1.Percutaneous Radiologic Gastrostomy Using the One-Anchor Technique in Patients after Partial Gastrectomy.
Jung Hoon PARK ; Ji Hoon SHIN ; Heung Kyu KO ; Jin Hyoung KIM ; Ho Young SONG ; Soo Hwan KIM
Korean Journal of Radiology 2014;15(4):488-493
OBJECTIVE: The purpose of our study was to assess the feasibility of performing percutaneous radiologic gastrostomy (PRG) in patients who had undergone partial gastrectomy and to evaluate factors associated with technical success. MATERIALS AND METHODS: Nineteen patients after partial gastrectomy, who were referred for PRG between April 2006 and April 2012, were retrospectively analyzed. The remnant stomach was punctured using a 21-gauge Chiba-needle. A single anchor was used for the gastropexy and a 12-Fr or 14-Fr gastrostomy tube was inserted. Data were collected regarding the technical success, procedure time, and presence of any complications. Univariable analyses were performed to determine the factors related to the technical success. RESULTS: Percutaneous radiologic gastrostomy was technically successful in 10 patients (53%), while a failed attempt and failure without an attempt were observed in 5 (26%) and 4 (21%) patients, respectively. Percutaneous radiologic jejunostomy was successfully performed in 9 patients who experienced technical failure. In the 10 successful PRG cases, the mean procedure time was 6.35 minutes. Major complications occurred in 2 patients, tube passage through the liver and pneumoperitonum in one and severe hemorrhage in the other. The technical success rate was higher in patients with Billroth I gastrectomy (100%, 6/6) than in patients with Billroth II gastrectomy (31%, 4/13) (p = 0.011). CONCLUSION: Percutaneous radiologic gastrostomy can be successfully performed using the one-anchor technique in approximately half of the patients after partial gastrectomy.
Aged
;
Aged, 80 and over
;
Analysis of Variance
;
Feasibility Studies
;
Female
;
Gastrectomy/*methods
;
Gastric Stump
;
Gastrostomy/instrumentation/*methods
;
Humans
;
Jejunostomy/methods
;
Male
;
Middle Aged
;
Operative Time
;
Punctures/methods
;
Radiography, Interventional
;
Retrospective Studies
;
Suture Anchors
;
Treatment Outcome
2.Fluoroscopy-Guided Endovenous Sclerotherapy Using a Microcatheter Prior to Endovenous Laser Ablation: Comparison between Liquid and Foam Sclerotherapy for Varicose Tributaries.
Sang Woo PARK ; Ik Jin YUN ; Jae Joon HWANG ; Song Am LEE ; Jun Seok KIM ; Hyun Keun CHEE ; Il Soo CHANG
Korean Journal of Radiology 2014;15(4):481-487
OBJECTIVE: To compare the efficacy and adverse effects of endovenous foam sclerotherapy (EFS) and liquid sclerotherapy (ELS) using a microcatheter for the treatment of varicose tributaries. MATERIALS AND METHODS: From December 2007 to January 2009, patients with venous reflux in the saphenous vein were enrolled. The foam or liquid sclerosant was injected through a microcatheter just before endovenous laser ablation (EVLA). Patients were evaluated for the technical success, clinical success, and procedure-related complications during the procedure and follow-up visits. RESULTS: A total of 94 limbs were included: 48 limbs (great saphenous vein [GSV], 35; small saphenous vein [SSV], 13) were managed using EFS and EVLA (foam group; FG), and 46 limbs (GSV, 37; SSV, 9) were treated by ELS and EVLA (liquid group; LG). Varicose tributaries demonstrated complete sclerosis in 92.7% with FG and in 71.8% with LG (p = 0.014). Bruising (78.7% in FG vs. 73.2% in LG, p > 0.05), pain or tenderness (75.6% in FG vs. 51.2% in LG, p = 0.0237) were noted. Hyperpigmentation (51.2% in FG vs. 46.2% in LG, p > 0.05) was found. CONCLUSION: Endovenous foam sclerotherapy using a microcatheter is more effective than ELS for eliminating remnant varicose tributaries prior to EVLA. However, EFS is more commonly associated with local complications such as pain or tenderness than ELS. Furthermore, both techniques seem to prolong the duration of hyperpigmentation along with higher costs.
