1.A prospective study on the safety and efficacy of excimer laser coronary angioplasty for the treatment of degenerated great saphenous vein graft.
Guang Yao ZHAI ; Tie Nan SUN ; Xiang LI ; Ming YE ; Cheng Gang WANG ; Xiao Lin ZU ; Duo YANG ; Hao FU ; Shu Ying QI ; Yu Jie ZHOU ; Hai GAO
Chinese Journal of Cardiology 2023;51(5):490-496
Objective: To explore the safety and efficacy of excimer laser coronary angioplasty (ELCA) for the treatment of degenerated great saphenous vein graft (SVG). Methods: This is a single-center, prospective, single-arm study. Patients, who were admitted to the Geriatric Cardiovascular Center of Beijing Anzhen Hospital from January 2022 to June 2022, were consecutively enrolled. Inclusion criteria were recurrent chest pain after coronary artery bypass surgery (CABG), and coronary angiography confirmed that the SVG stenosis was more than 70% but not completely occluded, and interventional treatment for SVG lesions was planned. Before balloon dilation and stent placement, ELCA was used to pretreat the lesions. Optical coherence tomography (OCT) examination was performed and postoperative index of microcirculation resistance (IMR) were assessed after stent implantation. The technique success rate and operation success rate were calculated. The technique success was defined as the successful passage of the ELCA system through the lesion. Operation success was defined as the successful placement of a stent at the lesion. The primary evaluation index of the study was IMR immediately after PCI. Secondary evaluation indexes included thrombolysis in myocardial infarction (TIMI) flow grade, corrected TIMI frame count (cTFC), minimal stent area and stent expansion measured by OCT after PCI, and procedural complications (Ⅳa myocardial infarction, no reflow, perforation). Results: A total of 19 patients aged (66.0±5.6) years were enrolled, including 18 males (94.7%). The age of SVG was 8 (6, 11) years. The length of the lesions was greater than 20 mm, and they were all SVG body lesions. The median stenosis degree was 95% (80%, 99%), and the length of the implanted stent was (41.7±16.3)mm. The operation time was 119 (101, 166) minutes, and the cumulative dose was 2 089 (1 378, 3 011)mGy. The diameter of the laser catheter was 1.4 mm, the maximum energy was 60 mJ, and the maximum frequency was 40 Hz. The technique success and the operation success rate were both 100% (19/19). The IMR after stent implantation was 29.22±5.95. The TIMI flow grade of patients after ELCA and stent implantation was significantly improved (all P>0.05), and the TIMI flow grade of all patients after stent implantation was Grade Ⅲ. The cTFC decreased significantly after ELCA (33.2±7.8) and after stent placement (22.8±7.1) than preoperative level (49.7±13.0) (both P<0.001). The minimum stent area was (5.53±1.36)mm2, and the stent expansion rate was (90.0±4.3)%. Perforation, no reflow, type Ⅳa myocardial infarction and other complications were not observed. However, postoperative high-sensitivity troponin level was significantly increased ((67.937±33.839)ng/L vs. (5.316±3.105)ng/L, P<0.001). Conclusion: ELCA is safe and effective in the treatment of SVG lesions and could improve microcirculation and ensure full expansion of stent.
Male
;
Humans
;
Aged
;
Prospective Studies
;
Percutaneous Coronary Intervention
;
Lasers, Excimer/therapeutic use*
;
Saphenous Vein/transplantation*
;
Constriction, Pathologic
;
Atherectomy, Coronary/methods*
;
Myocardial Infarction
;
Coronary Angiography
;
Stents
;
Treatment Outcome
2.An atypical presentation of leiomyosarcoma causing extremity compartment syndrome of the crural region in a Dutch Warmblood mare: a case report
Andrea GIACCHI ; Marco MARCATILI ; Jonathan WITHERS ; Derek KNOTTENBELT
Journal of Veterinary Science 2020;21(1):3-
saphenous vein (MSV) thrombophlebitis. A presumptive diagnosis of extremity compartment syndrome (ECS) was made. Due to the clinical deterioration, emergency fasciotomy of the crural fascia and biopsy was performed. Histological and immunohistochemical examination of the samples confirmed a diagnosis of leiomyosarcoma likely originating from the tunica media of the MSV. This report is the first to describe an unique combination of ECS and thrombophlebitis associated with a leiomyosarcoma in a horse.]]>
Animals
;
Biopsy
;
Child
;
Compartment Syndromes
;
Diagnosis
;
Emergencies
;
Extremities
;
Fascia
;
Hindlimb
;
Horses
;
Humans
;
Leiomyosarcoma
;
Saphenous Vein
;
Thrombophlebitis
;
Tunica Media
3.Numerical study on the mechanical coupling of external vascular stent and vein graft in coronary artery bypass surgery.
