1.Long-term Outcomes of Endoscopic Radiofrequency Ablation versus Endoscopic Submucosal Dissection for Widespread Superficial Esophageal Squamous Cell Neoplasia
Xin TANG ; Qian-Qian MENG ; Ye GAO ; Chu-Ting YU ; Yan-Rong ZHANG ; Yan BIAN ; Jin-Fang XU ; Lei XIN ; Wei WANG ; Han LIN ; Luo-Wei WANG
Gut and Liver 2025;19(2):198-206
Background/Aims:
Endoscopic radiofrequency ablation (ERFA) is a treatment option for superficial esophageal squamous cell neoplasia (ESCN), with a relatively low risk of stenosis; however, the long-term outcomes remain unclear. We aimed to compare the long-term outcomes of patients with widespread superficial ESCN who underwent endoscopic submucosal dissection (ESD) or ERFA.
Methods:
We retrospectively analyzed the clinical data of patients with superficial ESCN who underwent ESD or ERFA between January 2015 and December 2021. The primary outcome measure was recurrence-free survival.
Results:
Ninety-two and 33 patients with superficial ESCN underwent ESD and ERFA, respectively. The en bloc, R0, and curative resection rates for ESD were 100.0%, 90.2%, and 76.1%, respectively. At 12 months, the complete response rate was comparable between the two groups (94.6% vs 90.9%, p=0.748). During a median follow-up of 66 months, recurrence-free survival was significantly longer in the ESD group than in the ERFA group (p=0.004), while no significant differences in overall survival (p=0.845) and disease-specific survival (p=0.494) were observed.Preoperative diagnosis of intramucosal cancer (adjusted hazard ratio, 5.55; vs high-grade intraepithelial neoplasia) was an independent predictor of recurrence. Significantly fewer patients in the ERFA group experienced stenosis compare to ESD group (15.2% vs 38.0%, p=0.016).
Conclusions
The risk of recurrence was higher for ERFA than ESD for ESCN but overall survival was not affected. The risk of esophageal stenosis was significantly lower for patients who underwent ERFA.
2.Long-term Outcomes of Endoscopic Radiofrequency Ablation versus Endoscopic Submucosal Dissection for Widespread Superficial Esophageal Squamous Cell Neoplasia
Xin TANG ; Qian-Qian MENG ; Ye GAO ; Chu-Ting YU ; Yan-Rong ZHANG ; Yan BIAN ; Jin-Fang XU ; Lei XIN ; Wei WANG ; Han LIN ; Luo-Wei WANG
Gut and Liver 2025;19(2):198-206
Background/Aims:
Endoscopic radiofrequency ablation (ERFA) is a treatment option for superficial esophageal squamous cell neoplasia (ESCN), with a relatively low risk of stenosis; however, the long-term outcomes remain unclear. We aimed to compare the long-term outcomes of patients with widespread superficial ESCN who underwent endoscopic submucosal dissection (ESD) or ERFA.
Methods:
We retrospectively analyzed the clinical data of patients with superficial ESCN who underwent ESD or ERFA between January 2015 and December 2021. The primary outcome measure was recurrence-free survival.
Results:
Ninety-two and 33 patients with superficial ESCN underwent ESD and ERFA, respectively. The en bloc, R0, and curative resection rates for ESD were 100.0%, 90.2%, and 76.1%, respectively. At 12 months, the complete response rate was comparable between the two groups (94.6% vs 90.9%, p=0.748). During a median follow-up of 66 months, recurrence-free survival was significantly longer in the ESD group than in the ERFA group (p=0.004), while no significant differences in overall survival (p=0.845) and disease-specific survival (p=0.494) were observed.Preoperative diagnosis of intramucosal cancer (adjusted hazard ratio, 5.55; vs high-grade intraepithelial neoplasia) was an independent predictor of recurrence. Significantly fewer patients in the ERFA group experienced stenosis compare to ESD group (15.2% vs 38.0%, p=0.016).
Conclusions
The risk of recurrence was higher for ERFA than ESD for ESCN but overall survival was not affected. The risk of esophageal stenosis was significantly lower for patients who underwent ERFA.
3.Long-term Outcomes of Endoscopic Radiofrequency Ablation versus Endoscopic Submucosal Dissection for Widespread Superficial Esophageal Squamous Cell Neoplasia
Xin TANG ; Qian-Qian MENG ; Ye GAO ; Chu-Ting YU ; Yan-Rong ZHANG ; Yan BIAN ; Jin-Fang XU ; Lei XIN ; Wei WANG ; Han LIN ; Luo-Wei WANG
Gut and Liver 2025;19(2):198-206
Background/Aims:
Endoscopic radiofrequency ablation (ERFA) is a treatment option for superficial esophageal squamous cell neoplasia (ESCN), with a relatively low risk of stenosis; however, the long-term outcomes remain unclear. We aimed to compare the long-term outcomes of patients with widespread superficial ESCN who underwent endoscopic submucosal dissection (ESD) or ERFA.
Methods:
We retrospectively analyzed the clinical data of patients with superficial ESCN who underwent ESD or ERFA between January 2015 and December 2021. The primary outcome measure was recurrence-free survival.
