1.A Randomized Controlled,Double-Blind Study on Huaban Jiedu Formulation (化斑解毒方) in the Treatment of Psoriasis Vulgaris with Blood-Heat Syndrome
Xuewen REN ; Yutong DENG ; Huishang FENG ; Bo HU ; Jianqing WANG ; Zhan CHEN ; Xiaodong LIU ; Xinhui YU ; Yuanwen LI
Journal of Traditional Chinese Medicine 2025;66(16):1679-1686
ObjectiveTo evaluate the clinical efficacy and safety of Huaban Jiedu Formulation (化斑解毒方, HJF) in treating psoriasis vulgaris with blood-heat syndrome. MethodsA randomized, double-blind, placebo-controlled study was conducted with 60 patients diagnosed with psoriasis vulgaris of blood-heat syndrome. Patients were randomly assigned to either a treatment group or a control group, with 30 cases in each. The treatment group received HJF granules orally, one dose a day, combined with topical Qingshi Zhiyang Ointment (青石止痒软膏), while the control group received placebo granules, one dose a day, combined with the same topical ointment. Both groups were topically treated twice daily of 28 days treatment cours. Psoriasis area and severity index (PASI), visual analogue scale for pruritus (VAS), traditional Chinese medicine (TCM) syndrome scores, dermatology life quality index (DLQI), and psoriasis life stress inventory (PLSI) were assessed before treatment and on day 14 and day 28. Response rates for PASI 50 (≥50% reduction) and PASI 75 (≥75% reduction), as well as overall clinical efficacy, were compared between groups. Serum levels of interleukin-6 (IL-6) and interleukin-17 (IL-17) were measured before and after 28 days of treatment. Adverse reactions during treatment were recorded. ResultsAfter 28 days of treatment, both groups showed significant reductions in PASI total score, lesion area score, erythema, scaling, and infiltration scores, pruritus VAS score, TCM syndrome score, DLQI, PLSI, and serum IL-6 and IL-17 levels (P<0.05). Compared to the control group, the treatment group had significantly greater improvements in PASI total score and erythema score, TCM syndrome score, serum IL-6 and IL-17 levels, and PASI 50 response rate after 28 days (P<0.05). Between-group comparisons of score differences before and after 28-day treatment revealed that the treatment group showed significantly better improvements in PASI total, lesion area score, erythema score, TCM syndrome score, DLQI, PLSI, and inflammatory markers (P<0.05 or P<0.01). The total effective rate on day 14 and day 28 was 40.00% (12/30) and 83.33% (25/30) in the treatment group, versus 6.90% (2/29) and 41.38% (12/29) in the control group, respectively. The clinical efficacy in the treatment group was significantly superior to that in the control group (P<0.05). Mild gastric discomfort occurred in 3 patients in the treatment group and 1 in the control group. ConclusionHJF can effectively improve skin lesions and TCM symptoms relieve pruritus, enhance quality of life, and reduce inflammatory markers IL-6 and IL-17, in patients with blood-heat syndrome of psoriasis vulgaris, with a good safety profile.
2.Clinical application of Commando procedure in reoperation for mechanical valve dysfunction
Bo CHEN ; Ting FAN ; Yong CAO ; Guanshui YU ; Lian HU ; Ren ZHU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):838-841
Objective To explore the feasibility and effectiveness of Commando procedure for mechanical valve dysfunction requiring reoperation. Methods The clinical data of patients who received Commando surgery (aortic/mitral curtain enlargement+valve replacement surgery) in the Department of Cardiovascular Surgery of Gaozhou People's Hospital from December 2021 to September 2022 were retrospectively analyzed. These patients who had undergone mechanical mitral or aortic valve replacement and then had mechanical valve dysfunction with mitral or aortic valve lesions requiring repeat combined valve replacement surgery were selected. Results Eleven patients were enrolled, including 2 males and 9 females, aged 63.63±11.64 years. All 11 patients successfully underwent the Commando operation, and were implanted with suitable artificial valves, among which the aortic valve size was 27.00±2.00 mm, and the mitral valve size was 27.72±3.13 mm. Cardiopulmonary bypass time was 195.81±39.29 min, aortic cross-clamping time was 121.81±28.60 min, mechanical ventilation time was 15.09±3.72 h, ICU stay time was 3.09±0.70 days, and total postoperative thoracic drainage volume was 417.18±68.65 mL. There was no perioperative death. Conclusion Commando procedure is a safe and effective method to perform combined valve operation for mechanical valve dysfunction. A larger artificial valve can be implanted during the procedure to obtain sound hemodynamic effects. In addition, for elderly patients, a suitable type of bioprosthetic valve can be implanted to improve the patient's quality of life. The early surgical effect is satisfactory, and the long-term impact needs further follow-up.
