1.Prevalence of Developmental Dental Anomalies Using Digital Panoramic Radiographs in Libyan Dental Patients
Archives of Orofacial Sciences 2022;17(2):195-207
		                        		
		                        			ABSTRACT
		                        			Dental anomalies may occur due to the complex interactions among genetic, epigenetic, and environmental 
factors during dental development. The current study aimed to determine the prevalence and gender 
significance of developmental dental anomalies (DDA) in dental patients. This was a cross-sectional study 
of 260 subjects (123 males and 137 females) with an age range of 6–35 years old. Clinical and radiographic 
examinations were performed to determine the prevalence of anomalies in tooth number, shape, size, 
position, and structure. Descriptive statistics was performed, the chi-square test was used for analysis and 
p-value was set at 0.05. The findings showed that 203 subjects (78.1%) had DDA, which included 86 males 
(33.1%) and 117 females (45%). A significant gender difference was found regarding the prevalence of 
two anomalies (p < 0.05). The most prevalent anomaly was displacement 51.2%, followed by dilaceration 
24.2%. A significant gender difference (p < 0.05) was found regarding hypodontia 16.5% and impaction 
14.6%, with more predominant in females. Some anomalies were not observed such as microdontia, dentin 
dysplasia, ectopic eruption, gemination, and taurodontism. The study concluded that displacement and 
dilacerations were the common abnormalities. These findings may lead to various dental complications. 
Therefore, early diagnosis and follow-up observation are required to reduce the potential dental problems. 
In addition, it is helpful to increase the knowledge of practitioners with regards to DDA and its occurrence. 
Furthermore, it is good to highlight the importance of early diagnosis of DDA, especially in the mixed 
dentition, which can lead to reducing the complication of an orthodontic treatment plan.
		                        		
		                        		
		                        		
		                        			Tooth Abnormalities
		                        			;
		                        		
		                        			 Radiography, Dental, Digital
		                        			;
		                        		
		                        			 Libya
		                        			
		                        		
		                        	
2.Application of cold flowable gutta-percha in root canal obturation after apexification.
Wen Juan YAN ; Jie ZHONG ; Bi Chen LIN ; Mei Li DING ; Xiao Xian CHEN
Journal of Peking University(Health Sciences) 2022;54(1):77-82
		                        		
		                        			OBJECTIVE:
		                        			To evaluate the clinical effect of root canal obturation therapy using cold flowable gutta-percha on young permanent teeth after apexification.
		                        		
		                        			METHODS:
		                        			Ninety cases of young permanent teeth with pulp necrosis or periapical periodontitis treated by apexification were randomly divided into two groups. The cases in each group were divided into single root canal and multiple root canal according to the number of the root canal, and divided into classifications Ⅰ, and Ⅱ/Ⅲ/Ⅳ according to Frank's classification of root development after apexification. Cold flowable gutta-percha and warm gutta-percha obturation techniques were used for root canal obturation of the two groups. The operation time was recorded, and the patients' therapy pain degree was evaluated by visual analog scale (VAS) immediately after operation. Periapical X-ray was performed after operation to evaluate the effect of the root canal filling. The total length of the root was divided into equal three parts on the X-ray film, and three-dimensional tightness of the apical, middle, and coronal region of the root canals were statistically analyzed respectively. Clinical examinations and X-ray examination were performed 6 and 12 months after the operation to evaluate the treatment success rate.
		                        		
		                        			RESULTS:
		                        			The operation time of cold flowable gutta-percha group was significantly lower than that of the control group, which were 51 s and 74 s (P < 0.05); The percentages of pain and discomfort in the two groups were 26.67% and 40.00%, respectively. There were two cases of underfilling and no overfilling in both groups. The percentages of proper filling and tight three-dimensional obturation in the experimental and control groups were 71.11% and 60.00% respectively; and the percentages of tight three-dimensional obturation in the apical third areas were 86.67% and 66.67%, the difference was significant (P < 0.05). There was no significant difference in the three-dimensional tightness between the two groups in the middle and coronal third areas. The percentages of tight three-dimensional obturation in classification Ⅰ groups were 86.67%, 83.33%, 93.33% and 76.67%, 90.00%, 96.67% in experimental and control group, respectively; The percentages of classification Ⅱ/Ⅲ/Ⅳ groups were 86.67%, 86.67%, 100.00% and 46.67%, 86.67%, 100.00%, respectively, and the difference was significant (P < 0.05). There were no apical lesions that occurred in either group during the one-year review period.
		                        		
