1.Short-term effectiveness of arthroscopic repair via modified subacromial viewing portal in treatment of Lafosse Ⅰ subscapularis tendon tears.
Peiguan HUANG ; Bei WANG ; Guanghua TAN ; Xiaoxu WANG ; Liang HONG ; Zhi ZENG ; Mingjun QIU ; Huyong YAN ; Chunrong HE
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):22-27
OBJECTIVE:
To investigate short-term effectiveness of arthroscopic repair via modified subacromial viewing portal (hereinafter referred to as modified viewing portal) in treatment of LafosseⅠsubscapularis tendon tears.
METHODS:
A clinical data of 52 patients with LafosseⅠsubscapularis tendon tears, who underwent the arthroscopic repair via modified viewing portal between October 2020 and November 2022 and met the selective criteria, was retrospectively analyzed. There were 15 males and 37 females with an average age of 63.4 years (range, 41-76 years). Twelve patients had trauma history and the other 40 patients had no obvious inducement. The main clinical symptom was shoulder pain and the hug resistance tests were positive in all patients. The interval between symptom onset and admission ranged from 3 to 26 months (mean, 7.2 months). The shoulder pain and function were evaluated by visual analogue scale (VAS) score, American Shoulder and Elbow Surgeons (ASES) score, and University of California Los Angeles (UCLA) score before operation and at 12 months after operation. The shoulder range of motion (ROM) of forward flexion, abduction, and external rotation and the internal rotation strength were measured before operation and at 3 and 12 months after operation. MRI was performed at 3-6 months after operation to assess the tendon healing and the structural integrity and tension of reattached tendon. Patient's satisfactions were calculated at last follow-up.
RESULTS:
All incisions healed by first intention, no complication such as incision infection or nerve injury occurred. All patients were followed up 12-37 months (mean, 18.5 months). The VAS, UCLA, and ASES scores at 12 months after operation significantly improved when compared with those before operation ( P<0.05). The ROMs of abduction and forward flexion and the internal rotation strength at 3 and 12 months significantly improved when compared with those before operation ( P<0.05); and the ROMs at 12 months significantly improved compared to that at 3 months ( P<0.05). However, there was no significant difference ( P>0.05) in the ROM of external rotation at 3 months compared to that before operation; but the ROM at 12 months significantly improved compared to that before operation and at 3 months after operation ( P<0.05). Thirty-one patients underwent MRI at 3-6 months, of which 28 patients possessed intact structural integrity, good tendon tension and tendon healing; 3 patients underwent tendon re-tear. At last follow-up, 41 patients (78.8%) were very satisfied with the effectiveness, 7 were satisfied (13.5%), and 4 were dissatisfied (7.7%).
CONCLUSION
Arthroscopic repair via modified viewing portal for Lafosse Ⅰsubscapularis tendon tears, which can achieve the satisfactory visualization and working space, can obtain good short-term effectiveness with low overall re-tear risk.
Male
;
Female
;
Humans
;
Middle Aged
;
Rotator Cuff/surgery*
;
Rotator Cuff Injuries/surgery*
;
Shoulder Pain
;
Retrospective Studies
;
Treatment Outcome
;
Arthroscopy
;
Shoulder Joint/surgery*
;
Tendons/surgery*
;
Range of Motion, Articular
2.Study on injectable chitosan hydrogel with tendon-derived stem cells for enhancing rotator cuff tendon-to-bone healing.
Huawei WEN ; Qingsong ZHANG ; Ming TANG ; Ya'nan LI ; Hongfei TAN ; Yushun FANG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):91-98
OBJECTIVE:
To explore the effect of chitosan (CS) hydrogel loaded with tendon-derived stem cells (TDSCs; hereinafter referred to as TDSCs/CS hydrogel) on tendon-to-bone healing after rotator cuff repair in rabbits.
