1.Simultaneous determination of 13 aromatic amine compounds in workplace air by high performance liquid chromatography
Weimin XIE ; Ruibo MENG ; Zuofei XIE ; Jing YUAN ; Jiaheng HE ; Jiawen HU ; Weifeng RONG
China Occupational Medicine 2025;52(2):182-187
Objective To establish a liquid chromatography method for the simultaneous determination of 13 aromatic amine compounds (AAs) in workplace air. Methods A total of 13 AAs in both vapor and aerosol phases were collected in workplace air using a new GDH-6 sampling tube. Samples were desorbed and eluted with methanol, separated using a Symmetry Shield™ RP18 reversed-phase liquid chromatography column, and detected with a diode array detector. Quantification was performed using an external standard method. Results The linear range of the 13 AAs measured by this method was 0.02-373.60 μg/L with the correlation coefficients greater than 0.999 0. The minimum detection concentration was 0.09-14.37 μg/m3, and the minimum quantitative concentration was 0.31-47.90 μg/m3 (both calculated based on sampling 15.0 L of air and 3.0 mL of elution volume). The average desorption and elution efficiency ranged from 97.46% to 101.23%. The within-run relative standard deviation (RSD) was 0.10%-5.99%, and the between-run RSD was 0.17%-2.71%. Samples could be stably stored in sealed conditions at 2-8 ℃ for more than seven days. Conclusion This method is suitable for the simultaneous determination of 13 AAs in workplace air, including both vapor and aerosol phases.
2.Simultaneous determination of four thiol derivatives in workplace air by gas chromatography
Ruibo MENG ; Jing YUAN ; Jiawen HU ; Jiaheng HE ; Jingjing QIU ; Zuokan LIN ; Ziqun ZHANG ; Weifeng RONG ; Banghua WU
China Occupational Medicine 2025;52(2):188-192
Objective To establish a method for simultaneous determination of four high-molecular-weight thiol derivatives (TDs) in workplace air by gas chromatography. Methods The four kinds of vapor-phase macromolecular TDs (1-pentanethiol, 1-hexanethiol, 1-benzyl mercaptan, and n-octanethiol) in the workplace air were collected using the GDH-1 air sampling tubes, desorbed with anhydrous ethanol, separated on a DB-FFAP capillary column, and determined by flame ionization detector. Results The quantitation range of the four TDs was 0.30-207.37 mg/L, with the correlation coefficients greater than 0.999 00. The minimum detection mass concentrations and minimum quantitation mass concentrations were 0.18-0.32 and 0.60-1.05 mg/m3, respectively (both calculated based on the 1.5 L sample and 3.0 mL desorption solvent). The mean desorption efficiencies ranged from 87.07% to 103.59%. The within-run and between-run relative standard deviations were 1.92%-8.22% and 1.89%-8.45%, respectively. The samples can be stored at room temperature or 4 ℃ for three days and up to 7 days at -18 ℃. Conclusion This method is suitable for the simultaneous determination of four vapor-phase TDs in workplace air.
3.Guidelines on the Technical Plan for Emergency Health Response to Acute Gelsemium Poisoning
Jiaxin JIANG ; Ruibo MENG ; Zhongxiang GAO ; Rongzong LI ; Weifeng RONG ; Weihui LIANG ; Shibiao SU ; Jian HUANG ; Cheng JIN ; LlU XIAOYONG
China Occupational Medicine 2025;52(2):203-206
Acute Gelsemium poisoning is a systemic disease primarily affecting the central nervous system and respiratory symptoms caused by the ingestion of a substantial amount of Gelsemium within a short period. It manifests as sudden onset and rapid progression, primarily caused by accidental ingestion due to misidentification, and posing significant health risks. The compilation of the Technical Plan for Emergency Health Response to Acute Gelsemium Poisoning describes in detail the specialized practice and technical requirements in the process of handling acute Gelsemium poisoning, including accident investigation and management, laboratory testing and identification, in-hospital treatment, and health monitoring. The guidelines clarify key procedures and requirements such as personal protection, investigation elements, etiology determination, medical rescue, and health education. The key to acute Gelsemium poisoning investigation lies in promptly identifying the toxin through exposure history, clinical manifestations, and sample testing. Because there is no specific antidote for Gelsemium poisoning, immediate removal from exposure, rapid elimination of the toxin, and respiratory monitoring are critical on-site rescue measures. Visual identification of food or herbal materials, followed by laboratory testing to determine Gelsemium alkaloids in samples is a rapid effective screening method. These guidelines offer a scientific, objective, and practical framework to support effective emergency responses to acute Gelsemium poisoning incidences.