		                        			CONCLUSION
		                        			The application of cold flowable gutta-percha on young permanent teeth root canal obturation after apexification can achieve good obturation effect. The root obturation effect in the apical third area is significantly better than that of warm gutta-percha obturation techniques. Cold flowable gutta-percha can shorten the clinical treatment time and ameliorate the patients' therapy comfort.
		                        		
		                        		
		                        		
		                        			Apexification
		                        			;
		                        		
		                        			Dental Pulp Cavity
		                        			;
		                        		
		                        			Gutta-Percha
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Radiography
		                        			;
		                        		
		                        			Root Canal Filling Materials
		                        			;
		                        		
		                        			Root Canal Obturation
		                        			;
		                        		
		                        			Root Canal Preparation
		                        			
		                        		
		                        	
3.Comparative study on radio-opacity of dental composite resin materials'determination using film imaging and digital imaging.
Yuan LI ; Hong LIN ; Tie Jun ZHANG
Journal of Peking University(Health Sciences) 2021;53(5):995-1001
		                        		
		                        			OBJECTIVE:
		                        			To compare the effects of different imaging methods on radio-opacity. Digital imaging and traditional film imaging were used to determine the radio-opacity of dental composite resin materials.
		                        		
		                        			METHODS:
		                        			Fourteen dental composite resins commonly used in clinic were prepared for disc samples with thickness of 1 mm and diameter of 15 mm respectively. The aluminum step wedge was used as the reference and the disc samples were irradiated with X-rays by the traditional film imaging, phosphor imaging plate and charge-coupled device(CCD) intra-oral X-ray sensor respectively. Exposure was set at 65 kV and 7 mA, with 300 mm focus to film distance and the exposure time was 0.25 s. After developing and fixing the film, the optical density of the image of the sample and that of each step of the aluminum step wedge were measured using the densitometer. The digital image file was exported to grey scale analysis software of Adobe Photoshop® to measure the average grey value in the sample image and aluminum step wedge image. The curves were drawn corresponding to the optical density/gray value of each step of the aluminum step wedge and its thickness, and the equivalent thickness of the aluminum plate was calculated according to the optical density/gray value of the actual measured thickness of the sample, so as to evaluate the radio-opacity of dental composite resin material.
		                        		
		                        			RESULTS:
		                        			For the same sample, the aluminum equivalent measured by traditional film imaging and two other digital imagings had significant differences among the 14 composite resins (P < 0.05), and the aluminum equivalent measured by the two digital imagings were greater than that of the traditional film. Moreover the aluminum equivalent measured by the two digital imagings was also different, and the aluminum equivalent measured by the CCD intra-oral X-ray sensor in most composite resins was larger than that measured by phosphor imaging plate. The same sample was photographed with the same imaging method, and the aluminum equivalent was different after three exposures. The standard deviation of aluminum equivalent measured by phosphor imaging plate was the largest, while that measured by CCD intra-oral X-ray sensor was the smallest. Among the 14 dental composite resin materials, the aluminum equivalent of Tetric N-Ceram and Te-Econom Plus measured by traditional film imaging and phosphor imaging plate was significantly higher than other composite resins.
		                        		