METHODS:
TDSCs were isolated from the rotator cuff tissue of 3 adult New Zealand white rabbits by Henderson step-by-step enzymatic digestion method and identified by multidirectional differentiation and flow cytometry. The 3rd generation TDSCs were encapsulated in CS to construct TDSCs/CS hydrogel. The cell counting kit 8 (CCK-8) assay was used to detect the proliferation of TDSCs in the hydrogel after 1-5 days of culture in vitro, and cell compatibility of TDSCs/CS hydrogel was evaluated by using TDSCs alone as control. Another 36 adult New Zealand white rabbits were randomly divided into 3 groups ( n=12): rotator cuff repair group (control group), rotator cuff repair+CS hydrogel injection group (CS group), and rotator cuff repair+TDSCs/CS hydrogel injection group (TDSCs/CS group). After establishing the rotator cuff repair models, the corresponding hydrogel was injected into the tendon-to-bone interface in the CS group and TDSCs/CS group, and no other treatment was performed in the control group. The general condition of the animals was observed after operation. At 4 and 8 weeks, real-time quantitative PCR (qPCR) was used to detect the relative expressions of tendon forming related genes (tenomodulin, scleraxis), chondrogenesis related genes (aggrecan, sex determining region Y-related high mobility group-box gene 9), and osteogenesis related genes (alkaline phosphatase, Runt-related transcription factor 2) at the tendon-to-bone interface. At 8 weeks, HE and Masson staining were used to observe the histological changes, and the biomechanical test was used to evaluate the ultimate load and the failure site of the repaired rotator cuff to evaluate the tendon-to-bone healing and biomechanical properties.
RESULTS:
CCK-8 assay showed that the CS hydrogel could promote the proliferation of TDSCs ( P<0.05). qPCR results showed that the expressions of tendon-to-bone interface related genes were significantly higher in the TDSCs/CS group than in the CS group and control group at 4 and 8 weeks after operation ( P<0.05). Moreover, the expressions of tendon-to-bone interface related genes at 8 weeks after operation were significantly higher than those at 4 weeks after operation in the TDSCs/CS group ( P<0.05). Histological staining showed the clear cartilage tissue and dense and orderly collagen formation at the tendon-to-bone interface in the TDSCs/CS group. The results of semi-quantitative analysis showed that compared with the control group, the number of cells, the proportion of collagen fiber orientation, and the histological score in the TDSCs/CS group increased, the vascularity decreased, showing significant differences ( P<0.05); compared with the CS group, the proportion of collagen fiber orientation and the histological score in the TDSCs/CS group significantly increased ( P<0.05), while there was no significant difference in the number of cells and vascularity ( P>0.05). All samples in biomechanical testing failed at the repair site during the testing process. The ultimate load of the TDSCs/CS group was significantly higher than that of the control group ( P<0.05), but there was no significant difference compared to the CS group ( P>0.05).
CONCLUSION
TDSCs/CS hydrogel can induce cartilage regeneration to promote rotator cuff tendon-to-bone healing.
Rabbits
;
Animals
;
Rotator Cuff/surgery*
;
Chitosan
;
Hydrogels
;
Rotator Cuff Injuries/surgery*
;
Wound Healing
;
Tendons/surgery*
;
Collagen
;
Stem Cells
;
Biomechanical Phenomena
3.Progress and prospect of biological treatment for rotator cuff injury repair.
Zhengbo YIN ; Zhian CHEN ; Ni YIN ; Yifei ZHU ; Bihuan ZHANG ; Tianhua ZHOU ; Hongbo TAN ; Yongqing XU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1169-1176
OBJECTIVE:
To review the research progress in biotherapy of rotator cuff injury in recent years, in order to provide help for clinical decision-making of rotator cuff injury treatment.
METHODS:
The literature related to biotherapy of rotator cuff injury at home and abroad in recent years was widely reviewed, and the mechanism and efficacy of biotherapy for rotator cuff injury were summarized from the aspects of platelet-rich plasma (PRP), growth factors, stem cells, and exosomes.
RESULTS:
In order to relieve patients' pain, improve upper limb function, and improve quality of life, the treatment of rotator cuff injury experienced an important change from conservative treatment to open surgery to arthroscopic rotator cuff repair. Arthroscopic rotator cuff repair plus a variety of biotherapy methods have become the mainstream of clinical treatment. All kinds of biotherapy methods have ideal mid- and long-term effectiveness in the repair of rotator cuff injury. The biotherapy method to promote the healing of rotator cuff injury is controversial and needs to be further studied.
CONCLUSION
All kinds of biotherapy methods show a good effect on the repair of rotator cuff injury. It will be an important research direction to further develop new biotherapy technology and verify its effectiveness.
Humans
;
Rotator Cuff Injuries/therapy*
;
Quality of Life
;
Arthroplasty
;
Exosomes
;
Neurosurgical Procedures
4.Early effectiveness of arthroscopic repair of supraspinatus tendon tears with douple-pulley suture-bridge.
