1.Establishment of a method for detecting the potency of recombinant human coagulation factor Ⅶa for injection
Rong WU ; Liping WANG ; Jinye LANG ; Yue ZHU ; Jing ZHOU ; Xun LIU ; Jing NI ; Shunbo ZHOU ; Yaling DING
Chinese Journal of Blood Transfusion 2025;38(3):415-420
[Objective] To establish a method for detecting the potency of recombinant human coagulation factor Ⅶa for injection. [Methods] By adding the sample and factor Ⅶ deficient plasma to the sample cup and activating the reaction with prothrombin time assay reagent (PT reagent), the coagulation time of the sample was determined by the change in magnetic bead swing amplitude in the sample cup. The logarithm of coagulation time was inversely proportional to the logarithm of human factor Ⅶa potency. [Results] Under the experimental conditions, the specificity of the methodology was evaluated through spiked recovery, and the recovery rates ranged from 90.0% to 110.0%. Within the range from 0.125 to 1.000 IU/mL, there was a good linear response between the potency and coagulation time of the standard and sample, with correlation coefficients r>0.99. As for the accuracy and repeatability, the recovery rates of various concentrations detected in the stock solution were 101.0%, 100.0% and 112.0%, respectively, with RSD values of 2.6%, 4.0% and 0.0%, respectively. The recovery rates of various concentrations in finished product testing were 104.0%, 94.7% and 112.0%, respectively, with RSD values of 1.9%, 2.4% and 0.0%, respectively. As for the intermediate precision, the RSD were 4.5% and 3.7%, respectively. After treated with sample diluent, the sample was tested at room temperature for 6 hours and still exhibited relatively stable biological activity. [Conclusion] This detection method is accurate, stable, easy to operate and highly automated, and is suitable for detecting the potency of recombinant human coagulation factor Ⅶa for Injection.
2.Feasibility study of low tube voltage and low contrast medium combined with IMR technology in 3DCTA of vertebral artery V3 segment
Junlin YANG ; Duchang ZHAI ; Xiuzhi ZHOU ; Rong LIU ; Guohua FAN ; Wu CAI
Chongqing Medicine 2024;53(1):5-10
Objective To investigate the feasibility of low-voltage,automatic tube current adjustment(ATCM)and low contrast agent concentration,dose and injection rate combined with full-model iterative re-construction(IMR)in vertebral artery V3-segment three-dimensional CT angiography(3DCTA).Methods A total of 60 patients with suspected upper cervical spine,craniocervical junction lesions undergoing cervical vertebral artery V3 segment 3DCTA in this hospital from November 2019 to May 2020 were selected and divided into the group A and B by adopting the random number table method,30 cases in each group.The group A adopted the ATCM technology of 80 kV,average tube current of 50 mAs,25 mL of contrast agent io-hexol(iodine content 300 mg/mL)combined IMR technology with an injection rate of 3 mL/s,while the group B adopted 120 kV,150 mAs fixed tube current,50 mL injection rate of 5 mL/s contrast agent iopamidol(iodine content 370 mg/mL)combined filter back projection(FBP)reconstruction technology.CT value,noise,signal-to-noise ratio(SNR),contrast noise ratio(CNR)and image sensitivity(FOM)were measured and compared between the two groups and the quality of the resulting images was evaluated.The CT volumet-ric dose index(CTDIvol)and dose-length product(DLP)were recorded,and the effective dose(ED)was cal-culated.Results There was no statistically significant difference in the vertebral arterial CT value between the two groups(P>0.05),but the noise of the group A was lower than that of the group B(P<0.05),SNR,CNR and FOM of the group A were greater than those of the group B(P<0.05).The image quality of the two groups met the requirements of clinical diagnosis[(4.78±0.41)points vs.(4.85±0.35)points],and there was no statistically significant difference in the subjective evaluation of image quality(P>0.05).The CTDIvol,DLP and ED levels in the group A were lower than those in the group B(P<0.05).The iodine in-takes of contrast medium in the group A and group B were 7.5 g and 18.5 g,respectively,and the iodine flow rates of contrast agent were 0.9 and 1.85 mg/s,respectively,and compared with group B,the iodine intake and iodine flow rate of the group A were decreased by 59.5%and 51.4%,respectively.Conclusion Low tube voltage ATCM and low contrast concentration,dose and injection rate combined with IMR technology can not only ensure the 3DCTA image quality of vertebral artery V3 segment,but also reduce the radiation dose re-ceived by the patients,and reduce the iodine intake and iodine flow rate of contrast agent.
