1.Annual review of clinical research on lung transplantation of China in 2024
Xiaohan JIN ; Yixin SUN ; Jier MA ; Zengwei YU ; Yaling LIU ; Senlin HOU ; Xiangyun ZHENG ; Haoji YAN ; Dong TIAN
Organ Transplantation 2025;16(3):379-385
		                        		
		                        			
		                        			Lung transplantation is currently the only recognized effective treatment for end-stage lung disease and has improved the quality of life for patients. However, lung transplantation still faces many challenges, including rejection, infection, post-transplant acute kidney injury, post-transplant diabetes mellitus, ischemia-reperfusion injury and donor shortage, etc. Chinese lung transplantation scholars made a series of important progress in the field of clinical research in 2024, focusing on the study and solution of the above problems, and providing new ideas for lung transplantation surgery. This article systematically reviews the clinical research and technological innovation in the field of lung transplantation in 2024, summarizes the achievements of clinical research in the field of lung transplantation in China in 2024, and aims to providing new directions and strategies for future research.
		                        		
		                        		
		                        		
		                        	
2.Annual review of basic research on lung transplantation of China in 2024
Jier MA ; Junmin ZHU ; Lan ZHANG ; Xiaohan JIN ; Xiangyun ZHENG ; Senlin HOU ; Zengwei YU ; Yaling LIU ; Haoji YAN ; Dong TIAN
Organ Transplantation 2025;16(3):386-393
		                        		
		                        			
		                        			Lung transplantation is the optimal treatment for end-stage lung diseases and can significantly improve prognosis of the patients. However, postoperative complications such as infection, rejection, ischemia-reperfusion injury, and other challenges (like shortage of donor lungs) , limit the practical application of lung transplantation in clinical practice. Chinese research teams have been making continuous efforts and have achieved breakthroughs in basic research on lung transplantation by integrating emerging technologies and cutting-edge achievements from interdisciplinary fields, which has strongly propelled the development of this field. This article will comprehensively review the academic progress made by Chinese research teams in the field of lung transplantation in 2024, with a focus on the achievements of Chinese teams in basic research on lung transplantation. It aims to provide innovative ideas and strategies for key issues in the basic field of lung transplantation and to help China's lung transplantation cause reach a higher level.
		                        		
		                        		
		                        		
		                        	
3.A controlled study on the impacts of different scanning protocols on image quality and radiation dose in chest CT
Chulin XU ; Wentao MA ; Yongxian ZHANG ; Yunfu LIU ; Tianliang KANG ; Senlin GUO ; Yantao NIU
Chinese Journal of Radiological Medicine and Protection 2024;44(9):789-796
		                        		