		                        			CONCLUSION
		                        			Based on clinical significance, three kinds of sensors designed to measure the radio-opacity of dental composite resin, the value of aluminum equivalent will change according to different types of sensors. The aluminum equivalent measured by CCD intra-oral X-ray sensor was higher than that measured by phosphor imaging plate, and the aluminum equivalent measured by phosphor imaging plate was higher than that measured by traditional film imaging. Moreover, even though the same sensor was used, the aluminum equivalent measured by multiple exposures was different. The standard deviation of the aluminum equivalent measured by phosphor imaging plate was greater than that measured by traditional film imaging and CCD intra-oral X-ray sensor. The three sensors in this study could be used for evaluating the radio-opacity of dental composite resin materials. But no matter what kind of sensor was used to measure the radio-opacity of dental composite resin, it complied to ISO 4049: 2019 standard, the materials were suitable for clinical use.
		                        		
		                        		
		                        		
		                        			Aluminum
		                        			;
		                        		
		                        			Composite Resins
		                        			;
		                        		
		                        			Radiography, Dental, Digital
		                        			
		                        		
		                        	
4.Radiography study on osteotome sinus floor elevation with placed implant simultaneously with no graft augmentation.
Peng LI ; Mu Zi PIAO ; Hong Cheng HU ; Yong WANG ; Yi Jiao ZHAO ; Xiao Jing SHEN
Journal of Peking University(Health Sciences) 2020;53(1):95-101
		                        		
		                        			OBJECTIVE:
		                        			To investigate the change of endo-sinus bone height and bone volume in osteotome sinus floor elevation (OSFE) without bone graft but placing implants simultaneously by using cone beam computed tomography (CBCT) and three dimensional analysis, and to find the impacting factors on endo-sinus bone augmentation.
		                        		
		                        			METHODS:
		                        			OSFE was performed in 38 edentulous patients with missing teeth at posterior maxillary region, and 44 implants were placed and referred for OSFE using no graft materials. CBCT was performed pre-surgery and 9-68 months post-surgery when the patients encountered another implant surgery. The gained bone height at mesial, distal, buccal and palatal sites around the implant in sinus were measured, volumetric measurements of the endo-sinus gained bone volume (ESGBV) in the elevated region were calculated by Mimics software. Univariate analysis and multiple linear regression were performed to investigate the impacting factors on the gained bone height and ESGBV. Marginal bone loss was recorded according to the periapical radiography after implant restoration.
		                        		
		                        			RESULTS:
		                        			The mean residual bone height (RBH) pre-surgery was (3.41±1.23) mm, the mean protruded length (PL) into sinus of implant post-surgery was (3.41±1.28) mm, the mean endo-sinus gained bone height was (2.44±1.23) mm at distal sites, (2.88±1.20) mm at mesial sites, (2.83±1.22) mm at buccal sites and (2.96±1.16) mm at palatal sites, the mean endo-sinus gained bone height at distal sites was significantly lower than the other three sites (P < 0.05). The average endo-sinus gained bone height was (2.78±1.13) mm. The mean ESGBV was (122.15± 73.27) mm3. Univariate analysis showed the more RBH, the less bone height gained in sinus, which existed at buccal, lingual, mesial and distal sites (P < 0.001), and the more RBH, the smaller ESGBV gained (P=0.012). The ESGBV was significantly higher in the subjects whose bone generation period was more than 24 months than those whose bone generation period less than 24 months (P=0.034). The more PL, the more bone height and ESGBV gained (P=0.008). Multivariate analysis showed after adjusting factors of gender, age, smoking, width of sinus floor, thickness of sinus membrane pre-surgery, diameter and length of the implant, PL and bone generation period was positively correlated with mean endo-sinus gained bone height and ESGBV, while RBH negatively correlated with mean endo-sinus gained bone height. During the follow-up, the mean marginal bone loss was 0 (0-1.41) mm and all the implants loaded successfully.
		                        		
		                        			CONCLUSION
		                        			OSFE without bone graft but with placed implant simultaneously can increase endo-sinus gained bone height and ESGBV. RBH, PL and bone generation period are the significant factors impacting endo-sinus bone augmentation.
		                        		
