1.Ethylene oxide residue detection method based on multi-component medical devices
Ruo-Jin LIU ; Zi-Meng WANG ; Hui LI ; Wen-Liang SHAO ; Bao-Yu LIU ; Yi FENG
Chinese Medical Equipment Journal 2024;45(1):56-61
Objective To establish a stable and reliable method for the determination of ethylene oxide residue,and to analyze ethylene oxide residue in multi components made of different materials involved in some medical devices,so as to provide references for sample selection and ethylene oxide residue detection of multi-component medical device kits.Methods A method for the determination of ethylene oxide residue of multi-component medical devices was developed using headspace-gas chromatography and DB-WAX column under the conditions of headspace extraction with equilibration at 80℃ for 20 min,and the weighing mass,linearity,limit of detection,limit of quantification,precision and recovery of the method were determined.Trials of the method were carried out on the items undergoing ethylene oxide sterilization,including disposable perineal care kit,disposable gynecological examination kit,disposable suture dressing kit,disposable debridement kit and the components contacting human body in the disposable dialysis kit,and the abilities of different materials of the components were analyzed in absorbing,retaining and releasing ethylene oxide.Results The method showed high linearity(r=0.999 8)in the range of ethylene oxide mass concentration from 0.4 to 16.0 μg/mL with a weighing mass of 1.00 g,which had the limit of detection being 0.11 μg/mL,the limit of quantification being 0.37 μg/mL and the relative standard deviations(RSDs)for the precision from 0.35%to 1.52%.The average recoveries of different spiked amounts of ethylene oxide in the three blank matrices ranged from 92.68%to 101.42%with the relative standard deviations(RSDs)from 2.46%to 7.59%,which all satisfied the detection requirements.The components made of rubber and acrylonitrile-butadiene-styrene copolymer(ABS)in multi-component medical device kits had the highest ethylene oxide residues,followed by the components made of wood,degreased cotton,polypropylene and polystyrene.Conclusion The method proposed gains advantages in easy operation and high specificity,quantification and reproducibility,which can be used for the determination of ethylene oxide residue in the multi-component medical device kit undergoing ethylene oxide sterilization.References are provided for sample selection of multi-component medical devices.[Chinese Medical Equipment Journal,2024,45(1):56-61]
2.Effect of Centralized Procurement of Artificial Joints Consumables on Total Arthroplasty in a Grade A Ter-tiary Hospital
Junren YU ; Ruo JIANG ; Li LUO ; Zhijian LI
Chinese Hospital Management 2024;44(1):39-41
Objective To evaluate the effect of centralized procurement of artificial joint consumables on total arthro-plasty placement surgery.Methods Through a retrospective study,t-test was conducted on the medical quality and effi-ciency,hospitalization cost per time structure through July-December,2021 to July-December,2022 centralized pro-curement of joint replacement surgery in a tertiary hospital in Shanghai.Results After centralized procurement,the amount of knee arthroplasty surgery decreased,and the time of hip replacement surgery was increased,and the difference was statistically significant(P<0.05).The total cost,cost of consumables,arthrotomy fee of the two types of arthroplasty surgery were significantly decreased,and the difference was statistically significant(P<0.05).In addition,the average cost of other consumables hospitalization of knee joint surgery patient increased,and the difference was statistically significant(P<0.05).Conclusion After centralized procurement of artificial joint consumables,the cost of total knee arthroplasty and total hip arthroplasty has decreased significantly,and the quality and efficiency of medical care have not changed significantly.At the same time,hospital managers should pay more attention to the rational use of consumables after centralized procurement.In addition,it calls for increasing the price of surgery to reflect the value of physician services.
