1.Ethylene oxide residue detection method based on multi-component medical devices
Ruo-Jin LIU ; Zi-Meng WANG ; Hui LI ; Wen-Liang SHAO ; Bao-Yu LIU ; Yi FENG
Chinese Medical Equipment Journal 2024;45(1):56-61
Objective To establish a stable and reliable method for the determination of ethylene oxide residue,and to analyze ethylene oxide residue in multi components made of different materials involved in some medical devices,so as to provide references for sample selection and ethylene oxide residue detection of multi-component medical device kits.Methods A method for the determination of ethylene oxide residue of multi-component medical devices was developed using headspace-gas chromatography and DB-WAX column under the conditions of headspace extraction with equilibration at 80℃ for 20 min,and the weighing mass,linearity,limit of detection,limit of quantification,precision and recovery of the method were determined.Trials of the method were carried out on the items undergoing ethylene oxide sterilization,including disposable perineal care kit,disposable gynecological examination kit,disposable suture dressing kit,disposable debridement kit and the components contacting human body in the disposable dialysis kit,and the abilities of different materials of the components were analyzed in absorbing,retaining and releasing ethylene oxide.Results The method showed high linearity(r=0.999 8)in the range of ethylene oxide mass concentration from 0.4 to 16.0 μg/mL with a weighing mass of 1.00 g,which had the limit of detection being 0.11 μg/mL,the limit of quantification being 0.37 μg/mL and the relative standard deviations(RSDs)for the precision from 0.35%to 1.52%.The average recoveries of different spiked amounts of ethylene oxide in the three blank matrices ranged from 92.68%to 101.42%with the relative standard deviations(RSDs)from 2.46%to 7.59%,which all satisfied the detection requirements.The components made of rubber and acrylonitrile-butadiene-styrene copolymer(ABS)in multi-component medical device kits had the highest ethylene oxide residues,followed by the components made of wood,degreased cotton,polypropylene and polystyrene.Conclusion The method proposed gains advantages in easy operation and high specificity,quantification and reproducibility,which can be used for the determination of ethylene oxide residue in the multi-component medical device kit undergoing ethylene oxide sterilization.References are provided for sample selection of multi-component medical devices.[Chinese Medical Equipment Journal,2024,45(1):56-61]
2.Development,reliability and validity of nurses'knowledge,attitude and practice questionnaire on medication management for patients with dysphagia
Yi LIU ; Liqun ZHU ; Sheng SUI ; Ruo ZHUANG ; Yiyi NI ; Yuanyuan MI ; Lei BAO ; Li LI ; Lanping ZHENG ; Mengmeng CHEN
Chongqing Medicine 2024;53(5):738-744
Objective To develop nurses'knowledge,attitude and practice questionnaire on medication management for patients with dysphagia,and test its reliability and validity.Methods Based on the evidence-based summary of the best evidence of medication management for patients with dysphagia,guided by the the-ory of knowledge,attitude and practice,the basic dimensions and item pool of the questionnaire were deter-mined through group discussion,Delphi expert consultation and pre-investigation.In order to revise the ques-tionnaire,437 nurses from 10 tertiary hospitals in Jiangsu Province were conveniently selected for investigation,and the reliability and validity of the questionnaire were tested according to the survey results.Results The nurses'knowl-edge,attitude and practice questionnaire on medication management for patients with dysphagia included 43 items in three dimensions.The three dimensions were analyzed by exploratory factors,and six common factors with characteristic roots>1 were extracted.Two factors were extracted from the knowledge dimension,and the cumulative variance contribution rate was 74.958%,One factor was extracted from the attitude dimen-sion,and the cumulative variance contribution rate was 77.655%.Three factors were extracted from the prac-tice dimension,and the cumulative variance contribution rate was 72.274%.The factor load of each item was 0.618-0.902,Cronbach's α coefficient of the total questionnaire was 0.949,and the test-retest reliability was 0.909.The overall content validity coefficient of the questionnaire was 0.922,and the content validity coeffi-cient for each item was 0.800-1.000.Conclusion The nurses'knowledge,attitude and practice questionnaire on medication management for patients with dysphagia developed in this study has good reliability and validi-ty,and could be used as an effective tool to evaluate the status quo of nurses'medication management for pa-tients with dysphagia.