		                        		
		                        		
		                        			Bone Transplantation
		                        			;
		                        		
		                        			Dental Implantation, Endosseous
		                        			;
		                        		
		                        			Dental Implants
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Maxilla/surgery*
		                        			;
		                        		
		                        			Osteotomy
		                        			;
		                        		
		                        			Radiography
		                        			;
		                        		
		                        			Sinus Floor Augmentation
		                        			;
		                        		
		                        			Treatment Outcome
		                        			
		                        		
		                        	
5.Nearinfrared light transillumination for detection of incipient proximal caries in primary molars.
Qiong ZHOU ; Chu Fang PENG ; Man QIN
Journal of Peking University(Health Sciences) 2019;51(1):59-64
		                        		
		                        			OBJECTIVE:
		                        			To evaluate the practical value of nearinfrared light transillumination (NILT, DIAGNOcam) on detection of incipient proximal caries in primary molars.
		                        		
		                        			METHODS:
		                        			In this study, 4-9-year-old children with suspicious proximal lesions in primary molars were recruited. The target teeth were examined with clinical examination, bitewing radiograph and DIAGNOcam. And the caries indexes were rated as 0 (no caries), 1 (caries reaching outer 1/2 enamel), 2 (caries reaching inner 1/2 enamel), and 3 (dentine caries). Those primary molars with at least one of the adjacent molars according with the criteria of invasive treatment, i.e. the teeth were diagnosed as caries reaching inner 1/2 enamel or dentine with at least two detection methods, were included. The target teeth with caries index ≥2 accepted the invasive treatment. And the caries status of the adjacent teeth was observed under direct vision and those teeth of caries index ≥2 would also accept the invasive treatment. The relationship of lesions to enamel-dentine junction (EDJ) were recorded and used as reference standard to compare the sensitivity, specificity and accuracy of those three methods in detecting the incipient proximal caries in primary molars.
		                        		
		                        			RESULTS:
		                        			In this study, 36 children with 104 suspicious proximal lesions in primary molars were recruited, of which 5 were diagnosed as no caries, 20 were diagnosed as superficial enamel caries, and 79 accepted invasive treatment, of which 22 were diagnosed as EDJ caries, and 57 as dentine caries. The sensitivity of clinical examination, bitewing radiograph, and DIAGNOcam were 68.69%, 81.82%, 78.79%, respectively. The specificity were 100.00%, 100.00%, 80.00%, and the accuracy were 75.96%, 85.65%, 78.85%, respectively. As for superficial enamel caries, the sensitivity of clinical examination was lowest, only 10%, while DIAGNOcam was 60%, higher than 40% of bitewing radiograph. As for EDJ caries, the sensitivity of bitewing radiograph was highest as 86.36%, followed by DIAGNOcam 72.73% and clinical examination 68.18%. As for dentine caries, the sensitivity of the three detection methods were higher than 85%, of which bitewing radiograph was the highest as 94.74%.
		                        		
		                        			CONCLUSION
		                        			The accuracy of DIAGNOcam in detecting incipient proximal caries in primary molars was comparable to that of bitewing radiograph. It was safe, and convenient with no exposure to radiation, which was applicable to be used in pediatric dentistry.
		                        		
		                        		
		                        		
		                        			Child
		                        			;
		                        		
		                        			Child, Preschool
		                        			;
		                        		
		                        			Dental Caries
		                        			;
		                        		
		                        			Dentin
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Molar
		                        			;
		                        		
		                        			Radiography, Bitewing
		                        			;
		                        		
		                        			Reproducibility of Results
		                        			;
		                        		
		                        			Tooth, Deciduous
		                        			;
		                        		
		                        			Transillumination
		                        			
		                        		
		                        	
6.Surgical management of an accessory canal in a maxillary premolar: a case report
Hee Jin KIM ; Mi Kyung YU ; Kwang Won LEE ; Kyung San MIN
Restorative Dentistry & Endodontics 2019;44(3):e30-
		                        		
		                        			
		                        			We report the surgical endodontic treatment of a maxillary first premolar with a lateral lesion that originated from an accessory canal. Although lesions originating from accessory canals frequently heal with simple conventional endodontic therapy, some lesions may need additional and different treatment. In the present case, conventional root canal retreatment led to incomplete healing with the need for further treatment (i.e., surgery). Surgical endodontic management with a fast-setting calcium silicate cement was performed on the accessory canal using a dental operating microscope. At the patient's 9-month recall visit, the lesion was resolved upon radiography.
		                        		