Peiguan HUANG ; Bei WANG ; Guanghua TAN ; Xiaoxu WANG ; Zhi ZENG ; Mingjun QIU ; Huyong YAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(11):1380-1385
OBJECTIVE:
To investigate the early effectiveness of arthroscopic repair of supraspinatus tendon tears with douple-pulley suture-bridge.
METHODS:
The clinical data of 38 patients with supraspinatus tendon tears who met the selection criteria between September 2020 and July 2022 were retrospectively analyzed, and all of them were treated with arthroscopic double-pulley suture-bridge technique. There were 15 males and 23 females, aged from 43 to 77 years, with an average of 61.5 years. There were 15 cases of left shoulder and 23 cases of right shoulder. Seven cases had a history of trauma, and the other 31 cases had no obvious inducement. The main clinical symptoms of the patient were pain in lifting the shoulder joint and hug resistance test (+). The time from onset of symptoms to admission ranged from 6 to 19 months, with an average of 10.3 months. Flexion, abduction, and external rotation of the shoulder were recorded before operation and at 3 and 12 months after operation. Pain and function of the shoulder were evaluated by visual analogue scale (VAS) score, University of California Los Angeles (UCLA) shoulder score, and American Society of Shoulder and Elbow Surgeons (ASES) score before operation and at 12 months after operation. Tendon healing, tendon continuity, and tension were evaluated by MRI at 3-6 months after operation, and patient's satisfaction was evaluated at last follow-up.
RESULTS:
All the incisions healed by first intention, and there was no complication such as incision infection or nerve injury. All patients were followed up 12-34 months, with an average of 23.3 months. VAS score, UCLA shoulder score, and ASES score at 12 months after operation were significantly better than those before operation ( P<0.05). The external rotation range of shoulder joint significantly improved at 3 and 12 months after operation ( P<0.05), and it further improved at 12 months after operation when compared with 3 months after operation ( P<0.05). There was no significant difference in the range of flexion and abduction at 3 months after operation when compared with those before operation ( P>0.05), but the range of flexion and abduction at 12 months after operation significantly improved when compared with those before operation and at 3 months after operation ( P<0.05). MRI reexamination was performed in 28 patients at 3-6 months after operation. Among them, 25 patients had intact supraspinatus tendon structure, good tension, and tendon healing, and 3 patients had type 1 retear. The remaining 10 patients refused to undergo MRI reexamination because of the satisfactory effectiveness. At last follow-up, 29 patients (76.3%) were very satisfied with the results, 6 (15.7%) were satisfied, and 3 (7.8%) were not satisfied.
CONCLUSION
Arthroscopic double-pulley suture-bridge technique can achieve the effect of suture bridge operation, reduce the cost of operation and the risk of type 2 retear, and the early effectiveness is satisfactory, but the shoulder joint movement is limited within 3 months after operation.
Male
;
Female
;
Humans
;
Rotator Cuff/surgery*
;
Retrospective Studies
;
Treatment Outcome
;
Arthroscopy/methods*
;
Rotator Cuff Injuries/surgery*
;
Tendons/surgery*
;
Sutures
;
Suture Techniques
;
Pain/surgery*
;
Range of Motion, Articular
5.Early effectiveness of arthroscopic superior fulcrum reconstruction in treatment of irreparable massive rotator cuff tear.
Hongyan LI ; Run FANG ; Rende NING
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(12):1453-1458
OBJECTIVE:
To investigate early effectiveness of arthroscopic superior fulcrum reconstruction in the treatment of irreparable massive rotator cuff tear (IMRCT).
METHODS:
A retrospective analysis was conducted on the clinical data of 24 patients with IMRCT who met the inclusion criteria between January 2020 and April 2022. Among them, there were 11 males and 13 females with an average age of 56.2 years (range, 42-68 years). There were 12 cases of falling injuries, 3 cases of traction injuries, and the other 9 cases had no obvious causes. The disease duration ranged from 1 to 25 months (median, 6 months). The rotator cuff tears were classified as Hamada grade 2 in 18 cases and grade 3 in 6 cases, and Goutallier grade 1 in 3 cases, grade 2 in 20 cases, and grade 3 in 1 case. All patients were treated with arthroscopic superior fulcrum reconstruction. Visual analogue scale (VAS) score, Constant-Murley score, the University of California at Los Angeles (UCLA) score, and the American Shoulder and Elbow Surgeons (ASES) score were recorded before operation and at 1, 3, 6, and 12 months after operation.