3.Correlation between Combined Urinary Metal Exposure and Grip Strength under Three Statistical Models: A Cross-sectional Study in Rural Guangxi
Jian Yu LIANG ; Hui Jia RONG ; Xiu Xue WANG ; Sheng Jian CAI ; Dong Li QIN ; Mei Qiu LIU ; Xu TANG ; Ting Xiao MO ; Fei Yan WEI ; Xia Yin LIN ; Xiang Shen HUANG ; Yu Ting LUO ; Yu Ruo GOU ; Jing Jie CAO ; Wu Chu HUANG ; Fu Yu LU ; Jian QIN ; Yong Zhi ZHANG
Biomedical and Environmental Sciences 2024;37(1):3-18
Objective This study aimed to investigate the potential relationship between urinary metals copper (Cu), arsenic (As), strontium (Sr), barium (Ba), iron (Fe), lead (Pb) and manganese (Mn) and grip strength. Methods We used linear regression models, quantile g-computation and Bayesian kernel machine regression (BKMR) to assess the relationship between metals and grip strength.Results In the multimetal linear regression, Cu (β=-2.119), As (β=-1.318), Sr (β=-2.480), Ba (β=0.781), Fe (β= 1.130) and Mn (β=-0.404) were significantly correlated with grip strength (P < 0.05). The results of the quantile g-computation showed that the risk of occurrence of grip strength reduction was -1.007 (95% confidence interval:-1.362, -0.652; P < 0.001) when each quartile of the mixture of the seven metals was increased. Bayesian kernel function regression model analysis showed that mixtures of the seven metals had a negative overall effect on grip strength, with Cu, As and Sr being negatively associated with grip strength levels. In the total population, potential interactions were observed between As and Mn and between Cu and Mn (Pinteractions of 0.003 and 0.018, respectively).Conclusion In summary, this study suggests that combined exposure to metal mixtures is negatively associated with grip strength. Cu, Sr and As were negatively correlated with grip strength levels, and there were potential interactions between As and Mn and between Cu and Mn.
4.Development and validation of dynamic prediction models using vital signs time series data for fatal massive hemorrhage in trauma
Cheng-Yu GUO ; Ming-Hui GONG ; Qiao-Chu SHEN ; Hui HAN ; Ruo-Lin WANG ; Hong-Liang ZHANG ; Jun-Kang WANG ; Chun-Ping LI ; Tan-Shi LI
Medical Journal of Chinese People's Liberation Army 2024;49(6):629-635
Objective To establish a dynamic prediction model of fatal massive hemorrhage in trauma based on the vital signs time series data and machine learning algorithms.Methods Retrospectively analyze the vital signs time series data of 7522 patients with trauma in the Medical Information Mart for Intensive Care-Ⅳ(MIMIC-Ⅳ)database from 2008 to 2019.According to the occurrence of posttraumatic fatal massive hemorrhage,the patients were divided into two groups:fatal massive hemorrhage group(n=283)and non-fatal massive hemorrhage group(n=7239).Six machine learning algorithms,including logistic regression(LR),support vector machine(SVM),random forests(RF),adaptive boosting(AdaBoost),gated recurrent unit(GRU),and GRU-D were used to develop a dynamic prediction models of fatal massive hemorrhage in trauma.The probability of fatal massive hemorrhage in the following 1,2,and 3 h was dynamically predicted.The performance of the models was evaluated by accuracy,sensitivity,specificity,positive predictive value,negative predictive value,Youden index,and area under receiver operating characteristic curve(AUC).The models were externally validated based on the trauma database of the Chinese PLA General Hospital.Results In the MIMIC-Ⅳ database,the set of dynamic prediction models based on the GRU-D algorithm was the best.The AUC for predicting fatal major bleeding in the next 1,2,and 3 h were 0.946±0.029,0.940±0.032,and 0.943±0.034,respectively,and there was no significant difference(P=0.905).In the trauma dataset,GRU-D model achieved the best external validation effect.The AUC for predicting fatal major bleeding in the next 1,2,and 3 h were 0.779±0.013,0.780±0.008,and 0.778±0.009,respectively,and there was no significant difference(P=0.181).This set of models was deployed in a public web calculator and hospital emergency department information system,which is convenient for the public and medical staff to use and validate the model.Conclusion A set of dynamic prediction models has been successfully developed and validated,which is greatly significant for the early diagnosis and dynamic prediction of fatal massive hemorrhage in trauma.
