common chromosomal disorder, results from the presence of a third copy of chromosome 21 and manifests as mild to moderate intellectual disability, growth retardation, congenital heart defects, gastrointestinal abnormalities, and characteristic facial features. Several methods have been used to screen for Down syndrome in the prenatal period, such as ultrasound, biomarkers, cell-free DNA testing, and combinations of these tests. A positive result from one or more of these screening tests signals the need for confirmatory karyotyping to clinch the diagnosis. Ultrasound between 11 to 14 weeks of gestation can evaluate nuchal translucency (NT) to screen for Down syndrome. During the second trimester, a triple or quadruple test can also be performed alone or in addition to NT to quantify Down syndrome risk. In limited resource settings however, only the measurement of NT via ultrasound can be performed since biomarker tests are either unavailable or inaccessible. While the diagnostic performance of NT measurement alone has been investigated in several observational studies, there is no consensus on its performance as a sole test to screen for Down syndrome.
OBJECTIVETo determine the diagnostic performance of NT during prenatal first-trimester ultrasound as a screening test for Down syndrome.
METHODSWe performed a systematic search on the PubMed, ProQuest, and Cochrane Library databases for recent systematic reviews and meta-analyses that addressed the objective. The existing reviews found were then independently appraised by the two reviewers with the AMSTAR-2 checklist. To update the existing reviews, a systematic search was done in the same databases to identify additional primary diagnostic studies, which were appraised using the QUADAS-2 tool. Random-effects univariate meta-analysis and summary receiving operator curve (HSROC) analysis for the outcomes were performed using Review Manager version 5.4 and R version 4.2.2, respectively. Subgroup analysis was performed by stratifying the baseline risk of mothers for fetal anomaly as low- or high-risk. Highrisk mothers were defined as women with risk factors such as advanced age, positive serum screen, presence of other ultrasound anomalies, and history of previous fetus with anomaly.
RESULTSWe found 22 cohort studies (n=225,846) of women at low-risk for fetal anomaly. The pooled sensitivity was 67.8% (95% CI: 61.4%-73.6%, I2=70.4%) and specificity was 96.3% (95% CI: 95.5%-96.9%, I2=96.7%). For low-risk women, the overall certainty of evidence was low, due to different modes of verification and heterogeneity not completely explained by variability in baseline risk or cut-points. Seven studies (n=9,197) were on high-risk women. The pooled sensitivity was 62.2% (95% CI: 54.1%-69.7%, I2=38.8%) and specificity was 96.5% (95% CI: 93.6%-98.1%, I2=95.5%). For women at high-risk, the evidence was rated as moderate due to differential verification.
CONCLUSIONOur analysis showed that NT measured through first-trimester ultrasound is specific for Down syndrome but has low sensitivity. Despite this, it is a useful screening test for Down syndrome in low-resource settings where other strategies may not be available or accessible. Furthermore, interpretation of NT results must take into consideration its limited sensitivity as this may lead to missed cases.
Human ; Nuchal Translucency Measurement ; Down Syndrome ; Sensitivity And Specificity
2.In-vitro determination of minimum inhibitory concentration (MIC) and contact time of povidone-iodine against Staphylococcus aureus and Klebsiella aerogenes using micro suspension test, colorimetric resazurin microplate assay, and Dey Engley neutralizer assay.