Journal of Biomedical Engineering 2020;37(6):983-989
External support stent is a potential means for restricting the deformation and reducing wall stress of the vein graft, thereby improving the long-term patency of the graft in coronary artery bypass surgery. However, there still lacks a theoretical reference for choosing the size of stent based on the diameter of graft. Taking the VEST (venous external support) stent currently used in the clinical practice as the object of study, we constructed three models of VEST stents with different diameters and coupled them respectively to a model of the great saphenous vein graft, and numerically simulated the expansion-contraction process of the vein graft under the constraint of the stents to quantitatively evaluate the influence of stent size on the radial deformation and wall stress of the vein graft. The results showed that while the stent with a small diameter had a high restrictive effect in comparison with larger stents, it led to more severe concentration of wall stress and sharper changes in radial deformation along the axis of the graft, which may have adverse influence on the graft. In order to solve the aforementioned problems, we ameliorated the design of the stent by means of changing the cross-sectional shape of the thick and thin alloy wires from circle into rectangle and square, respectively, while keeping the cross-sectional areas of alloy wires and stent topology unchanged. Further numerical simulations demonstrated that the ameliorated stent evidently reduced the degrees of wall stress concentration and abrupt changes in radial deformation, which may help improve the biomechanical environment of the graft while maintaining the restrictive role of the stent.
Alloys
;
Coronary Artery Bypass
;
Saphenous Vein/surgery*
;
Stents
4.Comparison of graft vessel versus native vessel strategies for late saphenous vein graft disease after coronary artery bypass grafting.
Xiao Wei LI ; Yin LIU ; Jing GAO ; Ming Dong GAO ; Jian Yong XIAO ; Zhi Ping QU ; Yue Ying WANG ; Li Juan FENG
Chinese Journal of Cardiology 2020;48(5):367-372
Objective: To compare clinical efficacy of interventional treatment with graft vessel and native coronary artery for patients with late saphenous vein grafts disease(SVGD) after coronary artery bypass grafting (CABG). Methods: A total of 1 608 patients underwent CABG in Tianjin Chest from March 2014 to December 2017 were screened. During the follow-up period, 165 hospitalized patients with recurrence of angina pectoris within one year after CABG, who had at least one narrow vein graft(≥50%) confirmed by the coronary angiography were enrolled. According to the results of angiography and surgeon's clinical experiences, the patients received interventional treatment to vein grafts(grafts group, n=53) or native coronary vessels(native group, n=112). The operation success rate, mortality and incidence of serious complications after interventional treatment in two groups at the time of hospitalization were compared.And the incidence of major adverse cardiovascular events(MACE) in two groups at one year after discharge were also compared. Kaplan-Meier survival curve was used to compare the cumulative event-free survival rates. The risk factors for the MACE in the patients with late SVGD and treated by interventional therapy were analyzed by Cox regression analysis. Results: A total of 165 patients were included for analysis, including 98 males(59.4%). The age was (64.2±7.1) years old. The follow-up time was 12 (8, 12) months. In the grafts group, operation success rate was 90.57%(48/53), and 3 cases(5.66%) suffered from serious complications after interventional treatment, 2 cases(3.77%) died. For native group the operation success rate was 88.39%(99/112), and 7(6.25%) cases suffered from serious complications after interventional treatment, and no deaths. The operation success rate and the incidences of serious complications after interventional treatment in two groups had no statistically significant difference(both P>0.05). The mortality in hospital of native group was lower than that in grafts group(P<0.05). Within 12 months after discharge, there was no statistically significant difference in incidence of MACE of two groups (11.32%(6/53) vs. 10.71%(12/112), P>0.05). Survival analysis showed that the cumulative event-free survival rates in two groups were 73.58% (39/53) and 66.13%(74/112), and there was no statistically significant difference (P>0.05). Cox regression analysis showed acute coronary syndrome (HR=41.203, 95%CI 4.859-349.361, P<0.01), and peripheral vascular diseases (HR=2.808, 95%CI 1.067-7.393, P<0.05) were the risk factors of the MACE for the patients treated by interventional therapy with late SVGD. Conclusion: For the patients with late SVGD after CABG, the success rate of intervention with vein grafts and own coronary vessels are both high with satisfactory safety.The in-hospital mortality of interventional therapy in own coronary vessels is lower than in graft vessel. Patients with acute coronary syndrome and peripheral vascular disease have a poor prognosis.