RESULTS:
The operations were all successfully completed. The incisions healed by first intention and no related complications occurred. All patients were followed up 12-33 months (mean, 24.6 months). The VAS, Constant-Murley, UCLA, and ASES scores at different time points after operation were superior to those before operation ( P<0.05). All of the above indicators further improved with time. Except for no significant difference in VAS and Constant-Murley scores between 6 and 12 months ( P>0.05), the differences between the other time points were significant ( P<0.05). At 12 months after operation, according to UCLA scoring standard, shoulder joint function was rated as excellent in 4 cases, good in 19 cases, and poor in 1 case, with an excellent and good rate of 96.0%. MRI showed that there was no graft re-tear and the transplanted tendon and bone tunnel healed.
CONCLUSION
The arthroscopic superior fulcrum reconstruction for IMRCT can effectively relieve the pain, improve the shoulder range of motion, and restore good shoulder function.
Male
;
Female
;
Humans
;
Middle Aged
;
Rotator Cuff Injuries/surgery*
;
Rotator Cuff/surgery*
;
Retrospective Studies
;
Treatment Outcome
;
Arthroscopy
;
Shoulder Joint/surgery*
;
Range of Motion, Articular
6.Value of contrast-enhanced percutaneous ultrasound in the diagnosis of rotator cuff tear subtype.
Bi-Li LIU ; Yue SHAN ; Qi ZHONG ; Dan GE ; Yan-Ping LI ; Juan LYU ; Shu-Zhi GAN
China Journal of Orthopaedics and Traumatology 2023;36(10):974-981
OBJECTIVE:
To explore characteristics of contrast-enhanced ultrasound (CEUS) images features and diagnostic value of rotator cuff tear subtypes.
METHODS:
From January 2019 to March 2022, percutaneous ultrasound-guided subacromial bursography (PUSB) with persutaneous ultrasound-guide tendon lesionography (PUTL) was performed on 114 patients with suspected rotator cuff injury were evaluated, including 54 males and 60 females ranged in age from 35 to 75 years old with an average of (58.8±8.7 ) years old;76 patients on the right side and 38 patients on the left side;the course of disease ranged from 0.13 to 111 months with an average of (10.2±9.8) months. GE LOGIQ E9 color doppler ultrasound diagnostic high frequency(6 to 12 MHz) was used to CEUS Using arthroscopy as gold standard, receiver operating characteristic (ROC) curve was used to evaluate diagnostic efficacy of US, MRI and CEUS for rotator cuff injury, also sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated.
RESULTS:
The sensitivity of US in diagnosing full-thickness tears was 72.1%, specificity was 93.0%, and accuracy was 85.1%. The sensitivity, specificity and accuracy of MRI diagnosis of full-thickness tear were 90.9%, 92.6% and 92.1% respectively. The sensitivity, specificity and accuracy of CEUS in diagnosis of full-thickness tear were 100%. The sensitivity, specificity and accuracy of US in the diagnosis of partial tear were 85.7%, 77.2% and 79.8% respectively. The sensitivity, specificity and accuracy of MRI diagnosis of partial tear were 83.7%, 81.7% and 82.5% respectively. The sensitivity, specificity and accuracy of CEUS in diagnosis of partial tear were 95.7%, 92.6% and 93.9% respectively. There were significant differences in diagnosis results of US, MRI and CEUS for rotator cuff bursa tear (P<0.001). Kapp test showed good consistency between CEUS and arthroscopy in diagnosing rotator cuff tear subtypes (full-thickness and partial tears).
CONCLUSION
Using PUSB/PUTL to observe distribution of contrast media in bursa, tendon and joint cavity to evaluate the type of rotator cuff tear, its diagnostic performance is significantly better than US and MRI. Therefore, percutaneous contrast-enhanced ultrasound can be a reliable method for diagnosing subtypes of rotator cuff tears.
Male
;
Female
;
Humans
;
Infant, Newborn
;
Infant
;
Child, Preschool
;
Child
;
Rotator Cuff Injuries/diagnostic imaging*
;
Rotator Cuff/diagnostic imaging*
;
Sensitivity and Specificity
;
Ultrasonography
;
Magnetic Resonance Imaging/methods*
;
Rupture
;
Arthroscopy
7.Pro-oxidation status of rotator cuff tissue and expression of Beclin-1 and mTOR in patients with rotator cuff injury.