		                        			
		                        			Objective:To explore and compare the impacts of different scanning protocols on image quality and radiation dose in chest computed tomography (CT) scans.Methods:A retrospective analysis was conducted for the data of 65 randomly selected patients who underwent chest CT scans using a tube voltage of 120 kV, the automatic modulation technique for tube current, and z-axis radiation dose modulation at the Emergency Department of our hospital from June to July 2023. The enrolled cases were divided into two groups: the high-resolution group ( n = 34) and the conventional group ( n = 31), with the settings for scanning protocols identical to those for phantom scans. For patients in both groups, thin-layer images of the cross-sections in the lung and mediastinal windows were reconstructed using thickness/intervals of 1 mm/1 mm and 2 mm/1 mm, respectively. Meanwhile, high-resolution and conventional CT scans were conducted using a Catphan500 phantom under a tube voltage of 120 kV and a tube current of 150 mAs. Of both scanning protocols, the high-resolution CT scan utilized the lung nodule-orientated scanning mode, pitch of 1.5, and a detector combination providing a collimation of 16 × 0.75 mm. In contrast, the conventional CT scan was performed using the body-orientated scanning mode, pitch of 0.813, and a detector combination providing a collimation of 16 × 1.5 mm. Then, the high-contrast resolutions of the phantom images obtained using the two scanning protocols were objectively evaluated. Both coronal chest images in the lung window and cross-sectional images in the mediastinal window were reconstructed with a thickness/interval of 5 mm/5 mm for both groups. Then, the obtained images were imported into the Radimetrics system to compare the body size-specific dose estimation (SSDE), doses to sensitive organs on the body surface, and scanning time of both groups. For the cross-sectional images in the mediastinal window, the contrast-noise-ratio (CNR), signal-to-noise ratio (SNR), and figure-of-merit (FOM) were measured and calculated at the fixed anatomical parts. For the cross-sectional images in the lung window, their quality was subjectively evaluated by two senior diagnostic radiologists. Results:The result of phantom scans indicated that high-resolution CT scans yielded images with an approximately 5% increase in the spatial resolution in the xy-plane and a nearly 20% increase in the spatial resolution along the z-axis compared to conventional CT scans. The result of clinical data demonstrated that the conventional group exhibited significantly higher doses to the thyroid and the female breast ( t = 2.8, 2.3, P < 0.05), along with notably elevated SNR, CNR, and FOM values of the right trapezius, compared to the high-resolution group ( t = 4.1, 5.8, z=4.4, P < 0.001). However, the high-resolution group manifested significantly higher SNR, CNR, and FOM values of the thoracic aorta compared to the conventional group ( t = 3.4, 4.4, z=3.4, P < 0.001). In addition, the cross-sectional and coronal images in the lung window of the clinical cases in the high-resolution group exhibited more stable quality, with subjective scores exceeding 4 and the average scores of both groups not statistically significantly different. Conclusions:For chest CT examination, high-resolution CT scans are more suitable for observations focusing on the details of the lungs and mediastinum, while conventional CT is more suitable for those centering on soft tissues on the body surface.
		                        		
		                        		
		                        		
		                        	
4.Study on the effect of virtual grid on chest X-ray image quality
Tianliang KANG ; Yunfu LIU ; Yongxian ZHANG ; Senlin GUO ; Wentao MA ; Yantao NIU
Chinese Journal of Radiology 2023;57(5):547-552
		                        		
		                        			
		                        			Objective:To explore the image quality and its evaluation method using virtual grid under different tube voltages in the clinical chest X-ray exam.Methods:According to the conditions of chest X-ray photography commonly used in clinical practice, the corresponding thickness of plexiglass (20 cm, including CDRAD phantom) was determined as the experimental object. With a fixed tube loading of 4 mAs and the tube voltage from 60 to 125 kV, the experimental object was imaged in three ways: physical grid, none grid and virtual grid. The common physical parameters (CNR, σ, C, SNR), texture analysis (Angular second moment, texture Contrast, Correlation, Inverse difference moment, Entropy) and CDRAD phantom score (IQF inv) were evaluated. Two-way ANOVA test was used for each group of common physical parameters, and further pairwise comparisons were made. At the same time, applying virtual grids on the obtained images with chest anthropomorphic model and texture indexing the images with and without virtual grids, then rank sum test of paired sample can be conducted. Results:There were differences in image quality among the three groups of grid mode( P<0.05), and the physical grid delivered the best image quality. The tube voltage had an impact on all image quality evaluation indexes ( P<0.05). The tube voltage was positively correlated with CNR, SNR, angular second moment, inverse difference moment and IQF inv ( P<0.05), and negatively correlated with σ, C, texture contrast and entropy ( P<0.05). There was no significant correlation between the tube voltage and Correlation ( P>0.05). The chest anthropomorphic model images were used to evaluate the virtual grids, and the texture indexes (Angle second moment, Contrast, Correlation, Inverse difference moment, Entropy) were statistically significant (P<0.05). Conclusions:The virtual grid can improve the image quality of chest X-ray photography, and the image texture analysis method can be a useful supplement to the image quality evaluation parameters.
		                        		