Aged
;
Coronary Angiography
;
Coronary Artery Bypass
;
Coronary Artery Disease/surgery*
;
Coronary Vessels
;
Female
;
Humans
;
Male
;
Middle Aged
;
Saphenous Vein
;
Time Factors
;
Treatment Outcome
7.Endovascular Repair of an Iliac Artery Pseudoaneurysm Using a Surgeon-Reconstructed Prosthetic Graft and a Bare Metal Stent
Vascular Specialist International 2019;35(1):34-38
Iliac artery aneurysms are usually asymptomatic. Herein, we report a novel strategy for the repair of a pseudoaneurysm involving the external iliac artery using a conventional artificial graft and bare metal stent. A 76-year-old male patient presented with severe resting pain and right foot discoloration. Computed tomography angiography revealed a right distal external iliac artery pseudoaneurysm, with severe calcified occlusion at the right common and superficial femoral arteries. After exposing the right femoral artery, long-segment endarterectomy and patch angioplasty with the ipsilateral greater saphenous vein were performed. Before the completion of patch angioplasty, a surgeon-modified 8-mm expanded polytetrafluoroethylene (ePTFE) graft was inserted for complete pseudoaneurysm repair. If a commercial covered stent is not available, minimally invasive endovascular repair can be safely performed using a surgeon-modified ePTFE graft and bare metal stent.
Aged
;
Aneurysm
;
Aneurysm, False
;
Angiography
;
Angioplasty
;
Endarterectomy
;
Femoral Artery
;
Foot
;
Humans
;
Iliac Artery
;
Male
;
Polytetrafluoroethylene
;
Prostheses and Implants
;
Saphenous Vein
;
Stents
;
Transplants
8.Risk Factors of Amputation in Lower Extremity Trauma with Combined Femoropopliteal Arterial Injury
JeaHwan KIM ; Yong Sun JEON ; Soon Gu CHO ; Kee Chun HONG ; Keun Myoung PARK
Vascular Specialist International 2019;35(1):16-21
PURPOSE: The clinical characteristics and results of femoropopliteal artery injury (FPAI) remain unclear. In this study, we evaluated the outcomes and risk factors of limb loss in patients treated for FPAI. MATERIALS AND METHODS: We retrospectively reviewed data from a database of patients who underwent revascularization for an FPAI at a single institution between January 2013 and December 2017. We reviewed and analyzed the characteristics, postoperative results, and factors that influence amputation rates. RESULTS: Twenty-four femoropopliteal arterial reconstructions in 24 patients were included in this study. Among the patients were 20 (83.3%) male with a first-quartile age of 28 years and a third-quartile age of 45 years (range, 15–68 years). The mean injury severity score (ISS) was 16 (range, 4–55), and 5 patients (20.8%) had ISSs of >20 points. The mean mangled extremity severity score (MESS) was 3.8 (range, 1–11), and 8 patients (33.3%) had MESSs of >5 points. In terms of arterial reconstruction methods, autogenous saphenous vein grafting, vein patching, and primary closure were performed in 9 patients (37.5%), 4 patients (16.7%), and 11 patients (45.8%), respectively. Despite arterial reconstruction, 5 patients (20.8%) underwent above-knee amputation. ISSs of >20, MESSs of >7, and orthopedic fixation were statistically significant factors associated with amputation. CONCLUSION: In cases of FPAI with ISSs of >20, MESSs of >7, and orthopedic fixation, amputations should be considered. We were also careful to attempt limb salvage in such cases.