4.Analyzing the monitoring results of occupational hazards in the workplace of key industries in Guangdong Province, 2020-2023
Weifeng RONG ; Zuofei XIE ; Jiaheng HE ; Jing YUAN ; Jiawen HU ; Ruibo MENG ; Banghua WU
China Occupational Medicine 2024;51(1):54-59
ObjectiveTo understand the monitoring result of occupational hazard in the workplace of key industries in Guangdong Province from 2020 to 2023. Methods The data of occupational hazards in the workplace of 20 key industries in Guangdong Province from 2020 to 2023 were collected from the “Workplace Occupational Hazard Monitoring System” of the Chinese Disease Prevention and Control System subsystem. The monitoring result of occupational hazard factors, occupational health training, occupational health examination, occupational protection, detection of occupational hazardous agents such as dust, chemical substances and noise were analyzed. Results A total of 13 058 enterprises from key industries were recruited as the monitoring subjects in Guangdong Province. There were 290 large-, 1 342 medium-, 7 635 small-, and 3 791 micro-enterprises, with small and micro-enterprises accounting for 58.5% and 29.0% of the total, respectively. A total of 7 542 enterprises exceeded the national standard in the detection of occupational hazards, with a rate of 57.8%. A total of 1 942 517 workers from 13 058 enterprises were recruited, with 835 567 workers were exposed to occupational hazards, with a rate of 43.0%. The rate of occupational health training for enterprise leaders, occupational health management personnel, and workers was 71.9%, 73.8%, and 86.5%, respectively. The abnormal rate of occupational health examinations for workers exposed to noise, dust, and chemical agents was 2.0%, 0.6%, and 1.0%, respectively. The distribution rate of dust masks, anti-poisoning masks or face masks, and noise prevention earplugs or earmuffs was 83.3%, 71.3%, and 77.8%, respectively. The rate of installation of dust prevention facilities, anti-poisoning facilities, and noise prevention facilities was 85.6%, 81.2%, and 50.1%, respectively. The rate of exceeded the national standard of dust, noise in the worksites/types and workplaces showed a decreasing trend year by year (all P<0.01), while the rate of exceeded the national standard of chemical agents in worksites/types and workplaces showed an increasing trend year by year in various occupational hazards (all P<0.01). Conclusion Occupational hazards in the workplace of key industries in Guangdong Province are relatively common. The proportion of workers exposed to occupational hazards is relatively high. It is necessary to further improve the use of noise prevention facilities and protective equipment, strengthen occupational health training for enterprises throughout the province and regularly monitor occupational hazards to reduce the risk of occupational diseases.
5.Determination of two isomers of tetrachloroethane in urine by liquid-liquid extraction-gas chromatography
Fan WU ; Jiaheng HE ; Jing YUAN ; Ruibo MENG ; Weimin XIE ; Banghua WU ; Weifeng RONG
China Occupational Medicine 2024;51(1):85-89
ObjectiveTo establish a method for the determination of 1,1,1,2-tetrachloroethane (TeCA) and 1,1,2,2-TeCA in human urine using liquid-liquid extraction-gas chromatography. Methods The 5.0 mL urine sample was mixed with 2.0 g anhydrous sodium sulfate and 5.0 mL ethyl acetate, then vortexed mixing. The 1.0 mL extraction was separated by 100% dimethylpolysiloxane capillary gas chromatography column, detected by flame ionization detector, and quantified by an external standard method. Results The linear ranges of 1,1,1,2-TeCA and 1,1,2,2-TeCA were 0.250-50.750 mg/L, with both correlation coefficients of >0.999 9. The detection limit of 1,1,1,2-TeCA in urine was 0.020 mg/L, and the lower limit of quantification was 0.060 mg/L. The average recovery was 88.02%-101.32%, and the within-run and between-run relative standard deviations (RSDs) were 0.11%-0.47% and 0.39%-1.09%, respectively. The detection limit of 1,1,2,2-TeCA in urine was 0.050 mg/L, and the lower limit of quantification was 0.150 mg/L. The average recovery was 93.42%-101.32%, and the within-run and between-run RSDs were 0.28%-1.04% and 0.50%-1.03%, respectively. Both the 1,1,1,2-TeCA and 1,1,2,2-TeCA cannot be stored at room temperature. The 1,1,2,2-TeCA can be stored at 4 ℃ for at least three days. At -20 ℃, the 1,1,1,2-TeCA can only be stored for one day, while 1,1,2,2-TeCA can be stored for at least five days. Conclusion This method has high sensitivity, good specificity, simple sample pretreatment, and more intuitive and reliable results. It can be used to determine the level of 1,1,1,2-TeCA and 1,1,2,2-TeCA in urine of occupational population.
6.Qualitative analysis of volatile organic components in chemicals using headspace gas chromatography-mass spectrometry
Ruibo MENG ; Weifeng RONG ; Jiawen HU ; Jiaheng HE ; Jing YUAN ; Jingjing QIU ; Zuokan LIN ; Ziqun ZHANG ; Banghua WU
China Occupational Medicine 2023;50(3):325-329
Objective To establish a rapid qualitative analysis method for volatile organic components in chemicals. Methods Headspace gas chromatography-mass spectrometry was used to qualitatively determine 19 volatile organic components, including benzene, 1,2-dichloroethane, and n-hexane, in chemicals. Different sample amounts, heating temperatures, heating times, and sample volumes were analyzed to assess their effects on detection results and optimize sampling conditions. Results Based on the set chromatography, the optimal sampling process of this method was as follows: 5.0 g sample in a 20.0 mL headspace bottle, incubated at 40 ℃ for 30 minutes in a constant-temperature drying incubator, and a 1.00 mL headspace gas injection. The within-run and between-run relative standard deviations of all components ranged from 0.00% to 21.05% and 0.00% to 33.33%, respectively. The samples stored in sealed glass containers were stable at room temperature for at least 60 days. Conclusion This method offers simplicity, good reproducibility, and stability, making it suitable for rapid qualitative analysis of volatile organic components in chemicals.