Catheters/adverse effects
;
Femoral Vein
;
Fluoroscopy/methods
;
Humans
;
Laser Therapy/methods
;
Radiography, Interventional/methods
;
*Saphenous Vein/radiography/surgery
;
Sclerosing Solutions/*administration & dosage/chemistry
;
Sclerotherapy/adverse effects/instrumentation/*methods
;
Treatment Outcome
;
Varicose Veins/radiography/*therapy
;
Venous Insufficiency/surgery
3.Modified Retroperitoneal Access for Percutaneous Intervention after Pancreaticoduodenectomy.
Korean Journal of Radiology 2013;14(3):446-450
Percutaneous access to the surgical bed after pancreaticoduodenectomy can be a challenge, due to the post-operative anatomy alteration. However, immediate complications, such as surgical bed abscess or suspected tumor recurrence, are often best accessed percutaneously, as open surgical or endoscopic approaches are often difficult, if not impossible. We, hereby, describe a safe approach that is highly replicable, in accessing the surgical bed for percutaneous intervention, following pancreaticoduodenectomy.
Abscess/radiography/therapy
;
Bile Duct Neoplasms/pathology/radiography
;
Biopsy/methods
;
Catheterization/*methods
;
Cholangiocarcinoma/pathology/radiography
;
Drainage/instrumentation/*methods
;
Humans
;
Male
;
Middle Aged
;
Neoplasm Recurrence, Local/pathology/radiography
;
Pancreatic Diseases/radiography/therapy
;
*Pancreaticoduodenectomy
;
Postoperative Complications/radiography/*therapy
;
Radiography, Interventional/methods
;
Retroperitoneal Space
4.Migration of a sirolimus-eluting stent from the ostium of the left main coronary artery to the right deep femoral artery.
Ki Bum WON ; Byeong Keuk KIM ; Young Guk KO ; Myeong Ki HONG ; Yangsoo JANG ; Won Heum SHIM
The Korean Journal of Internal Medicine 2013;28(1):116-119
No abstract available.
Aged
;
Cardiovascular Agents/*administration & dosage
;
Drug-Eluting Stents/*adverse effects
;
*Femoral Artery/radiography/ultrasonography
;
Foreign-Body Migration/diagnosis/*etiology
;
Humans
;
Male
;
Percutaneous Coronary Intervention/*adverse effects/instrumentation
;
Prosthesis Design
;
Sirolimus/*administration & dosage
;
Ultrasonography, Interventional
5.Successful coronary stent retrieval from the ascending aorta using a gooseneck snare kit.
Ji Hun JANG ; Seong Ill WOO ; Dong Hyeok YANG ; Sang Don PARK ; Dae Hyeok KIM ; Sung Hee SHIN
The Korean Journal of Internal Medicine 2013;28(4):481-485
Coronary stent dislodgement is a rare complication of percutaneous coronary intervention. We report a case of stent dislodgement in the ascending thoracic aorta. The stent was mechanically distorted in the left circumflex artery (LCX) while being delivered to the proximal LCX lesion. The balloon catheter was withdrawn, but the stent with the guide wire was remained in the ascending thoracic aorta. The stent was unable to be retrieved into the guide catheter, as it was distorted. A goose neck snare was used successfully to catch the stent in the ascending thoracic aorta and retrieved the stent externally via the arterial sheath.
Angioplasty, Balloon, Coronary/*adverse effects/*instrumentation
;
*Aorta, Thoracic/radiography
;
Cardiac Catheterization/*adverse effects/*instrumentation
;
Coronary Angiography
;
Device Removal/*instrumentation
;
Foreign Bodies/etiology/radiography/*therapy
;
Humans
;
Male
;
Middle Aged
;
Radiography, Interventional
;
*Stents
;
Treatment Outcome
6.CT-Guided Percutaneous Biopsy of Intrathoracic Lesions.
Hira LAL ; Zafar NEYAZ ; Alok NATH ; Samudra BORAH
Korean Journal of Radiology 2012;13(2):210-226
Percutaneous CT-guided needle biopsy of mediastinal and pulmonary lesions is a minimally invasive approach for obtaining tissue for histopathological examination. Although it is a widely accepted procedure with relatively few complications, precise planning and detailed knowledge of various aspects of the biopsy procedure is mandatory to avert complications. In this pictorial review, we reviewed important anatomical approaches, technical aspects of the procedure, and its associated complications.
Biopsy, Needle/instrumentation/*methods
;
Contrast Media/diagnostic use
;
Equipment Design
;
Fluoroscopy
;
Humans
;
Lung Diseases/*pathology/radiography
;
Mediastinal Diseases/*pathology/radiography
;
Patient Positioning
;
Radiography, Interventional/*methods
;
Radiography, Thoracic/*methods
;
*Tomography, X-Ray Computed
7.Fluoroscopically Guided Three-Tube Insertion for the Treatment of Postoperative Gastroesophageal Anastomotic Leakage.
Guowen YIN ; Qingyu XU ; Shixi CHEN ; Xiangjun BAI ; Feng JIANG ; Qin ZHANG ; Lin XU ; Weidong XU
Korean Journal of Radiology 2012;13(2):182-188
OBJECTIVE: To retrospectively evaluate the feasibility and effectiveness of three-tube insertion for the treatment of postoperative gastroesophageal anastomotic leakage (GEAL). MATERIALS AND METHODS: From January 2007 to January 2011, 28 cases of postoperative GEAL after an esophagectomy with intrathoracic esophagogastric anastomotic procedures for esophageal and cardiac carcinoma were treated by the insertion of three tubes under fluoroscopic guidance. The three tubes consisted of a drainage tube through the leak, a nasogastric decompression tube, and a nasojejunum feeding tube. The study population consisted of 28 patients (18 males, 10 females) ranging in their ages from 36 to 72 years (mean: 59 years). We evaluated the feasibility of three-tube insertion to facilitate leakage site closure, and the patients' nutritional benefit by checking their serum albumin levels between pre- and post-enteral feeding via the feeding tube. RESULTS: The three tubes were successfully placed under fluoroscopic guidance in all twenty-eight patients (100%). The procedure times for the three tube insertion ranged from 30 to 70 minutes (mean time: 45 minutes). In 27 of 28 patients (96%), leakage site closure after three-tube insertion was achieved, while it was not attained in one patient who received stent implantation as a substitute. All patients showed good tolerance of the three-tube insertion in the nasal cavity. The mean time needed for leakage treatment was 21 +/- 3.5 days. The serum albumin level change was significant, increasing from pre-enteral feeding (2.5 +/- 0.40 g/dL) to post-enteral feeding (3.7 +/- 0.51 g/dL) via the feeding tube (p < 0.001). The duration of follow-up ranged from 7 to 60 months (mean: 28 months). CONCLUSION: Based on the results of this study, the insertion of three tubes under fluoroscopic guidance is safe, and also provides effective relief from postesophagectomy GEAL. Moreover, our findings suggest that three-tube insertion may be used as the primary procedure to treat postoperative GEAL.
Adult
;
Aged
;
Anastomosis, Surgical
;
Anastomotic Leak/radiography/*therapy
;
Decompression, Surgical/instrumentation
;
Drainage/instrumentation
;
Enteral Nutrition/instrumentation
;
Esophageal Neoplasms/*surgery
;
Esophagectomy
;
Female
;
Fluoroscopy
;
Humans
;
Intubation, Gastrointestinal/*methods
;
Male
;
Middle Aged
;
Postoperative Complications/*radiography/*therapy
;
Radiography, Interventional/*methods
;
Retrospective Studies
;
Stomach Neoplasms/*surgery
8.The Role of Optical Coherence Tomography in Coronary Intervention.
Mitsuyasu TERASHIMA ; Hideaki KANEDA ; Takahiko SUZUKI
The Korean Journal of Internal Medicine 2012;27(1):1-12
Optical coherence tomography (OCT) is an optical analog of intravascular ultrasound (IVUS) that can be used to examine the coronary arteries and has 10-fold higher resolution than IVUS. Based on polarization properties, OCT can differentiate tissue characteristics (fibrous, calcified, or lipid-rich plaque) and identify thin-cap fibroatheroma. Because of the strong attenuation of light by blood, OCT systems required the removal of blood during OCT examinations. A recently developed frequency-domain OCT system has a faster frame rate and pullback speed, making the OCT procedure more user-friendly and not requiring proximal balloon occlusion. During percutaneous coronary intervention (PCI), OCT can provide detailed information (dissection, tissue prolapse, thrombi, and incomplete stent apposition [ISA]). At follow-up examinations after stent implantation, stent strut coverage and ISA can be assessed. Several OCT studies have demonstrated delayed neointimal coverage following drug-eluting stent (DES) implantation vs. bare metal stent (BMS) placement. While newer DESs promote more favorable vascular healing, the clinical implications remain unknown. Recent OCT studies have provided insights into restenotic tissue characteristics; DES restenotic morphologies differ from those with BMSs. OCT is a novel, promising imaging modality; with more in-depth assessments of its use, it may impact clinical outcomes in patients with symptomatic coronary artery disease.