Azita Racquel G. LACUNA ; Micaella C. DATO ; Loisse Mikaela M. LOTERIO ; Geraldine B. DAYRIT ; Sharon Yvette Angelina M. VILLANUEVA ; Maria Margarita M. LOTA
Acta Medica Philippina 2025;59(4):113-124
BACKGROUND AND OBJECTIVE
The human nasal passages host major human pathogens. Recent research suggests that the microbial communities inhabiting the epithelial surfaces of the nasal passages play a key factor in maintaining a healthy microenvironment by affecting both resistance to pathogens and immunological responses. Colonization of the nasal cavity by different pathogens such as Staphylococcus aureus and Klebsiella aerogenes, is associated with a higher postoperative infection morbidity. Povidone-iodine (PVP-I) as an antiseptic has been proven to display high antibacterial, antiviral, and antifungal properties even at low concentrations, and was shown to be effective in the control of infections to limit their impact and spread. It can be used as a topical antiseptic for skin decontamination and wound management, as a nasal spray, or as a gargle. There are different methods in testing the efficacy of potential antimicrobial suspensions. This study aimed to determine the concentration of PVP-I that is most effective in nasal decolonization using microsuspension test and colorimetric minimum inhibitory concentration (MIC) determination assays, resazurin microtiter assay (REMA), and Dey-Engley (D/E) neutralizer assay. The findings of this study will contribute to knowledge regarding the intended use of PVP-I in microbial control, particularly in bacterial infections.
METHODSSeveral dilutions (2.0%, 1.0%, 0.5%, 0.25%, 0.1% and 0.09%) of commercially bought 10% (10 mg per 100 ml) povidone-iodine were prepared and tested against a standardized inoculum (1x105) of Staphylococcus aureus and Klebsiella aerogenes at different contacttimes (5 seconds, 10 seconds, 30 seconds, 1 minute, and 5 minutes). Microdilution suspension test was performed to determine the log reduction per variable, while REMA and D/E neutralizer assay were used to determine the MIC. A value of greater than or equal to 5 log reduction was considered effective for microdilution suspension test. Estimates of agreement statistics were used to interpret the results of the assay in which the overall percent agreement (OPA), positive percent agreement (PPA), negative percent agreement (NPA), and Cohen’s kappa statistics were calculated.
RESULTSPovidone-iodine concentration of 0.25% exhibited ?5 log reduction against K. aerogenes at the minimum contact time of 5 seconds. On the other hand, a slightly higher PVP-I concentration was required to achieve ?5 log reduction for S. aureus at 0.5% concentration and a minimum contact time of 1 minute. There was an observed concordance of the results of REMA and D/E neutralizer as MIC colorimetric indicators, which yielded an overall test percent agreement of 90.30% (95% CI: 84.73–94.36), and a strong level of agreement (? = 0.8, pCONCLUSION
Low povidone-iodine concentrations (i.e., 0.5% against S. aureus and 0.25% against K. aerogenes) were observed to have bactericidal activity of at least 5 log reduction as rapid as the minimum contact time of 5 seconds. Furthermore, D/E and REMA, as colorimetric indicators, had comparable performance (OPA = 90.30%; ? = 0.8, p
Human
;
Bacteria
;
Povidone-iodine
;
Microbial Sensitivity Tests
;
Anti-infective Agents, Local
;
Enterobacter Aerogenes
;
Staphylococcus Aureus
3.Artemisia argyi extract subfraction exerts an antifungal effect against dermatophytes by disrupting mitochondrial morphology and function.