		                        		
		                        		
		                        	
5.Practical research on goal-oriented hierarchical responsibility system in emergency standardized training and teaching
Hong HU ; Senlin MA ; Yueying HUANG ; Mingquan CHEN
Chinese Journal of Medical Education Research 2022;21(10):1376-1379
		                        		
		                        			
		                        			Objective:To explore the practical effect of goal-oriented hierarchical responsibility system in the teaching of emergency standardized training.Methods:A total of 43 residents who rotated in the Emergency Department of Huashan Hospital Affiliated to Fudan University from March 2019 to August 2019 were selected as the control group, and traditional teaching was implemented. Another 41 residents who rotated from September 2019 to March 2020 were selected as the research group, and the goal-oriented hierarchical responsibility system of teaching was implemented. They were all taught for 3 months, and the scores of theoretical and clinical skills, clinical comprehensive ability and teaching recognition before and after teaching were compared between the two groups. SPSS 24.0 was used for t-test and Chi-square test. Results:After teaching, the scores of theoretical knowledge questions, question and answer questions and case analysis in the two groups were higher than those before teaching ( P<0.05), and the scores of the research group were higher than those in the control group ( P<0.05). After teaching, the scores of 8 items in the study group on understanding of skill indications, anatomy and operation, preparation before operation, aseptic operation, operation ability, post-operation treatment, communication ability, humanistic care and overall performance were higher than those in the control group ( P<0.05). The recognition rates of teaching management, teaching methods, teaching content and teaching effect in the research group were higher than those in the control group ( P<0.05). Conclusion:The application of goal-oriented hierarchical responsibility system in the teaching of standardized training of emergency residents is helpful to improve their theoretical and clinical skill examination results and clinical ability, with high degree of teaching recognition.
		                        		
		                        		
		                        		
		                        	
6.Experimental study of stomach tumor localization based on magnetic tracer technique
Qian FAN ; Yi LIN ; Jia MA ; Senlin ZHU ; Yuwei WU ; Xingyi MOU ; Bo DENG ; Shiran KANG ; Min FAN ; Feng MA ; Yi LYU ; Xiaopeng YAN
Chinese Journal of General Surgery 2020;35(1):49-51
		                        		
		                        			
		                        			Objective To verify the feasibility and safety of stomach tumor marker localization based on magnetic tracer technique in dogs.Methods Six male Beagle dogs were examined by gastroscopy.Then tracer magnets were sent to the "tumor" locations assumed in advance and fixed near the "tumors" by endoscopic soft tissue clamp.Laparoscopic gastric tumor localization was performed under general anesthesia 24 hours later.The tracer magnet was placed near the tumor on the surface of the stomach through the operating hole after the conventional establishment of laparoscope puncture parallel mirror to explore the tracer magnet.After the two magnets were attracted,the location of the tracer magnet seen under the laparoscope was the location of the gastric tumor,so as to complete the labeling and positioning of the lesion.Results All the 6 Beagle dogs were successfully implanted with tracer magnets under gastroscopy.Twenty-four hours after the gastroscopy,the pursuit magnet was successfully implanted during laparoscopic surgery.The two magnets automatically attracted each other and formed a sandwich structure of "tracer magnet-gastric wall-pursuit magnet ",which completed the location and identification of gastric tumor under the laparoscopy.Conclusion Gastroscopy combined with laparoscopy based on magnetic tracer technique is simple,accurate,safe and feasible.
		                        		
		                        		
		                        		
		                        	
7.Diagnosis and treatment of abdominal cocoon: experience in 26 cases
Sheng LI ; Xianyan LIU ; Bo WEN ; Wei YAO ; Kanggui MA ; Weize TAN ; Senlin LIU
Chinese Journal of General Surgery 2020;35(4):300-303
		                        		
		                        			
		                        			Objective:To investigate the diagnosis and treatment of abdominal cocoon (AC).Methods:The clinical manifestations, findings during surgery, treatments, and follow-up results of 26 cases of AC were retrospectively studied from Jan 2001 to Jan 2019.Results:All of 26 cases were diagnosed as AC definitely by laparotomy, and were categorized into 2 types: type Ⅰ is of absence of second enterocoelia (18 cases, 69%) while type Ⅱ shows second enterocoelia (8cases, 31%). Twenty cases (12 type Ⅰ, 8 type Ⅱ) underwent membrane excision and careful enterodialysis to release the small intestine entirely or partially, while the other 6 cases (all were type Ⅰ) did not. All the patients recovered smoothly.Conclusions:AC can be categorized into two types, Surgery is recommended for type Ⅱ and part of type Ⅰ with severe complications.
		                        		