3.Target Residence of CRISPR/Cas in Genome Editing
Yi-Li FENG ; Ruo-Dan CHEN ; An-Yong XIE
Progress in Biochemistry and Biophysics 2024;51(10):2621-2636
The clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated protein 9 (Cas9) is widely used for targeted genomic and epigenomic modifications, transcriptional regulation and real-time cell imaging, and has already demonstrated great potential for applications in agriculture, industry and medicine. The promise of the technology depends upon the five intrinsic properties of CRISPR/Cas: targeting, target unwinding, target cutting, target residence, and collateral cleavage. Here, mainly using Streptococcus pyogenes CRISPR/Cas9 as example, we will focus on the target residence of CRISPR/Cas in applications of the CRISPR/Cas technology, summarize the recent progress, and discuss the effect of CRISPR/Cas target binding and residence on DNA double strand break repair pathway choices and the opportunities that CRISPR/Cas target residence presents to optimize the CRISPR/Cas technology.
4.Mechanism of R-spondin2 Regulating Wnt/β-catenin Signaling Pathway and Its Influence on Skeletal System
Jun-Jie JIN ; Jing LI ; Guang-Xuan HU ; Ruo-Meng WU ; Xue-Jie YI
Progress in Biochemistry and Biophysics 2024;51(3):544-554
R-spondin2 (Rspo2) is a member of protein family RSPOs, which can be coupled to receptor 4/5 (leucine-rich repeat-containing g protein-coupled receptor 4/5, LGR4/5), cell surface transmembrane E3 ubiquitin ligase ZNRF3/RNF43 (zinc and ring finger 3/ring finger protein 43), heparan sulfate proteoglycan (heparan sulfate proteoglycans, HSPGs) and the IQ motif (IQ gap 1) containing GTP enzyme activating protein 1, regulating the Wnt/β-catenin signaling pathway, which is the most widely studied signaling pathway and directly related to basic bone biology. Any problem in this pathway may have an impact on bone regulation. In recent years, it has been found that Rspo2 can act on osteoblast, osteoclast and chondrocytes through Wnt/β-catenin, and take part in occureace and development of some bone diseases such as ossification of the posterior longitudinal ligament (OPLL), osteoarthritis (OA) and rheumatoid arthritis (RA), so the study of Rspo2 may become a new therapeutic direction for bone-related diseases. Based on the latest research progress, this paper reviews the structure and main functions of Rspo2, the mechanism of Rspo2 regulating Wnt/β-catenin signaling pathway and its influence on skeletal system, in order to provide new ideas and ways for the prevention and treatment of bone-related diseases.
5.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]
6.Dosimetric effect of jaw widths on stereotactic body radiotherapy for hepatocellular carcinoma
Xia-Yu HANG ; Yi-Kun LI ; Jun HU ; Ruo-Qi CAO ; Yan ZHANG ; Nan XU ; Xian-Qiang SONG ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(7):51-55
Objective To investigate the radiotherapy dose impacts of different jaw widths on stereotactic body radiotherapy(SBRT)for hepatocellular carcinoma(HCC)with the hilical tomotherapy(HT)planning system.Methods Totally 16 HCC patients who received radiotherapy at some hospital from March 2021 to August 2023 were selected,and the planning was carried out with the same pitch,modulation factors and optimization conditions and the jaw widths being 1.0,2.5 and 5.0 cm.The dosimetric differences due to the jaw widths in planned targets and organs at risk(OAR)were compared,and the planned treatment time,monitor unit,gantry rotations and gantry period were evaluated.SPSS 22.0 was used for statistical analysis.Results Better dosimetric parameters and lower doses to OARs could be got with lower jaw widths.The widened jaw widths resulted in reduced planned treatment time,decreased monitor units and gantry rotations,shortened gantry period while enhanced treatment efficiency.Conclusion A 2.5 cm jaw width for HT planning contributes to improving treatment efficiency during HCC SBRT under the premise of ensured target dose distribution and satisfactory dose to OAR for clinical require-ments.[Chinese Medical Equipment Journal,2024,45(7):51-55]