Le CHEN ; Yunyun ZHU ; Chaowei GUO ; Yujie GUO ; Lu ZHAO ; Yuhuan MIAO ; Hongzhi DU ; Dahui LIU
Chinese Journal of Natural Medicines (English Ed.) 2024;22(1):47-61
Artemisia argyi (A. argyi), a plant with a longstanding history as a raw material for traditional medicine and functional diets in Asia, has been used traditionally to bathe and soak feet for its disinfectant and itch-relieving properties. Despite its widespread use, scientific evidence validating the antifungal efficacy of A. argyi water extract (AAWE) against dermatophytes, particularly Trichophyton rubrum, Trichophyton mentagrophytes, and Microsporum gypseum, remains limited. This study aimed to substantiate the scientific basis of the folkloric use of A. argyi by evaluating the antifungal effects and the underlying molecular mechanisms of its active subfraction against dermatophytes. The results indicated that AAWE exhibited excellent antifungal effects against the three aforementioned dermatophyte species. The subfraction AAWE6, isolated using D101 macroporous resin, emerged as the most potent subfraction. The minimum inhibitory concentrations (MICs) of AAWE6 against T. rubrum, M. gypseum, and T. mentagrophytes were 312.5, 312.5, and 625 μg·mL-1, respectively. Transmission electron microscopy (TEM) results and assays of enzymes linked to cell wall integrity and cell membrane function indicated that AAWE6 could penetrate the external protective barrier of T. rubrum, creating breaches ("small holes"), and disrupt the internal mitochondrial structure ("granary"). Furthermore, transcriptome data, quantitative real-time PCR (RT-qPCR), and biochemical assays corroborated the severe disruption of mitochondrial function, evidenced by inhibited tricarboxylic acid (TCA) cycle and energy metabolism. Additionally, chemical characterization and molecular docking analyses identified flavonoids, primarily eupatilin (131.16 ± 4.52 mg·g-1) and jaceosidin (4.17 ± 0.18 mg·g-1), as the active components of AAWE6. In conclusion, the subfraction AAWE6 from A. argyi exerts antifungal effects against dermatophytes by disrupting mitochondrial morphology and function. This research validates the traditional use of A. argyi and provides scientific support for its anti-dermatophytic applications, as recognized in the Chinese patent (No. ZL202111161301.9).
Antifungal Agents/chemistry*
;
Arthrodermataceae
;
Artemisia/chemistry*
;
Molecular Docking Simulation
;
Mitochondria
;
Microbial Sensitivity Tests
4.Synergistic effect of β-thujaplicin and tigecycline against tet(X4)-positive Escherichia coli in vitro.
Muchen ZHANG ; Huangwei SONG ; Zhiyu ZOU ; Siyuan YANG ; Hui LI ; Chongshan DAI ; Dejun LIU ; Bing SHAO ; Congming WU ; Jianzhong SHEN ; Yang WANG
Chinese Journal of Biotechnology 2023;39(4):1621-1632
The widespread of tigecycline resistance gene tet(X4) has a serious impact on the clinical efficacy of tigecycline. The development of effective antibiotic adjuvants to combat the looming tigecycline resistance is needed. The synergistic activity between the natural compound β-thujaplicin and tigecycline in vitro was determined by the checkerboard broth microdilution assay and time-dependent killing curve. The mechanism underlining the synergistic effect between β-thujaplicin and tigecycline against tet(X4)-positive Escherichia coli was investigated by determining cell membrane permeability, bacterial intracellular reactive oxygen species (ROS) content, iron content, and tigecycline content. β-thujaplicin exhibited potentiation effect on tigecycline against tet(X4)-positive E. coli in vitro, and presented no significant hemolysis and cytotoxicity within the range of antibacterial concentrations. Mechanistic studies demonstrated that β-thujaplicin significantly increased the permeability of bacterial cell membranes, chelated bacterial intracellular iron, disrupted the iron homeostasis and significantly increased intracellular ROS level. The synergistic effect of β-thujaplicin and tigecycline was identified to be related to interfere with bacterial iron metabolism and facilitate bacterial cell membrane permeability. Our studies provided theoretical and practical data for the application of combined β-thujaplicin with tigecycline in the treatment of tet(X4)-positive E. coli infection.
Humans
;
Tigecycline/pharmacology*
;
Escherichia coli/metabolism*
;
Reactive Oxygen Species/therapeutic use*
;
Plasmids
;
Anti-Bacterial Agents/metabolism*
;
Escherichia coli Infections/microbiology*
;
Bacteria/genetics*
;
Microbial Sensitivity Tests
5.Optimal Parameters for Virtual Mono-Energetic Imaging of Liver Solid Lesions.