		                        		
		                        		
		                        			Bicuspid
		                        			;
		                        		
		                        			Calcium
		                        			;
		                        		
		                        			Dental Pulp Cavity
		                        			;
		                        		
		                        			Radiography
		                        			;
		                        		
		                        			Retreatment
		                        			;
		                        		
		                        			Silicate Cement
		                        			;
		                        		
		                        			Silicates
		                        			
		                        		
		                        	
7.Factors affecting modulation transfer function measurements in cone-beam computed tomographic images
Imaging Science in Dentistry 2019;49(2):131-137
		                        		
		                        			
		                        			PURPOSE: This study was designed to investigate the effects of voxel size, the oversampling technique, and the direction and area of measurement on modulation transfer function (MTF) values to identify the optimal method of MTF measurement. MATERIALS AND METHODS: Images of the wire inserts of the SedentexCT IQ phantom were acquired, and MTF values were calculated under different conditions (voxel size of 0.1, 0.2, and 0.3 mm; 5 oversampling techniques; simulated pixel location errors; and different directions and areas of measurement). The differences in the MTF values across various conditions were evaluated. RESULTS: The MTF 10 values showed smaller standard deviations than the MTF 50 values. Stable and accurate MTF values were obtained in the 0.1-mm voxel images. In the 0.3-mm voxel images, oversampling techniques of 11 lines or more did not show significant differences in MTF values depending on the presence of simulated location errors. MTF 10 values showed significant differences according to the direction and area of the measurement. CONCLUSION: To measure more accurate and stable MTF values, it is better to measure MTF 10 values in small-voxel images. In large-voxel images, the proper oversampling technique is required. MTF values from the radial and tangential directions may be different, and MTF values vary depending on the measured area.
		                        		
		                        		
		                        		
		                        			Cone-Beam Computed Tomography
		                        			;
		                        		
		                        			Methods
		                        			;
		                        		
		                        			Quality Control
		                        			;
		                        		
		                        			Radiography, Dental
		                        			
		                        		
		                        	
8.The influence of different scan resolutions on the detection of proximal caries lesions
Liana Matos FERREIRA ; Polyane Mazucatto QUEIROZ ; Gustavo Machado SANTAELLA ; Ann WENZEL ; Francisco Carlos GROPPO ; Francisco HAITER-NETO
Imaging Science in Dentistry 2019;49(2):97-102
		                        		
		                        			
		                        			PURPOSE: This study was conducted to evaluate the effect of different spatial resolutions of a photostimulable phosphor plate (PSP) radiography system on the detection of proximal caries lesions. MATERIALS AND METHODS: Forty-five extracted human permanent teeth were radiographed using a PSP system (VistaScan Perio Plus) and scanned at the 4 resolutions (10 lp/mm, 20 lp/mm, 25 lp/mm, and 40 lp/mm) available in the system. Three independent examiners scored the images for the presence and absence of proximal caries lesions using a 5-point scale. The presence or absence of caries was confirmed by histological sections of the examined teeth (defined as the gold standard). Intra- and inter-observer reproducibility was calculated by the weighted kappa test. One-way analysis of variance with the post hoc Tukey test was used to compare the area under the receiver operating characteristic curve for the classifications made with each resolution. RESULTS: For the detection of enamel lesions, the spatial resolution of 10 lp/mm was significantly superior to the other resolutions. However, the spatial resolution did not affect the detection of caries lesions in dentin (P>0.05). CONCLUSION: Spatial resolution may influence the accuracy of the detection of incipient caries lesions in radiographs with PSP plates. Images with low spatial resolution seem to be more appropriate for this purpose.
		                        		