Zhi-Jun LIU ; He-Wei WEI ; Wei-Peng ZHENG ; Lei WAN ; Zhi-Hao LIAO ; Sheng CHEN
China Journal of Orthopaedics and Traumatology 2023;36(12):1136-1141
OBJECTIVE:
To explore pro-oxidative state of rotator cuff tissue and expression levels of Beclin-1 and mam-malian target of rapamycin(mTOR) in patients with acute and chronic rotator cuff injury, and then analyzed relationship between rotator cuff injury and oxidative stress and autophagy.
METHODS:
Forty patients with rotator cuff injury were seleceted from July 2019 to December 2020, and divided into male chronic injury group, male acute injury group, female chronic injury group, and female acute injury group, 10 patients in each group. All patients were performed rotator cuff repair under arthroscopy. The sample of tendon at the rotator cuff injury site of the patient was taken during operation, and total reactive oxygen species (ROS) and superoxide dismutase(SOD) were detected by detection kit;expression of Beclin-1 and mTOR mRNA were detected by reverse transcription-polymerase chain reaction (RT-PCR), and Western-blot was applied to detect protein expression of Beclin-1 and p-mTOR/mTOR.
RESULTS:
There were no significant difference in expression of ROS, SOD, Beclin-1mRNA and mTOR mRNA between male and female chronic injury groups, and between male and female acute injury groups (P>0.05); ROS, SOD and Beclin-1mRNA in male chronic injury group were higher than those in male chronic injury group, while mTOR mRNAand protein decreased (P<0.05);ROS, SOD and Beclin-1 mRNA in female chronic injury group were up-regulated compared with female acute injury group, while mTOR mRNA was down-regulated (P<0.05).
CONCLUSION
Chronic rotator cuff injury is more likely to stimulate the pro-oxidation state of rotator cuff tissue than acute rotator cuff injury, which could up-regulating expression of autophagy factor Beclin-1 and down-regulating expression of mTOR. Therefore, patients with chronic rotator cuff injury may have higher levels of oxidative stress and autophagy.
Female
;
Humans
;
Male
;
Beclin-1/metabolism*
;
Reactive Oxygen Species/metabolism*
;
RNA, Messenger/metabolism*
;
Rotator Cuff/surgery*
;
Rotator Cuff Injuries/surgery*
;
Superoxide Dismutase/metabolism*
;
TOR Serine-Threonine Kinases/metabolism*
8.Arthroscopic assistance of latissimus dorsi tendon transposition for the treatment of unrepairable rotator cuff tear.
Guang XU ; Xue-Wu SUN ; Jian CHEN ; Bei-Hao GU ; Zhi-Jie ZHOU ; Pei-Hua SHI
China Journal of Orthopaedics and Traumatology 2023;36(12):1153-1158
OBJECTIVE:
To explore clinical effect of arthroscopy-assisted rotator cuff tendon transfer in treating irreparable rotator cuff tears (IRCT).
METHODS:
From May 2015 to May 2018, 23 patients with unrepairable rotator cuff tears were treated with arthroscopy-assisted rotator cuff tendon transfer, and 21 patients were followed up finally, including 8 males and 13 females, aged from 48 to 82 years old with an average of(64.3±9.1) years old;the courses of disease ranged from 6 to 36 months with an average of (14.0±6.4) months. American Rotator and Elbow Surgeons Score(ASES) and Constant-Murley score were used to evaluate clinical efficacy before surgery and at the latest follow-up.
RESULTS:
All 21 patients were followed up for 36 to 54 months with an average of (39.4±4.4) months. Axillary incision of 1 patient was redness, swelling and exudation after surgery, which healed after 3 weeks of dressing change, and exudate culture was negative. At the latest follow-up, MRI showed partial tearing of the metastatic tendon in 2 patients, but pain and movement of the affected shoulder were still better than before surgery. ASES increased from preoperative (41.0±9.6) scores to the latest follow-up (75.6±14.0) scores, and had statistical difference (t=10.50, P<0.01). Constant-Murley score increased from (49.8±7.1) scores before operation to (67.5±11.6) scores at the latest follow-up (t=11.27, P<0.01).
CONCLUSION
Arthroscopic assisted latissimus dorsalis tendon transposition restores physiological and anatomical structure of glenohumeral joint by reconstructing balance of horizontal and vertical couples of shoulder joint, thus achieving the stability of the shoulder joint, relieving shoulder pain and improving shoulder joint function.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Rotator Cuff Injuries/surgery*
;
Superficial Back Muscles
;
Rotator Cuff
;
Treatment Outcome
;
Shoulder Joint/surgery*
;
Tendon Transfer
;
Arthroscopy
;
Range of Motion, Articular/physiology*
9.Meta-analysis of obesity on the outcome of rotator cuff repair.