3.The relationship between activities of daily living and mental health in community elderly people and the mediating role of sleep quality
Heng-Yi ZHOU ; Jing LI ; Dan-Hua DAI ; Yang LI ; Bin ZHANG ; Rong DU ; Rui-Long WU ; Jia-Yan JIANG ; Yuan-Man WEI ; Jing-Rong GAO ; Qi ZHAO
Fudan University Journal of Medical Sciences 2024;51(2):143-150
Objective To explore the relationship and internal path between activities of daily living(ADL),sleep quality and mental health of community elderly people in Shanghai.Methods A questionnaire survey was conducted among community residents aged 60 years and older seeing doctors in community health care center of five streets in Shanghai during Sept to Dec,2021 using convenience sampling.Activities of Daily Living(ADL),Pittsburgh Sleep Quality Index(PSQI)and 10-item Kessler Psychological Distress Scale(K10)were adopted in the survey.Single factor analysis,correlation analysis and multiple linear regression were used to analyze the data.The effect relationship between the variables was tested using Bootstrap's mediated effects test.Results A total of 1 864 participants were included in the study.The average score was 15.53±4.47 for ADL,5.60±3.71 for PSQI and 15.50±6.28 for K10.The rate of ADL impairment,poor sleep quality,poor and very poor mental health of the elderly were 23.6%,27.3%,11.9%and 4.9%,respectively.ADL and sleep quality were all positively correlated with mental health(r=0.321,P<0.001;r=0.466,P<0.001);ADL was positively correlated with sleep quality(r=0.294,P<0.001).Multiple linear results of factors influencing mental health showed that ADL(β= 0.457,95%CI:0.341-0.573),sleep quality(β =0.667,95%CI:0.598-0.737)and mental health were positively correlated(P<0.001).Sleep quality partially mediated the relationship between ADL and mental health(95%CI:0.078-0.124)with an effect size of 33.0%.Conclusion Sleep quality is a mediator between ADL and mental health among community elderly people.Improving ADL and sleep quality may improve mental health in the population.
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.The construction and its implication of the cancer life-cycle prevention and control system in Japan
Dong-Ni HONG ; Sheng WANG ; Xian-Ji WANG ; Chun-Feng WU ; Chun-Yu RONG ; Ping ZHOU
Chinese Journal of Health Policy 2024;17(2):72-78
As the country with the largest number of new cancer cases and deaths,China faces a serious situation with a large cancer population base,low relative survival rate,and low adherence to cancer screening.Neighboring Japan,which has the longest life expectancy in the world,has a much higher relative survival rate than China,despite having a similarly high cancer rate,due to its well-established system of cancer prevention and control.Being an Asian country,the major prevalent cancers in China and Japan are similar in spectrum and can be referred to more.This article introduces the construction of Japan's cancer life-cycle prevention and control system of"cancer prevention","cancer care",and"coexistence with cancer"starting from the three major goals of Japan's cancer prevention and control program,and focuses on the improvement of cancer screening in Japan and the improvement of cancer survival in China.It also highlights the means and methods used to increase the cancer screening rate in Japan,with a view to providing suggestions for cancer prevention and control in China.
8.Two new isocoumarins from cave-derived Metarhizium anisopliae NHC-M3-2
Rong-xiang WU ; Jie-lan GUO ; Hua HUANG ; Jing-jing LIAO ; Yi HAO ; Fan-dong KONG ; Li-man ZHOU ; Chao-jun ZHANG
Acta Pharmaceutica Sinica 2024;59(9):2588-2593
Extracting extracts of secondary metabolites from the karst cave fungus
9.Mechanism of Astragaloside Ⅳ on db/db Mice with Type 2 Diabetes Mellitus and Non-alcoholic Fatty Liver Disease Based on AMPK Signaling Pathway
Min ZHOU ; Xiu LIU ; Yongjun WU ; Qin XIANG ; Rong YU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(5):72-79
ObjectiveTo study the mechanism of astragaloside Ⅳ (AS Ⅳ) on db/db mice with type 2 diabetes mellitus (T2DM) and non-alcoholic fatty liver disease (NAFLD) based on network pharmacology and experimental validation. MethodA total of 24 db/db mice were randomly divided into four groups: model group, metformin group, and low-dose and high-dose AS Ⅳ groups. Six C57 mice were used as the blank group. The low-dose and high-dose AS Ⅳ groups were given AS Ⅳ of 0.015 and 0.030 g·kg-1 by gavage, and the metformin group was given 0.067 g·kg-1 by gavage. The blank and model groups were given equal volumes of distilled water by gavage. After intragastric administration, fasting blood glucose (FBG) was detected, and