		                        		
		                        		
		                        			Classification
		                        			;
		                        		
		                        			Dental Caries
		                        			;
		                        		
		                        			Dental Enamel
		                        			;
		                        		
		                        			Dentin
		                        			;
		                        		
		                        			Diagnostic Imaging
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Radiography
		                        			;
		                        		
		                        			ROC Curve
		                        			;
		                        		
		                        			Tooth
		                        			
		                        		
		                        	
9.Determination and classification of intraoral phosphor storage plate artifacts and errors
Imaging Science in Dentistry 2019;49(3):219-228
		                        		
		                        			
		                        			PURPOSE: The aim of this study was to determine the reasons and solutions for intraoral phosphor storage plate (PSP) image artifacts and errors, and to develop an appropriate classification of the artifacts. MATERIALS AND METHODS: This study involved the retrospective examination of 5,000 intraoral images that had been obtained using a phosphor plate system. Image artifacts were examined on the radiographs and classified according to possible causative factors. RESULTS: Artifacts were observed in 1,822 of the 5,000 images. After examination of the images, the errors were divided into 6 groups based on their causes, as follows: images with operator errors, superposition of undesirable structures, ambient light errors, plate artifacts (physical deformations and contamination), scanner artifacts, and software artifacts. The groups were then re-examined and divided into 45 subheadings. CONCLUSION: Identification of image artifacts can help to improve the quality of the radiographic image and control the radiation dose. Knowledge of the basic physics and technology of PSP systems could aid to reduce the need for repeated radiography.
		                        		
		                        		
		                        		
		                        			Artifacts
		                        			;
		                        		
		                        			Classification
		                        			;
		                        		
		                        			Diagnostic Imaging
		                        			;
		                        		
		                        			Radiography
		                        			;
		                        		
		                        			Radiography, Dental
		                        			;
		                        		
		                        			Retrospective Studies
		                        			
		                        		
		                        	
10.Dental students' ability to detect maxillary sinus abnormalities: A comparison between panoramic radiography and cone-beam computed tomography
Lucas de Paula Lopes ROSADO ; Izabele Sales BARBOSA ; Sibele Nascimento AQUINO ; Rafael Binato JUNQUEIRA ; Francielle Silvestre VERNER
Imaging Science in Dentistry 2019;49(3):191-199
		                        		
		                        			
		                        			PURPOSE: To compare the diagnostic ability of undergraduate dental students to detect maxillary sinus abnormalities in panoramic radiographs (PR) and cone-beam computed tomography (CBCT). MATERIALS AND METHODS: This was a retrospective study based on the evaluation of PR and CBCT images. A pilot study was conducted to determine the number of students eligible to participate in the study. The images were evaluated by 2 students, and 280 maxillary sinuses were assessed using the following categories: normal, mucosal thickening, sinus polyp, antral pseudocyst, nonspecific opacification, periostitis, antrolith, and antrolith associated with mucosal thickening. The reference standard was established by the consensus of 2 oral radiologists based on the CBCT images. The kappa test, receiver operating characteristic curves, and 1-way analysis of variance with the Tukey-Kramer post-hoc test were employed. RESULTS: Intraobserver and interobserver reliability showed agreement ranging from substantial (0.809) to almost perfect (0.922). The agreement between the students' evaluations and the reference standard was reasonable (0.258) for PR and substantial (0.692) for CBCT. Comparisons of values of sensitivity, specificity, and accuracy showed that CBCT was significantly better (P<0.05). CONCLUSION: CBCT was better than PR for the detection of maxillary sinus abnormalities by dental students. However, CBCT should only be requested after a careful analysis of PR by students and more experienced professionals.
		                        		
		                        		
		                        		
		                        			Cone-Beam Computed Tomography
		                        			;
		                        		
		                        			Consensus
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Maxillary Sinus
		                        			;
		                        		
		                        			Periostitis
		                        			;
		                        		
		                        			Pilot Projects
		                        			;
		                        		
		                        			Polyps
		                        			;
		                        		
		                        			Radiography, Panoramic
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			ROC Curve
		                        			;
		                        		
		                        			Sensitivity and Specificity
		                        			;
		                        		
		                        			Students, Dental
		                        			
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail