1.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
2.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
3.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
4.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
5.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
6.Assessment of Eligibility and Utilization of Accelerated Partial Breast Irradiation in Korean Breast Cancer Patients (KROG 22-15)
Seok-Joo CHUN ; Ji Hwan JO ; Yong Bae KIM ; Sangjoon PARK ; Sung-Ja AHN ; Su Ssan KIM ; Kyubo KIM ; Kyung Hwan SHIN
Cancer Research and Treatment 2024;56(2):549-556
Purpose:
We investigated the proportions of patients eligible for accelerated partial breast irradiation (APBI) among those with pT1-2N0 breast cancer, based on the criteria set by the American Society for Radiation Oncology (ASTRO), the Groupe Européen de Curiethérapie and the European Society for Radiotherapy and Oncology (GEC-ESTRO), the American Brachytherapy Society (ABS), and the American Society of Breast Surgeons (ASBS). Additionally, we analyzed the rate of APBI utilization among eligible patients.
Materials and Methods:
Patients diagnosed with pT1-2N0 breast cancer in 2019 were accrued in four tertiary medical centers in Korea. All patients had undergone breast conserving surgery followed by radiotherapy, either whole breast irradiation or APBI. To determine which guideline best predicts the use of APBI in Korea, the F1 score and Matthews Correlation Coefficient (MCC) were determined for each guideline.
Results:
A total of 1,251 patients were analyzed, of whom 196 (15.7%) underwent APBI. The percentages of eligible patients identified by the ASTRO, GEC-ESTRO, ABS, and ASBS criteria were 13.7%, 21.0%, 50.5%, and 63.5%, respectively. APBI was used to treat 54.4%, 37.2%, 27.1%, and 23.7% of patients eligible by the ASTRO, GEC-ESTRO, ABS, and ASBS criteria, respectively. The ASTRO guideline exhibited the highest F1 score (0.76) and MCC (0.67), thus showing the best prediction of APBI utilization in Korea.
Conclusion
The proportion of Korean breast cancer patients who are candidates for APBI is substantial. The actual rate of APBI utilization among eligible patients may suggest there is a room for risk-stratified optimization in offering radiation therapy.
7.Sudden Death Associated With Possible Flare-Ups of Multiple Sclerosis After COVID-19 Vaccination and Infection: A Case Report and Literature Review
Yo Han JEON ; Sangjoon CHOI ; Ji Hyun PARK ; Jong Kyu LEE ; Nam Seok YEO ; SangHan LEE ; Yeon-Lim SUH
Journal of Korean Medical Science 2023;38(10):e78-
We present an autopsy case of a 19-year-old man with a history of epilepsy whose unwitnessed sudden death occurred unexpectedly in the night. About 4 years before death, he was diagnosed with unilateral optic neuritis (ON). Demyelinating disease was suspected, but he was lost to follow up after the recovery. Six months before death, he received a second dose of mRNA coronavirus disease 2019 (COVID-19) vaccine. Three months before death, he experienced epileptic seizures for the first time. Seventeen days before death, he was infected with COVID-19, which showed self-limited course under home isolation. Several days before death, he complained of seizures again at night. Autopsy revealed multifocal gray-tan discoloration in the cerebrum. Histologically, the lesions consisted of active and inactive demyelinated plaques in the perivenous area of the white matter. Perivascular lymphocytic infiltration and microglial cell proliferation were observed in both white matter and cortex. The other major organs including heart and lung were unremarkable. Based on the antemortem history and postmortem findings, the cause of death was determined to be multiple sclerosis with suspected exacerbation. The direct or indirect involvement of cortex and deep gray matter by exacerbated multiple sclerosis may explain the occurrence of seizures. Considering the absence of other structural abnormalities except the inflammatory demyelination of the cerebrum, fatal arrhythmia or laryngospasm in the terminal epileptic seizure may explain his sudden unexpected death in the benign circumstances. In this case, the onset of seizure was preceded by COVID-19 vaccination, and the exacerbation of seizure was preceded by COVID-19 infection, respectively. Literature reporting first manifestation or relapse of multiple sclerosis temporally associated with COVID-19 vaccination or infection are reviewed.
8.Rare Anatomic Variation of Anterior Communicating Artery Associated with a Rupture of Saccular Aneurysm
Yo Han JEON ; Sangjoon CHOI ; SangHan LEE ; Ji Hyun PARK ; Jong Kyu LEE ; Nam Seok YEO
Korean Journal of Legal Medicine 2023;47(2):58-61
Although most cerebral aneurysms are considered as acquired degenerative lesions, diverse anatomical variations in the circle of Willis have been encountered, some of which may play an important role in lesion hemodynamics and pathogenesis. The coalescence of the small vascular plexus to form the anterior communicating artery at the 6-7-week embryological stage may lead to developmental variations, such as fenestration and duplication. Herein, we report a rare anatomical variant of the anterior communicating artery that was concomitantly identified with a ruptured aneurysm. Both the right and left anterior cerebral arteries were connected by three anterior communicating arteries. A vertical segmental artery was present and connected the two anterior communicating arteries, forming an H-shape or plexiform structure. Furthermore, a 0.6×0.4 cm-sized saccular aneurysm with antero-inferior projection was present in the middle anterior communicating artery. The combination of triplication and H-shape in the present case was compared to previously reported anatomical variants.
9.Uterine Artery Embolization as an Effective Management and Diagnostic Tool for Puerperal Uterine Inversion with Severe Postpartum Bleeding: A Case Report
Seong Ju KIM ; Youngjong CHO ; Sung-Joon PARK ; Sangjoon LEE ; Hyoung Nam LEE ; Da Hye JU
Journal of the Korean Radiological Society 2022;83(3):699-704
Acute puerperal uterine inversion is a rare postpartum obstetric complication; however, without rapid diagnosis and appropriate management, it is life-threatening. Substantial bleeding hinders the verification of a partially inverted uterus, possibly delaying the treatment. Herein, we present the report of a 32-year-old female presenting with massive postpartum bleeding managed by uterine artery embolization. The peculiar course of the uterine artery bowing inferiorly along the inverted fundus during embolization could uncover the uterine inversion, which was not diagnosed by physical examination and CT. In conclusion, uterine artery embolization is not only an effective therapeutic strategy for postpartum hemorrhage but also a valuable tool for diagnosing uterine inversion.
10.Shallow Water Blackout (Hypoxic Blackout)–Induced Drowning: An Autopsy Report of Two Cases
Sangjoon CHOI ; SangHan LEE ; Yo Han JEON ; Ji Hyun PARK ; Jong Kyu LEE ; Nam Seok YEO
Korean Journal of Legal Medicine 2022;46(4):122-125
Shallow water blackout (SWB) is defined as loss of consciousness due to hypoxia during underwater swimming or breath-holding, usually in shallow waters. To date, no cases of SWB-induced drowning have been reported in the Republic of Korea. Here, we report two cases of SWB, followed by drowning, with autopsy findings. Two men, aged 20 (case 1) and 25 (case 2) years, suddenly lost their consciousness during underwater swimming and escape training, respectively. Postmortem examination revealed foamy fluid within trachea and bronchus, pulmonary edema, and sphenoid sinus fluid, which are commonly observed findings in drowning cases. None of the organs in either case showed pathologic alterations, except for hypoplastic coronary artery disease incidentally found in case 2. Pathologists should be aware of this distinct pathologic entity to avoid misdiagnosing the cause or manner of death.

Result Analysis
Print
Save
E-mail