*Angioplasty, Balloon, Coronary/adverse effects/instrumentation
;
Coronary Angiography
;
Coronary Artery Disease/*pathology/radiography/*therapy/ultrasonography
;
Coronary Restenosis/etiology/pathology
;
Coronary Vessels/*pathology/ultrasonography
;
Humans
;
Predictive Value of Tests
;
Severity of Illness Index
;
Stents
;
*Tomography, Optical Coherence
;
Treatment Outcome
;
Ultrasonography, Interventional
9.Percutaneous Radiofrequency Ablation with Multiple Electrodes for Medium-Sized Hepatocellular Carcinomas.
Jung LEE ; Jeong Min LEE ; Jung Hwan YOON ; Jae Young LEE ; Se Hyung KIM ; Jeong Eun LEE ; Joon Koo HAN ; Byung Ihn CHOI
Korean Journal of Radiology 2012;13(1):34-43
OBJECTIVE: To prospectively evaluate the safety and short-term therapeutic efficacy of switching monopolar radiofrequency ablation (RFA) with multiple electrodes to treat medium-sized (3.1-5.0 cm), hepatocellular carcinomas (HCC). MATERIALS AND METHODS: In this prospective study, 30 patients with single medium-sized HCCs (mean, 3.5 cm; range, 3.1-4.4 cm) were enrolled. The patients were treated under ultrasonographic guidance by percutaneous switching monopolar RFA with a multichannel RF generator and two or three internally cooled electrodes. Contrast-enhanced CT scans were obtained immediately after RFA, and the diameters and volume of the ablation zones were then measured. Follow-up CT scans were performed at the first month after ablation and every three months thereafter. Technical effectiveness, local progression and remote recurrence of HCCs were determined. RESULTS: There were no major immediate or periprocedural complications. However, there was one bile duct stricture during the follow-up period. Technical effectiveness was achieved in 29 of 30 patients (97%). The total ablation time of the procedures was 25.4 +/- 8.9 minutes. The mean ablation volume was 73.8 +/- 56.4 cm3 and the minimum diameter was 4.1 +/- 7.3 cm. During the follow-up period (mean, 12.5 months), local tumor progression occurred in three of 29 patients (10%) with technical effectiveness, while new HCCs were detected in six of 29 patients (21%). CONCLUSION: Switching monopolar RFA with multiple electrodes in order to achieve a sufficient ablation volume is safe and efficient. This method also showed relatively successful therapeutic effectiveness on short-term follow up for the treatment of medium-sized HCCs.
Adult
;
Aged
;
Carcinoma, Hepatocellular/radiography/*surgery
;
Catheter Ablation/instrumentation/*methods
;
Contrast Media/diagnostic use
;
Disease Progression
;
Electrodes
;
Female
;
Humans
;
Iohexol/analogs & derivatives/diagnostic use
;
Kaplan-Meier Estimate
;
Liver Neoplasms/radiography/*surgery
;
Male
;
Middle Aged
;
Neoplasm Recurrence, Local
;
Prospective Studies
;
Tomography, X-Ray Computed/*methods
;
Ultrasonography, Interventional
10.Percutaneous Transhepatic Release of an Impacted Lithotripter Basket and Its Fractured Traction Wire Using a Goose-Neck Snare: a Case Report.
Jae Hyun KWON ; Jun Kyu LEE ; Jin Ho LEE ; Yong Seok LEE
Korean Journal of Radiology 2011;12(2):247-251
In a patient with a distal common bile duct stone, a fracture of the traction wire of the basket occurring during the performance of mechanical lithotripsy resulted in the impaction of the lithotripter basket with a stone. The impacted lithotripter basket combined with a fracture of the traction wire is a rare complication of endoscopic stone removal. We were able to pull the impacted basket using an Amplatz goose-neck snare inserted via the percutaneous transhepatic route, which resulted in the freeing of the entrapped stone into the dilated supra-ampullary bile duct. The fractured traction wire and basket could be safely removed by pulling the traction wire from the mouth. The present report is the first to describe the safe and effective use of an Amplatz goose-neck snare for the management of a lithotripter basket impacted with a stone and a fractured traction wire.
Aged
;
Cholangiopancreatography, Endoscopic Retrograde
;
Device Removal/*methods
;
Diagnosis, Differential
;
Equipment Failure
;
Gallstones/radiography/*therapy
;
Humans
;
Lithotripsy/*instrumentation
;
Male
;
Radiography, Interventional
;
Tomography, X-Ray Computed
;
Traction/instrumentation

Result Analysis
Print
Save
E-mail