		                        		
		                        		
		                        	
8.Study of colorectal neoplasms localization based on magnetic tracer technique in an animal model
Yi LIN ; Qian FAN ; Jia MA ; Bo DENG ; Xingyi MOU ; Senlin ZHU ; Yuwei WU ; Shiran KANG ; Feng MA ; Yi LYU ; Xiaopeng YAN
Chinese Journal of Digestive Endoscopy 2020;37(7):499-502
		                        		
		                        			
		                        			Objective:To design magnets to locate colorectal neoplasms based on magnetic tracer technology, and to test its feasibility and safety by animal experiments.Methods:The magnets used for endoscopic localization of colorectal tumors consist of a tracer magnet and a pursuit magnet, both of which are ring-shaped Nd-Fe-B magnets. Eight healthy Beagle dogs were used as animal models. Tumor locations were assumed in the different parts of the colon and rectum under colonoscopy. The tracer magnet was sent to the hypothetical tumors by endoscopic soft tissue clamp and fixed near the tumors. After 24 hours, laparoscopic surgery was performed under general anesthesia. The pursuit magnet was inserted near the resected colon or rectum through the main operating hole. The tracer magnet was absorbed to the pursuit magnet to identify the location of tumors.Results:The tracer magnet and pursuit magnet were successfully designed and processed. The suction force between the tracer magnet and the pursuit magnet at zero distance was 16 N. All the 8 Beagle dogs successfully received indwelling of magnets under colonoscopy, and no magnets fell off after 24 hours. After the placement of pursuit magnet under laparoscopy, the two magnets attracted each other rapidly and accurately, and successfully completed localization of tumor site without any damage during the operation.Conclusion:Colonoscopy combined with laparoscopy for colorectal neoplasms localization based on magnetic tracer technique is simple, accurate, safe and feasible.
		                        		
		                        		
		                        		
		                        	
9.Establishment of gastrointestinal anastomosis by magnetic compression technique in rabbits
Yi LIN ; Lin JI ; Qian FAN ; Senlin ZHU ; Xingyi MOU ; Yuwei WU ; Yixing LI ; Bo DENG ; Yong ZHANG ; Feng MA ; Yi LYU ; Xiaopeng YAN
Chinese Journal of Digestive Endoscopy 2020;37(9):652-656
		                        		
		                        			
		                        			Objective:To study the feasibility of establishing gastrointestinal anastomosis by magnetic compression technique in rabbits.Methods:Ten healthy New Zealand rabbits were selected as models for gastrointestinal anastomosis by magnetic compression technique. Daughter and parent magnets suitable for gastrointestinal anastomosis in rabbits were designed and manufactured. A daughter magnet was inserted into the stomach through the purse fistula in the lack of blood vessel area of gastric body, and was pushed into the duodenum along the intestinal tract. And then a parent magnet was inserted through the stomach fistula. The daughter and parent magnets were automatically attracted and pressed the gastric and intestinal walls after they were adjusted in the proper position. The stomach fistula was closed with purse string suture. After ischemia, necrosis, detachment of the tissues between magnets, gastrointestinal anastomosis was established, and the magnets and necrotic tissues were expelled together from the body through the digestive tract. Survival of experimental animals was observed. Anastomotic specimens were obtained one month after operation. The blasting pressure of anastomotic stoma was measured, and the healing of anastomotic stoma was observed with naked eyes.Results:According to the pre-designed operative route, 10 New Zealand rabbits all successfully completed the operation and survived one month after surgery. No complications occurred during perioperative period. The operation time was 35.80±4.71 min (range 28.00-43.00 min), and the magnet discharge time was 11.40±1.56 days (range 9.00-14.00 days). Anastomotic specimens were obtained one month after the operation. Gross observation showed that the anastomotic stoma of gastrointestinal bypass anastomosis healed well, and the surrounding tissues adhered slightly. The anastomotic bursting pressure was 103.00±7.95 mmHg (range 94.00-113.00 mmHg) (1 mmHg=0.133 kPa).Conclusion:The establishment of gastrointestinal anastomosis by magnetic compression technique in rabbits is simple and effective.
		                        		