Acta Academiae Medicinae Sinicae 2023;45(2):280-284
Objective To explore the optimal parameters for virtual mono-energetic imaging of liver solid lesions. Methods A retrospective analysis was performed on 60 patients undergoing contrast-enhanced spectral CT of the abdomen.The iodine concentration values of hepatic arterial phase images and the CT values of different mono-energetic images were measured.The correlation coefficient and coefficient of variation were calculated. Results The average correlation coefficients between iodine concentrations and CT values of hepatic solid lesion images at 40,45,50,55,60,65,and 70 keV were 0.996,0.995,0.993,0.989,0.978,0.970,and 0.961,respectively.The correlation coefficients at 40(P=0.007),45(P=0.022),50 keV (P=0.035)were higher than that at 55 keV,and the correlation coefficients at 40 keV(P=0.134) and 45 keV(P=0.368) had no significant differences from that at 50 keV.The coefficients of variation of the CT values at 40,45,and 50 keV were 0.146,0.154,and 0.163,respectively. Conclusion The energy of 40 keV is optimal for virtual mono-energetic imaging of liver solid lesions in the late arterial phase,which is helpful for the diagnosis of liver diseases.
Humans
;
Tomography, X-Ray Computed
;
Retrospective Studies
;
Abdomen
;
Iodine
;
Liver/diagnostic imaging*
;
Signal-To-Noise Ratio
;
Radiographic Image Interpretation, Computer-Assisted/methods*
6.Quality of Images Reconstructed by Deep Learning Reconstruction Algorithm for Head and Neck CT Angiography at 100 kVp.
Xiao-Ping LU ; Yun WANG ; Yu CHEN ; Yan-Ling WANG ; Min XU ; Zheng-Yu JIN
Acta Academiae Medicinae Sinicae 2023;45(3):416-421
Objective To evaluate the impact of deep learning reconstruction algorithm on the image quality of head and neck CT angiography (CTA) at 100 kVp. Methods CT scanning was performed at 100 kVp for the 37 patients who underwent head and neck CTA in PUMC Hospital from March to April in 2021.Four sets of images were reconstructed by three-dimensional adaptive iterative dose reduction (AIDR 3D) and advanced intelligent Clear-IQ engine (AiCE) (low,medium,and high intensity algorithms),respectively.The average CT value,standard deviation (SD),signal-to-noise ratio (SNR),and contrast-to-noise ratio (CNR) of the region of interest in the transverse section image were calculated.Furthermore,the four sets of sagittal maximum intensity projection images of the anterior cerebral artery were scored (1 point:poor,5 points:excellent). Results The SNR and CNR showed differences in the images reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D (all P<0.01).The quality scores of the image reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D were 4.78±0.41,4.92±0.27,4.97±0.16,and 3.92±0.27,respectively,which showed statistically significant differences (all P<0.001). Conclusion AiCE outperformed AIDR 3D in reconstructing the images of head and neck CTA at 100 kVp,being capable of improving image quality and applicable in clinical examinations.
Humans
;
Computed Tomography Angiography/methods*
;
Radiation Dosage
;
Deep Learning
;
Radiographic Image Interpretation, Computer-Assisted/methods*
;
Signal-To-Noise Ratio
;
Algorithms
7.Value of High-Frequency Ultrasound in the Diagnosis of Pronator Teres Syndrome.