7.Determination of 2-chloroethanol and ethylene glycol residues in disposable infusion sets
Ruo-Jin LIU ; Bao-Yu LIU ; Hui LI ; Yi FENG ; Wen-Liang SHAO
Chinese Medical Equipment Journal 2024;45(10):31-36
Objective To propose an effective method for the determination of 2-chloroethanol(ethylene chlorohydrin,ECH)and ethylene glycol(EG)residues in disposable infusion sets sterilized by ethylene oxide(EO).Methods Extraction with the ratio of the mass of the disposable infusion set to the volume of the medium being 0.4 g/mL was carried out with the 8890B gas chromatograph with liquid injection,DB-WAX column and ethanol extraction medium,and quantitative determination of ECH and EG in disposable infusion sets were implemented after extraction at 37℃for 10 h.Results The method proposely was highly specific,and showed high linearity in the range of 1.25-100.00 μg/mL for both ECH and EG.The limits of detection were 0.31 and 0.11 μg/mL for ECH and EG,respectively,and the relative standard deviations(RSD)of the precision of ECH was in the range of 0.24%-2.03%and those of EG was in the range of 0.16%-0.87%.The average recoveries were 95.02%-100.58%for ECH and 99.15%-99.98%for EG.Conclusion The method proposed for the determination of ECH and EG residues gains advantages in easy operation,specificity,detection accuracy and reproducibility,and meets the requirements for the determination of ECH and EG residues in EO-sterilized disposable infusion sets.[Chinese Medical Equipment Journal,2024,45(10):31-36]
8.Analysis of titer stability and inactivation kinetics of harvest solution of SARS-CoV-2
GUO Bing-feng ; HAN Bin ; HAO Yi-nan ; WANG Kui ; YIN Ji-xiang ; LI Yan ; LI Nan ; LING Xiang-ping ; PAN Ruo-wen
Chinese Journal of Biologicals 2023;36(2):129-132+144
Objective To investigate the titer stability of the harvest solution of severe acute respiratory syndrome coronavirus2(SARS-CoV-2)at 2 ~ 8 ℃ and the inactivation effect of β-propiolactone inactivator on the virus.Methods Three batches of SARS-CoV-2 harvest solution(batch numbers:202111001,202111002 and 202111003)were stored at 2 ~ 8 ℃ for 12 d and sampled every 3 d(0,3,6,9 and 12 d)for detection of the titers by Karber method;Three batches of virus harvest solution equilibrated overnight at 2 ~ 8 ℃ were inactivated by adding β-propiolactone at a volume fraction of 1∶4 000 and detected for the titers at different inactivation time points(0,0.5,1,1.5,2,3,4,8,16 and 24 h),of which samples inactivated for 8,16 and 24 h were taken for inactivation verification,and samples inactivated for 24 h were observed by transmission electron microscope.Results The titers of SARS-CoV-2 decreased with the prolongation of storage time at 2 ~8 ℃,which showed no obvious decrease during 0 ~ 3 d,while decreased from the initial 7.75,6 and 7.5 lgCCID_(50)/mL to5.75,4.625 and 6.25 lgCCID_(50)/mL on day 12,indicating that the virus activity showed a gradual decrease trend at 2 ~8 ℃;With the inactivation time,the virus titer decreased continuously and could not be detected after inactivation for 3 h.Transmission electron microscope observation showed that the inactivated virus particles were intact and the spike protein was evenly distributed.Conclusion The virulence of SARS-CoV-2 stored at 2 ~ 8 ℃ was unstable,so the subsequent inactivation and purification process should be carried out as soon as possible;The titer of virus could not be detected after3 h of inactivation,which provided a reference for the determination of the inactivation process.
