1.A comparative study of short-term effectiveness of "SkyWalker" robot-assisted versus traditional total knee arthroplasty.
Haoming AN ; Hangyu PING ; Haifeng LI ; Wei CHAI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):404-409
OBJECTIVE:
To compare the short-term effectiveness of "SkyWalker" robot-assisted total knee arthroplasty (TKA) and traditional TKA.
METHODS:
A clinical data of 54 patients (54 knees) with TKA who met the selection criteria between January 2022 and March 2022 was retrospectively analyzed. Among them, 27 cases underwent traditional TKA (traditional operation group) and 27 cases underwent "SkyWalker" robot-assisted TKA (robot-assisted operation group). There was no significant difference between the two groups ( P>0.05) in terms of gender, age, body mass index, osteoarthritis side, disease duration, and preoperative Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), visual analogue scale (VAS) score, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and posterior proximal tibial angle (PPTA). The operative time, intraoperative bleeding volume, surgery-related complications, the KSS, WOMAC, and VAS scores before operation and at 6 months after operation, and Forgotten Joint Score (FJS) at 6 months after operation were recorded. X-ray films were taken to review the prosthesis position and measure HKA, LDFA, MPTA, and PPTA. The differences of the clinical and imaging indicators between before and after operation were calculated and statistically analyzed.
RESULTS:
The operations were completed successfully in both groups. There was no significant difference in the operative time and intraoperative bleeding volume between the two groups ( P>0.05). After operation, 1 case of incision nonunion and 1 case of heart failure occurred in the traditional operation group, while no surgery-related complications occurred in the robotic-assisted operation group. The incidences of surgical complications were 7.4% (2/27) in the traditional operation group and 0 (0/27) in the robotic-assisted operation group, with no significant difference ( P=0.491). Patients in both groups were followed up 6 months. KSS score, WOMAC score, VAS score, and ROM significantly improved in both groups at 6 months after operation when compared with preoperative ones ( P<0.05). There was no significant difference between the two groups ( P>0.05) in the differences between the pre- and post-operative values of the clinical indicators and FJS scores at 6 months after operation. X-ray films showed that the lower extremity force lines of the patients improved and the knee prostheses were in good position. Except for LDFA in the robot-assisted operation group, HKA, LDFA, MPTA, and PPTA significantly improved in both groups at 6 months after operation when compared with the preoperative ones ( P<0.05). There was no significant difference between the two groups in the differences between the pre- and post-operative values of the radiological indicators ( P>0.05).
CONCLUSION
The "SkyWalker" robot-assisted TKA is one of the effective methods for the treatment of knee osteoarthritis and had good short-term effectiveness. But the long-term effectiveness needs to be further studied.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Knee Joint/surgery*
;
Knee Prosthesis
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Robotics
;
Treatment Outcome
2.Early clinical application of Mako robot-assisted total knee arthroplasty in knee osteoarthritis.
China Journal of Orthopaedics and Traumatology 2023;36(2):133-139
OBJECTIVE:
To investigate the early efficacy of Mako robot-assisted total knee arthroplasty (TKA) in the treatment of knee osteoarthritis (KOA) and summarize the initial application experience.
METHODS:
Retrospective analysis of 73 patients with KOA treated with Mako robot-assisted TKA from June 2021 to December 2021. There were 16 males and 57 females, aged from 54 to 81 years old with an average of (67.8±6.6) years old. The hip knee and ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), lateral femoral component angle (LFCA) and lateral tibial component angle (LTCA) were recorded and analyzed. WOMAC score and KSS were used to compare the functional recovery of patients preoperatively, 3 and 6 months postoperatively.
RESULTS:
All the 73 patients were successfully treated without serious complications such as vascular and nerve injury, and all the incisions healed well at stageⅠwithout infection. The patients were followed up from 4 to 11 months with an average of (7.0±2.7) months, and the satisfaction rate of the last follow-up was 90.41% (66/73). WOMAC scores were (23.1±5.4) at 3 months and (14.8±4.1) at 6 months postoperatively. KSS clinical scores were ( 76.1±4.0) at 3 months and (82.1±3.7) at 6 months postoperatively;KSS functional scores were (74.3±3.1) at 3 months and (78.6±2.1) at 6 months after operation. Postoperative imaging showed good position of the prosthesis, HKA angle was (178.5±2.1)°, LDFA was (91.2±1.8)°, MPTA was(89.9±1.5) °, LFCA was (7.6±3.1)°, LTCA was (88.2±1.1)°. The mechanical axis within ±3° in sixty cases(82.2%), and the mechanical axis within ±6° in all the patients.
