1.Research Progress in Diagnostic Reference Levels in Interventional Radiology.
Pei-Yi QIAN ; Yun LIU ; Jia REN ; Xiao-Jun XU ; Zhi-Xin ZHAO ; Cheng-Jian CAO ; Lei YANG
Acta Academiae Medicinae Sinicae 2023;45(3):506-511
During interventional procedures,subjects are exposed to direct and scattered X-rays.Establishing diagnostic reference levels is an ideal way to optimize the radiation dose and reduce radiation hazard.In recent years,diagnostic reference levels in interventional radiology have been established in different countries.However,because of the too many indicators for characterizing the radiation dose,the indicators used to establish diagnostic reference levels vary in different countries.The research achievements in this field remain to be reviewed.We carried out a retrospective analysis of the definition,establishment method,application,and main factors influencing the dose difference of the diagnostic reference level,aiming to provide a basis for establishing the diagnostic reference level for interventional procedures in China.
Humans
;
Diagnostic Reference Levels
;
Radiology, Interventional/methods*
;
Radiation Dosage
;
Retrospective Studies
;
Radiography
2.Clinical value for contrast-enhanced transrectal ultrasound in diagnosis of prostate cancer.
Journal of Central South University(Medical Sciences) 2018;43(8):882-885
To explore the value for contrast-enhanced transrectal ultrasound (CETRUS) in the diagnosis of prostate cancer.
Methods: Prostate biopsy from 207 cases of suspected prostate cancer were collected between January 2013 and March 2015. These patients were performed ultrasound-guided prostate biopsy in Central Hospital of Changsha. They were randomly divided into a radiography group (n=104) and a non-radiography group (n=103) according to the order of treatment. Transrectal ultrasonography (TRUS) was the first choice in the 2 groups, and CETRUS was conducted in the radiography group. Then, the transrectal biopsy was carried out in the 2 groups. The diagnostic value of CETRUS in prostate cancer was evaluated by pathological examination, a gold standard.
Results: The sensitivity, specificity, and coincidence rates of TRUS in diagnosing prostate cancer were 65%, 60.4%, and 62.8%, respectively, while those rates of CETRUS in diagnosing prostate cancer were 89%, 78%, and 84%, respectively, with significant difference between the above 2 groups (all P<0.05).
Conclusion: The sensitivities, specificities, and coincidence rates for CETRUS are superior to TRUS in diagnosing prostate cancer, which can provide a clinical basis for the diagnosis and differential diagnosis of prostate cancer.
Contrast Media
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration
;
methods
;
Humans
;
Male
;
Prostate
;
diagnostic imaging
;
pathology
;
Prostatic Neoplasms
;
diagnostic imaging
;
pathology
;
Radiography, Interventional
;
Sensitivity and Specificity
;
Ultrasonography
;
methods
3.Prediction of Coronary Atherosclerotic Ostial Lesion with a Damping of the Pressure Tracing during Diagnostic Coronary Angiography.
Ae Young HER ; Soe Hee ANN ; Gillian Balbir SINGH ; Yong Hoon KIM ; Bon Kwon KOO ; Eun Seok SHIN
Yonsei Medical Journal 2016;57(1):58-63
PURPOSE: When performing coronary angiography (CAG), diagnostic catheter intubation to the ostium can cause damping of the pressure tracing. The aim of this study was to determine the predictors of atherosclerotic ostial stenosis in patients showing pressure damping during CAG. MATERIALS AND METHODS: In total, 2926 patients who underwent diagnostic CAG were screened in this study. Pressure damping was defined as an abrupt decline of the coronary blood pressure with a blunted pulse pressure after engagement of the diagnostic catheter. According to CAG and intravascular ultrasound (IVUS), we divided damped ostia into two groups: atherosclerotic ostial lesion group (true lesion group) and non-atherosclerotic ostium group (false lesion group). Clinical and angiographic characteristics were compared between the two groups. RESULTS: The overall incidence of pressure damping was 2.3% (68 patients and 76 ostia). Among the pressure damped ostia, 40.8% (31 of 76 ostia) were true atherosclerotic ostial lesions (true lesion group). The true lesion group had more frequent left main ostial damping and more percutaneous coronary interventions (PCIs) performed on non-ostial lesions, compared to the false lesion group. On multivariate logistic regression analysis, left main ostial damping [hazard ratio (HR) 4.11, 95% confidence interval (CI) 1.24-13.67, p=0.021] and PCI on non-ostial lesion (HR 5.34, 95% CI 1.34-21.27, p=0.018) emerged as independent predictors for true atherosclerotic ostial lesions in patients with pressure damping. CONCLUSION: Left main ostial damping and the presence of a non-ostial atherosclerotic lesion may suggest a significant true atherosclerotic lesion in the coronary ostium.
Aged
;
*Coronary Angiography
;
Coronary Artery Disease/etiology/*radiography
;
Coronary Occlusion/diagnosis/*therapy
;
Coronary Stenosis/etiology/*radiography
;
Coronary Vessel Anomalies/radiography
;
Coronary Vessels/*pathology
;
Female
;
Humans
;
Incidence
;
Male
;
Middle Aged
;
Percutaneous Coronary Intervention/adverse effects/methods
;
Predictive Value of Tests
;
Proportional Hazards Models
;
Radiography, Interventional
4.Initial CT-guided percutaneous biopsy of vertebral lesions: Evaluation of its diagnostic accuracy and clinical value.
Wen-Bin HUA ; Qiang WU ; Bo ZHANG ; Shu-Hua YANG ; Zeng-Wu SHAO ; Wei-Hua XU ; Ye WANG ; Xu-Dong ZHANG
Journal of Huazhong University of Science and Technology (Medical Sciences) 2015;35(4):569-573
This study aimed to examine the diagnostic accuracy and clinical efficacy of initial CT-guided percutaneous biopsy of the vertebral lesions. A total of 305 percutaneous biopsies of the vertebral lesions were performed under either CT guidance (n=127) or C-arm guidance (n=178). The diagnostic accuracy rate was evaluated by comparing the histopathological diagnosis with the ultimate diagnosis. The histopathological diagnosis was consistent with the ultimate diagnosis in 108 (85.0%, 108/127) cases of CT-guided biopsy and in 135 (75.8%, 135/178) cases of C-arm guided biopsy and there was a significant difference. The accuracy of diagnosis based on biopsies varied with different diseases, including primary benign or malignant tumors, metastatic tumors, inflammatory lesions and fractures. A second biopsy or further examinations were required for patients with negative result obtained in the initial biopsy. The complication rate was 3.1% (4/127) in CT-guided biopsy and 7.3% (13/178) in C-arm guided biopsy. In conclusion, CT-guided percutaneous biopsy is an accurate and safe technique for biopsy of the vertebral lesions.
Biopsy, Needle
;
methods
;
Diagnosis, Differential
;
Humans
;
Radiography, Interventional
;
adverse effects
;
methods
;
Reproducibility of Results
;
Retrospective Studies
;
Sensitivity and Specificity
;
Spinal Diseases
;
diagnosis
;
Tomography, X-Ray Computed
;
adverse effects
;
methods
5.CT-Guided Sclerotherapy for Simple Renal Cysts: Value of Ethanol Concentration Monitoring.
Jin Hong YU ; Yong DU ; Yang LI ; Han Feng YANG ; Xiao Xue XU ; Hou Jun ZHENG
Korean Journal of Radiology 2014;15(1):80-86
OBJECTIVE: The aim of our study was to evaluate the differences between sclerotherapy with and without ethanol concentration monitoring for the treatment of simple renal cysts. MATERIALS AND METHODS: Sixty-seven patients with 70 simple renal cysts were randomly assigned to two groups in a 12-month prospective controlled trial. One group (group A) was treated with computed tomography (CT)-guided sclerotherapy without ethanol concentration monitoring (33 patients with 35 cysts), whereas the other group (group B) had ethanol concentration monitoring (34 patients with 35 cysts) during the procedure. Treatment outcomes between the two groups were compared 12 months later with follow-up ultrasound examination. RESULTS: After the 12-month follow-up period, the overall success rate was 74.3% in group A and 94.3% in group B (p = 0.022). The mean cyst size before and after treatment was 8.6 +/- 2.0 cm and 2.3 +/- 2.9 cm, respectively, in group A, and 8.4 +/- 1.7 cm and 0.8 +/- 1.9 cm, respectively, in group B. The final size of the cysts in group B was significantly smaller than that in group A (p = 0.015). The likelihood of treatment with ethanol concentration monitoring being successful was approximately 16 times higher than without ethanol concentration monitoring (p = 0.026; odds ratio = 15.7; 95% confidence interval: 1.38-179.49). There were no major complications in either group. CONCLUSION: Monitoring of Hounsfield units (HU) of ethanol by CT is an effective method in the treatment of simple renal cysts with ethanol sclerotherapy. The ethanol sclerotherapy procedure can be terminated at the point of clear fluid aspiration because the HU (-190) of CT scan corresponds to it.