Results:
Ninety-two and 33 patients with superficial ESCN underwent ESD and ERFA, respectively. The en bloc, R0, and curative resection rates for ESD were 100.0%, 90.2%, and 76.1%, respectively. At 12 months, the complete response rate was comparable between the two groups (94.6% vs 90.9%, p=0.748). During a median follow-up of 66 months, recurrence-free survival was significantly longer in the ESD group than in the ERFA group (p=0.004), while no significant differences in overall survival (p=0.845) and disease-specific survival (p=0.494) were observed.Preoperative diagnosis of intramucosal cancer (adjusted hazard ratio, 5.55; vs high-grade intraepithelial neoplasia) was an independent predictor of recurrence. Significantly fewer patients in the ERFA group experienced stenosis compare to ESD group (15.2% vs 38.0%, p=0.016).
Conclusions
The risk of recurrence was higher for ERFA than ESD for ESCN but overall survival was not affected. The risk of esophageal stenosis was significantly lower for patients who underwent ERFA.
4.Long-term Outcomes of Endoscopic Radiofrequency Ablation versus Endoscopic Submucosal Dissection for Widespread Superficial Esophageal Squamous Cell Neoplasia
Xin TANG ; Qian-Qian MENG ; Ye GAO ; Chu-Ting YU ; Yan-Rong ZHANG ; Yan BIAN ; Jin-Fang XU ; Lei XIN ; Wei WANG ; Han LIN ; Luo-Wei WANG
Gut and Liver 2025;19(2):198-206
Background/Aims:
Endoscopic radiofrequency ablation (ERFA) is a treatment option for superficial esophageal squamous cell neoplasia (ESCN), with a relatively low risk of stenosis; however, the long-term outcomes remain unclear. We aimed to compare the long-term outcomes of patients with widespread superficial ESCN who underwent endoscopic submucosal dissection (ESD) or ERFA.
Methods:
We retrospectively analyzed the clinical data of patients with superficial ESCN who underwent ESD or ERFA between January 2015 and December 2021. The primary outcome measure was recurrence-free survival.
Results:
Ninety-two and 33 patients with superficial ESCN underwent ESD and ERFA, respectively. The en bloc, R0, and curative resection rates for ESD were 100.0%, 90.2%, and 76.1%, respectively. At 12 months, the complete response rate was comparable between the two groups (94.6% vs 90.9%, p=0.748). During a median follow-up of 66 months, recurrence-free survival was significantly longer in the ESD group than in the ERFA group (p=0.004), while no significant differences in overall survival (p=0.845) and disease-specific survival (p=0.494) were observed.Preoperative diagnosis of intramucosal cancer (adjusted hazard ratio, 5.55; vs high-grade intraepithelial neoplasia) was an independent predictor of recurrence. Significantly fewer patients in the ERFA group experienced stenosis compare to ESD group (15.2% vs 38.0%, p=0.016).
Conclusions
The risk of recurrence was higher for ERFA than ESD for ESCN but overall survival was not affected. The risk of esophageal stenosis was significantly lower for patients who underwent ERFA.
5.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
10.Licorice-saponin A3 is a broad-spectrum inhibitor for COVID-19 by targeting viral spike and anti-inflammation
Yang YI ; Wenzhe LI ; Kefang LIU ; Heng XUE ; Rong YU ; Meng ZHANG ; Yang-Oujie BAO ; Xinyuan LAI ; Jingjing FAN ; Yuxi HUANG ; Jing WANG ; Xiaomeng SHI ; Junhua LI ; Hongping WEI ; Kuanhui XIANG ; Linjie LI ; Rong ZHANG ; Xin ZHAO ; Xue QIAO ; Hang YANG ; Min YE
Journal of Pharmaceutical Analysis 2024;14(1):115-127
Currently,human health due to corona virus disease 2019(COVID-19)pandemic has been seriously threatened.The coronavirus severe acute respiratory syndrome coronavirus 2(SARS-CoV-2)spike(S)protein plays a crucial role in virus transmission and several S-based therapeutic approaches have been approved for the treatment of COVID-19.However,the efficacy is compromised by the SARS-CoV-2 evolvement and mutation.Here we report the SARS-CoV-2 S protein receptor-binding domain(RBD)inhibitor licorice-saponin A3(A3)could widely inhibit RBD of SARS-CoV-2 variants,including Beta,Delta,and Omicron BA.1,XBB and BQ1.1.Furthermore,A3 could potently inhibit SARS-CoV-2 Omicron virus in Vero E6 cells,with EC50 of 1.016 pM.The mechanism was related to binding with Y453 of RBD deter-mined by hydrogen-deuterium exchange mass spectrometry(HDX-MS)analysis combined with quan-tum mechanics/molecular mechanics(QM/MM)simulations.Interestingly,phosphoproteomics analysis and multi fluorescent immunohistochemistry(mIHC)respectively indicated that A3 also inhibits host inflammation by directly modulating the JNK and p38 mitogen-activated protein kinase(MAPK)path-ways and rebalancing the corresponding immune dysregulation.This work supports A3 as a promising broad-spectrum small molecule drug candidate for COVID-19.

Result Analysis
Print
Save
E-mail