an oral glucose tolerance test was performed. Serum lipid level and liver histopathology were detected. The target and enrichment pathway of AS Ⅳ for treating T2DM and NAFLD were predicted by network pharmacology, and the main enrichment pathway was verified by molecular biology techniques. The protein expressions of AMPK, p-AMPK, sterol regulatory element-binding protein-1 (SREBP-1), and fatty acid synthetase (FAS) in liver tissue were detected by Western blot. ResultCompared with the blank group, the levels of body mass, liver weight coefficient, fasting blood glucose, serum total cholesterol, triglyceride, and low-density lipoprotein cholesterol in mice treated with AS Ⅳ were decreased (P<0.05, P<0.01). The pathology of liver tissue showed significant improvement in lipid accumulation, and imaging results showed that the degree of fatty liver was reduced after AS Ⅳ therapy. Network pharmacological prediction results showed that vascular endothelial growth factor α (VEGFA), galactoagglutinin 3 (LGALS3), serine/threonine kinase B2 (Akt2), RHO-associated coiled-coil protein kinase 1 (ROCK1), serine/threonine kinase B1 (Akt1), signaling and transcriptional activator protein (STAT3), and messtimal epidermal transformation factor (MET) were key targets in "drug-disease" network. The results from the Kyoto encyclopedia of genes and genomes (KEGG) enrichment showed that the AMP-dependent protein kinase (AMPK) signaling pathway was strongly associated with T2DM and NAFLD. Western blot results showed that compared with the blank group, the expression levels of p-AMPK/AMPK in the model group were significantly down-regulated, while those of SREBP-1 and FAS proteins were significantly up-regulated (P<0.01). Compared with the model group, the expression levels of p-AMPK/AMPK in the metformin group and high-dose AS Ⅳ group were significantly up-regulated, while those of SREBP-1 and FAS proteins were significantly down-regulated (P<0.05, P<0.01). ConclusionAS Ⅳ regulates the expression of lipid proteins by activating the AMPK signaling pathway, thereby improving lipid metabolism.
10.Knowledge-attitude-practice survey and mechanism on AIDS/STDs among migrant workers in the main urban area of Chengdu city
Cuihua Zhang ; Jinglin Zhou ; Luling You ; Yuyan Wu ; Min Luo ; Rong Pei
Acta Universitatis Medicinalis Anhui 2024;59(11):2040-2046
Objective:
To analyze the current situation, influencing factors and mechanism of knowledge-attitude-practice(KAP) regarding acquired immune deficiency syndrome(AIDS)/sexually transmitted diseases(STDs) among migrant workers in Chengdu's main urban area, so as to provide a basis for the development of effective prevention and control policies for this group.
Methods:
Convenience sampling and systematic sampling were used to collect demographic information and data on knowledge, attitudes, and sexual behavior characteristics of AIDS/STDs of the participants. The collected data were organized and statistically analyzed by EpiData 3.1 and SPSS 26.0 software. Additionally, a KAP path analysis model was constructed by using AMOS 24.0 software.
Results:
A total of 257 valid questionnaires were obtained. The AIDS awareness rate was 55.6%, with a mean scores of(5.59±1.61). The awareness rate of STDs was 37.4%, with a mean scores of(9.05±3.00). Discrimination attitudes towards AIDS and STDs were reported by 58 participants(22.6%) and 44 participants(17.1%) respectively. The prevalence of high-risk sexual behavior was 3.50%. Men(OR=0.500, 95%CI: 0.279-0.897) acted as deterrents to knowledge of AIDS. On the other hand, childlessness facilitated discrimination against AIDS(OR=2.748, 95%CI: 1.385-5.451) and STDs(OR=2.287, 95%CI: 1.084-4.825). There was lower likelihood of engaging in high-risk sexual behavior among migrant workers in Chengdu's main urban area who were older(OR=0.854, 95%CI: 0.785-0.929). The occurrence of high-risk sexual behaviors was influenced both directly and indirectly by attitudes towards AIDS and related knowledge. There was a positive correlation between knowledge about AIDS and STDs and attitudes towards them(r=0.15,0.24, bothP<0.05), as well as between attitudes towards AIDS and attitudes towards STDs(r=0.57,P<0.05). That is, the higher the scores of knowledge, the less likely one was to hold discrimination attitudes. Therefore, increasing the rate of knowledge awareness could reduce discrimination towards AIDS/STDs and the occurrence of high-risk sexual behaviors.
Conclusion
The level of AIDS/STDs knowledge among the migrant workers in Chengdu′s main urban area is concerning. Innovative interventions should be intensified in key areas and populations.


Result Analysis