Amputation
;
Amputation, Traumatic
;
Arteries
;
Extremities
;
Femoral Artery
;
Humans
;
Injury Severity Score
;
Limb Salvage
;
Lower Extremity
;
Male
;
Orthopedics
;
Popliteal Artery
;
Retrospective Studies
;
Risk Factors
;
Saphenous Vein
;
Transplants
;
Vascular System Injuries
;
Veins
9.Thrombosis of a Long-Segment Aneurysm from the Iliac to Popliteal Artery Associated with Arteriovenous Malformation and Varicose Veins
Chris Tae Young CHUNG ; Hyunmin KO ; Hyo Kee KIM ; Hyejin MO ; Ahram HAN ; Sanghyun AHN ; Sangil MIN ; Seung Kee MIN
Vascular Specialist International 2019;35(3):165-169
A 58-year-old male patient with severe claudication due to thrombosis of the left ilio-femoro-popliteal artery aneurysm. He also had a venous stasis ulcer with a history of multiple embolotherapy of arteriovenous malformation. Duplex sonography revealed reflux and varicose veins of the left great saphenous vein (GSV). A sequential bypass surgery was performed that consisted of excision of the left external iliac and common femoral artery aneurysm, external iliac to deep femoral interposition with an expanded polytetrafluoroethylene graft, and femoro-posterior tibial artery bypass with the reversed left GSV. Symptoms of claudication were alleviated and the chronic ulcer was healed in time. To our knowledge, this is the first report of successful bypass in a patient with arterial aneurysm, arteriovenous malformation, and venous insufficiency that can be diagnosed as an atypical case of Parkes Weber syndrome. Long-term follow-up is needed to define the fate of aneurysms and varicose vein graft.
Aneurysm
;
Arteries
;
Arteriovenous Fistula
;
Arteriovenous Malformations
;
Embolization, Therapeutic
;
Femoral Artery
;
Follow-Up Studies
;
Humans
;
Male
;
Middle Aged
;
Polytetrafluoroethylene
;
Popliteal Artery
;
Saphenous Vein
;
Sturge-Weber Syndrome
;
Thrombosis
;
Tibial Arteries
;
Transplants
;
Ulcer
;
Varicose Ulcer
;
Varicose Veins
;
Venous Insufficiency
10.Morphology of saphenous nerve in cadavers: a guide to saphenous block and surgical interventions
Anasuya GHOSH ; Subhramoy CHAUDHURY
Anatomy & Cell Biology 2019;52(3):262-268
The knowledge about detailed morphology and relation of saphenous nerve is important to obtain successful saphenous nerve regional blocks to achieve pre- and post-operative anesthesia and analgesia, nerve entrapment treatments and to avoid damage of saphenous nerve during knee and ankle surgeries. The literature describing detailed morphology of saphenous nerve is very limited. We dissected 42 formalin fixed well embalmed cadaveric lower limbs to explore detailed anatomy, relation and mode of termination of saphenous nerve and measured the distances from the nearby palpable bony landmarks. The average distance of origin of saphenous nerve from inguinal crease was 7.89±1.42 cm, the distance from upper end of medial border of patella to saphenous nerve at that level was 8.11±0.85 cm, distance from tibial tuberosity was 7.53±0.98 cm and from midpoint of anterior border of medial malleolus was 0.45±0.14 cm. Saphenous nerve provided two infrapatellar branches at the level of mid to lower limit of patellar ligament in 90% cases. It was in close contact or adhered to great saphenous vein across the lower 2/3rd of leg lying either anterior, posterior or deep to the vein. The saphenous nerve terminated by bifurcating proximal to medial malleolus in majority of cases though no obvious bifurcation was observed in 9.52% cases. The detailed morphology, relations and the distances from palpable bony landmarks may be helpful for clinicians to achieve successful saphenous nerve block and to avoid saphenous nerve damage and related complications during orthopedic procedures.
Anesthesia and Analgesia
;
Ankle
;
Cadaver
;
Deception
;
Formaldehyde
;
Knee
;
Leg
;
Lower Extremity
;
Nerve Block
;
Nerve Compression Syndromes
;
Orthopedic Procedures
;
Patella
;
Patellar Ligament
;
Saphenous Vein
;
Veins

Result Analysis
Print
Save
E-mail