3.TCM Guidelines for Diagnosis and Treatment of Chronic Cough in Children
Xi MING ; Liqun WU ; Ziwei WANG ; Bo WANG ; Jialin ZHENG ; Jingwei HUO ; Mei HAN ; Xiaochun FENG ; Baoqing ZHANG ; Xia ZHAO ; Mengqing WANG ; Zheng XUE ; Ke CHANG ; Youpeng WANG ; Yanhong QIN ; Bin YUAN ; Hua CHEN ; Lining WANG ; Xianqing REN ; Hua XU ; Liping SUN ; Zhenqi WU ; Yun ZHAO ; Xinmin LI ; Min LI ; Jian CHEN ; Junhong WANG ; Yonghong JIANG ; Yongbin YAN ; Hengmiao GAO ; Hongmin FU ; Yongkun HUANG ; Jinghui YANG ; Zhu CHEN ; Lei XIONG
Journal of Nanjing University of Traditional Chinese Medicine 2024;40(7):722-732
Following the principles of evidence-based medicine,in accordance with the structure and drafting rules of standardized documents,based on literature research,according to the characteristics of chronic cough in children and issues that need to form a consensus,the TCM Guidelines for Diagnosis and Treatment of Chronic Cough in Children was formulated based on the Delphi method,expert discussion meetings,and public solicitation of opinions.The guideline includes scope of application,terms and definitions,eti-ology and diagnosis,auxiliary examination,treatment,prevention and care.The aim is to clarify the optimal treatment plan of Chinese medicine in the diagnosis and treatment of this disease,and to provide guidance for improving the clinical diagnosis and treatment of chronic cough in children with Chinese medicine.
4.PTEN Mutation Related Unilateral Multicentric, Synchronous and Metachronous Bilateral Breast Cancer: Three Case Reports
Ru YAO ; Xu YANG ; Yang QU ; Jie LIAN ; Jiahui ZHANG ; Xin HUANG ; Chang CHEN ; Xinyu REN ; Bo PAN ; Yidong ZHOU ; Qiang SUN
Medical Journal of Peking Union Medical College Hospital 2024;15(4):916-920
Phosphatase and tensin-homolog deleted on chromosome 10 (PTEN) is an important cancer suppressor gene. Its pathogenic mutation leads to PTEN hamartoma tumor syndrome (PHTS), a rare syndrome also known as Cowden syndrome, which is relevant to early-onset hereditary breast cancer (BC). In this paper, we report three patients with unilateral multicentric BC and synchronous and metachronous bilateral BC who harbored PTEN gene mutations, and summarize the clinical manifestations, pathological characteristics, diagnosis, treatment and follow-up outcomes to provide reference for management of PTEN gene mutation-related BC among the Cowden syndrome population.
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome (version 2024)
Junyu WANG ; Hai JIN ; Danfeng ZHANG ; Rutong YU ; Mingkun YU ; Yijie MA ; Yue MA ; Ning WANG ; Chunhong WANG ; Chunhui WANG ; Qing WANG ; Xinyu WANG ; Xinjun WANG ; Hengli TIAN ; Xinhua TIAN ; Yijun BAO ; Hua FENG ; Wa DA ; Liquan LYU ; Haijun REN ; Jinfang LIU ; Guodong LIU ; Chunhui LIU ; Junwen GUAN ; Rongcai JIANG ; Yiming LI ; Lihong LI ; Zhenxing LI ; Jinglian LI ; Jun YANG ; Chaohua YANG ; Xiao BU ; Xuehai WU ; Li BIE ; Binghui QIU ; Yongming ZHANG ; Qingjiu ZHANG ; Bo ZHANG ; Xiangtong ZHANG ; Rongbin CHEN ; Chao LIN ; Hu JIN ; Weiming ZHENG ; Mingliang ZHAO ; Liang ZHAO ; Rong HU ; Jixin DUAN ; Jiemin YAO ; Hechun XIA ; Ye GU ; Tao QIAN ; Suokai QIAN ; Tao XU ; Guoyi GAO ; Xiaoping TANG ; Qibing HUANG ; Rong FU ; Jun KANG ; Guobiao LIANG ; Kaiwei HAN ; Zhenmin HAN ; Shuo HAN ; Jun PU ; Lijun HENG ; Junji WEI ; Lijun HOU
Chinese Journal of Trauma 2024;40(5):385-396
Traumatic supraorbital fissure syndrome (TSOFS) is a symptom complex caused by nerve entrapment in the supraorbital fissure after skull base trauma. If the compressed cranial nerve in the supraorbital fissure is not decompressed surgically, ptosis, diplopia and eye movement disorder may exist for a long time and seriously affect the patients′ quality of life. Since its overall incidence is not high, it is not familiarized with the majority of neurosurgeons and some TSOFS may be complicated with skull base vascular injury. If the supraorbital fissure surgery is performed without treatment of vascular injury, it may cause massive hemorrhage, and disability and even life-threatening in severe cases. At present, there is no consensus or guideline on the diagnosis and treatment of TSOFS that can be referred to both domestically and internationally. To improve the understanding of TSOFS among clinical physicians and establish standardized diagnosis and treatment plans, the Skull Base Trauma Group of the Neurorepair Professional Committee of the Chinese Medical Doctor Association, Neurotrauma Group of the Neurosurgery Branch of the Chinese Medical Association, Neurotrauma Group of the Traumatology Branch of the Chinese Medical Association, and Editorial Committee of Chinese Journal of Trauma organized relevant experts to formulate Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome ( version 2024) based on evidence of evidence-based medicine and clinical experience of diagnosis and treatment. This consensus puts forward 12 recommendations on the diagnosis, classification, treatment, efficacy evaluation and follow-up of TSOFS, aiming to provide references for neurosurgeons from hospitals of all levels to standardize the diagnosis and treatment of TSOFS.