9.Sleep-improving mechanisms of Jiu Wei Bu Xue Oral Liquid on regulating Glu/GABA balance in insomnia rats based on network pharmacology and experimental verification
Jie WEI ; Xiao-dong LAN ; Dong-mei LI ; Jun-hui HE ; Zhen MENG ; Dong-mei WEI ; Yi LI ; Fu-quan PENG ; Gui-ning WEI ; Ruo-gan HUANG
Acta Pharmaceutica Sinica 2023;58(6):1484-1495
This study aimed to investigate the mechanism of Jiu Wei Bu Xue Oral Liquid on insomnia rats combining the methods of network pharmacology, molecular docking and experimental verification. UPLC-Q-TOF-MS/MS method and TCMIP, TCMSP databases were used to collect the ingredients and targets of Jiu Wei Bu Xue Oral Liquid. Protein-protein interactions and network analysis were performed to screen the key network targets and putative active ingredients of Jiu Wei Bu Xue Oral Liquid in treatment of insomnia, and then following by biological function and KEGG pathway analysis. Then binding ability for key network targets and putative active ingredients were predicted with molecular docking. The prediction targets were validated in para-chlorophenylalanine (PCPA) induced insomnia rats with administration of Jiu Wei Bu Xue Oral Liquid (2, 4, 8 mL·kg-1) for 7 days. Pentobarbital sodium induced sleeping test were performed to evaluate the synergistic sleep-aiding effect of Jiu Wei Bu Xue Oral Liquid. Then glutamic acid (Glu),
10.Clinical analysis of 31 cases of fetal umbilical artery thrombosis.
Ruo An JIANG ; Ting XU ; Wen LI ; Ling Fei JIN ; Yi Min ZHOU ; Xiao Xia BAI ; Jing HE
Chinese Journal of Obstetrics and Gynecology 2023;58(7):495-500
Objective: To analyze the ultrasonic manifestations, clinical features, high risk factors and key points of pregnancy management in prenatal diagnosis of umbilical artery thrombosis (UAT). Methods: The data of 31 pregnant women of UAT diagnosed by prenatal ultrasonography and confirmed after birth from July 2017 to July 2022 at the Women's Hospital, Zhejiang University School of Medicine were retrospectively analyzed, including the maternal characteristics, pregnancy outcomes and fetal complications. In addition, the baseline data and pregnancy outcomes were compared in 21 patients who continued pregnancy after diagnosis of UAT. Of the 21 UAT cases that continued pregnancy, 10 cases were treated with low molecular weight heparin (LMWH; LMWH treatment group), while the other 11 patients had expectant treatment(expectant treatment group). Results: The age of the 31 pregnant women was (30.2±4.7) years, of which 5 cases (16%,5/31) were advanced age pregnant women. The gestational age at diagnosis was (32.9±4.0) weeks, and the gestational age at termination of pregnancy was (35.6±2.9) weeks. In 31 fetuses with UAT, 15 cases (48%) had fetal distress, 11 cases (35%) had fetal growth restriction, and 3 cases (10%) had intrauterine stillbirth. There were 28 cases of live births, including 26 cases by cesarean section and 2 cases by vaginal delivery. There were also 3 stillbirths, all delivered vaginally. Four neonates had mild asphyxia and two newborns had severe asphyxia. Among the 31 cases, 10 cases were terminated immediately after diagnosis, the gestational age at diagnosis was (35.9±2.9) weeks. Another 21 pregnancies continued, and their gestational age at diagnosis was (31.4±3.7) weeks. The median prolonged gestational age in LMWH treatment group was 7.9 weeks (4.6-9.4 weeks), and all were live births. The median prolonged gestational age in the expectant treatment group was 0.6 weeks (0.0-1.0 weeks), and 2 cases were stillbirths. There was a statistically significant difference in prolonged gestational age (P=0.002). Conclusions: Ultrasound is the preferred method for prenatal detection of UAT. Clinicians need to be vigilant for UAT when a newly identified single umbilical artery is detected by ultrasound in the second or third trimesters. The decision to continue or terminate the pregnancy depends on the gestational age and the condition of fetus. Attention should be paid to fetal movements as the pregnancy continues. The treatment of LMWH as soon as possible after diagnosis of UAT may improve the pregnancy outcome.
Pregnancy
;
Infant, Newborn
;
Female
;
Humans
;
Adult
;
Infant
;
Stillbirth
;
Cesarean Section
;
Umbilical Arteries/diagnostic imaging*
;
Asphyxia
;
Retrospective Studies
;
Heparin, Low-Molecular-Weight/therapeutic use*
;
Pregnancy Outcome
;
Fetal Growth Retardation/therapy*
;
Ultrasonography, Prenatal/methods*
;
Gestational Age


Result Analysis
Print
Save
E-mail