Adult
;
Aged
;
Aged, 80 and over
;
Cysts/radiography/*therapy
;
Drug Monitoring
;
Ethanol/*administration & dosage/analysis
;
Female
;
Humans
;
Kidney Diseases, Cystic/radiography/*therapy
;
Male
;
Middle Aged
;
Prospective Studies
;
Radiography, Interventional/methods
;
Sclerosing Solutions/*administration & dosage/analysis
;
Sclerotherapy/*methods
;
Tomography, X-Ray Computed/methods
;
Treatment Outcome
;
Young Adult
6.Retrieval Rate and Accuracy of Ultrasound-Guided 14-G Semi-Automated Core Needle Biopsy of Breast Microcalcifications.
Jisook YI ; Eun Hye LEE ; Jeong Ja KWAK ; Jang Gyu CHA ; Sun Hye JUNG
Korean Journal of Radiology 2014;15(1):12-19
OBJECTIVE: To evaluate the retrieval rate and accuracy of ultrasound (US)-guided 14-G semi-automated core needle biopsy (CNB) for microcalcifications in the breast. MATERIALS AND METHODS: US-guided 14-G semi-automated CNB procedures and specimen radiography were performed for 33 cases of suspicious microcalcifications apparent on sonography. The accuracy of 14-G semi-automated CNB and radiology-pathology concordance were analyzed and the microcalcification characteristics between groups with successful and failed retrieval were compared. RESULTS: Thirty lesions were successfully retrieved and the microcalcification retrieval rate was 90.9% (30/33). Thirty lesions were successfully retrieved. Twenty five were finally diagnosed as malignant (10 invasive ductal carcinoma, 15 ductal carcinoma in situ [DCIS]) and five as benign. After surgery and mammographic follow-up, the 25 malignant lesions comprised 12 invasive ductal carcinoma and 13 DCIS. Three lesions in the failed retrieval group (one DCIS and two benign) were finally diagnosed as two DCIS and one benign after surgery. The accuracy of 14-G semi-automated CNB was 90.9% (30/33) because of two DCIS underestimates and one false-negative diagnosis. The discordance rate was significantly higher in the failed retrieval group than in the successful retrieval group (66.7% vs. 6.7%; p < 0.05). Punctate calcifications were significantly more common in the failed retrieval group than in the successful retrieval group (66.7% vs. 3.7%; p < 0.05). CONCLUSION: US-guided 14-G semi-automated CNB could be a useful procedure for suspicious microcalcifications in the breast those are apparent on sonography.
Adult
;
Aged
;
Biopsy, Large-Core Needle/*methods/standards
;
Breast/*pathology
;
Breast Diseases/pathology/radiography
;
Breast Neoplasms/*pathology/surgery/ultrasonography
;
Calcinosis/*pathology/ultrasonography
;
Carcinoma, Ductal, Breast/*pathology/ultrasonography
;
Carcinoma, Intraductal, Noninfiltrating/*pathology/radiography
;
Female
;
Humans
;
Middle Aged
;
*Ultrasonography, Interventional/standards
;
Young Adult
7.Shall we settle for low-level evidence?.
Journal of Gynecologic Oncology 2014;25(3):162-163
No abstract available.
Brachytherapy/*methods
;
Female
;
Humans
;
Radiotherapy, Conformal/*methods
;
Ultrasonography, Interventional/*methods
;
Uterine Cervical Neoplasms/*radiography
8.We should not settle for low-level evidence but should always use the best available evidence.
Kailash NARAYAN ; Linda MILESHKIN ; Sylvia VAN DYK ; David BERNSHAW ; Pearly KHAW ; Srinivas KONDALSAMY CHENNAKESAVAN
Journal of Gynecologic Oncology 2014;25(4):349-351
No abstract available.
Brachytherapy/*methods
;
Female
;
Humans
;
Radiotherapy, Conformal/*methods
;
Ultrasonography, Interventional/*methods
;
Uterine Cervical Neoplasms/*radiography
9.Ultrasound guided conformal brachytherapy of cervix cancer: survival, patterns of failure, and late complications.