7.Simultaneous determination of six aniline compounds in workplace air by high performance liquid chromatography
Ruibo MENG ; Jingjing QIU ; Weifeng RONG ; Weimin XIE ; Jing YUAN ; Jiaheng HE ; Jiawen HU ; Ziqun ZHANG ; Zuokan LIN ; Fan WU ; Banghua WU
China Occupational Medicine 2023;50(4):441-446
Objective To establish a high performance liquid chromatography (HPLC) method for simultaneous determination of six aniline compounds (ADs) in workplace air. Methods GDH-1 air sampling tube was used to collect six co-existing ADs such as aniline, o-toluidine, N-methylaniline, m-methylaniline, p-methylaniline and N,N-dimethylaniline in the vapor and aerosol of workplace air. The samples were desorbed and eluted using a methanol solution containing 1.00% ammonia water, followed by separation on a C18 chromatographic column and detection using a diode array detector. Results The quantification range of the method was 0.19 -253.50 mg/L, with the correlation coefficient of 0.999 9 for all six ADs. The minimum detection range was 0.02-0.06 mg/m3, and the minimum quantitation range was 0.04-0.19 mg/m3 [both calculated for a 15.0 L sample with a desorption (elution) solution volume of 3.00 mL]. The average desorption and elution efficiencies were 92.15%-104.41% (silica gel) and 94.29%-104.29% (filter membrane). The intra-assay relative standard deviation (RSD) ranged from 0.90%-9.72% (silica gel) and 0.57%-6.96% (filter membrane). The inter-assay RSD ranged from 2.03%-9.78% (silica gel) and 2.50%-8.62% (filter membrane). The samples were stable at room temperature for seven days. Conclusion This method can be used for the simultaneous determination of six ADs in workplace air.
8.Analysis of the regular monitoring of occupational hazards in Guangdong Province in 2022
Zuofei XIE ; Zuokan LIN ; Jiaheng HE ; Jing YUAN ; Jiawen HU ; Ruibo MENG ; Weifeng RONG ; Banghua WU ; Chuan WU
China Occupational Medicine 2023;50(4):466-471
Objective To analyze the overall situation of regular monitoring of occupational hazards in enterprises in Guangdong Province in 2022. Methods Analysis and quality sampling from enterprises were conducted on the occupational hazard regular monitoring reports submitted by various occupational health institutions through the Guangdong Province Occupational Health Quality Control Platform for the year 2022. Results In 2022, a total of 40 129 enterprises in Guangdong Province conducted regular monitoring of occupational hazards, accounting for 5.9%. More than 4.85 million workers were enrolled, of which more than 1.99 million workers were exposed to occupational hazards, with an incidence of 41.1%. The incidence of exposure to chemicals, dust, and noise were 18.2%, 11.9%, and 23.5%, respectively. The incidence of exceeding national standard for chemical substances, dust and noise in enterprises were 2.7%, 3.3%, and 42.7%, respectively. The incidence of exceeding national standard for all occupational hazards increased with the scale of enterprises from micro, small, medium to large enterprises (29.1% vs 46.7% vs 61.3% vs 65.4%, all P<0.05). The top three key industries, with more enterprises exceeding national standard, were metal furniture manufacturing, wooden furniture manufacturing, and other metal daily necessities manufacturing. The concentration of 97 chemical hazardous agents such as silica dust and benzene in work site exceeded the national standard, but less than 1.0% chemical hazardous agents exceeded national standard in most of the chemical-exposed work site. The incidence of noise exceeding national standard was 45.4%, while the incidence of silica dust exceeding national standard was 17.3%. Conclusion The percentage of regular monitoring of occupational hazards in enterprises in Guangdong Province is relatively low. The main occupational hazard that exceeds the national standard was noise, indicating the need for special attention on noise protection in workplace.
9.Determination of dimethyl carbonate in workplace air by solvent desorption-gas chromatography
Jiaheng HE ; Jing YUAN ; Weifeng RONG ; Jiawen HU ; Ruibo MENG ; Guanlin CHEN ; Banghua WU
China Occupational Medicine 2023;50(2):181-184
10.Determination of two isomers of tetrachloroethane by solvent desorption-gas chromatography in workplace air
Jing YUAN ; Weiming XIE ; Fan WU ; Jiaheng HE ; Jiawen HU ; Ruibo MENG ; Weifeng RONG ; Banghua WU ; Chuan WU
China Occupational Medicine 2023;50(2):185-188

Result Analysis
Print
Save
E-mail