Min HU ; Shi-Yu CHEN ; Xiao-Long YANG ; Tian-Fang LIN ; Jie-Feng WANG ; Zheng-Hua ZANG
Acta Academiae Medicinae Sinicae 2023;45(3):436-439
Objective To investigate the clinical value of high-frequency ultrasound in the diagnosis of pronator teres syndrome (PTS). Methods The high-frequency ultrasound was employed to examine and measure the median nerve of the pronator teres muscle in 30 patients with PTS and 30 healthy volunteers (control group).The long-axis diameter (LA),short-axis diameter (SA) and cross-sectional area (CSA) of the median nerve were measured.The receiver operating characteristic curve of the median nerve ultrasonic measurement results was established,and the area under the curve (AUC) was calculated.The diagnostic efficiency of each index for PTS was compared with the surgical results as a reference. Results The PTS group showed larger LA[(5.02±0.50) mm vs.(3.89±0.41) mm;t=4.38,P=0.013],SA[(2.55±0.46) mm vs.(1.70±0.41) mm;t=5.19,P=0.009],and CSA[(11.13±3.72) mm2 vs.(6.88±2.68) mm2;t=8.42,P=0.008] of the median nerve than the control group.The AUC of CSA,SA,and LA was 94.3% (95%CI=0.912-0.972,Z=3.586,P=0.001),77.7% (95%CI=0.734-0.815,Z=2.855, P=0.006),and 78.8% (95%CI=0.752-0.821,Z=3.091,P=0.004),respectively.With 8.63 mm2 as the cutoff value,the sensitivity and specificity of CSA in diagnosing PTS were 93.3% and 90.0%,respectively. Conclusion High-frequency ultrasound is a practical method for diagnosing PTS,and the CSA of median nerve has a high diagnostic value.
Humans
;
Forearm/innervation*
;
Muscle, Skeletal/innervation*
;
Median Nerve/diagnostic imaging*
;
Ultrasonography/methods*
;
Sensitivity and Specificity
8.Primary study on recognition of vascular stiffness based on wavelet scattering neural network.
Shuqi REN ; Zengsheng CHEN ; Xiaoyan DENG ; Yubo FAN ; Anqiang SUN
Journal of Biomedical Engineering 2023;40(2):244-248
Cardiovascular disease is the leading cause of death worldwide, accounting for 48.0% of all deaths in Europe and 34.3% in the United States. Studies have shown that arterial stiffness takes precedence over vascular structural changes and is therefore considered to be an independent predictor of many cardiovascular diseases. At the same time, the characteristics of Korotkoff signal is related to vascular compliance. The purpose of this study is to explore the feasibility of detecting vascular stiffness based on the characteristics of Korotkoff signal. First, the Korotkoff signals of normal and stiff vessels were collected and preprocessed. Then the scattering features of Korotkoff signal were extracted by wavelet scattering network. Next, the long short-term memory (LSTM) network was established as a classification model to classify the normal and stiff vessels according to the scattering features. Finally, the performance of the classification model was evaluated by some parameters, such as accuracy, sensitivity, and specificity. In this study, 97 cases of Korotkoff signal were collected, including 47 cases from normal vessels and 50 cases from stiff vessels, which were divided into training set and test set according to the ratio of 8 : 2. The accuracy, sensitivity and specificity of the final classification model was 86.4%, 92.3% and 77.8%, respectively. At present, non-invasive screening method for vascular stiffness is very limited. The results of this study show that the characteristics of Korotkoff signal are affected by vascular compliance, and it is feasible to use the characteristics of Korotkoff signal to detect vascular stiffness. This study might be providing a new idea for non-invasive detection of vascular stiffness.
Humans
;
Vascular Stiffness
;
Neural Networks, Computer
;
Cardiovascular Diseases/diagnosis*
;
Sensitivity and Specificity
9.Research on phase modulation to enhance the feature of high-frequency steady-state asymmetric visual evoked potentials.