9.Research progress of ferroptosis and ischemia-reperfusion injury
Longcan YANG ; Yongxia CHEN ; Hao LUO ; Yuyou HUANG ; Xiaobin REN ; Bo LIU ; Zhaoming HU ; Xufei TIAN ; Feng ZHANG
Chinese Journal of Hepatobiliary Surgery 2024;30(7):556-560
Ferroptosis is a kind of programmed cell death, involves multi-molecular and multi-signaling pathways, and the core processes is iron overload and lipid peroxidation. It affects cancer, neurological disease, cardiovascular disease, digestive system disease, and many other diseases. While, ischemia-reperfusion injury is an extremely complex pathological process, including ischemia-reperfusion injury of the heart, brain, liver and kidney, etc., which often occurs in shock, organ surgery and organ transplantation, seriously affecting human health, and there is no effective radical treatment. However, ferroptosis is closely related to ischemia-reperfusion injury so that it is possible to find the prevention and treatment measures of ischemia-reperfusion injury by exploring the internal relationship between them. Therefore, the author tries to summarize the signaling pathways of ferroptosis, and explores the relationship between ferroptosis and ischemia-reperfusion injury of heart, brain, liver and kidney by moderating the ferroptosis targets properly to find the effective ways to treat cancer, improve inflammation and relieve other diseases.
10.Comparison of surgical effect of various circulatory pathways on replantation of severed distal segment of digits
Lei REN ; Kezhi HU ; Bo LYU ; Zezheng YAN ; Yanbing KANG ; Shichao ZHANG ; Zhonglai XIE ; Ming TANG ; Hui CHEN
Chinese Journal of Microsurgery 2024;47(4):430-437
Objective:To investigate the surgical effect of various circulatory pathways on replantation of severed distal segments of digits.Methods:From June 2017 to June 2023, a total of 137 patients (162 digits) who received digit replantation surgery in the Department of Trauma Orthopaedics and Microsurgery of Guilin People's Hospital were retrospectively studied. The patients were 82 males (97 digits) and 55 females (65 digits) aged 11.0 months to 51.0 years old, with 31.7 years old in average. The injured digits were 36 thumbs, 43 index fingers, 32 middle fingers, 28 ring fingers and 23 little fingers. Causes of injury: 55 digits were of electric saw, 68 of sharp object cut, 26 of twisting crush and 13 of degloving injury. According to the circulatory pathways, 66 patients (88 digits) were assigned to a physiological replantation group (PRG), 50 patients (53 digits) to an arterio-venolisation group (AVG) and 21 patients (21 digits) to a nail bed bloodletting group (NBG). Functional recovery was evaluated according to the Evaluation Standard of Severed Finger Functional of Hand Surgery of Chinese Medical Association. Analysis of variance or chi-square test was employed to analyse the age, gender, time from injury to surgery, surgery time, incidence of vascular compromise of the replanted digit, survival rate, score of functional recovery of the affected digit at 6 months after surgery, and incidence of postoperative complications in each group. P<0.05 was considered statistically significant. Results:All patients were included in the 6-10 months of postoperative follow-up, with an average of 7.2 months. Regarding the score of functional recovery of affected digit according to the Evaluation Standard of Severed Finger Functional of Hand Surgery of Chinese Medical Association, PRG (86.3 points±7.9 points) was higher than that of NBG (78.3 points±11.2 points) and AVG (70.7 points±8.6 points), with statistically significant differences ( P<0.05 for both). In terms of the incidence of vascular compromise, PRG (3 digits for 3.4%) was lower than that of NBG (1 digit for 4.8%) and AVG (6 digits for 11.3%), with statistically significant differences ( P<0.05 for both). Of the survival rate, PRG (81 digits for 92.0%) was superior to that of NBG (18 digits for 85.7%) and AVG (42 digits 79.2%), with statistically significant differences ( P<0.05 for both). While of the incidence of postoperative complications, PRG (12.6%) was lower than that of AVG (17.1%) and NBG (21.2%), with statistically significant differences ( P<0.05 for both). Conclusion:For a severed distal segment of digit, the physiological replantation is preferred. For the digit with undetectable return veins, effective replantation can be achieved by the arterio-venolisation or nail bed exsanguination.

Result Analysis
Print
Save
E-mail