		                        		
		                        		
		                        	
10.miR-593 inhibits proliferation of colon cancer cells by down-regulating PLK1.
Jinzhu MA ; Yiping ZHU ; Zhen WANG ; Jiawei ZAN ; Long CAO ; Zunyong FENG ; Senlin WANG ; Qian FAN ; Liang YAN
Journal of Southern Medical University 2019;39(2):144-149
		                        		
		                        			OBJECTIVE:
		                        			To explore the role of miR-593 in regulating the proliferation of colon cancer cells and the molecular mechanism.
		                        		
		                        			METHODS:
		                        			Bioinformatics analysis identified PLK1 as the possible target gene of miR-593. Luciferase assay was employed to verify the binding between miR-593 and PLK1, and qRT-PCR and Western blotting were used to verify that PLK1 was the direct target gene of miR-593. CCK-8 assay was performed to test the hypothesis that miR-593 inhibited the proliferation of colon cancer cells by targeting PLK1.
		                        		
		                        			RESULTS:
		                        			Luciferase assay identified the specific site of miR-593 binding with PLK1. Western blotting showed a significantly decreased expression of PLK1 in the colon cancer cells transfected with miR-593 mimics and an increased PLK1 expression in the cells transfected with the miR-593 inhibitor as compared with the control cells ( < 0.05). The results of qRT-PCR showed no significant differences in the expression levels of PLK1 among the cells with different treatments ( > 0.05). The cell proliferation assay showed opposite effects of miR-593 and PLK1 on the proliferation of colon cancer cells, and the effect of co-transfection with miR-593 mimic and a PLK1-overexpressing plasmid on the cell proliferation was between those in PLK1 over-expressing group and miR-593 mimic group.
		                        		
		                        			CONCLUSIONS
		                        			miR-593 inhibits the proliferation of colon cancer cells by down-regulating PLK1 and plays the role as a tumor suppressor in colon cancer.
		                        		
		                        		
		                        		
		                        			Binding Sites
		                        			;
		                        		
		                        			Cell Cycle Proteins
		                        			;
		                        		
		                        			genetics
		                        			;
		                        		
		                        			metabolism
		                        			;
		                        		
		                        			Cell Line, Tumor
		                        			;
		                        		
		                        			Cell Proliferation
		                        			;
		                        		
		                        			Colonic Neoplasms
		                        			;
		                        		
		                        			metabolism
		                        			;
		                        		
		                        			pathology
		                        			;
		                        		
		                        			Down-Regulation
		                        			;
		                        		
		                        			Gene Expression Regulation, Neoplastic
		                        			;
		                        		
		                        			Genes, Tumor Suppressor
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			In Vitro Techniques
		                        			;
		                        		
		                        			MicroRNAs
		                        			;
		                        		
		                        			genetics
		                        			;
		                        		
		                        			metabolism
		                        			;
		                        		
		                        			Protein-Serine-Threonine Kinases
		                        			;
		                        		
		                        			genetics
		                        			;
		                        		
		                        			metabolism
		                        			;
		                        		
		                        			Proto-Oncogene Proteins
		                        			;
		                        		
		                        			genetics
		                        			;
		                        		
		                        			metabolism
		                        			;
		                        		
		                        			Reverse Transcriptase Polymerase Chain Reaction
		                        			;
		                        		
		                        			Sincalide
		                        			;
		                        		
		                        			metabolism
		                        			;
		                        		
		                        			Transfection
		                        			
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail