1.SIRT3 protects endometrial receptivity in patients with polycystic ovary syndrome.
Zhonghong ZENG ; Hongying SHAN ; Mingmei LIN ; Siyu BAO ; Dan MO ; Feng DENG ; Yang YU ; Yihua YANG ; Ping ZHOU ; Rong LI
Chinese Medical Journal 2025;138(10):1225-1235
BACKGROUND:
The sirtuin family is well recognized for its crucial involvement in various cellular processes. Nevertheless, studies on its role in the human endometrium are limited. This study aimed to explore the expression and localization of the sirtuin family in the human endometrium, focusing on sirtuin 3 (SIRT3) and its potential role in the oxidative imbalance of the endometrium in polycystic ovary syndrome (PCOS).
METHODS:
Endometrial specimens were collected from both patients with PCOS and controls undergoing hysteroscopy at the Center for Reproductive Medicine, Peking University Third Hospital, from July to August 2015 and used for cell culture. The protective effects of SIRT3 were investigated, and the mechanism of SIRT3 in improving endometrial receptivity of patients with PCOS was determined using various techniques, including cellular bioenergetic analysis, small interfering ribonucleic acid (siRNA) silencing, real-time quantitative polymerase chain reaction, Western blot, immunofluorescence, immunohistochemistry, and flow cytometry analysis.
RESULTS:
The sirtuin family was widely expressed in the human endometrium, with SIRT3 showing a significant increase in expression in patients with PCOS compared with controls ( P <0.05), as confirmed by protein and gene assays. Concurrently, endometrial antioxidant levels were elevated, while mitochondrial respiratory capacity was reduced, in patients with PCOS ( P <0.05). An endometrial oxidative stress (OS) model revealed that the downregulation of SIRT3 impaired the growth and proliferation status of endometrial cells and reduced their receptivity to day 4 mouse embryos. The results suggested that SIRT3 might be crucial in maintaining normal cellular state by regulating antioxidants, cell proliferation, and apoptosis, thereby contributing to enhanced endometrial receptivity.
CONCLUSIONS
Our findings proposed a significant role of SIRT3 in improving endometrial receptivity in patients with PCOS by alleviating OS and regulating the balance between cell proliferation and apoptosis. Therefore, SIRT3 could be a promising target for predicting and improving endometrial receptivity in this patient population.
Humans
;
Female
;
Polycystic Ovary Syndrome/metabolism*
;
Endometrium/metabolism*
;
Sirtuin 3/genetics*
;
Oxidative Stress/genetics*
;
Adult
;
Animals
;
Mice
;
Apoptosis/physiology*
;
Immunohistochemistry
;
Cell Proliferation/physiology*
2.Specific effect of inserted sham acupuncture and its impact on the estimation of acupuncture treatment effect in randomized controlled trials: A systematic survey.
Xiao-Chao LUO ; Jia-Li LIU ; Ming-Hong YAO ; Ye-Meng CHEN ; Arthur Yin FAN ; Fan-Rong LIANG ; Ji-Ping ZHAO ; Ling ZHAO ; Xu ZHOU ; Xiao-Ying ZHONG ; Jia-Hui YANG ; Bo LI ; Ying ZHANG ; Xin SUN ; Ling LI
Journal of Integrative Medicine 2025;23(6):630-640
BACKGROUND:
The use of inserted sham acupuncture as a placebo in randomized controlled trials (RCTs) is controversial, because it may produce specific effects that cause an underestimation of the effect of acupuncture treatment.
OBJECTIVE:
This systematic survey investigates the magnitude of insert-specific effects of sham acupuncture and whether they affect the estimation of acupuncture treatment effects.
SEARCH STRATEGY:
PubMed, Embase and Cochrane Central Register of Controlled Trials were searched to identify acupuncture RCTs from their inception until December 2022.
INCLUSION CRITERIA:
RCTs that evaluated the effects of acupuncture compared to sham acupuncture and no treatment.
DATA EXTRACTION AND ANALYSIS:
The total effect measured for an acupuncture treatment group in RCTs were divided into three components, including the natural history and/or regression to the mean effect (controlled for no-treatment group), the placebo effect, and the specific effect of acupuncture. The first two constituted the contextual effect of acupuncture, which is mimicked by a sham acupuncture treatment group. The proportion of acupuncture total effect size was considered to be 1. The proportion of natural history and/or regression to the mean effect (PNE) and proportional contextual effect (PCE) of included RCTs were pooled using meta-analyses with a random-effect model. The proportion of acupuncture placebo effect was the difference between PCE and PNE in RCTs with non-inserted sham acupuncture. The proportion of insert-specific effect of sham acupuncture (PIES) was obtained by subtracting the proportion of acupuncture placebo effect and PNE from PCE in RCTs with inserted sham acupuncture. The impact of PIES on the estimation of acupuncture's treatment effect was evaluated by quantifying the percentage of RCTs that the effect of outcome changed from no statistical difference to statistical difference after removing PIES in the included studies, and the impact of PIES was externally validated in other acupuncture RCTs with an inserted sham acupuncture group that were not used to calculate PIES.