Wei ZHAO ; Lichao XU ; Xiaolin XIAO ; Weibo YI ; Yuanfang CHEN ; Kun WANG ; Minpeng XU ; Dong MING
Journal of Biomedical Engineering 2023;40(3):409-417
High-frequency steady-state asymmetric visual evoked potential (SSaVEP) provides a new paradigm for designing comfortable and practical brain-computer interface (BCI) systems. However, due to the weak amplitude and strong noise of high-frequency signals, it is of great significance to study how to enhance their signal features. In this study, a 30 Hz high-frequency visual stimulus was used, and the peripheral visual field was equally divided into eight annular sectors. Eight kinds of annular sector pairs were selected based on the mapping relationship of visual space onto the primary visual cortex (V1), and three phases (in-phase[0º, 0º], anti-phase [0º, 180º], and anti-phase [180º, 0º]) were designed for each annular sector pair to explore response intensity and signal-to-noise ratio under phase modulation. A total of 8 healthy subjects were recruited in the experiment. The results showed that three annular sector pairs exhibited significant differences in SSaVEP features under phase modulation at 30 Hz high-frequency stimulation. And the spatial feature analysis showed that the two types of features of the annular sector pair in the lower visual field were significantly higher than those in the upper visual field. This study further used the filter bank and ensemble task-related component analysis to calculate the classification accuracy of annular sector pairs under three-phase modulations, and the average accuracy was up to 91.5%, which proved that the phase-modulated SSaVEP features could be used to encode high- frequency SSaVEP. In summary, the results of this study provide new ideas for enhancing the features of high-frequency SSaVEP signals and expanding the instruction set of the traditional steady state visual evoked potential paradigm.
Humans
;
Evoked Potentials, Visual
;
Brain-Computer Interfaces
;
Healthy Volunteers
;
Signal-To-Noise Ratio
10.Accuracy of Mean Value of Central Venous Pressure from Monitor Digital Display: Influence of Amplitude of Central Venous Pressure during Respiration.
Meng-Ru XU ; Wang-Lin LIU ; Huai-Wu HE ; Xiao-Li LAI ; Mei-Ling ZHAO ; Da-Wei LIU ; Yun LONG
Chinese Medical Sciences Journal 2023;38(2):117-124
Background A simple measurement of central venous pressure (CVP)-mean by the digital monitor display has become increasingly popular. However, the agreement between CVP-mean and CVP-end (a standard method of CVP measurement by analyzing the waveform at end-expiration) is not well determined. This study was designed to identify the relationship between CVP-mean and CVP-end in critically ill patients and to introduce a new parameter of CVP amplitude (ΔCVP= CVPmax - CVPmin) during the respiratory period to identify the agreement/disagreement between CVP-mean and CVP-end.Methods In total, 291 patients were included in the study. CVP-mean and CVP-end were obtained simultaneously from each patient. CVP measurement difference (|CVP-mean - CVP-end|) was defined as the difference between CVP-mean and CVP-end. The ΔCVP was calculated as the difference between the peak (CVPmax) and the nadir value (CVPmin) during the respiratory cycle, which was automatically recorded on the monitor screen. Subjects with |CVP-mean - CVP-end|≥ 2 mmHg were divided into the inconsistent group, while subjects with |CVP-mean - CVP-end| < 2 mmHg were divided into the consistent group.Results ΔCVP was significantly higher in the inconsistent group [7.17(2.77) vs.5.24(2.18), P<0.001] than that in the consistent group. There was a significantly positive relationship between ΔCVP and |CVP-mean - CVP-end| (r=0.283, P <0.0001). Bland-Altman plot showed the bias was -0.61 mmHg with a wide 95% limit of agreement (-3.34, 2.10) of CVP-end and CVP-mean. The area under the receiver operating characteristic curves (AUC) of ΔCVP for predicting |CVP-mean - CVP-end| ≥ 2 mmHg was 0.709. With a high diagnostic specificity, using ΔCVP<3 to detect |CVP-mean - CVP-end| lower than 2mmHg (consistent measurement) resulted in a sensitivity of 22.37% and a specificity of 93.06%. Using ΔCVP>8 to detect |CVP-mean - CVP-end| >8 mmHg (inconsistent measurement) resulted in a sensitivity of 31.94% and a specificity of 91.32%.Conclusions CVP-end and CVP-mean have statistical discrepancies in specific clinical scenarios. ΔCVP during the respiratory period is related to the variation of the two CVP methods. A high ΔCVP indicates a poor agreement between these two methods, whereas a low ΔCVP indicates a good agreement between these two methods.
Humans
;
Central Venous Pressure
;
Respiration
;
ROC Curve


Result Analysis
Print