5.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]
6.Dosimetric effect of jaw widths on stereotactic body radiotherapy for hepatocellular carcinoma
Xia-Yu HANG ; Yi-Kun LI ; Jun HU ; Ruo-Qi CAO ; Yan ZHANG ; Nan XU ; Xian-Qiang SONG ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(7):51-55
Objective To investigate the radiotherapy dose impacts of different jaw widths on stereotactic body radiotherapy(SBRT)for hepatocellular carcinoma(HCC)with the hilical tomotherapy(HT)planning system.Methods Totally 16 HCC patients who received radiotherapy at some hospital from March 2021 to August 2023 were selected,and the planning was carried out with the same pitch,modulation factors and optimization conditions and the jaw widths being 1.0,2.5 and 5.0 cm.The dosimetric differences due to the jaw widths in planned targets and organs at risk(OAR)were compared,and the planned treatment time,monitor unit,gantry rotations and gantry period were evaluated.SPSS 22.0 was used for statistical analysis.Results Better dosimetric parameters and lower doses to OARs could be got with lower jaw widths.The widened jaw widths resulted in reduced planned treatment time,decreased monitor units and gantry rotations,shortened gantry period while enhanced treatment efficiency.Conclusion A 2.5 cm jaw width for HT planning contributes to improving treatment efficiency during HCC SBRT under the premise of ensured target dose distribution and satisfactory dose to OAR for clinical require-ments.[Chinese Medical Equipment Journal,2024,45(7):51-55]
7.Determination of 2-chloroethanol and ethylene glycol residues in disposable infusion sets
Ruo-Jin LIU ; Bao-Yu LIU ; Hui LI ; Yi FENG ; Wen-Liang SHAO
Chinese Medical Equipment Journal 2024;45(10):31-36
Objective To propose an effective method for the determination of 2-chloroethanol(ethylene chlorohydrin,ECH)and ethylene glycol(EG)residues in disposable infusion sets sterilized by ethylene oxide(EO).Methods Extraction with the ratio of the mass of the disposable infusion set to the volume of the medium being 0.4 g/mL was carried out with the 8890B gas chromatograph with liquid injection,DB-WAX column and ethanol extraction medium,and quantitative determination of ECH and EG in disposable infusion sets were implemented after extraction at 37℃for 10 h.Results The method proposely was highly specific,and showed high linearity in the range of 1.25-100.00 μg/mL for both ECH and EG.The limits of detection were 0.31 and 0.11 μg/mL for ECH and EG,respectively,and the relative standard deviations(RSD)of the precision of ECH was in the range of 0.24%-2.03%and those of EG was in the range of 0.16%-0.87%.The average recoveries were 95.02%-100.58%for ECH and 99.15%-99.98%for EG.Conclusion The method proposed for the determination of ECH and EG residues gains advantages in easy operation,specificity,detection accuracy and reproducibility,and meets the requirements for the determination of ECH and EG residues in EO-sterilized disposable infusion sets.[Chinese Medical Equipment Journal,2024,45(10):31-36]
8.Effect of Xiongcan Yishen Formula on ferroptosis in mouse TM3 Leydig cells after oxidative stress injury
A-Jian PENG ; Gang NING ; Hui WU ; Bo-Nan LI ; Ruo-Bing SHI ; Hao-Yu WANG ; Wei LIU ; Xue TANG ; Xing ZHOU
National Journal of Andrology 2024;30(7):640-647
Objective:To investigate the effects of Xiongcan Yishen Formula(XYF)on ferroptosis in mouse TM3 Leydig cells after oxidative stress injury(OSI)induced by H2O2.Methods:An oxidative stress injury model was established in mouse TM3 Leydig cells using H2O2 induction.The modeled TM3 cells were randomly divided into OSI group,XYF group,the ferroptosis inhibitor Ferrostatin-1(F-1)group,and F-1+XYF group,which were respectively intervened with blank serum,20%drug-containing serum,2μmol/L F-1,and2μmol/L F-1+20%drug-containing serum.A control group(normal TM3 cells+blank serum)was also set up.The morphology of cells in each group was observed,and the levels of testosterone,superoxide dismutase(SOD),reactive oxygen spe-cies(ROS),malondialdehyde(MDA),ferritin heavy chain 1(FTH1),solute carrier family 7 member 11(SLC7A11),glutathione(GSH),glutathione peroxidase 4(GPX4),fatty acid CoA ligase 4(FACL4),total iron ions,and ferrous ions were detected.Re-sults:Compared with the model group,the control group showed significantly decreased expression of ROS,MDA,FACL4,total iron,and ferrous ions(P<0.05),and significantly increased levels of testosterone,SOD,GSH,FTH1,SLC7A11,and GPX4(P<0.05).The male silkworm kidney-tonifying formula group significantly promoted testosterone secretion by TM3 cells and upregulated the expression of FTH1,SLC7A11,GPX4,GSH,and SOD in TM3 cells(P<0.05),while significantly downregulating ROS,MDA,FACL4,total iron ions,and ferrous ions(P<0.05).Conclusion:Following H2O2 exposure,oxidative stress can induce ferroptosis in mouse TM3 Leydig cells.XYF can antagonize OSI and ferroptosis in TM3 cells by activating the SLC7A11/GSH/GPX4 axis,which may underlie the mechanism of XYF in the treatment of male late-onset hypogonadism.