Kailash NARAYAN ; Sylvia VAN DYK ; David BERNSHAW ; Pearly KHAW ; Linda MILESHKIN ; Srinivas KONDALSAMY-CHENNAKESAVAN
Journal of Gynecologic Oncology 2014;25(3):206-213
OBJECTIVE: The aim of this study was to report on the long-term results of transabdominal ultrasound guided conformal brachytherapy in patients with cervical cancer with respect to patterns of failures, treatment related toxicities and survival. METHODS: Three hundred and nine patients with cervical cancer who presented to Institute between January 1999 and December 2008 were staged with magnetic resonance imaging and positron emission tomography and treated with external beam radiotherapy and high dose rate conformal image guided brachytherapy with curative intent. Follow-up data relating to sites of failure and toxicity was recorded prospectively. RESULTS: Two hundred and ninety-two patients were available for analyses. The median (interquantile range) follow-up time was 4.1 years (range, 2.4 to 6.1 years). Five-year failure free survival and overall survival (OS) were 66% and 65%, respectively. Primary, pelvic, para-aortic, and distant failure were observed in 12.5%, 16.4%, 22%, and 23% of patients, respectively. In multivariate analysis, tumor volume and nodal disease related to survival, whereas local disease control and point A dose did not. CONCLUSION: Ultrasound guided conformal brachytherapy of cervix cancer has led to optimal local control and OS. The Melbourne protocol compares favorably to the more technically elaborate and expensive GEC-ESTRO recommendations. The Melbourne protocol's technical simplicity with real-time imaging and treatment planning makes this a method of choice for treating patients with cervical cancer.
Adenocarcinoma/pathology/radiography/secondary/ultrasonography
;
Adult
;
Aged
;
Brachytherapy/adverse effects/*methods
;
Carcinoma, Squamous Cell/pathology/radiography/secondary/ultrasonography
;
Female
;
Follow-Up Studies
;
Humans
;
Kaplan-Meier Estimate
;
Lymphatic Metastasis
;
Middle Aged
;
Neoplasm Staging
;
Prognosis
;
Prospective Studies
;
Radiation Dosage
;
Radiotherapy, Conformal/adverse effects/*methods
;
Treatment Failure
;
Ultrasonography, Interventional/*methods
;
Uterine Cervical Neoplasms/pathology/*radiography/ultrasonography
10.Multidetector Computed Tomography for the Evaluation of Coronary Artery Disease; The Diagnostic Accuracy in Calcified Coronary Arteries, Comparing with IVUS Imaging.
Jong Kwan PARK ; Jong Youn KIM ; Hyuck Moon KWON ; Tae Hoon KIM ; Seung Jin OH ; Bum Kee HONG ; Young Won YOON ; Pil Ki MIN ; Sung Woo KWON ; Byoung Kwon LEE
Yonsei Medical Journal 2014;55(3):599-605
PURPOSE: Contrast enhanced multidetector computed tomography (MDCT) has been used as an alternative to coronary angiography for the assessment of coronary artery disease in the patient of the intermediate risk group. However, coronary calcium is a known limiting factor for MDCT evaluation. We investigated the diagnostic accuracy of 64-channel MDCT with each coronary artery calcium score (CACS) by compared with intravascular ultrasound (IVUS) imaging. MATERIALS AND METHODS: A total of 54 symptomatic patients with intermediate-risk (10 females, mean age 59.9+/-6.9 years, Framingham point scores 9-20) with 162 sites who had a culprit lesion on 64-channel MDCT before performing coronary angiography with IVUS were enrolled. Patients were divided into 4 subgroups depending on CACS: 0, 1-99, 100-399, and >400. Lesion length, external elastic membrane (EEM) cross sectional area (CSA), minimal luminal area, and plaque area were measured and compared between IVUS and MDCT. RESULTS: The correlation coefficients for the measurements of the EEM CSA, lumen CSA, and plaque area were r=0.514, r=0.837, and r=0.578, respectively. Furthermore, there were close correlation of plaque area between four subgroups of CACS (r=0.671, r=0.623, r=0.562, r=0.571, respectively). CONCLUSION: Despite the increase in CACS, the geometric analysis of coronary arteries using with 64-channel MDCT was comparable with IVUS in symptomatic patient of the intermediate risk group.
Aged
;
Coronary Artery Disease/*diagnosis/*radiography/ultrasonography
;
Female
;
Humans
;
Male
;
Middle Aged
;
Multidetector Computed Tomography/*methods
;
Predictive Value of Tests
;
Ultrasonography, Interventional/*methods

Result Analysis
Print
Save
E-mail