CONCLUSION
Mako robot-assisted TKA is a safe and effective surgery in the treatment of knee osteoarthritis, which exhibited good efficacy in the correction of lower limb alignment, soft tissue balance and improvement of knee function. The long-term efficacy needs further follow-up observation.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Robotics
;
Knee Joint/surgery*
3.Comparison of curative effect between Tianji robot assisted screw placement and traditional cannulated screw internal fixation for femoral neck fracture.
De-Xin NIE ; Wen-Gao SUN ; Xiao-Qiang WANG ; Ming-Jun WANG ; Jin-Bo SUN ; Chun CHEN
China Journal of Orthopaedics and Traumatology 2023;36(3):221-225
OBJECTIVE:
To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.
METHODS:
The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.
RESULTS:
The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).
CONCLUSION
Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.
Male
;
Female
;
Humans
;
Middle Aged
;
Robotics
;
Retrospective Studies
;
Femoral Neck Fractures/surgery*
;
Bone Screws
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
4.Basic performance of domestic surgical robot and the safety and effectiveness of integrated energy equipment.
Zhi SONG ; Guohui WANG ; Liyong ZHU ; Bo YI ; Pengzhou LI ; Shaihong ZHU ; Linli SUN
Journal of Central South University(Medical Sciences) 2023;48(2):221-230
OBJECTIVES:
Surgical robot system has broken the limitation of traditional surgery and shown excellent performance in surgery, and has been widely used in minimally invasive treatment in most areas of surgery. This study aims to verify the basic performance of the domestic surgical robot system and the safety and effectiveness of the integrated bipolar electrocoagulation and ultrasonic knife.
METHODS:
The basic performance of the domestic surgical robot system was evaluated by completing the square knot and surgical knot, vertical and horizontal perforation and right ring perforation and suture, as well as picking up beans. Compared with laparoscopy, the safety and effectiveness of the domestic surgical robot after integrated interconnection bipolar electrocoagulation and ultrasonic scalpel were evaluated by detecting the vascular closure performance and the degree of histopathological damage in animals.
RESULTS:
Compared with freehand knotting, domestic robot knotting speed and circumference were slightly worse, but better than laparoscopic knotting. There was no statistical significance in the tension difference of the surgical knots among the 3 methods (P>0.05), but the tension of the square knots made by the freehand and the domestic surgical robot was greater than that of the laparoscopy (P<0.05). The space required for both the left and right forceps heads of knots was smaller than that of laparoscopy (P<0.001), which successfully completed the 4 quadrant suture tasks, and the time of picking up beans was significantly less than that of laparoscopy (P<0.05). There was no significant difference in the temperature of the liver tissue after the bipolar electrocoagulation between the interconnected domestic surgical robot and the laparoscopy (P>0.05), and the acute thermal injury was observed under the light microscope. The temperature of the liver tissue treated by the domestic robotic ultrasound knife was higher than that of the laparoscopic ultrasound knife (P<0.05).
CONCLUSIONS
Domestic surgical robots are obviously superior to laparoscopy in suturing, knotting, and moving objects, and domestic surgical robots' interconnect bipolar electrocoagulation and ultrasonic knife have achieved success in animal experiments, and hemostasis is considered to be safe and effective.
Animals
;
Robotics
;
Laparoscopy/methods*
;
Ultrasonography
5.Clinical effects of robot-assisted esophageal hiatal hernia repair and laparoscopic esophageal hiatal hernia repair: a retrospective comparative study.