9.Research hotspots and trends of artificial intelligence in diabetic retinopathy based on bibliometrics and high-impact papers
Ruo-Yu WANG ; Wang-Ting LI ; Shao-Chong ZHANG ; Wei-Hua YANG
International Eye Science 2023;23(11):1803-1810
AIM: To analyze research hotspots and trends of artificial intelligence in diabetic retinopathy(DR)based on bibliometrics and high-impact papers.METHODS: Papers on artificial intelligence in DR research published in the Web of Science Core Collection(WoSCC)from January 1, 2012, to December 31, 2022 were retrieved. The data was analyzed by CiteSpace software to examine annual publication number, countries, institutions, source journal, research categories, keywords, and to perform an in-depth analysis of high-impact papers.RESULTS: A total of 1 009 papers on artificial intelligence in DR from 79 countries were included in the study, with 272 papers published in 2022. Notably, China and India contributed 287 and 234 papers, respectively. The United Kingdom exhibited a centrality score of 0.31, while the United States boasted an impressive H-index of 48. Three prominent institutions in the United Kingdom(University of London, Moorfields Eye Hospital, and University College London)and one institution in Egypt(Egyptian Knowledge Bank)all achieved a notable H-index of 14. The primary academic disciplines associated with this research field encompassed ophthalmology, computer science, and artificial intelligence. Burst keywords in the years 2021~2022 included transfer learning, vessel segmentation, and convolutional neural networks.CONCLUSION: China emerged as the leading contributor in terms of publication number in this field, while the United States stood out as a key player. Notably, Egyptian Knowledge Bank and University of London assumed leading roles among research institutions. Additionally, IEEE Access was identified as the most active journal within this domain. The research focus in the field of artificial intelligence in DR has transitioned from AI applications in disease detection and grading to a more concentrated exploration of AI-assisted diagnostic systems. Transfer learning, vessel segmentation, and convolutional neural networks hold substantial promise for widespread applications in this field.
10.Expression and significance of jumonji domain-containing protein 2B and hypoxia inducible factor-1α in non-Hodgkin lymphoma tissues in children.
Yu-Qiao DIAO ; Jian WANG ; Xiu-Li ZHU ; Jian CHEN ; Yu ZHENG ; Lian JIANG ; Yue-Ping LIU ; Ruo-Heng DAI ; Yi-Wei YAN
Chinese Journal of Contemporary Pediatrics 2023;25(11):1150-1155
OBJECTIVES:
To investigate the expression and significance of jumonji domain-containing protein 2B (JMJD2B) and hypoxia-inducible factor-1α (HIF-1α) in non-Hodgkin's lymphoma (NHL) tissues in children.
METHODS:
Immunohistochemistry was used to detect the expression of JMJD2B and HIF-1α in lymph node tissue specimens from 46 children with NHL (observation group) and 24 children with reactive hyperplasia (control group). The relationship between JMJD2B and HIF-1α expression with clinicopathological characteristics and prognosis in children with NHL, as well as the correlation between JMJD2B and HIF-1α expression in NHL tissues, were analyzed.
RESULTS:
The positive expression rates of JMJD2B (87% vs 21%) and HIF-1α (83% vs 42%) in the observation group were higher than those in the control group (P<0.05). The expression of JMJD2B and HIF-1α was correlated with serum lactate dehydrogenase levels and the risk of international prognostic index in children with NHL (P<0.05). The expression of JMJD2B was positively correlated with the HIF-1α expression in children with NHL (rs=0.333, P=0.024).
CONCLUSIONS
JMJD2B and HIF-1α are upregulated in children with NHL, and they may play a synergistic role in the development of pediatric NHL. JMJD2B can serve as a novel indicator for auxiliary diagnosis, evaluation of the severity, treatment guidance, and prognosis assessment in pediatric NHL.
Humans
;
Child
;
Hypoxia-Inducible Factor 1, alpha Subunit
;
Prognosis
;
Hypoxia
;
Lymphoma, Non-Hodgkin

Result Analysis
Print
Save
E-mail