RESULTS:
This analysis included 32 studies with 5492 patients. The overall PNE was 0.335 (95% confidence interval [CI], 0.255-0.415) and the PCE of acupuncture was 0.639 (95% CI, 0.567-0.710) of acupuncture's total effect. The proportional contribution of the placebo effect to acupuncture's total effect was 0.191, and the PIES was 0.189. When we modeled the exclusion of the insert-specific effect of sham acupuncture, the acupuncture treatment effect changed from no difference to a significant difference in 45.45% of the included RCTs, and in 40.91% of the external validated RCTs.
CONCLUSION
The insert-specific effect of sham acupuncture in RCTs represents 18.90% of acupuncture's total effect and significantly affects the evaluation of the acupuncture treatment effect. More than 40% of RCTs that used inserted sham acupuncture would draw different conclusions if the PIES had been controlled for. Considering the impact of the insert-specific effect of sham acupuncture, caution should be taken when using inserted sham acupuncture placebos in RCTs. Please cite this article as: Luo XC, Liu JL, Yao MH, Chen YM, Fan AY, Liang FR, Zhao JP, Zhao L, Zhou X, Zhong XY, Yang JH, Li B, Zhang Y, Sun X, Li L. Specific effect of inserted sham acupuncture and its impact on the estimation of acupuncture treatment effect in randomized controlled trials: A systematic survey. J Integr Med. 2025; 23(6):630-640.
Acupuncture Therapy/methods*
;
Humans
;
Randomized Controlled Trials as Topic
;
Placebo Effect
;
Placebos
;
Treatment Outcome
3.Quality control protocol for adult overweight and obesity screening in health management (examination) institutions (2025 edition)
Jianling FAN ; Tiejun WANG ; Pengfei YANG ; Keke DING ; Xiaoning HAO ; Sunfang JIANG ; Ankang LÜ ; Jianping LU ; Sheng RONG ; Weibin SHI ; Shengwei SUN ; Yan TAN ; Qilei TU ; Zhiping WANG ; Bing WANG ; Jianyun WANG ; Weijian WANG ; Yan WANG ; Qun XU ; Chenli ZHANG ; Fan ZHANG ; Ping ZHANG ; Yansong ZHENG ; Jieru ZHOU ; Dan CHEN ; Jiaoyang ZHENG
Chinese Journal of Clinical Medicine 2025;32(6):1097-1111
Obesity, as a chronic recurrent disease, has become a major public health challenge in China. To implement the requirements of the Healthy China Initiative (2019—2030), under domestic guidelines or consensus statements on overweight and obesity, and in alignment with the latest scientific advances globally, the Quality control protocol for adult overweight and obesity screening in health management (examination) institutions (2025 edition) was developed. This protocol was drafted by the Health Management Center of Shanghai Changzheng Hospital and formulated through multiple rounds of deliberation by experts in China’s health examination quality control field. The protocol establishes unified standards for screening facilities, personnel qualifications, and measurement or testing procedures. It defines specific screening items, outlines a standardized screening pathway, and sets requirements for the final medical review, ensuring the scientific validity, effectiveness, and safety of the screening process. The implementation of this protocol will enhance the consistency of weight management practices for adults across health examination institutions and strengthen the quality control of overweight and obesity screening programs.
4.Noninvasive Diagnostic Technique for Nonalcoholic Fatty Liver Disease Based on Features of Tongue Images.
Rong-Rui WANG ; Jia-Liang CHEN ; Shao-Jie DUAN ; Ying-Xi LU ; Ping CHEN ; Yuan-Chen ZHOU ; Shu-Kun YAO
Chinese journal of integrative medicine 2024;30(3):203-212
OBJECTIVE:
To investigate a new noninvasive diagnostic model for nonalcoholic fatty liver disease (NAFLD) based on features of tongue images.
METHODS:
Healthy controls and volunteers confirmed to have NAFLD by liver ultrasound were recruited from China-Japan Friendship Hospital between September 2018 and May 2019, then the anthropometric indexes and sampled tongue images were measured. The tongue images were labeled by features, based on a brief protocol, without knowing any other clinical data, after a series of corrections and data cleaning. The algorithm was trained on images using labels and several anthropometric indexes for inputs, utilizing machine learning technology. Finally, a logistic regression algorithm and a decision tree model were constructed as 2 diagnostic models for NAFLD.