Maimaitiaili MAIMAITIMING ; Duolikun YASHENG ; Yierxiatijiang AINIWAER ; Y L LI ; Aikebaier AILI ; J WANG ; Ke LIMU
Chinese Journal of Surgery 2023;61(6):498-502
Objective: To analyze the short-term clinical effects of robot-assisted and laparoscopic repair of the hiatal hernia. Methods: The clinical data of 56 patients underwent minimally invasive hiatal hernia repair from January 2021 to January 2022 in the Department of Minimally Invasive Surgery, Hernias and Abdominal Wall Surgery, People's Hospital of Xinjiang Uygur Autonomous Region were retrospectively analyzed. There were 32 males and 24 females, aging (59.7±10.7) years (range: 28 to 75 years). All patients were divided into laparoscopy group (n=27) and robot group (n=29) according to surgical procedures. Perioperative conditions, hospital stay, and improvement in symptoms before and after surgery were compared between the two groups by the t test, Wilcoxon rank-sum test and χ2 test. Results: All surgical procedures were successfully completed, without conversion to laparotomy or change in operation mode. There were no serious complications related to the operation. The intraoperative blood loss of the robot group was less than that of the laparoscopic group (M (IQR)): (20 (110) ml vs. 40 (80) ml, Z=-4.098, P<0.01). The operation time ((111.7±33.6) minutes vs. (120.4±35.0) minutes, t=-0.943, P=0.350) and hospitalization time ((3.9±1.4) days vs. (4.7±1.9) days, t=-1.980, P=0.053) of the robot group and the laparoscopic group were similar. Follow-up for 12 months after the operation showed no postoperative complications and recurrence. The score of the health-related quality of life questionnaire for gastroesophageal reflux disease in the robot group decreased from 10.8±2.8 before the operation to 6.5±0.6 after the operation, and that in the laparoscopic group decreased from 10.6±2.1 before the operation to 6.3±0.6 after the operation. There was no difference in the influence of different surgical methods on the change in score (t=0.030,P=0.976). Conclusion: Compared with laparoscopic repair of the hiatal hernia, robot-assisted hiatal hernia repair has the advantages of less bleeding, rapid postoperative recovery and good short-term effect.
Male
;
Female
;
Humans
;
Hernia, Hiatal/complications*
;
Retrospective Studies
;
Robotics
;
Herniorrhaphy/methods*
;
Quality of Life
;
Laparoscopy/methods*
;
Recurrence
;
Fundoplication/methods*
6.Robotic urologic surgery using the KangDuo-Surgical Robot-01 system: A single-center prospective analysis.
Shengwei XIONG ; Shubo FAN ; Silu CHEN ; Xiang WANG ; Guanpeng HAN ; Zhihua LI ; Wei ZUO ; Zhenyu LI ; Kunlin YANG ; Zhongyuan ZHANG ; Cheng SHEN ; Liqun ZHOU ; Xuesong LI
Chinese Medical Journal 2023;136(24):2960-2966
BACKGROUND:
The KangDuo-Surgical Robot-01 (KD-SR-01) system is a new surgical robot recently developed in China. The aim of this study was to present our single-center experience and mid-term outcomes of urological procedures using the KD-SR-01 system.
METHODS:
From August 2020 to April 2023, consecutive urologic procedures were performed at Peking University First Hospital using the KD-SR-01 system. The clinical features, perioperative data, and follow-up outcomes were prospectively collected and analyzed.
RESULTS:
A total of 110 consecutive patients were recruited. Among these patients, 28 underwent partial nephrectomy (PN), 41 underwent urinary tract reconstruction (26 underwent pyeloplasty, 3 underwent ureteral reconstruction and 12 underwent ureterovesical reimplantation [UR]), and 41 underwent radical prostatectomy (RP). The median operative time for PN was 112.5 min, 157.0 min for pyeloplasty, 151.0 min for ureteral reconstruction, 142.5 min for UR, and 138.0 min for RP. The median intraoperative blood loss was 10 mL for PN, 10 mL for pyeloplasty, 30 mL for ureteral reconstruction, 20 mL for UR, and 50 mL for RP. All procedures were successfully completed without conversion, and there were no major complications in any patient. The median warm ischemia time of PN was 17.3 min, and positive surgical margin was not noted in any patient. The overall positive surgical margin rate of RP was 39% (16/41), and no biochemical recurrence was observed in any RP patient during the median follow-up of 11.0 months. The surgical success rates of pyeloplasty and UR were 96% (25/26) and 92% (11/12) during the median follow-up of 29.5 months and 11.5 months, respectively.
CONCLUSION
The KD-SR-01 system appears feasible, safe, and effective for most urological procedures, based on our single-center experience.
Male
;
Humans
;
Robotic Surgical Procedures/methods*
;
Robotics
;
Treatment Outcome
;
Retrospective Studies
;
Ureter/surgery*
;
Urologic Surgical Procedures/methods*
;
Laparoscopy/methods*
7.Research Progress in the Application of Ultrasound-Guided Robot in Minimally Invasive Surgery.
Acta Academiae Medicinae Sinicae 2023;45(5):853-858
With the continuous advances in modern medical technology and equipment,minimally invasive surgery (MIS) is widely applied in clinical practice.Ultrasound (US) as a real-time,portable,and radiation-free medical imaging method can be used for the intraoperative guidance in MIS to ensure safe and effective surgery.However,the physical characteristics of conventional US fail to display some tissue structures of the human body due to the existence of gas and bone.US-based navigation can make up for the deficiencies by advanced imaging technologies including spatial orientation,image reconstruction,and multi-modality image fusion,being real-time,accurate,and radiation-free.Therefore,US-guided robots can achieve safe,effective,and minimally invasive operation in MIS.This paper reviews the studies of US-guided robots in MIS and prospects the development of this field.