Jun-Wen LIANG ; Zhi-Tao YANG ; Tao LIU ; Xi-Hao WANG ; Sen FANG ; Bai-Rong ZHANG ; Xiang-Dong YUN
China Journal of Orthopaedics and Traumatology 2023;36(12):1196-1202
OBJECTIVE:
To systematically evaluate obesity on the outcome of rotator cuff repair.
METHODS:
Literatures on the relationship between obesity and outcomes after rotator cuff repair were searched from PubMed, Embase, Cochrane Library, Web of Science, China biology medicine(CBM), CNKI, Wanfang and VIP databases from building database to August 1, 2022, and were screened independently by two authors according to inclusion and exclusion criteria. Endnote X9 and Excel 2019 were used for literature extraction, management and data entry, and Newcastle-Ottawa Scale (NOS) was used to evaluate quality of the included literatures. STATA 16.0 and RevMan 5.4 softwares were used to evaluate postoperative retear rate, reoperation rate, complication rate, American Shoulder and Elbow Surgeons (ASES) score, visual analogue scale (VAS), operative time and external rotation angle of shoulder joint pain were analyzed.
RESULTS:
Totally 13 literatures were included, including 6 retrospective studies, 5 case-control studies, 1 prospective cohort study, and 1 abstract of a study for which the full text was not available, with 85 503 patients (31 973 in obese group and 53 530 in non-obese group). Meta-analysis showed there were statistical differences between two groups in retear rate [OR=2.58, 95%CI(1.23, 5.41), P=0.01], reoperation rate[OR=1.31, 95%CI(1.21, 1.42), P<0.00], complication rate [OR=1.57, 95%CI(1.31, 1.87), P=0.00], ASES score[MD=-3.59, 95%CI(-5.45, -1.74), P=0.00], and VAS[MD=0.24, 95%CI(0.00, 0.49), P=0.05]. While there were no differences between two groups in operative time[MD=6.03, 95%CI(-7.63, 19.69), P=0.39], external rotation angle of shoulder joint[MD=-1.79, 95%CI(-5.30, 1.71), P=0.32].
CONCLUSION
Obesity is associated with higher rates of retear, resurgery, complications, poorer shoulder function and pain after rotator cuff repair.
Humans
;
Rotator Cuff/surgery*
;
Rotator Cuff Injuries/complications*
;
Retrospective Studies
;
Prospective Studies
;
Treatment Outcome
;
Shoulder Pain
;
Obesity/surgery*
;
Arthroscopy
10.The rotator cuff footprint in Filipinos: A cadaveric study
Patrick M. Dizon ; Karissa Arielle F. Genuino-Regalado ; Donnel Alexis T. Rubio ; Rowena F. Genuino ; Julius Bryan C. Abesamis
Acta Medica Philippina 2023;57(10):65-70
Introduction:
Rotator cuff tears are one of the common etiologies of shoulder pain. Rotator cuff repair is recommended for a patient who failed conservative treatment. Proper knowledge of the rotator cuff footprint is needed in restoring correct anatomy during the repair. The size of the footprint is important in determining the kind of repair.
Objective:
This study aimed to define the average measurements of the rotator cuff footprint on the humerus in Filipino cadavers.
Methods:
This is a descriptive, cross-sectional study of preserved human cadaver upper extremity specimens. We measured the length, width, and shape of the supraspinatus, infraspinatus, subscapularis, and teres minor.
Results:
We obtained 27 upper extremity specimens. The median age of the source cadavers was 50.5 years with the equal male-to-female distribution. The mean measurement of the supraspinatus is 22.92 mm in length and 10.17 mm in width. The shape of the supraspinatus was found to be trapezoidal. The infraspinatus length was found to be 17.20 mm and the width at 10.72 mm. Its shape was found to be trapezoidal. The teres minor length was measured at 15.15 mm and the width at 11.04 mm. The shape was mostly trapezoidal but some were triangular. Finally, the subscapularis length was 17.68 mm while the width was 11.26 mm. The shape was trapezoidal or comma-shaped.
Conclusion
The average measurement of the rotator cuff footprint was found to be smaller in our study than reported in terms of length and width. The footprint shape was similar to the studies reported.
Rotator Cuff


Result Analysis
Print
Save
E-mail