RESULTS:
A total of 720 subjects were enrolled in this study, including 432 patients with NAFLD and 288 healthy volunteers. Of them, 482 were randomly allocated into the training set and 238 into the validation set. The diagnostic model based on logistic regression exhibited excellent performance: in validation set, it achieved an accuracy of 86.98%, sensitivity of 91.43%, and specificity of 80.61%; with an area under the curve (AUC) of 0.93 [95% confidence interval (CI) 0.68-0.98]. The decision tree model achieved an accuracy of 81.09%, sensitivity of 91.43%, and specificity of 66.33%; with an AUC of 0.89 (95% CI 0.66-0.92) in validation set.
CONCLUSIONS
The features of tongue images were associated with NAFLD. Both the 2 diagnostic models, which would be convenient, noninvasive, lightweight, rapid, and inexpensive technical references for early screening, can accurately distinguish NAFLD and are worth further study.
Humans
;
Non-alcoholic Fatty Liver Disease/diagnostic imaging*
;
Ultrasonography
;
Anthropometry
;
Algorithms
;
China
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.The construction and its implication of the cancer life-cycle prevention and control system in Japan
Dong-Ni HONG ; Sheng WANG ; Xian-Ji WANG ; Chun-Feng WU ; Chun-Yu RONG ; Ping ZHOU
Chinese Journal of Health Policy 2024;17(2):72-78
As the country with the largest number of new cancer cases and deaths,China faces a serious situation with a large cancer population base,low relative survival rate,and low adherence to cancer screening.Neighboring Japan,which has the longest life expectancy in the world,has a much higher relative survival rate than China,despite having a similarly high cancer rate,due to its well-established system of cancer prevention and control.Being an Asian country,the major prevalent cancers in China and Japan are similar in spectrum and can be referred to more.This article introduces the construction of Japan's cancer life-cycle prevention and control system of"cancer prevention","cancer care",and"coexistence with cancer"starting from the three major goals of Japan's cancer prevention and control program,and focuses on the improvement of cancer screening in Japan and the improvement of cancer survival in China.It also highlights the means and methods used to increase the cancer screening rate in Japan,with a view to providing suggestions for cancer prevention and control in China.
8.A Systematic Review of the Effectiveness Evaluation Tools for Multidisciplinary Diagnosis and Treatment of Tumors
Xin LI ; Yang ZHAO ; Xianji WANG ; Sheng WANG ; Chunyu RONG ; Yingyao CHEN ; Ping ZHOU
Chinese Hospital Management 2024;44(3):39-44
Objective To understand the effectiveness evaluation research of tumor MDT,and analyze the development status and differences of evaluation tools at home and abroad,to provide reference for the subsequent summary evaluation and continuous improvement of tumor MDT,and the strengthening of MDT supervision.Methods Four literature databases at home and abroad were searched to obtain relevant literatures,and literature screening and systematic review were conducted.Results A total of 87 literatures were included,including 26 literatures in Chinese and 61 literatures in English;the most published years were 2020;the main countries of the first authors were the UK.Foreign evaluation tools focus on the key elements of structure and process,while evaluation systems in China focus on the index content at the result level.Conclusion In China,the scientific and comprehensive selection of tumor MDT evaluation indicators needs to be improved,the analysis of influencing factors on the structure and process of MDT needs to be strengthened,and the extrapolation of the existing evaluation systems need to be verified.It is suggested to strengthen the evidence support of evaluation index selection,attach importance to the evaluation of process links,promote the in-depth study of the influencing factors of tumor MDT,and further encourage the empirical application of the existing evaluation system.
9.Ethical considerations on the development and application of artificial intelligence in public health
Chunyu RONG ; Dongni HONG ; Baoyue WANG ; Junwei WANG ; Yunmeng WANG ; Xianglong LI ; Siyu DING ; Ping ZHOU
Shanghai Journal of Preventive Medicine 2024;36(5):504-510
With the development of digital technology, an increasing number of artificial intelligence (AI) technologies are being applied in the field of public health, significantly improving the efficiency of healthcare systems. However, such technological advancement also introduces a series of ethical risks. In this article, we conducted a systematic review by searching nine domestic and international databases and analyzing the ethical issues related to AI in public health, ultimately including 158 articles. Based on the analysis of the included literature, ethical risks were categorized into four aspects: data, algorithms, rights and responsibilities, and social impact. A total of 15 key issues were identified, among which privacy and confidentiality, informed consent, data security, and fairness, justice and inclusion emerged as the most prominent issues. The ethical challenges posed by AI in the field of public health cannot be ignored, and it is necessary to formulate ethical guidelines and practical recommendations for AI in this field, establish sound regulatory and review mechanisms, thereby ensuring the healthy development of AI research in public health.
10.Study of phenylpropanoids from Tripterygium hypoglaucum
Zhi-qi LIN ; Hong-bo ZHU ; Tang ZHOU ; Ji WANG ; Rong-ping ZHANG ; Xing-long CHEN
Acta Pharmaceutica Sinica 2024;59(6):1730-1740
This paper aimed to study phenylpropanoids of

Result Analysis
Print
Save
E-mail