Humans
;
Robotics/methods*
;
Minimally Invasive Surgical Procedures/methods*
;
Ultrasonography
;
Spinal Fusion/methods*
;
Ultrasonography, Interventional/methods*
8.A multicenter randomized controlled trial of domestic robot-assisted and conventional total knee arthroplasty.
Yicheng LI ; Xiaogang ZHANG ; Li CAO ; Yongqiang SUN ; Ye YE ; Jie XIE ; Yihe HU ; Zhong LI ; Bensen TANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(11):1326-1334
OBJECTIVE:
To investigate the accuracy, safety, and short-term effectiveness of a domestic robot-assisted system in total knee arthroplasty (TKA) by a multicenter randomized controlled trial.
METHODS:
Between December 2021 and February 2023, 138 patients with knee osteoarthritis who received TKA in 5 clinical centers were prospectively collected, and 134 patients met the inclusion criteria were randomly assigned to either a trial group ( n=68) or a control group ( n=66). Seven patients had lost follow-up and missing data, so they were excluded and the remaining 127 patients were included for analysis, including 66 patients in the trial group and 61 patients in the control group. There was no significant difference ( P>0.05) in gender, age, body mass index, side, duration of osteoarthritis, Kellgren-Lawrence grading, preoperative Knee Society Score (KSS) and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score between the two groups. The trial group completed the TKA by domestic robot-assisted osteotomy according to the preoperative CT-based surgical planning. The control group was performed by traditional osteotomy plate combined with soft tissue release. Total operation time, osteotomy time of femoral/tibial side, intraoperative blood loss, and postoperative complications were recorded and compared between the two groups. The radiographs were taken at 5 and 90 days after operation, and hip-knee-ankle angle (HKA), lateral distal angle of femur (LDFA), and posterior tibial slope (PTS) were measured. The difference between the measured values of the above indexes at two time points after operation and the preoperative planning target values was calculated, and the absolute value (absolute error) was taken for comparison between the two groups. The postoperative recovery of lower limb alignment was judged and the accuracy was calculated. KSS score and WOMAC score were used to evaluate the knee joint function of patients before operation and at 90 days after operation. The improvement rates of KSS score and WOMAC score were calculated. The function, stability, and convenience of the robot-assisted system were evaluated by the surgeons.
RESULTS:
The total operation time and femoral osteotomy time of the trial group were significantly longer than those of the control group ( P<0.05). There was no significant difference in the tibial osteotomy time and the amount of intraoperative blood loss between the two groups ( P>0.05). The incisions of both groups healed by first intention after operation, and there was no infection around the prosthesis. Nine patients in the trial group and 8 in the control group developed lower extremity vascular thrombosis, all of which were calf intermuscular venous thrombosis, and there was no significant difference in the incidence of complications ( P>0.05). All patients were followed up 90 days. There was no significant difference in KSS score and WOMAC score between the two groups at 90 days after operation ( P>0.05). There was significant difference in the improvement rate of KSS score between the two groups ( P<0.05), while there was no significant difference in the improvement rate of WOMAC score between the two groups ( P>0.05). Radiological results showed that the absolute errors of HKA and LDFA in the trial group were significantly smaller than those in the control group at 5 and 90 days after operation ( P<0.05), and the recovery accuracy of lower limb alignment was significantly higher than that in control group ( P<0.05). The absolute error of PTS in the trial group was significantly smaller than that in the control group at 5 days after operation ( P<0.05), but there was no significant difference at 90 days between the two groups ( P>0.05). The functional satisfaction rate of the robot-assisted system was 98.5% (65/66), and the satisfaction rates of stability and convenience were 100% (66/66).
CONCLUSION
Domestic robot-assisted TKA is a safe and effective surgical treatment for knee osteoarthritis, which can achieve favorable lower limb alignment reconstruction, precise implant of prosthesis, and satisfactory functional recovery.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Blood Loss, Surgical
;
Robotics
;
Knee Joint/surgery*
;
Knee Prosthesis
;
Retrospective Studies
9.Research progress of functional alignment robot assisted knee replacement.
Yong-Ze YANG ; Qing-Hao CHENG ; An-Ren ZHANG ; Yi QIU ; Hong-Zhang GUO
China Journal of Orthopaedics and Traumatology 2023;36(11):1106-1110
The correct alignment of the knee joint is considered to be one of the most influential factors in determining the long-term prognosis after total knee arthroplasty(TKA). In order to achieve the correct alignment goal, many different alignment concepts and surgical techniques have been established. For example, mechanical alignment(MA), kinematic alignment(KA) and functional alignment(FA) have their own characteristics. MA focuses on achieving neutral alignment of the limbs, parallel and equal bone gaps during stretching and flexion. KA aims to restore the patient 's natural joint line, make the joint level and angle normal and improve the physiological soft tissue balance, and strive to reproduce the normal knee function;among them, functional alignment(FA) developed with robot-assisted surgery technology is a relatively new alignment concept. It not only considers the alignment of the body, but also aims to achieve flexion and extension balance, while respecting the native soft tissue capsule. It not only restores the plane and slope of the in situ joint line accurately during the operation, but also takes into account the balance of soft tissue, which is a better alignment method. Therefore, it is of great significance to correctly construct the lower limb force line of patients, which is helpful to restore knee joint function, relieve pain symptoms and prolong the service life of prosthesi. However, compared with traditional TKA, the operation time of robot-assisted FA-TKA is prolonged, which means that the probability of postoperative infection will be greater. At present, most studies of FA technology report short-term results, and the long-term efficacy of patients is not clear. Therefore, long-term research results are needed to support the application of this technology. Therefore, the author makes a review on the research status of functional alignment.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Robotics
;
Knee Joint/surgery*
;
Osteoarthritis, Knee/surgery*
;
Knee
;
Knee Prosthesis
;
Biomechanical Phenomena
10.Network meta-analysis comparing the clinical outcomes and safety of robotic, laparoscopic, and transanal total rectal mesenteric resection for rectal cancer.
Yuan LIU ; Wei SHEN ; Zhi Qiang TIAN ; Yin Chao ZHANG ; Guo Qing TAO ; Yan Fei ZHU ; Guo Dong SONG ; Jia Cheng CAO ; Yu Kang HUANG ; Chen SONG
Chinese Journal of Gastrointestinal Surgery 2023;26(5):475-484
Objective: To methodically assess the clinical effectiveness and safety of robot-assisted total rectal mesenteric resection (RTME), laparoscopic-assisted total rectal mesenteric resection (laTME), and transanal total rectal mesenteric resection (taTME). Methods: A computer search was conducted on PubMed, Embase, Cochrane Library, and Ovid databases to identify English-language reports published between January 2017 and January 2022 that compared the clinical efficacy of the three surgical procedures of RTME, laTME, and taTME. The quality of the studies was evaluated using the NOS and JADAD scales for retrospective cohort studies and randomized controlled trials, respectively. Direct meta-analysis and reticulated meta-analysis were performed using Review Manager software and R software, respectively. Results: Twenty-nine publications comprising 8,339 patients with rectal cancer were ultimately included. The direct meta-analysis indicated that the length of hospital stay was longer after RTME than after taTME, whereas according to the reticulated meta-analysis the length of hospital stay was shorter after taTME than after laTME (MD=-0.86, 95%CI: -1.70 to -0.096, P=0.036). Moreover, the incidence of anastomotic leak was lower after taTME than after RTME (OR=0.60, 95%CI: 0.39 to 0.91, P=0.018). The incidence of intestinal obstruction was also lower after taTME than after RTME (OR=0.55, 95%CI: 0.31 to 0.94, P=0.037). All of these differences were statistically significant (all P<0.05). There were no statistically significant differences between the three surgical procedures regarding the number of lymph nodes cleared, length of the inferior rectal margin, or rate of positive circumferential margins (all P>0.05). An inconsistency test using nodal analysis revealed no statistically significant differences between the results of direct and indirect comparisons of the six outcome indicators (all P>0.05). Furthermore, we detected no significant overall inconsistency between direct and indirect evidence. Conclusion: taTME has advantages over RTME and laTME, in terms of radical and surgical short-term outcomes in patients with rectal cancer.
Humans
;
Robotics
;
Robotic Surgical Procedures/adverse effects*
;
Network Meta-Analysis
;
Retrospective Studies
;
Postoperative Complications/etiology*
;
Transanal Endoscopic Surgery/methods*
;
Rectum/surgery*
;
Rectal Neoplasms/pathology*
;
Laparoscopy/methods*
;
Treatment Outcome

Result Analysis
Print
Save
E-mail